730 resultados para Delivery device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the variation in prevalence of temporomandibular disorders (TMD), other side effects, and technical complications during 5 years of sleep apnea treatment with a mandibular advancement device. Materials and Methods: Forty patients diagnosed with obstructive sleep apnea received an adjustable appliance at 70% of the maximum protrusion. The protrusion was then progressively increased. TMD (diagnosed according to the Research Diagnostic Criteria for TMD), overjet, overbite, occlusal contacts, subjective side effects, and technical complications were recorded before and a mean of 14, 21, and 58 months after treatment and analyzed by the Wilcoxon test (P Less-than .05). Results: Fifteen patients still used the oral appliance at the 5-year follow-up, and no significant variation in TMD prevalence was observed. Subjective side effects were common, and a significant reduction was found in overjet, overbite, and in the number of occlusal contacts. Furthermore, the patients made a mean of 2.5 unscheduled dental visits per year and a mean of 0.8 appliance repairs/relines per year by a dental technician. The most frequent unscheduled visits were needed during the first year and were a result of acrylic breakage on the lateral telescopic attachment, poor retention, and other adjustments to improve comfort. Conclusions: Five-year oral appliance treatment does not affect TMD prevalence but is associated with permanent occlusal changes in most sleep apnea patients during the first 2 years. Patients seek several unscheduled visits, mainly because of technical complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Iowa Department of Transportation research project HR-1013 is the evaluation of a prototype continuous monitoring nuclear density unit. The Unit, the Consolidation Monitoring Device (CMD), mounts on the rear of a slip-form paver and measures the density of the concrete while still in the plastic state. The evaluation performed determined the usefulness, accuracy, precision and reproducibility of the unit. The CMD was calibrated and tested in the laboratory for one week before field evaluation. The field evaluation consisted of monitoring at least 5 miles of paving and then correlating the CMD data with two conventional density methods. The two supplemental methods were density measurement with a Troxler nuclear gauge and densities obtained from core samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To compare the cumulative live birth rates obtained after cryopreservation of either pronucleate (PN) zygotes or early-cleavage (EC) embryos. DESIGN: Prospective randomized study. SETTING: University hospital. PATIENT(S): Three hundred eighty-two patients, involved in an IVF/ICSI program from January 1993 to December 1995, who had their supernumerary embryos cryopreserved either at the PN (group I) or EC (group II) stage. For 89 patients, cryopreservation of EC embryos was canceled because of poor embryo development (group III). Frozen-thawed embryo transfers performed up to December 1998 were considered. MAIN OUTCOME MEASURE(S): Age, oocytes, zygotes, cryopreserved and transferred embryos, damage after thawing, cumulative embryo scores, implantation, and cumulative live birth rates. RESULT(S): The clinical pregnancy and live birth rates were similar in all groups after fresh embryo transfers. Significantly higher implantation (10.5% vs. 5.9%) and pregnancy rates (19.5% vs. 10.9%; P< or = .02 per transfer after cryopreserved embryo transfers were obtained in group I versus group II, leading to higher cumulative pregnancy (55.5% vs. 38.6%; P < or = .002 and live birth rates (46.9% vs. 27.7%; P< or = .0001.Conclusion(s): The transfer of a maximum of three unselected embryos and freezing of all supernumerary PN zygotes can be safely done with significantly higher cumulative pregnancy chances than cryopreserving at a later EC stage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We have developed a nonviral gene therapy method based on the electrotransfer of plasmid in the ciliary muscle. These easily accessible smooth muscle cells could be turned into a biofactory for any therapeutic proteins to be secreted in a sustained manner in the ocular media. METHODS: Electrical conditions, design of electrodes, plasmid formulation, method and number of injections were optimized in vivo in the rat by localizing β-galactosidase expression and quantifying reporter (luciferase) and therapeutic (anti-tumor necrosis