517 resultados para EOS PEEK HP3


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Observing and documenting life cycle stages of plants and animals have been tradition and necessity for humans throughout history. Phenological observations—as called by their modern scientific name—were key to successful hunting and farming because the precise knowledge of animal behavior and plant growth, as well as their timing with changing seasons, was critical for survival. In today's context of environmental awareness and climate change research, phenological observations have become prime indicators of documenting altered life cycles due to environmental change in disciplines from biology to climatology, geography, and environmental history. Observations on the ground, from space, and from models of different complexity describe intra-annual and interannual changes of life cycles at individual, pixel, or grid box scale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zur schnellen Herstellung von Metallteilen eignen sich die schichtweise Rapid Prototyping Verfahren. Zum einen ist die direkte Herstellung aus Zweikomponenten-Metallpulver möglich, zum anderen lassen sich aus Kunststoffüberzogenen Metallpulvern durch Infiltration komplexe Metallteile fertigen. Der Vortrag beschreibt die Prozessketten der beiden Verfahren und stellt ihre besonderen Eigenschaften gegenüber. Anhand von Praxisbeispielen wird die tatsächliche Leistungsfähigkeit beider Verfahren aufgeführt. Es werden die beiden Verfahren “Direct Metal Laser Sintering“ (DMLS) und “Indirect Metal Laser Sintering“ (IMLS) zur Herstellung von Gesenken und Bauteilen vorgestellt. Das “Direct Metal Laser Sintering“ wird in Zusammenarbeit mit der Fa. Daimler-Chrysler vorgestellt, die mit ihrer EOS Sinteranlage ein Benchmarkwerkzeug mit konturnaher Kühlung gefertigt haben. Das “Indirect Metal Laser Sintering“ wird an der Universität Duisburg-Essen angewandt. Hier wurden diverse Bauteile bzw. Gesenke in Zusammenarbeit mit der Fa. Powercut oder dem ZBT hergestellt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Uptake of eugenol from eugenol-containing temporary materials may reduce the adhesion of subsequent resin-based restorations. This study investigated the effect of duration of exposure to zinc oxide–eugenol (ZOE) cement on the quantity of eugenol retained in dentin and on the microtensile bond strength (μTBS) of the resin composite. The ZOE cement (IRM Caps) was applied onto the dentin of human molars (21 per group) for 1, 7, or 28 d. One half of each molar was used to determine the quantity of eugenol (by spectrofluorimetry) and the other half was used for μTBS testing. The ZOE-exposed dentin was treated with either OptiBond FL using phosphoric acid (H3PO4) or with Gluma Classic using ethylenediaminetetraacetic acid (EDTA) conditioning. One group without conditioning (for eugenol quantity) and two groups not exposed to ZOE (for eugenol quantity and μTBS testing) served as controls. The quantity of eugenol ranged between 0.33 and 2.9 nmol mg−1 of dentin (median values). No effect of the duration of exposure to ZOE was found. Conditioning with H3PO4 or EDTA significantly reduced the quantity of eugenol in dentin. Nevertheless, for OptiBond FL, exposure to ZOE significantly decreased the μTBS, regardless of the duration of exposure. For Gluma Classic, the μTBS decreased after exposure to ZOE for 7 and 28 d. OptiBond FL yielded a significantly higher μTBS than did Gluma Classic. Thus, ZOE should be avoided in cavities later to be restored with resin-based materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Eosinophilic esophagitis (EoE) is a chronic, Th2-type inflammatory disease. Chemoattractant receptor-homologous molecule on Th2 cells (CRTH2) is a prostaglandin D(2) (PGD(2)) receptor, expressed by Th2 cells and other inflammatory cells, including eosinophils and basophils, that mediates chemotaxis and activation. OC000459 is a selective CRTH2 antagonist and would be expected to suppress eosinophilic tissue inflammation. The purpose of this study was to evaluate the efficacy and safety of an OC000459 monotherapy in adult patients with active, corticosteroid-dependent or corticosteroid-refractory EoE. METHODS: In this randomized, double-blind, placebo-controlled trial, 26 adult patients (m/f = 22/4; mean age 41 years, range 22-69 years) with active EoE, dependent or resistant to corticosteroids, were treated either with 100 mg OC000459 (n = 14) or placebo (n = 12) twice daily. Pre- and post-treatment disease activity was assessed clinically, endoscopically, histologically, and via biomarkers. The primary end point was the reduction in esophageal eosinophil infiltration. RESULTS: After an 8-week OC000459 treatment, the esophageal eosinophil load decreased significantly, from 114.83 to 73.26 