998 resultados para Diagnostic Algorithms


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OsteoLaus is a cohort of 1400 women 50 to 80 years living in Lausanne, Switzerland. Clinical risk factors for osteoporosis, bone ultrasound of the heel, lumbar spine and hip bone mineral density (BMD), assessment of vertebral fracture by DXA, and microarchitecture evaluation by TBS (Trabecular Bone Score) will be recorded. TBS is a new parameter obtained after a re-analysis of a DXA exam. TBS is correlated with parameters of microarchitecture. His reproducibility is good. TBS give an added diagnostic value to BMD, and predict osteoporotic fracture (partially) independently to BMD. The position of TBS in clinical routine in complement to BMD and clinical risk factors will be evaluated in the OsteoLaus cohort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND/OBJECTIVES: (1) To cross-validate tetra- (4-BIA) and octopolar (8-BIA) bioelectrical impedance analysis vs dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition and (2) to evaluate the accuracy of external 4-BIA algorithms for the prediction of total body composition, in a representative sample of Swiss children. SUBJECTS/METHODS: A representative sample of 333 Swiss children aged 6-13 years from the Kinder-Sportstudie (KISS) (ISRCTN15360785). Whole-body fat-free mass (FFM) and appendicular lean tissue mass were measured with DXA. Body resistance (R) was measured at 50 kHz with 4-BIA and segmental body resistance at 5, 50, 250 and 500 kHz with 8-BIA. The resistance index (RI) was calculated as height(2)/R. Selection of predictors (gender, age, weight, RI4 and RI8) for BIA algorithms was performed using bootstrapped stepwise linear regression on 1000 samples. We calculated 95% confidence intervals (CI) of regression coefficients and measures of model fit using bootstrap analysis. Limits of agreement were used as measures of interchangeability of BIA with DXA. RESULTS: 8-BIA was more accurate than 4-BIA for the assessment of FFM (root mean square error (RMSE)=0.90 (95% CI 0.82-0.98) vs 1.12 kg (1.01-1.24); limits of agreement 1.80 to -1.80 kg vs 2.24 to -2.24 kg). 8-BIA also gave accurate estimates of appendicular body composition, with RMSE < or = 0.10 kg for arms and < or = 0.24 kg for legs. All external 4-BIA algorithms performed poorly with substantial negative proportional bias (r> or = 0.48, P<0.001). CONCLUSIONS: In a representative sample of young Swiss children (1) 8-BIA was superior to 4-BIA for the prediction of FFM, (2) external 4-BIA algorithms gave biased predictions of FFM and (3) 8-BIA was an accurate predictor of segmental body composition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this project a research both in finding predictors via clustering techniques and in reviewing the Data Mining free software is achieved. The research is based in a case of study, from where additionally to the KDD free software used by the scientific community; a new free tool for pre-processing the data is presented. The predictors are intended for the e-learning domain as the data from where these predictors have to be inferred are student qualifications from different e-learning environments. Through our case of study not only clustering algorithms are tested but also additional goals are proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Functional brain images such as Single-Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) have been widely used to guide the clinicians in the Alzheimer's Disease (AD) diagnosis. However, the subjectivity involved in their evaluation has favoured the development of Computer Aided Diagnosis (CAD) Systems. METHODS It is proposed a novel combination of feature extraction techniques to improve the diagnosis of AD. Firstly, Regions of Interest (ROIs) are selected by means of a t-test carried out on 3D Normalised Mean Square Error (NMSE) features restricted to be located within a predefined brain activation mask. In order to address the small sample-size problem, the dimension of the feature space was further reduced by: Large Margin Nearest Neighbours using a rectangular matrix (LMNN-RECT), Principal Component Analysis (PCA) or Partial Least Squares (PLS) (the two latter also analysed with a LMNN transformation). Regarding the classifiers, kernel Support Vector Machines (SVMs) and LMNN using Euclidean, Mahalanobis and Energy-based metrics were compared. RESULTS Several experiments were conducted in order to evaluate the proposed LMNN-based feature extraction algorithms and its benefits as: i) linear transformation of the PLS or PCA reduced data, ii) feature reduction technique, and iii) classifier (with Euclidean, Mahalanobis or Energy-based methodology). The system was evaluated by means of k-fold cross-validation yielding accuracy, sensitivity and specificity values of 92.78%, 91.07% and 95.12% (for SPECT) and 90.67%, 88% and 93.33% (for PET), respectively, when a NMSE-PLS-LMNN feature extraction method was used in combination with a SVM classifier, thus outperforming recently reported baseline methods. CONCLUSIONS All the proposed methods turned out to be a valid solution for the presented problem. One of the advances is the robustness of the LMNN algorithm that not only provides higher separation rate between the classes but it also makes (in combination with NMSE and PLS) this rate variation more stable. In addition, their generalization ability is another advance since several experiments were performed on two image modalities (SPECT and PET).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to identify specific markers that mirror liver fibrosis progression as an alternative to biopsy when biopsy is contraindicated, especially in children. After liver biopsies were performed, serum samples from 30 hepatitis C virus (HCV) paediatric patients (8-14 years) were analysed and compared with samples from 30 healthy subjects. All subjects were tested for the presence of serum anti-HCV antibodies. Direct biomarkers for liver fibrosis, including transforming growth factor-β1, tissue inhibitor of matrix metalloproteinase-1 (TIMP-1), hyaluronic acid (HA), procollagen type III amino-terminal peptide (PIIINP) and osteopontin (OPN), were measured. The indirect biomarkers aspartate and alanine aminotransferases, albumin and bilirubin were also tested. The results revealed a significant increase in the serum marker levels in HCV-infected children compared with the healthy group, whereas albumin levels exhibited a significant decrease. Significantly higher levels of PIIINP, TIMP-1, OPN and HA were detected in HCV-infected children with moderate to severe fibrosis compared with children with mild fibrosis (p < 0.05). The diagnostic accuracy of these direct biomarkers, represented by sensitivity, specificity and positive predictive value, emphasises the utility of PIIINP, TIMP-1, OPN and HA as indicators of liver