970 resultados para EQUIPMENT CONTAMINATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sterol biomarkers serve as an alternative method for detecting sewage pollution. Sterols were extracted from samples of surface sediment collected in Cubato (the Vila dos Pescadores and Vila Esperan double dagger a communities) and quantified using GC-MS after Soxhlet extraction, cleanup, and derivatization. Fecal contamination was evaluated based on the concentration of coprostanol and the ratio of the selected sterols. The most abundant sterol was cholestanol, followed by coprostanol. The concentrations of coprostanol in surface sediments ranged from a minimum of 4.21 mu g g(-1) dry sediment (Vila dos Pescadores station) to a maximum of 8.32 mu g g(-1) dry sediment (Vila Esperan double dagger a station). A coprostanol concentration of about 10 mu g g(-1) was found, indicating areas of high sewage contamination. Coprostanol levels at sewage stations were higher than in other Brazilian coastal areas, which may be attributed to the fraction of the population without sanitation services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of the present study were to evaluate the spread of Salmonella Enteritidis to different cutting boards (wood, triclosan-treated plastic, glass, and stainless steel) from contaminated poultry skin (5 log CFU/g) and then to tomatoes and to analyze the effect of different protocols used to clean these surfaces to control contamination. The following procedures were simulated: (1) no cleaning after handling contaminated poultry skin; (2) rinsing in running water; (3) cleaning with dish soap and mechanical scrubbing; and (4) cleaning with dish soap and mechanical scrubbing, followed by disinfection with hypochlorite. The pathogen was recovered from all surfaces following procedure 1, with counts ranging from 1.90 to 2.80 log, as well as from the tomatoes handled on it. Reduced numbers of S. Enteritidis were recovered using the other procedures, both from the surfaces and from the tomatoes. Counts were undetectable after procedure 4. From all surfaces evaluated, wood was the most difficult to clean, and stainless steel was the easiest. The use of hypochlorite as a disinfecting agent helped to reduce cross-contamination. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temporal and spatial acoustic intensity (SATA) of therapeutic ultrasound (US) equipment should be monitored periodically. In order to evaluate the conditions of US equipment in use in the city of Piracicaba-Sao Paulo, Brazil, 31 machines - representing all Brazilian manufacturers - were analysed under continuous and pulsed conditions at a frequency of 1 MHz. Data about temporal and spatial acoustic intensity were collected and the use of equipment was surveyed. Intensities of 0.1, 0.2, 0.5, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0 Wcm -2, indicated on the equipment panel were analysed using a previously calibrated digital radiation pressure scale, model UPM-DT-1 (Ohmic Instruments Co). The acoustic intensity (I) results were expressed as superior and inferior quartile ranges for transducers with metal surfaces of 9 cm 2 and an effective radiation area (ERA) Of 4 cm 2. The results under continuous conditions were: I 0.1 = -20.0% and -96%. I 0.2 = -3.1% and -83.7%. I 0.5 = -35.0% and -86.5%. I 0.8 = -37.5% and -71.0%. I 2.5 = -49.0% and -69.5%. I 3.0 = -58.1% and -77.6%. For pulsed conditions, intensities were: I 0.1 = -40.0% and -86.2%. I 1.0 = -50.0% and -86.5%. I 1.5 = -62.5% and -82.5%. I 2.0 = -62.5% and -81.6%. I 2.5 = -64.7% and -88.8%. I 3.0 = -87.1% and -94.8%. In reply to the questionnaire drawn up to check the conditions of use of equipment, all users reported the use of hydrosoluble gel as a coupling medium and none had carried out previous calibrations. Most users used intensities in the range of 0.4. to 1.0 Wcm -2 and used machines for 300 to 400 minutes per week. The majority of machines had been bought during the previous seven years and weekly use ranged from less than 100 minutes to 700 minutes (11 hours 40 minutes). Findings confirm previous observations of discrepancy between the intensity indicated on the equipment panel and that emitted by the transducer and highlight the necessity for periodic evaluations of US equipment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of the present study were to evaluate the safety of mixer/loaders and applicators of paraquat to maize crop by knapsack sprayers and to determine the efficacy of safety measures applied to the sprayers. Potential dermal exposure (PDE) was evaluated in 22 worker body parts. The Cu2+ cation of a copper-based fungicide was used as tracer in the spray solution. Sanitary pads and cotton gloves were used to collect the pesticide solution on the sampled body parts. It was observed that paraquat application in front of the applicator's body (0.5 and 1.0 m lance) is unsafe because PDE was 1,979.8 ml/day (for 0.5 m lance) and 1,290.4 ml/day (for 1.0 m lance) and needs 50-80% and 37-69% control of PDE respectively. Control can be achieved by the use of protective garment on the legs and feet only, which received 92-93% of the PDE. Switching the spray nozzle to the back of the operator reduced the PDE by 98% and was sufficient to make working conditions safe, while maintaining the efficiency of application and making the work lighter and more comfortable. Mixer/loaders received 86% of the PDE to the hands and the work condition was safe (MOS > 1), however impermeable gloves could be used as a further safety measure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the characteristics of spray produced by Yamaho nozzle tip'D'series. The droplet size of nozzle tips D3, D4, D5, D6 and D8 were evaluated at 703, 1.050, 1.406, 1.758, 2.110, 2.461 e 2.813 kPa pressures (100, 200, 250; 350, e 400 psi) by means of laser equipment, as well as the flow rate of nozzle tip at the pressures of 702, 1.125, 1.406, 1.828, 2.110, 2.532 e 2.813 kPa (100, 160, 200, 260,300; 360 e 400 psi) which were compared with values indicated by manufacturer. The droplet produced at all pressures presented a very fine spray, which in