eosinophils per high-power field [(eos/hpf), P = 0.0256], whereas no reduction was observed with placebo (102.80-99.47 eos/hpf, P = 0.870). With OC000459, the physician's global assessment of disease activity improved from 7.13 to 5.18 (P = 0.035). OC000459 likewise reduced extracellular deposits of eosinophil peroxidase and tenascin C, the effects not seen with placebo. No serious adverse events were observed. CONCLUSIONS: An 8-week treatment with the CRTH2-antagonist, OC000459, exerts modest, but significant, anti-eosinophil and beneficial clinical effects in adult patients with active, corticosteroid-dependent or corticosteroid-refractory EoE and is well tolerated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the reporting completeness of systematic review (SR) abstracts in leading dental specialty journals. Electronic and supplementary hand searching were undertaken to identify SRs published in seven dental specialty journals and in the Cochrane Database of Systematic Reviews. Abstract reporting completeness was evaluated using a checklist derived from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (prisma) guidelines. Descriptive statistics followed by univariate and multivariate analyses were conducted. Two-hundred and eighteen SR abstracts were identified. Reporting of interventions (94%), objectives (96%), data sources (81%), eligibility criteria (77%), and conclusions (97%) was adequate in the majority of reviews. However, inadequate reporting of participants (18%), results (42%), effect size (14%), level of significance (60%), and trial registration (100%) was commonplace. The mean overall reporting score was 79.1% (95% CI, 77.6-80.6). Only journal of publication was a significant predictor of overall reporting, with inferior results for all journals relative to Cochrane reviews, with scores ranging from -4.3% (95% CI, -8.74 to 0.08) to -35.6% (95% CI, -42.0 to -24.3) for the International Journal of Prosthodontics and the British Journal of Oral and Maxillofacial Surgery, respectively. Improved reporting of dental SR abstracts is needed and should be encouraged, as these abstracts may underpin influential clinical decisions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM To compare the computed tomography (CT) dose and image quality with the filtered back projection against the iterative reconstruction and CT with a minimal electronic noise detector. METHODS A lung phantom (Chest Phantom N1 by Kyoto Kagaku) was scanned with 3 different CT scanners: the Somatom Sensation, the Definition Flash and the Definition Edge (all from Siemens, Erlangen, Germany). The scan parameters were identical to the Siemens presetting for THORAX ROUTINE (scan length 35 cm and FOV 33 cm). Nine different exposition levels were examined (reference mAs/peek voltage): 100/120, 100/100, 100/80, 50/120, 50/100, 50/80, 25/120, 25/100 and 25 mAs/80 kVp. Images from the SOMATOM Sensation were reconstructed using classic filtered back projection. Iterative reconstruction (SAFIRE, level 3) was performed for the two other scanners. A Stellar detector was used with the Somatom Definition Edge. The CT doses were represented by the dose length products (DLPs) (mGycm) provided by the scanners. Signal, contrast, noise and subjective image quality were recorded by two different radiologists with 10 and 3 years of experience in chest CT radiology. To determine the average dose reduction between two scanners, the integral of the dose difference was calculated from the lowest to the highest noise level. RESULTS When using iterative reconstruction (IR) instead of filtered back projection (FBP), the average dose reduction was 30%, 52% and 80% for bone, soft tissue and air, respectively, for the same image quality (P < 0.0001). The recently introduced Stellar detector (Sd) lowered the radiation dose by an additional 27%, 54% and 70% for bone, soft tissue and air, respectively (P < 0.0001). The benefit of dose reduction was larger at lower dose levels. With the same radiation dose, an average of 34% (22%-37%) and 25% (13%-46%) more contrast to noise was achieved by changing from FBP to IR and from IR to Sd, respectively. For the same contrast to noise level, an average of 59% (46%-71%) and 51% (38%-68%) dose reduction was produced for IR and Sd, respectively. For the same subjective image quality, the dose could be reduced by 25% (2%-42%) and 44% (33%-54%) using IR and Sd, respectively. CONCLUSION This study showed an average dose reduction between 27% and 70% for the new Stellar detector, which is equivalent to using IR instead of FBP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

