964 resultados para Decision Quality
Resumo:
Background: A previous study associated CD34(+) levels with NYHA functional class in heart failure patients. The aim of this study was to correlate CD34(+) levels to exercise capacity, functional class, quality of life and norepinephrine in heart failure patients. Methods: Twenty three sedentary patients (52 +/- 7 years, 78% male) answered the Minnesota Living with Heart Failure Questionnaire and rested for 20 minutes before an investigator collect a blood sample. After this, patients performed a cardiopulmonary exercise test to determine the heart rate at anaerobic and ventilatory threshold and oxygen consumption at peak effort, at anaerobic and ventilatory threshold. One other blood sample was collected during the peak effort to investigate the norepinephrine and CD34(+) levels. Results: Rest percentage of CD34(+) did not show correlation with: left ventricle ejection fraction (r = 0.03, p = 0.888), peakVO(2) (r = 0.32, p = 0.13), VO(2) at anaerobic threshold (VO(2)AT) (r = 0.03, p = 0.86), VO(2) at ventilatory threshold (VO(2)VT) (r = 0.36, p = 0.08), NYHA functional class (r = -0.2, p = 0.35), quality of life (Minnesota) (r = -0.17, p = 0.42). CD34(+) did not show correlation, either, with: peak VO(2) (r = 0.38, p = 0.06), VO(2)AT (r = 0.09, p = 0.65), VO(2)VT (r = 0.43, p = 0.4), NYHA functional class (r = -0.13, p = 0.54), quality of life (r = 0.00, p = 0.99). Conclusions: CD34(+) levels did not correlate with exercise capacity, functional class, quality of life and norepinephrine. Percentage of CD34(+) levels did not increase during the cardiopulmonary exercise test in heart failure patients. (Cardiol J 2009; 16, 5: 426-431)
Resumo:
Background:The Nasal Obstruction Symptom Evaluation (NOSE) instrument is a disease-specific questionnaire for assessing the outcome of an intervention in nasal obstruction in trials. This instrument is only available in the English language and cross-culturally valid questionnaires are very important for all research, including nasal obstruction. The aim of the current study was to reproduce the cross-cultural adaptation process for the NOSE questionnaire in the Portuguese language (NOSE-p). Methodology: Cross-cultural adaptation and validation of the instrument were divided into two stages. Stage I involved four bilingual professionals, an expert committee and the author of the original instrument. In Stage 2, the NOSE-p was tested on 33 patients undergoing septoplasty for internal consistency, test-retest reliability, construct validity. discriminant validity, criterion validity, and response sensitivity. Results: The cross-cultural adaptation process was completed and the NOSE-p was demonstrated to be a valid instrument with satisfactory construct validity. It showed an adequate internal consistency reliability and adequate test-retest reliability. It could discriminate between patients with and without nasal obstruction and it has a high response sensitivity to change. Conclusions: The cross-cultural adaptation and validation process demonstrated to be valid and the NOSE-p proved to be applicable in Brazil.
Resumo:
Objective. Refractory, disabling pain associated with knee osteoarthritis (OA) is usually treated with total knee replacement. However, pain in these patients might be associated with central nervous sensitization rather than peripheral inflammation and injury. We evaluated the presence of hyperalgesia in patients scheduled for a total knee replacement due to knee osteoarthritis with refractory pain, and we assessed the impact of pressure pain threshold measurements (PPT) on pain, disability, and quality of life of these patients. Methods. Sixty-two female patients were compared with 22 age-matched healthy controls without reported pain for the last year. PPT was measured at the lower extremities subcutaneous dermatomes, over the vastus medialis, adductor longus, rectus femoris, vastus lateralis, tibialis anterior, peroneus longus, iliacus, quadratus lumborum and popliteus muscles and at the supraspinous ligaments from L1-L5, over the L5-S1 and S1-S2 sacral areas and at the pes anserinus bursae and patellar tendon. Results. Patients with knee OA had significantly lower PPT over all evaluated structures versus healthy control subjects (P < 0.001). Lower PPT values were correlated with higher pain intensity, higher disability scores, and with poorer quality of life, except for the role-emotional and general health status. Combined PPT values over the patellar tendon, at the S2 subcutaneous dermatome and at the adductor longus muscle were the best predictors for visual analog scale and Western Ontario and McMaster Universities Osteoarthritis Index pain scores. Conclusion. Patients with pain due to osteoarthritis who were scheduled for total knee replacement showed hyperalgesia of nervous system origin that negatively impacted pain, knee functional capacity, and most aspects of quality of life.
Resumo:
Crack cocaine-dependent individuals (CCDI) present abnormalities in both social adjustment and decision making, but few studies have examined this association. This study investigated cognitive and social performance of 30 subjects (CCDI x controls); CCDI were abstinent for 2 weeks. We used the Social Adjustment Scale (SAS), Wisconsin Card Sorting Test (WCST), and Iowa Gambling Task (IGT). Disadvantageous choices on the IGT were associated with higher levels of social dysfunction in CCDI, suggesting the ecological validity of the IGT. Social dysfunction and decision making may be linked to the same underlying prefrontal dysfunction, but the nature of this association should be further investigated. (Am J Addict 2010;00: 1-9).