factor) proteins secretion in the ocular media. Anatomical measurements were performed via human magnetic resonance imaging to design a human eye-sized prototype that was tested in the rabbit. RESULTS: In the rat, transscleral injection of 30 µg of plasmid diluted in half saline (77 mM NaCl) followed by application of eight square-wave electrical pulses (15 V, 10 ms, 5.3 Hz) using two platinum/iridium electrodes, an internal wire and an external sheet, delivered plasmid efficiently to the ciliary muscle fibers. Gene transfer resulted in a long-lasting (at least 5 months) and plasmid dose-/injection number- dependent secretion of different molecular weight proteins mainly in the vitreous, without any systemic exposure. Because ciliary muscle anatomical measurements remained constant among ages in adult humans, an integrated device comprising needle-electrodes was designed and manufactured. Its usefulness was validated in the rabbit. CONCLUSIONS: Plasmid electrotransfer to the ciliary muscle with a suitable medical device represents a promising local and sustained protein delivery system for treating posterior segment diseases, avoiding repeated intraocular injections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The major source of hemolysis during cardiopulmonary bypass remains the cardiotomy suction and is primarily due to the interaction between air and blood. The Smart suction system involves an automatically controlled aspiration designed to avoid the mixture of blood with air. This study was set-up to compare this recently designed suction system to a Cell Saver system in order to investigate their effects on blood elements during prolonged intrathoracic aspiration. METHODS: In a calf model (n=10; mean weight, 69.3+/-4.5 kg), a standardized hole was created in the right atrium allowing a blood loss of 100 ml/min, with a suction cannula placed into the chest cavity into a fixed position during 6 h. The blood was continuously aspirated either with the Smart suction system (five animals) or the Cell Saver system (five animals). Blood samples were taken hourly for blood cell counts and biochemistry. RESULTS: In the Smart suction group, red cell count, plasma protein and free hemoglobin levels remained stable, while platelet count exhibited a significant drop from the fifth hour onwards (prebypass: 683+/-201*10(9)/l, 5 h: 280+/-142*10(9)/l, P=0.046). In the Cell Saver group, there was a significant drop of the red cell count from the third hour onwards (prebypass: 8.6+/-0.9*10(12)/l, 6 h: 6.3+/-0.4*10(12)/l, P=0.02), of the platelet count from the first hour onwards (prebypass: 630+/-97*10(9)/l, 1 h: 224+/-75*10(9)/l, P<0.01), and of the plasma protein level from the first hour onwards (prebypass: 61.7+/-0.6 g/l, 1 h: 29.3+/-9.1 g/l, P<0.01). CONCLUSIONS: In this experimental set-up, the Smart suction system avoids damage to red cells and affects platelet count less than the Cell Saver system which induces important blood cell destruction, as any suction device mixing air and blood, as well as severe hypoproteinemia with its metabolic, clotting and hemodynamic consequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to evaluate the efficacy of sustained release of vancomycin and teicoplanin from a resorbable gelatin glycerol sponge, in order to establish a new delivery system for local anti-infective therapy. MATERIALS AND METHODS: 60 plasticized glycerol gelatin sponges containing either 10 or 20% gelatin (w/v) were incubated in vancomycin or teicoplanin solution at 20 degrees C for either 1 or 24 h. In vitro release properties of the sponges were investigated over a period of 1 week by determining the levels of vancomycin and teicoplanin eluted in plasma using fluorescent polarization immunoassay. The rate constant and the half-life for the antibiotic release of each group were calculated by linear regression assuming first order kinetics. RESULTS: Presoaking for 24 h was associated with a significant increase in the total antibiotic release in all groups opposed to 1 h of incubation, except for the 10% sponges presoaked in teicoplanin. Doubling the gelatin content of the sponges from 10 to 20% significantly increased the total release of antibiotic load only in teicoplanin-containing sponges after 24 h incubation. In all corresponding groups investigated, release of vancomycin was more prolonged compared to teicoplanin, which allowed a gradual release beyond 5 days. The half-life (h +/- SEM) of both types of vancomycin-containing sponges was significantly prolonged