agriculture may promote losses by evaporation and drift. For all nozzle tips, except D8 in pressures 1.828, 2.532 e 2.813 kPa, the difference between the observed flow rate indicated by the manufacturer was higher than 5%. The paper demonstrates that the nozzle tip tested, in spite of not having uniform flow rate, may promote the contamination of spray operator and environment due to the droplet spectrum produced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study tested the null hypothesis that different treatments of saliva-contaminated substrate would not affect microgap formation at the dentin walls of bonded restorations. Materials and Methods: Forty freshly extracted human molars received standardized Class V preparations on buccal and lingual surfaces. The specimens were assigned to four experimental groups (n = 20): [G1] no contamination (control group), [G2] saliva contamination (10 s) after etching followed by 5 s air stream; [G3] saliva contamination after etching and rinsed for 10 s; and [G4] re-etching for 10 s after saliva contamination. All specimens were restored with a one-bottle adhesive (Single Bond, 3M ESPE) and microhybrid composite resin (Filtek Z250, 3M ESPE) according to the manufacturer's instructions. The specimens were thermocycled, sectioned through the center of the restoration, and then processed for SEM. Microgaps were measured at the axial wall at 1500X magnification. The data were submitted to Kruskal-Wallis nonparametric statistical analysis at p < 0.05. Results: The data revealed that different groups resulted in a statistically significant difference (p < 0.01) in gap formation. Air drying [G2] and rinsing [G3] the saliva-contaminated dentin resulted in similar microgap values (p > 0.05). However, re-etching the dentin after saliva contamination [G4] increased microgap formation (p < 0.05) when compared with the groups G1 and G2. Although air drying and rinsing produced results comparable to noncontaminated dentin, the presence of microgaps was not completely eliminated. Conclusion: Contaminated saliva did not prevent hybrid layer formation; however, it did reduce the adaptation of the restorative material to bonded surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project has been developed to evaluate the possible relationship between the cesspit (pit latrine) in as far as it degrades the quality of underground water. Its importance is due to the fact that in the rural communities in the State of São Paulo (Brazil) this type of cesspit is very common as a means of sewage disposal and these communities use underground water for their supply of drinking water. Rural properties distributed over the rural area in the municipality of São José do Rio Preto were selected. A preliminary study was then set up to determine the social situation and health of the households as well as qualitative evaluations on the type of water supply and sewage disposal of these communities. Campaigns of water sampling then followed and laboratory analyses of water taken from wells were carried out. Parameters were set up to evaluate the potability according to Brazilian legislation (2004) paying attention to microbiologic (coliforms, Crytosporidium sp., and adenovirus). The analyses showed evidence of possible interaction between the wells and the sewage effluents and drainage in these communities. A PCR reaction to detect adenovirus showed a presence in 53.3% of the samples. The tests for the detection of Cryotosporidium sp all showed a negative result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed to study the bacterial contamination in stings of the catfish Genidens genidens and Cathorops agassizii found in the São Vicente estuarine system (São Paulo State, Brazil). For bacteriological analyses, we used fish samples distributed into a group of 50 specimens (25 C. agassizii and 25 G. genidens) and a group of 14 specimens (7 C. agassizii and 7 G. genidens). Results showed contamination of 13 different bacterial species of Enterobacteriaceae, being Klebsiella pneumoniae the most frequent bacteria (26.80%) followed by Enterobacter sp and Escherichia coli (16.27%), and Serratia marcescens, Serratia sp. and Proteus mirabilis (1.16%). Gram-positive bacteria as well as fungi were not detected in the samples. According to the Gram-negative species characterized and with regard to the environmental conditions, it can also be considered that accidents with these catfish stings may develop significant acute secondary infections in humans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water from dental equipment presents risks for surgeon-dentists as well as for patients because it might work as a means of dissemination/ transmission of microoganisms. The objective of this study was to verify the quality of the water used in dental equipment by means of microbiological analysis, accomplishing the count of Staphylococcus spp.There have been collected, 160 samples of water from reserviors, taps used for hand washing, air-water syringes, and high-speed handpieces, in 40 dental offices in the city of Barretos, São Paulo. The rules concerning bacteriotogicaI analysis in cfu/mL from Standard Methods for the Examination of Water and Wastewater have been followed. The analysis of the results has made it possible to verify that out of the total of samples, 28% did not meet the standards of potability established by the American Dental Association: Regarding the origin of analyzed S. aureus., the most contaminated sites were high-speed handpicces in private offices (761%) and in, ental care plan offices (71%), followed by air-water syringe in dental care plan offices (64%). For S. epidermitis samples, the most contaminated sites were high-speed handpieces in SUS (Brazilian Government Health System) dental offices (22%) and in dental care plan offices (14%) The most contaminated sites were dental offices that saw Patients under dental care plans, Concerning tested antibiotics, the ones that presented better results as to sensibility to strain S. epidermidis were vancomycin and ciprofloxacin (100%) and, as to sensibility to strain S. aureus, it was ciprofloxacin (97%).