High-performance thermoplastics including polyetheretherketone (PEEK) are key biomaterials for load-bearing implants. Plasma treatment of implants surfaces has been shown to chemically activate its surface, which is a prerequisite to achieve proper cell attachment. Oxygen plasma treatment of PEEK films results in very reproducible surface nanostructures and has been reported in the literature. Our goal is to apply the plasma treatment to another promising polymer, polyetherketoneketone (PEKK), and compare its characteristics to the ones of PEEK. Oxygen plasma treatments of plasma powers between 25 and 150 W were applied on 60 μm-thick PEKK and 100 μm-thick PEEK films. Analysis of the nanostructures by atomic force microscopy showed that the roughness increased and island density decreased with plasma power for both PEKK and PEEK films correlating with contact angle values without affecting bulk properties of the used films. Thermal analysis of the plasma-treated films shows that the plasma treatment does not change the bulk properties of the PEKK and PEEK films.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The geometric characterization of low-voltage dielectric electro-active polymer (EAP) structures, comprised of nanometer thickness but areas of square centimeters, for applications such as artificial sphincters requires methods with nanometer precision. Direct optical detection is usually restricted to sub-micrometer resolution because of the wavelength of the light applied. Therefore, we propose to take advantage of the cantilever bending system with optical readout revealing a sub-micrometer resolution at the deflection of the free end. It is demonstrated that this approach allows us to detect bending of rather conventional planar asymmetric, dielectric EAP-structures applying voltages well below 10 V. For this purpose, we built 100 μm-thin silicone films between 50 nm-thin silver layers on a 25 μm-thin polyetheretherketone (PEEK) substrate. The increase of the applied voltage in steps of 50 V until 1 kV resulted in a cantilever bending that exhibits only in restricted ranges the expected square dependence. The mean laser beam displacement on the detector corresponded to 6 nm per volt. The apparatus will therefore become a powerful mean to analyze and thereby improve low-voltage dielectric EAP-structures to realize nanometer-thin layers for stack actuators to be incorporated into artificial sphincter systems for treating severe urinary and fecal incontinence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polymer implants are interesting alternatives to the contemporary load-bearing implants made from metals. Polyetheretherketone (PEEK), a well-established biomaterial for example, is not only iso-elastic to bone but also permits investigating the surrounding soft tissues using magnetic resonance imaging or computed tomography, which is particularly important for cancer patients. The commercially available PEEK bone implants, however, require costly coatings, which restricts their usage. As an alternative to coatings, plasma activation can be applied. The present paper shows the plasma-induced preparation of nanostructures on polymer films and on injection-molded micro-cantilever arrays and the associated chemical modifications of the surface. In vitro cell experiments indicate the suitability of the activation process. In addition, we show that microstructures such as micro-grooves 1 μm deep and 20 μm wide cause cell alignment. The combination of micro-injection molding, simultaneous microstructuring using inserts/bioreplica and plasma treatments permits the preparation of polymer implants with nature-analogue, anisotropic micro- and nanostructures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since November 1994, the GROund-based Millimeter-wave Ozone Spectrometer (GROMOS) measures stratospheric and lower mesospheric ozone in Bern, Switzerland (47.95° N, 7.44° E). GROMOS is part of the Network for the Detection of Atmospheric Composition Change (NDACC). In July 2009, a Fast-Fourier-Transform spectrometer (FFTS) has been added as backend to GROMOS. The new FFTS and the original filter bench (FB) measured parallel for over two years. In October 2011, the FB has been turned off and the FFTS is now used to continue the ozone time series. For a consolidated ozone time series in the frame of NDACC, the quality of the stratospheric ozone profiles obtained with the FFTS has to be assessed. The FFTS results from July 2009 to December 2011 are compared to ozone profiles retrieved by the FB. FFTS and FB of the GROMOS microwave radiometer agree within 5% above 20 hPa. A later harmonization of both time series will be realized by taking the FFTS as benchmark for the FB. Ozone profiles from the FFTS are also compared to coinciding lidar measurements from the Observatoire Haute Provence (OHP), France. For the time period studied a maximum mean difference (lidar – GROMOS FFTS) of +3.8% at 3.1 hPa and a minimum mean difference of +1.4% at 