by 24 h incubation in comparison to 1 h incubation (29.1 +/- 5.9 vs 5.9 +/- 1.0; p < 0.001, 30.0 +/- 2.1 vs 11.1 +/- 1.9; p < 0.001). However, neither doubling the gelatin content of the sponges nor a prolonged incubation was associated with a significantly prolonged delivery of teicoplanin. CONCLUSION: This study demonstrated a better diffusion-controlled release of vancomycin-impregnated glycerol gelatin sponges compared to those pretreated with teicoplanin. The plasticized glycerol gelatin sponge may be a promising carrier for the application of vancomycin to infected wounds for local anti-infective therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the antimitotic and toxic effects of 5-chlorouracil (5-CU) and 5-fluorouracil (5-FU) and study their potential to delay filtering bleb closure in the rabbit eye when released by poly(ortho esters) (POE). METHODS: Rabbit Tenon fibroblasts and human conjunctival cells were incubated with various 5-CU and 5-FU concentrations. Antiproliferative effects and toxicity were evaluated at 24 and 72 hours by monotetrazolium, neutral red, and Hoechst tests and cell counting. Mechanisms of cell death were evaluated using TUNEL assay, annexin V binding, immunohistochemistry for anti-apoptosis-inducing factor (AIF) and LEI/L-DNase II. Trabeculectomy was performed in pigmented rabbits. Two hundred microliters of POE loaded with 1% wt/wt 5-FU or 5-CU was injected into the subconjunctival space after surgery. Intraocular pressure (IOP) and bleb persistence were monitored for 150 days. RESULTS: In vitro, 5-FU showed a higher antiproliferative effect and a more toxic effect than 5-CU. 5-FU induced cell necrosis, whereas 5-CU induced mostly apoptosis. The apoptosis induced by 5-CU was driven through a non-caspase-dependent pathway involving AIF and LEI/L-DNase II. In vivo, at 34 days after surgery, the mean IOP in the POE/5-CU-treated group was 83% of the baseline level and only 40% in the POE/5-FU-treated group. At 100 days after surgery, IOP was still decreased in the POE/5-CU group when compared with the controls and still inferior to the preoperative value. The mean long-term IOP, with all time points considered, was significantly (P < 0.0001) decreased in the POE/5-CU-treated group (6.0 +/- 2.4 mm Hg) when compared with both control groups, the trabeculectomy alone group (7.6 +/- 2.9 mm Hg), and the POE alone group (7.5 +/- 2.6 mm Hg). Histologic analysis showed evidence of functioning blebs in the POE-5-CU-treated eyes along with a preserved structure of the conjunctiva epithelium. CONCLUSIONS: The slow release of 5-CU from POE has a longstanding effect on the decrease of IOP after glaucoma-filtering surgery in the rabbit eye. Thus, the slow release of POE/5-CU may be beneficial for the prevention of bleb closure in patients who undergo complicated trabeculectomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous drug delivery systems (DDSs) can be used as intraocular tools to provide a sustained and calibrated release for a specific drug. Great progress has been made on the design, biocompatibility, bioavailability, and efficacy of DDSs. Although several of them are undergoing clinical trials, a few are already on the market and could be of a routine use in clinical practice. Moreover, miniaturization of the implants makes them less and less traumatic for the eye tissues and some DDSs are now able to target certain cells or tissues specifically. An overview of ocular implants with therapeutic application potentials is provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Gastric banding still represents one of the most widely used bariatric procedures. It provides acceptable weight loss in many patients, but has frequent long-term complications. Because different types of bands may lead to different results, we designed a randomized study to compare the Lapband® with the SAGB®. We hereby report on the long-term results. METHODS: Between December 1998 and June 2002, 180 morbidly obese patients were randomized between Lapband® or SAGB®. Weight loss, long-term morbidity, and need for reoperation were evaluated. RESULTS: Long-term weight loss did not differ between the two bands. Patients who maintained their band had an acceptable long-term weight loss of between 50 and 60 % EBMIL. In both groups, about half the patients developed long-term complications, with about 50 % requiring major redo surgery. There was no difference in the overall rates of long-term complications or failures between the two groups, but patients who had a