890 resultados para Discrete-time sliding mode control


Relevância:

100.00% 100.00%

Publicador:

Resumo:

On using McKenzie’s taxonomy of optimal accumulation in the longrun, we report a “uniform turnpike” theorem of the third kind in a model original to Robinson, Solow and Srinivasan (RSS), and further studied by Stiglitz. Our results are presented in the undiscounted, discrete-time setting emphasized in the recent work of Khan-Mitra, and they rely on the importance of strictly concave felicity functions, or alternatively, on the value of a “marginal rate of transformation”, ξσ, from one period to the next not being unity. Our results, despite their specificity, contribute to the methodology of intertemporal optimization theory, as developed in economics by Ramsey, von Neumann and their followers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In 1991 Gary S. Becker presented A Note on Restaurant Pricing and Other Examples of Social In uences on Price explaining why many successful restaurants, plays, sporting events, and other activities do not raise their prices even with persistent excess demand. The main reason for this is due to the discontinuity of stable demands, which is explained in Becker's (1991) analysis. In the present paper we construct a discrete time stochastic model of socially interacting consumers deciding for one of two establishments. With this model we show that the discontinuity of stable demands, proposed by Gary S. Becker, depends crucially on an additional factor: the dispersion of the consumers' intrinsic preferences for the establishments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho propõe um novo modelo para avaliação, em tempo discreto, do desconto de reequilíbrio em contratos de concessão rodoviária, a partir de conceitos da Teoria Clássica de Finanças e da Teoria de Opções Reais. O modelo desenvolvido permitiu incorporar flexibilidades decorrentes de incertezas nas situações reais, como decisões gerenciais, vieses de comportamento e componentes políticos, comumente presentes em contratos de concessões rodoviária. Os resultados obtidos, utilizando-se como estudo de caso a BR-262, sinalizaram que há espaço para uma melhor intervenção regulatória com relação ao mecanismo do desconto de reequilíbrio, no sentido de prover melhores incentivos aos concessionários.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As condições de ambiente térmico e aéreo, no interior de instalações para animais, alteram-se durante o dia, devido à influência do ambiente externo. Para que análises estatísticas e geoestatísticas sejam representativas, uma grande quantidade de pontos distribuídos espacialmente na área da instalação deve ser monitorada. Este trabalho propõe que a variação no tempo das variáveis ambientais de interesse para a produção animal, monitoradas no interior de instalações para animais, pode ser modelada com precisão a partir de registros discretos no tempo. O objetivo deste trabalho foi desenvolver um método numérico para corrigir as variações temporais dessas variáveis ambientais, transformando os dados para que tais observações independam do tempo gasto durante a aferição. O método proposto aproximou os valores registrados com retardos de tempo aos esperados no exato momento de interesse, caso os dados fossem medidos simultaneamente neste momento em todos os pontos distribuídos espacialmente. O modelo de correção numérica para variáveis ambientais foi validado para o parâmetro ambiental temperatura do ar, sendo que os valores corrigidos pelo método não diferiram pelo teste Tukey, a 5% de probabilidade dos valores reais registrados por meio de dataloggers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work determined the efficacy of the insecticide methyl parathion and the natural pesticide azadirachtin present in the aqueous extract of dry neem leaves (AEDNL) to Anacanthorus penilabiatus (Monogenoidea) control in pacu (Piaractus mesopotamicus). The efficacy of methyl parathion was evaluated in an experiment consisting of six treatments (0.0, 3.0, 4.0, 5.0, 6.0 and 7.0 mg methyl parathion/L water) and five exposure times (2, 4, 8, 16 and 24 h). The efficacy of azadirachtin present in AEDNL was assessed in an experiment consisting of seven treatments (0,0; 25; 50; 75; 100; 125; e 150 mL/L water) and five exposure times (24, 48, 72, 96 and 120 h). The efficacy of methyl parathion increased with increasing concentration and exposure time. The highest control efficacy was obtained with a concentration of 7 mg methyl parathion/L at all exposure times. In this treatment, the highest efficacies were observed at 16 and 24 h of exposure, with