8 hPa is found. Further, intercomparisons with ozone profiles from other independent instruments are performed: satellite measurements include MIPAS onboard ENVISAT, SABER onboard TIMED, MLS onboard EOS Aura and ACE-FTS onboard SCISAT-1. Additionally, ozonesondes launched from Payerne, Switzerland, are used in the lower stratosphere. Mean relative differences of GROMOS FFTS and these independent instruments are less than 10% between 50 and 0.1 hPa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess patterns and correlates of family variables in 31 adolescents treated for their first episode of a schizophrenia spectrum disorder (early-onset schizophrenia [EOS]). Expressed emotion, perceived criticism, and rearing style were assessed. Potential correlates were patient psychopathology, premorbid adjustment, illness duration, quality of life (QoL), sociodemographic variables, patient and caregiver "illness concept," and caregiver personality traits and support. Families were rated as critical more frequently by patients than raters (55% vs. 13%). Perceived criticism was associated with worse QoL in relationship with parents and peers. An adverse rearing style was associated with a negative illness concept in patients, particularly with less trust in their physician. Future research should examine perceived criticism as a predictor of relapse and indicator of adolescents with EOS who need extended support and treatment. Rearing style should be carefully observed because of its link with patients' illness concept and, potentially, to service engagement and medication adherence

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION Empirical evidence has indicated that only a subsample of studies conducted reach full-text publication and this phenomenon has become known as publication bias. A form of publication bias is the selectively delayed full publication of conference abstracts. The objective of this article was to examine the publication status of oral abstracts and poster-presentation abstracts, included in the scientific program of the 82nd and 83rd European Orthodontic Society (EOS) congresses, held in 2006 and 2007, and to identify factors associated with full-length publication. METHODS A systematic search of PubMed and Google Scholar databases was performed in April 2013 using author names and keywords from the abstract title to locate abstract and full-article publications. Information regarding mode of presentation, type of affiliation, geographical origin, statistical results, and publication details were collected and analyzed using univariable and multivariable logistic regression. RESULTS Approximately 51 per cent of the EOS 2006 and 55 per cent of the EOS 2007 abstracts appeared in print more than 5 years post congress. A mean period of 1.32 years elapsed between conference and publication date. Mode of presentation (oral or poster), use of statistical analysis, and research subject area were significant predictors for publication success. LIMITATIONS Inherent discrepancies of abstract reporting, mainly related to presentation of preliminary results and incomplete description of methods, may be considered in analogous studies. CONCLUSIONS On average 52.2 per cent of the abstracts presented at the two EOS conferences reached full publication. Abstracts presented orally, including statistical analysis, were more likely to get published.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to determine if storage for up to 4 h in human saliva results in a decrease of erosive tooth wear (ETW) and in an increase of surface microhardness (SMH) of enamel samples after an erosive attack with subsequent abrasion. Furthermore, we determined the impact of individual salivary parameters on ETW and SMH. Enamel samples were distributed into five groups: group 1 had neither erosion nor saliva treatment; groups 2-5 were treated with erosion, then group 2 was placed in a humid chamber and groups 3-5 were incubated in saliva for 30 min, 2 h, and 4 h, respectively. After erosion and saliva treatments, all groups were treated with abrasion. Surface microhardness and ETW were measured before and after erosion, incubation in saliva, and abrasion. Surface microhardness and ETW showed significant changes throughout the experiment: SMH decreased and ETW increased in groups 2-5, regardless of the length of incubation in saliva. The results of groups 3-5 (exposed to saliva) were not significantly different from those of group 2 (not exposed to saliva). Exposure of eroded enamel to saliva for up to 4 h was not able to increase SMH or reduce ETW. However, additional experiments with artificial saliva without proteins showed protection from erosive tooth wear. The recommendation to postpone toothbrushing of enamel after an erosive attack should be reconsidered.