Lapband® were significantly more prone to develop band slippage/pouch dilatation (13.3 versus 0 %, p < 0,001). CONCLUSIONS: Although in the absence of complication, gastric banding leads to acceptable weight loss; the long-term complication and major reoperation rates are very high independently from the type of band used or on the operative technique. Gastric banding leads to relatively poor overall long-term results and therefore should not be considered the procedure of choice for the treatment of morbid obesity. Patients should be informed of the limited overall weight loss and the very high complication rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spherical carbon coated iron particles of nanometric diameter in the 510 nm range have been produced by arc discharge at near-atmospheric pressure conditions (using 58·10 4 Pa of He). The particles exhibit a crystalline dense iron core with an average diameter 7.4 ± 2.0 nm surrounded by a sealed carbon shell, shown by transmission electron microscopy (TEM), selected-area diffrac- tion (SAED), energy-dispersive X-ray analysis (STEM-EDX) and electron energy loss spectroscopy (EELS). The SAED, EDX and EELS results indicate a lack of traces of core oxidized phases showing an efficient protection role of the carbon shell. The magnetic properties of the nanoparticles have been investigated in the 5300 K temperature range using a superconducting quantum interference device (SQUID). The results reveal a superparamagnetic behaviour with an average monodomain diameter of 7.6 nm of the nanoparticles. The zero field cooled and field cooled (ZFC-FC)magnetization curves show a blocking temperature (TB)at room temperature very suitable for biomedical applications (drug delivery, magnetic resonance imaging MRI, hyperthermia).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three pyrenyl-arene ruthenium complexes (M(1)-M(3)) of the general formula [Ru(η(6)-arene-pyrenyl)Cl(2)(pta)] (pta = 1,3,5-triaza-7-phosphaadamantane) have been synthesised and characterised. Prior to the coordination to ruthenium, pyrene was connected to the arene ligand via an alkane chain containing different functional groups: ester (L(1)), ether (L(2)) and amide (L(3)), respectively. Furthermore, the pyrenyl moieties of the M(n) complexes were encapsulated within the hydrophobic cavity of the water soluble metalla-cage, [Ru(6)(η(6)-p-cymene)(6)(tpt)(2)(donq)(3)](6+) (tpt = 2,4,6-tri-(pyridin-4-yl)-1,3,5-triazine; donq = 5,8-dioxydo-1,4-naphthoquinonato), while the arene ruthenium end was pointing out of the cage, thus giving rise to the corresponding host-guest systems [M(n)⊂Ru(6)(η(6)-p-cymene)(6)(tpt)(2)(donq)(3)](6+) ([M(n)⊂cage](6+)). The antitumor activity of the pyrenyl-arene ruthenium complexes (M(n)) and the corresponding host-guest systems [M(n)⊂cage][CF(3)SO(3)](6) were evaluated in vitro in different types of human cancer cell lines (A549, A2780, A2780cisR, Me300 and HeLa). Complex M(2), which contains an ether group within the alkane chain, demonstrated at least a 10 times higher cytotoxicity than the reference compound [Ru(η(6)-p-cymene)Cl(2)(pta)] (RAPTA-C). All host-guest systems [M(n)⊂cage](6+) showed good anticancer activity with IC(50) values ranging from 2 to 8 μM after 72 h exposure. The fluorescence of the pyrenyl moiety allowed the monitoring of the cellular uptake and revealed an increase of uptake by a factor two of the M(2) complex when encapsulated in the metalla-cage [Ru(6)(η(6)-p-cymene)(6)(tpt)(2)(donq)(3)](6+).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photodynamic therapy (PDT) has been used as an adjunct to cytoreductive surgery in patients with malignant pleura mesothelioma (MPM). However, it was associated with substantial side effects and found to be only of modest clinical benefit. In contrast, Visudyne®-mediated low-dose PDT has been shown to selectively increase the concentration of macromolecular cytostatic compounds in various tumors grown subpleurally on rodent lungs. Consequently, it was thought that PDT-assisted enhanced tumor penetration for cytostatic agents might be better suited to achieve additional tumor control after cytoreductive surgery for mesothelioma. This effect seems to be mainly related to PDT-mediated modulations of tumor vessels which improve the distribution of circulating, systemically administered chemotherapeutic macromolecular agents. However, the mechanisms involved and the optimization of this effect for therapeutic implications remain to be solved. By using the dorsal skin fold chamber