a control rate of 96.2 and 97.0%, respectively. For the AEDNL, the highest control efficacy (89.2%) was obtained with a concentration of 2.9 mg/L after 120 h of exposure. The efficacy in the treatments employing 1.47 and 1.18 mg/L was 83.9 and 82.5%, respectively, after 120 h of exposure. Methyl parathion presented a higher efficacy in the control of A. penilabiatus than the AEDNL. The AEDNL was moderately effective in the control of the parasite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este projeto teve por objetivo avaliar a eficácia de herbicidas para controle de plantas aquáticas submersas das espécies Egeria densa e Egeria najas. O estudo foi realizado em três etapas consecutivas: em laboratório, em caixas d'água e numa represa de pequeno porte, sem fluxo de água. Na primeira etapa, avaliou-se a eficiência de 23 herbicidas utilizados em áreas agrícolas e disponíveis no mercado brasileiro. As elevadas concentrações em que os herbicidas foram efetivos inviabilizam programas de controle fundamentados em uma única aplicação. No experimento em caixas d'água, foram avaliados os efeitos de doses crescentes de fluridone, nas formulações líquida e granulada, no controle de Egeria densa e Egeria najas. Foram testadas as concentrações de 10, 20, 40, 80 e 150 ppb de fluridone na formulação líquida e 20, 40, 80 e 150 ppb na granulada. Após uma única aplicação, os resultados indicaram que o fluridone, nas concentrações de 80 e 150 ppb, em ambas as formulações, foi eficaz no controle dessas duas espécies. No experimento em represa de pequeno porte sem fluxo de água, avaliou-se o efeito da manutenção das concentrações de fluridone no controle de Egeria najas. Uma represa de 1.980 m² foi tratada com sete aplicações de fluridone, na formulação líquida, visando a manutenção das concentrações do ingrediente ativo na água entre 10 e 20 ppb. Os resultados indicaram que o controle proporcionado pelo herbicida foi superior a 99%. Não houve modificação significativa nas características relacionadas à qualidade da água.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper deals with a stochastic stability concept for discrete-time Markovian jump linear systems. The random jump parameter is associated to changes between the system operation modes due to failures or repairs, which can be well described by an underlying finite-state Markov chain. In the model studied, a fixed number of failures or repairs is allowed, after which, the system is brought to a halt for maintenance or for replacement. The usual concepts of stochastic stability are related to pure infinite horizon problems, and are not appropriate in this scenario. A new stability concept is introduced, named stochastic tau-stability that is tailored to the present setting. Necessary and sufficient conditions to ensure the stochastic tau-stability are provided, and the almost sure stability concept associated with this class of processes is also addressed. The paper also develops equivalences among second order concepts that parallels the results for infinite horizon problems. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a novel single-phase high-power-factor (HPF) pulsewidth-modulated (PWM) boost rectifier featuring soft commutation of the active switches at zero current (ZC), It incorporates the most desirable properties of conventional PWM and soft-switching resonant techniques.The input current shaping is achieved with average current mode control and continuous inductor current mode.This new PWM converter provides ZC turn on and turn off of the active switches, and it is suitable for high-power applications employing insulated gate bipolar transistors (IGBT's),The principle of operation, the theoretical analysis, a design example, and experimental results from a laboratory prototype rated at 1600 W with 400-Vdc output voltage are presented. The measured efficiency and the power factor were 96.2% and 0.99%, respectively, with an input current total harmonic distortion (THD) equal to 3.94%, for an input voltage with THD equal to 3.8%, at rated load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an analysis of a novel pulse-width-modulated (PWM) voltage step-down/up Zeta converter, featuring zero-current-switching (ZCS) at the active switches. The applications in de to de and ac to de (rectifier) operation modes are used as examples to illustrate the performance of this new ZCS-PWM Zeta converter. Regarding to the new ZCS-PWM Zeta rectifier proposed, it should be noticed that the average-current mode control is used in order to obtain a structure with high power-factor (HPF) and low total harmonic distortion (THD) at the input current.Two active switches (main and auxiliary transistors), two diodes, two small resonant inductors and one small resonant capacitor compose the novel ZCS-PWM soft-commutation cell, used in these new ZCS-PWM Zeta converters. In this cell, the turn-on of the active switches occurs in zero-current (ZC) and their turn-off in zero-current and zero-voltage (ZCZV). For the diodes, their turn-on process occurs in zero-voltage (ZV) and their reverse-recovery effects over the active switches are negligible. These characteristics make this cell suitable for Insulated-Gate Bipolar Transistors (IGBTs) applications.The main advantages of these new Zeta converters, generated from the new soft-commutation cell proposed, are possibility of obtaining isolation (through their accumulation inductors), and high efficiency, at wide load range. In addition, for the rectifier application, a high power factor and low THD in the input current ran be obtained, in agreement with LEC 1000-3-2 standards.The principle of operation, the theoretical analysis and a design example for the new de to de Zeta converter operating in voltage step-down mode are presented. Experimental results are obtained from a test unit with 500W output power, 110V(dc) output voltage, 220V(dc) input voltage, operating at 50kHz switching frequency. The efficiency measured at rated toad is equal to 97.3%for this new Zeta converter.Finally, the new Zeta rectifier is analyzed, and experimental results from a test unit rated at 500W output power, 110V(dc) output voltage, 220V(rms) input voltage, and operating at 50kHz switching frequency, are presented. The measured efficiency is equal to 96.95%, the power-factor is equal to 0.98, and the input current THD is equal to 19.07%, for this new rectifier operating at rated load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces novel zero-current-switching (ZCS) pulsewidth-modulated (PWM) preregulators based on a new soft-commutation cell, suitable for insulated gate bipolar transistor applications. The active switches in these proposed rectifiers turn on in zero current and turn off in zero current-zero voltage. In addition, the diodes turn on in zero voltage and their reverse-recovery effects over the active switches are negligible. Moreover, based on the proposed cell, an entire family of de-to-de ZCS-PWM converters can be generated, providing conditions to obtain naturally isolated converters, for example, derived buck-boost, Sepic. and Zeta converters. The novel ac-to-dc ZCS-PWM boost and Zeta preregulators are presented in order to verify the operation of this soft-commutation cell, In order to minimize the harmonic contents of the input current, increasing the ac power factor, the average-current-mode control is used, obtaining preregulators with ac power factor near unity and high efficiency at wide load range. The principle of operation, theoretical analysis, design example, and experimental results from test units for the novel preregulators are presented. The new boost preregulator was designed to nominal values of 1.6 kW output power, 220 V(rms) input voltage, 400 V(dc) output voltage, and operating at 20 kHz. The measured efficiency and power factor of the new ZCS-PWM boost preregulator were 96.7% and 0,99, respectively, with an input current total harmonic distortion (THD) equal to 3.42% for an input voltage with THD equal to 1.61%, at rated load, the new ZCS-PWM Zeta preregulator was designed to voltage step-down operation, and the experimental results were obtained from a laboratory prototype rated at 500 W, 220 V(rm), input voltage, 110 V(dc) output voltage, and operating at 50 kHz. The measured efficiency of the new ZCS-PWM Zeta preregulator is approximately 96.9% and the input power factor is 0.98, with an input current THD equal to 19.07% while the input voltage THD is equal to 1.96%, at rated load.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the work reported here we present theoretical and numerical results about a Risk Model with Interest Rate and Proportional Reinsurance based on the article Inequalities for the ruin probability in a controlled discrete-time risk process by Ros ario Romera and Maikol Diasparra (see [5]). Recursive and integral equations as well as upper bounds for the Ruin Probability are given considering three di erent approaches, namely, classical Lundberg inequality, Inductive approach and Martingale approach. Density estimation techniques (non-parametrics) are used to derive upper bounds for the Ruin Probability and the algorithms used in the simulation are presented

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)