fibrosis among HCV-infected children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents an improvement to the Kato-Katz (KK) method, making it faster and more efficient for the visualisation of fertile eggs in stool samples. This modified KK method uses sodium acetate formalin as a fixative and reveals the intensity of infection in less than 1 h, reducing the diagnostic time without increasing the cost. This modified method may contribute to future epidemiological studies in both hospitals and the field due to its rapid and precise diagnostic, which allow for immediate treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative effectiveness research (CER) allows evidence to be evaluated on the effectiveness, benefits, and detriments of management options, diagnostic tests, or ways to deliver health care. This process can be achieved in different ways, such as with well-designed randomized controlled trials or by meta-analyses. Several medical subspecialties are increasingly using CER, but CER remains underused by the neurosurgical community. Meta-analysis is a highly accurate method that permits results from multiple well-designed research studies to be quantitatively compared. Meta-analysis can be performed in many settings, such as the evaluation of treatment or of a diagnostic test or prognostic factor. Meta-analyses of randomized controlled treatment trials are well known, but there is a paucity of papers describing the ways to perform a meta-analysis of a diagnostic test. The aim of this paper is to improve neurosurgeons' familiarity with the meta-analysis of diagnostic test accuracy by describing and detailing each stage leading to publication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Facial palsy is an unusual pathology that requires standard investigations and management. A clinical overview of the current attitudes is suggested to the general practitioners in order to help them in initiating the adequate investigations and treatment before referring the patient to a specialist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In high hyperdiploid acute lymphoblastic leukemia (ALL), the concurrence of specific trisomies confers a more favorable outcome than hyperdiploidy alone. Interphase fluorescence in situ hybridization (FISH) complements conventional cytogenetics (CC) through its sensitivity and ability to detect chromosome aberrations in nondividing cells. To overcome the limits of manual I-FISH, we developed an automated four-color I-FISH approach and assessed its ability to detect concurrent aneuploidies in ALL. I-FISH was performed using centromeric probes for chromosomes 4, 6, 10, and 17. Parameters established for nucleus selection and signal detection were evaluated. Cutoff values were determined. Combinations of aneuploidies were considered relevant when each aneuploidy was individually significant. Results obtained in 10 patient samples were compared with those obtained with CC. Various combinations of aneuploidies were identified. All clones detected by CC were observed also by I-FISH, and I-FISH revealed numerous additional abnormal clones in all patients, ranging from < or =1% to 31.6% of cells analyzed. We conclude that four-color automated I-FISH permits the identification of concurrent aneuploidies of potential prognostic significance. Large numbers of cells can be analyzed rapidly. The large number of nuclei scored revealed a high level of chromosome variability both at diagnosis and relapse, the prognostic significance of which is of considerable clinical interest and merits further evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dilatation of the ascending aorta (AAD) is a prevalent aortopathy that occurs frequently associated with bicuspid aortic valve (BAV), the most common human congenital cardiac malformation. The molecular mechanisms leading to AAD associated with BAV are still poorly understood. The search for differentially expressed genes in diseased tissue by quantitative real-time PCR (qPCR) is an invaluable tool to fill this gap. However, studies dedicated to identify reference genes necessary for normalization of mRNA expression in aortic tissue are scarce. In this report, we evaluate the qPCR expression of six candidate reference genes in tissue from the ascending aorta of 52 patients with a variety of clinical and demographic characteristics, normal and dilated aortas, and different morphologies of the aortic valve (normal aorta and normal valve n = 30; dilated aorta and normal valve n = 10; normal aorta and BAV n = 4; dilated aorta and BAV n = 8). The expression stability of the candidate reference genes was determined with three statistical algorithms, GeNorm, NormFinder and Bestkeeper. The expression analyses showed that the most stable genes for the three algorithms employed were CDKN1β, POLR2A and CASC3, independently of the structure of the aorta and the valve morphology. In conclusion, we propose the use of these three genes as reference genes for mRNA expression analysis in human ascending aorta. However, we suggest searching for specific reference genes when conducting qPCR experiments with new cohort of samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aetiology of autoimmune hepatitis (AIH) is uncertain but the disease can be triggered in susceptible patients by external factors such as viruses or drugs. AIH usually develops in individuals with a genetic background mainly consisting of some risk alleles of the major histocompatibility complex (HLA). Many drugs have been linked to AIH phenotypes, which sometimes persist after drug discontinuation, suggesting that they awaken latent autoimmunity. At least three clinical scenarios have been proposed that refers to drug- induced autoimmune liver disease (DIAILD): AIH with drug-induced liver injury (DILI); drug induced-AIH (DI-AIH); and immune mediated DILI (IM-DILI). In addition, there are instances showing mixed features of DI-AIH and IM-DILI, as well as DILI cases with positive autoantibodies. Histologically distinguishing DILI from AIH remains a challenge. Even more challenging is the differentiation of AIH from DI-AIH mainly relying in histological features; however, a detailed standardised histologic evaluation of large cohorts of AIH and DI-AIH patients would probably render more subtle features that could be of help in the differential diagnosis between both entities. Growing information on the relationship of drugs and AIH is being available, being drugs like statins and biologic agents more frequently involved in cases of DIAILD. In addition, there is some evidence on the fact that patients diagnosed with DIAILD may have had a previous episode of hepatotoxicity. Further collaborative studies in DIAILD will strengthen the knowledge and understanding of this intriguing and complex disorder which might represent different phenotypes across the spectrum of disease.