method we demonstrated that both angiogenesis and microcirculation of human mesothelioma xenografts can be continuously assessed in vivo by intravital microscopy. We described a new, simple, reproducible and reliable scoring system for the assessment of tumor angiogenesis and microcirculation in this model, thereby allowing the quantitative description of the neo-vascular network development while avoiding a complicated technical setup. This method can serve as a useful tool for the assessment of novel vessel-targeted therapies against MPM. We then applied this newly established model so as to elucidate the underlying mechanisms of PDT-induced extravasation of macromolecular compounds across the endothelial barrier in tumors and surrounding normal tissue. We found that low-dose PDT selectively enhanced the uptake of macromolecular compounds in human mesothelioma xenografts compared to surrounding normal tissue. Interestingly, this increase of effective permeability of tumor vasculature was not related to the inflammatory stimuli generated by PDT such as the mobilization of leucocytes and their adhesion and penetration of the injured vessel wall. We then used the model for optimizing the drug-light conditions of low- dose PDT in order to obtain maximal leakage of the macromolecular compounds in the tumor with minimal uptake in normal surrounding tissue and we were able to identify such a therapeutic window. With these optimized PDT treatment conditions, we assessed the therapeutic effect of this new treatment concept in vivo by measuring tumor growth rates on subcutaneously grown mesothelioma xenografts in nude mice after low-dose PDT of the tumors following systemically administered liposomal (macromolecular) cisplatin, a cytostatic compound commonly used in clinical practice. We were able to demonstrate that low-dose PDT with optimized drug-light conditions combined with systemic chemotherapy indeed resulted in a reduction in tumor growth compared to chemotherapy or PDT alone. In conclusion, our work demonstrates that low-dose PDT may selectively enhance the uptake of macromolecular cytostatic drugs in superficially growing tumors such as mesotheliomas and opens new perspectives for the treatment of these diseases. - Les effets cytotoxiques de la thérapie photodynamique (PDT) sur le mésothéliome pleural malin (MPM) n'ont pas apporté de bénéfice clinique significatif. Toutefois, une application innovante non cytotoxique de la PDT serait la bienvenue en supplément des chimiothérapies pour améliorer le contrôle local de la tumeur. Le prétraitement des néovaisseaux tumoraux par une PDT à bas régime, qui améliorerait la distribution d'une chimiothérapie administrée par voie systémique de façon concomitante, a attiré une attention particulière pour de futures applications cliniques. Toutefois, les mécanismes impliqués dans cet événement et les implications thérapeutiques de ces changements physiopathologiques restent non résolus. Dans cette thèse, nous avons observé en premier que l'angiogenèse et la microcirculation dans les xénogreffes de mésothéliomes humains peuvent être observées et analysées in vivo par microscopie intravitale. Le nouveau système de score appliqué pour l'évaluation de l'angiogenèse et de la microcirculation tumorale dans cette étude est une méthode simple, reproductible et fiable servant à décrire de manière quantitative le réseau néo-vasculaire en développement, tout en évitant d'utiliser une installation technique compliquée. Ce modèle sert de nouvel outil pour l'évaluation des thérapies anti-vasculaires dirigées contre le MPM. Le modèle animal nouvellement établi a alors été utilisé pour élucider les mécanismes sous-jacents de Γ extravasation d'agents macromoléculaires induite par PDT dans les vaisseaux tumoraux et normaux. Nous avons trouvé que la PDT à fable dose améliore la distribution ciblée de drogues macromoléculaires dans des greffes de mésothéliome humain, de manière sélective pour la tumeur. La perméabilité vasculaire tumorale n'est pas influencée par les stimuli inflammatoires générés par la PDT, ce qui joue un rôle important dans la sélectivité de notre photodynamic drug delivery. Ensuite, nous avons recherché la fenêtre thérapeutique optimale de la PDT pour obtenir une accumulation sélective du colorant macromoléculaire dans le tissu tumoral ainsi qu'une efficacité de la PDT combinée avec une chimiothérapie macromoléculaire sur la croissance tumorale. Nous avons démontré que la PDT à faible dose combinée avec une administration systémique de