957 resultados para Diffraction losses
Resumo:
The mechanical harvesting is an important stage in the production process of soybeans and, in this process; the loss of a significant number of grains is common. Despite the existence of mechanisms to monitor these losses, it is still essential to use sampling methods to quantify them. Assuming that the size of the sample area affects the reliability and variability between samples in quantifying losses, this paper aimed to analyze the variability and feasibility of using different sizes of sample area (1, 2 and 3 m²) in quantifying losses in the mechanical harvesting of soybeans. Were sampled 36 sites and the cutting losses, losses by other mechanisms of the combine and total losses were evaluated, as well as the water content in seeds, straw distribution and crop productivity. Data were subjected to statistical analysis (descriptive statistics and analysis of variance) and Statistical Control Process (SCP). The coefficients of variation were similar for the three frames available. Combine losses showed stable behavior, whereas cutting losses and total losses showed unstable behavior. The frame size did not affect the quantification and variability of losses in the mechanical harvesting of soybeans, thus a frame of 1 m² can be used for determining losses.
Resumo:
Our hypothesis was that increasing the length of an estradiol and progesterone (P4) timed artificial insemination (TAI) protocol would improve pregnancy per artificial insemination (P/AI). Lactating Holstein cows (n = 759) yielding 31 +/- 0.30 kg of milk/d with a detectable corpus luteum (CL) at d - 11 were randomly assigned to receive TAI (d 0) following 1 of 2 treatments: (8d) d - 10 controlled internal drug release (CIDR) and 2.0 mg of estradiol benzoate, d - 3 = PGF(2 alpha) (25 mg of dinoprost tromethamine), d - 2 = CIDR removal and 1.0 mg of estradiol cypionate, d 0 = TAI; or (9d) d - 11 = CIDR and estradiol benzoate, d -4 = PGF(2 alpha), d -2 CIDR removal and estradiol cypionate, d 0 TAI. Cows were considered to have their estrous cycle synchronized in response to the protocol by the absence of a CL at artificial insemination (d 0) and presence of a CL on d 7. Pregnancy diagnoses were performed on d 32 and 60. The ovulatory follicle diameter at TAI (d 0) did not differ between treatments (14.7 +/- 0.39 vs. 15.0 +/- 0.40 mm for 8 and 9 d, respectively). The 9d cows tended to have greater P4 concentrations on d 7 in synchronized cows (3.14 +/- 0.18 ng/mL) than the 8d cows (3.05 +/- 0.18 ng/mL). Although the P/AI at d 32 [45 (175/385) vs. 43.9% (166/374) for 8d and 9d, respectively] and 60 [38.1 (150/385) vs. 40.4% (154/374) for 8d and 9d, respectively] was not different, the 9d cows had lower pregnancy losses [7.6% (12/166)] than 8d cows [14.7% (25/175)]. The cows in the 9d program were more likely to be detected in estrus [72.0% (269/374)] compared with 8d cows [62% (240/385)]. Expression of estrus improved synchronization [97.4 (489/501) vs. 81% (202/248)], P4 concentrations at d 7 (3.22 +/- 0.16 vs. 2.77 +/- 0.17 ng/mL), P/AI at d 32 [51.2 (252/489) vs. 39.4% (81/202)], P/AI at d 60 [46.3 (230/489) vs. 31.1% (66/202)], and decreased pregnancy loss [9.3 (22/252) vs. 19.8% (15/81)] compared with cows that did not show estrus, respectively. Cows not detected in estrus with small (<11 mm) or large follicles (>17 mm) had greater pregnancy loss; however, in cows detected in estrus, no effect of follicle diameter on pregnancy loss was observed. In conclusion, increasing the length of the protocol for TAI increased the percentage of cows detected in estrus and decreased pregnancy loss.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Microwave-assisted hydrothermal synthesis of NiO-Ce1-XEuxO2-δ powders for fuel cell catalytic anodes
Resumo:
CeO2-based materials doped with rare earth (TR +3) can be used as alternative to traditional NiO-YSZ anodes in solid oxide fuel cells as they have higher ionic conductivity and lower ohmic losses compared to YSZ. Moreover, they allow fuel cell operation at lower temperatures (500-800°C). In the anode composition, the concentration of NiO acting as catalyst in YSZ provides high electrical conductivity and high electrochemical activity of reactions, promoting internal reform in the cell. In this work, NiO - Ce1-xEuxO2-δ compounds (x = 0.1, 0.2 and 0.3) have been synthesized by microwave-assisted hydrothermal method. The materials were characterized by TG, XRD, TPR and SEM-FEG techniques. The refinement of data obtained by X-ray diffraction showed the presence of ceria doped with europium crystallized in a cubic phase with fluorite structure, in addition to the presence of NiO. The microwave-assisted hydrothermal method showed significant reduction in the average particle size and good mass control of phase compositions compared to other chemical synthesis techniques.
Resumo:
Electric power distribution systems, and particularly those with overhead circuits, operate radially but as the topology of the systems is meshed, therefore a set of circuits needs to be disconnected. In this context the problem of optimal reconfiguration of a distribution system is formulated with the goal of finding a radial topology for the operation of the system. This paper utilizes experimental tests and preliminary theoretical analysis to show that radial topology is one of the worst topologies to use if the goal is to minimize power losses in a power distribution system. For this reason, it is important to initiate a theoretical and practical discussion on whether it is worthwhile to operate a distribution system in a radial form. This topic is becoming increasingly important within the modern operation of electrical systems, which requires them to operate as efficiently as possible, utilizing all available resources to improve and optimize the operation of electric power systems. Experimental tests demonstrate the importance of this issue. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
A polymeric precursor solution was used to deposit pure and Mg doped LiNbO3 thin films on sapphire substrates by spin-coating. The effects of magnesium addition on crystallinity, morphology and optical properties of the annealed films were investigated. X-ray diffraction patterns indicate the oriented growth of the films. Phi-scan diffraction evidenced the epitaxial growth with two in-plane variants. AFM studies show that the films are very homogeneous, dense and present smooth surfaces. The refractive index and optical losses obtained by the prism coupling method were influenced by the magnesium addition.
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Gaseous losses are the main factors affecting the efficiency of nitrogenous fertilizers in pastures. To evaluate NH3-N volatilization losses in Tanzania grass fertilized with urea in autumn, spring and summer, a completely randomized design with repeated measurements over time and fifteen replicates was used. Plots were represented by urea levels (50; 100 and 150 kg ha-1 N) and subplots by time after fertilization (1; 2; 3; 6; 9; 12 and 15 days). The interaction between fertilization leveland time after urea application was significant for the accumulated NH3-N volatilization. Urea application leads to higher percentage N losses in the first three days after application. The average cumulative NH3- N loss for the three occasions (different seasons of the year) was 28%, 20% and 16% of N applied for fertilizer doses of 50; 100 and 150 kg ha-1 of N, respectively. The season of the year influenced NH3-N loss pattern and volume, with the lowest values recorded in spring, followed by summer and autumn. The cumulative NH3-N volatilization loss varies from 78 to 90% up to the third day after application of the total NNH3 loss.