Resumo:
Background: The cerebrospinal fluid (CSF) biomarkers amyloid beta (A beta)-42, total-tau (T-tau), and phosphorylated-tau (P-tau) demonstrate good diagnostic accuracy for Alzheimer`s disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer`s Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch-to-batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program. Methods: The program is open for laboratories using commercially available kits for A beta, T-tau, or P-tau. CSF samples (aliquots of pooled CSF) are sent for analysis several times a year from the Clinical Neurochemistry Laboratory at the Molndal campus of the University of Gothenburg, Sweden. Each round consists of three quality control samples. Results: Forty laboratories participated. Twenty-six used INNOTEST enzyme-linked immunosorbent assay kits, 14 used Luminex xMAP with the INNO-BIA AlzBio3 kit (both measure A beta-(1-42), P-tau(181P), and T-tau), and 5 used Mesa Scale Discovery with the A beta triplex (A beta N-42, A beta N-40, and A beta N-38) or T-tau kits. The total coefficients of variation between the laboratories were 13% to 36%. Five laboratories analyzed the samples six times on different occasions. Within-laboratory precisions differed considerably between biomarkers within individual laboratories. Conclusions: Measurements of CSF AD biomarkers show large between-laboratory variability, likely caused by factors related to analytical procedures and the analytical kits. Standardization of laboratory procedures and efforts by kit vendors to increase kit performance might lower variability, and will likely increase the usefulness of CSF AD biomarkers. (C) 2011 The Alzheimer`s Association. All rights reserved.
Resumo:
Toxoplasma gondii causes severe disease both to man and livestock and its detection in meat after slaughtering requires PCR or biological tests. Meat packages contain retained exudate that could be used for serology due to its blood content. Similar studies reported false negative assays in those tests. We standardized an anti-T. gondii IgG ELISA in muscle juices from experimentally infected rabbits, with blood content determination by cyanhemoglobin spectrophotometry. IgG titers and immunoblotting profiles were similar in blood, serum or meat juice, after blood content correction. These assays were adequate regardless of the storage time up to 120 days or freeze-thaw cycles, without false negative results. We also found 1.35% (1/74) positive sample in commercial Brazilian rabbit meat cuts, by this assay. The blood content determination shows ELISA of meat juice may be useful for quality control for toxoplasmosis monitoring. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Wastewater control at storage terminals of liquid chemical products in bulk is very difficult because of the variety of products handled in the facilities generating effluents of variable composition. The main objective of this work was to verify if the Vibrio fischeri acute toxicity test could be routinely included in the wastewater management of those facilities along with physical and chemical analysis in order to evaluate and improve the quality of the generated effluents. The study was performed in two phases before and after the implementation of better operational practices/treatment technologies. Chemical oxygen demand (COD) and toxicity of treated effluents did not correlate showing that effluents with low COD contain toxic substances and non-biodegradable organic matter, which may be not degraded when discharged into the aquatic environment. Segregation of influents or pre-treatment based on toxicity results and biodegradability index were implemented in the facilities generating significant improvements in the quality of final effluents with reduction of Biochemical oxygen demand (BOD) and toxicity. The integration of physical and chemical analysis with the V.fischeri toxicity test turned out to be an excellent tool for wastewater management in chemical terminals allowing rapid decision making for pollution control and prevention measures. Reuse of rain water was also proposed and when implemented by the facilities resulted in economical and environmental benefits. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Dizziness is frequent in elderly people. Aims: To evaluate the Quality of Life (QoL) in elderly subjects with dizziness, relate it with gender and age. Material and Method: A prospective study comprising 120 elderly patients with dizziness evaluated with Brazilian versions of the Whoqol-bref and the dizziness handicap inventory (DHI). The factor analysis (FA), the Mann Whitney and Kruskal Wallis tests, and the Spearman correlation were applied to study the results. Results: The most compromised domains were the DHI physical domain and the Whoqol-bref physical and environment domains. FA resulted in 3 factors in the DHI and 5 factors in the Whoqol-bref. There was a moderate correlation (-0.596) in the total scores of both instruments. Males had a better QoL in the ""environment perception and introspectivity"" and ""health perception"" factors of the Whoqol-bref test. Females had a better QoL in the ""functionality perception"" factor of the Whoqol-bref test. There were no significant age differences. Conclusions: Elderly patients with dizziness have a worse QoL. Elderly females with dizziness have worse QoL scores in ""environment perception and introspectivity"" and ""health perception"" and better QoL in the ""functionality perception"" factor compared to elderly males.
Resumo:
OBJECTIVE. The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS. Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <= 600 Agatston units (214 men and 77 women; mean age, 59.3 +/- 10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>= 50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS. Increasing body mass index (BMI) (odds ratio [OR] = 0.89, p < 0.001), increasing heart rate (OR = 0.90, p < 0.001), and the presence of breathing artifact (OR = 4.97, p = 0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR = 0.58, p = 0.04). At a vessel level, CAC score (10 Agatston units) (OR = 1.03, p = 0.012) and patient age (OR = 1.02, p = 0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p = 0.08). CONCLUSION. Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.