cisplatine liposomale mène à un ralentissement de la croissance tumorale dans notre modèle de mésothéliome malin humain. En conclusion, l'utilisation de la PDT comme prétraitement pour améliorer sélectivement la distribution d'agents thérapeutiques dans des tumeurs poussant superficiellement est prometteuse. Cette observation fourni une preuve du concept remarquable et garanti la suite des investigations, éventuellement ayant pour but de développer de nouveaux concepts de thérapie pour les patients atteints de mésothéliome. Une PDT intra cavitaire à faible dose après pleuro- pneumonectomie pourrait améliorer la pénétration des agents cytostatiques administrés de façon concomitante par voie systémique dans les îlots tumoraux résiduels, et ainsi améliorer le contrôle local.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retinal diseases are nowadays the most common causes of vision threatening in developed countries. Therapeutic advances in this field are hindered by the difficulty to deliver drugs to the posterior segment of the eye. Due to anatomical barriers, the ocular biodisponibility of systemically administered drugs remains poor, and topical instillation is not adequate to achieve therapeutic concentrations of drugs in the back of the eye. Ocular drug delivery has thus become one of the main challenges of modern ophthalmology. A multidisciplinary research is being conducted worldwide including pharmacology, biomaterials, ophthalmology, pharmaceutics, and biology. New promising fields have been developed such as implantable or injectable slow release intravitreal devices and degradable polymers, dispersed polymeric systems for intraocular drug delivery, and transscleral delivery devices such as iontophoresis, osmotic pumps or intra-scleraly implantable materials. The first clinical applications emerging from this research are now taking place, opening new avenues for the treatment of retinal diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of new drug delivery systems to target the anterior segment of the eye may offer many advantages: to increase the biodisponibility of the drug, to allow the penetration of drug that cannot be formulated as solutions, to obtain constant and sustained drug release, to achieve higher local concentrations without systemic effects, to target more specifically one tissue or cell type, to reduce the frequency of instillation and therefore increase the observance and comfort of the patient while reducing side effects of frequent instillation. Several approaches are developed, aiming to increase the corneal contact time by modified formulation or reservoir systems, or by increasing the tissue permeability using iontophoresis. To date, no ocular drug delivery system is ideal for all purposes. To maximize treatment efficacy, careful evaluation of the specific pathological condition, the targeted Intraocular tissue and the location of the most severe pathology must be made before selecting the method of delivery most suitable for each individual patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accurate diagnosis of orthopedic device-associated infections can be challenging. Culture of tissue biopsy specimens is often considered the gold standard; however, there is currently no consensus on the ideal incubation time for specimens. The aim of our study was to assess the yield of a 14-day incubation protocol for tissue biopsy specimens from revision surgery (joint replacements and internal fixation devices) in a general orthopedic and trauma surgery setting. Medical records were reviewed retrospectively in order to identify cases of infection according to predefined diagnostic criteria. From August 2009 to March 2012, 499 tissue biopsy specimens were sampled from 117 cases. In 70 cases (59.8%), at least one sample showed microbiological growth. Among them, 58 cases (82.9%) were considered infections and 12 cases (17.1%) were classified as contaminations. The median time to positivity in the cases of infection was 1 day (range, 1 to 10 days), compared to 6 days (range, 1 to 11 days) in the cases of contamination (P < 0.001). Fifty-six (96.6%) of the infection cases were diagnosed within 7 days of incubation. In conclusion, the results of our study show that the incubation of tissue biopsy specimens beyond 7 days is not productive in a general orthopedic and trauma surgery setting. Prolonged 14-day incubation might be of interest in particular situations, however, in which the prevalence of slow-growing microorganisms and anaerobes is higher.