994 resultados para D-endocrine System


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The (-)-hinokinin display high activity against Trypanosoma cruzi in vitro and in vivo. (-)-Hinokinin-loaded poly(d,l-lactide-co-glycolide) microparticles were prepared and characterized in order to protect (-)-hinokinin of biological interactions and promote its sustained release for treatment of Chagas disease. The microparticles contain (-)-hinokinin were prepared by the classical method of the emulsion/solvent evaporation. The scanning electron microscopy, light-scattering analyzer were used to study the morphology and particle size, respectively. The encapsulation efficiency was determined, drug release studies were kinetically evaluated, and the trypanocidal effect was evaluated in vivo. (-)-Hinokinin-loaded microparticles obtained showed a mean diameter of 0.862 A mu m with smooth surface and spherical shape. The encapsulation efficiency was 72.46 A +/- 2.92% and developed system maintained drug release with Higuchi kinetics. The preparation method showed to be suitable, since the morphological characteristics, encapsulation efficiency, and in vitro release profile were satisfactory. In vivo assays showed significant reduction of mice parasitaemia after administration of (-)-hinokinin-loaded microparticles. Thus, the developed microparticles seem to be a promising system for sustained release of (-)-hinokinin for treatment of Chagas disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on the experimental observation of the generalized synchronization of chaos in a real physical system. We show that under a nonlinear resonant interaction, the chaotic dynamics of a single mode laser can become functionally related to that of a chaotic driving signal and furthermore as the coupling strength is further increased, the chaotic dynamics of the laser approaches that of the driving signal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

I investigated the genetic relationship between male and female components of the mate recognition system and how this relationship influenced the subsequent evolution of the two traits, in a series of replicate populations of interspecific hybrids. Thirty populations of hybrids between Drosophila serrata and Drosophila birchii were established and maintained for 24 generations. At the fifth generation after hybridization, the mating success of hybrid individuals with the D. serrata parent was determined. The genetic correlation between male and female components of the male recognition system, as a consequence of pleiotropy or tight physical linkage, was found to be significant but low (r = 0.388). This result suggested that pleiotropy may play only a minor role in the evolution of mate recognition in this system. At the twenty-fourth generation after hybridization, the mating success of the hybrids was again determined. The evolution of male and female components was investigated by analyzing the direction of evolution of each hybrid line with respect to its initial position in relation to the genetic regression. Male and female components appeared to converge on a single equilibrium point, rather than evolving along trajectories with slope equal to the genetic regression, toward a line of equilibria.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The activities of conantokin-G (con-G), conantokin-T (con-T), and several novel analogues have been studied using polyamine enhancement of [H-3]MK-801 binding to human glutamate-N-methyl-D-aspartate (NMDA) receptors, and their structures have been examined using CD and H-1 NMR spectroscopy. The potencies of con-G[A7], con-G, and con-T as noncompetitive inhibitors of spermine-enhanced [H-3]MK-801 binding to NMDA receptor obtained from human brain tissue are similar to those obtained using rat brain tissue. The secondary structure and activity of con-G are found to be highly sensitive to amino acid substitution and modification. NMR chemical shift data indicate that con-G, con-G[D8,D17], and con-G[A7] have similar conformations in the presence of Ca2+. This consists of a helix for residues 2-16, which is kinked in the vicinity of Gla10. This is confirmed by 3D structure calculations on con-G[A7]. Restraining this helix in a linear form (i.e., con-G[A7,E10-K13]) results in a minor reduction in potency. Incorporation of a 7-10 salt-bridge replacement (con-G[K7-E10]) prevents helix formation in aqueous solution and produces a peptide with low potency. Peptides with the Leu5-Tyr5 substitution also have low potencies (con-G[Y5,A7] and con-G[Y5,K7]) indicating that Leu5 in con-G is important for full antagonist behavior. We have also shown that the Gla-Ala7 substitution increases potency, whereas the Gla-Lys7 substitution has no effect. Con-G and con-G[K7] both exhibit selectivity between NMDA subtypes from mid-frontal and superior temporal gyri, but not between sensorimotor and mid-frontal gyri. Asn8 and/or Asn17 appear to be important for the ability of con-G to function as an inhibitor of polyamine-stimulated [3H]MK-801 binding, but not in maintaining secondary structure. The presence of Ca2+ does not increase the potencies of con-G and con-T for NMDA receptors but does stabilize the helical structures of con-G, con-G[D8,D17], and, to a lesser extent, con-G[A7]. The NMR data support the existence of at least two independent Ca2+-chelating sites in con-G, one involving Gla7 and possibly Gla3 and the other likely to involve Gla10 and/or Gla14.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mechanically skinned skeletal muscle fibres from rat and toad were exposed to the permeabilizing agents beta-escin and saponin. The effects of these agents on the sealed transverse tubular system (t-system) and sarcoplasmic reticulum (SR) were examined by looking at changes in the magnitude of the force responses to t-system depolarization, the time course of the fluorescence of fura-2 trapped in the sealed t-system, and changes in the magnitude of caffeine-induced contractures following SR loading with Ca2+ under defined conditions. In the presence of 2 mu g ml(-1) beta-escin and saponin, the response to t-system depolarization was not completely abolished, decreasing to a plateau, and a large proportion of fura-2 remained in the sealed t-system. At 10 mu g ml(-1), both agents abolished the ability of both rat and toad preparations to respond to t-system depolarization after 3 min of exposure, but a significant amount of fura-2 remained in sealed t-tubules even after exposure to 100 mu g ml(-1) beta-escin and saponin for 10 min. beta-Escin took longer than saponin to reduce the t-system depolarizations and fura-2 content of the sealed t-system to a similar level. The ability of the SR to load Ca2+ was reduced to a lower level after treatment with beta-escin than saponin. This direct effect on the SR occurred at much lower concentrations for rat (2 mu g ml(-1) beta-escin and 10 mu g ml(-1) saponin) than toad (10 mu g ml(-1) beta-escin and 150 mu g ml(-1) saponin). The reverse order in sensitivities to beta-escin and saponin of t-system and SR membranes indicates that the mechanisms of action of beta-escin and saponin are different in the two types of membrane. In conclusion, this study shows that: (1) beta-escin has a milder action on the surface membrane than saponin; (2) beta-escin is a more potent modifier of SR function; (3) simple permeabilization of membranes is not sufficient to explain the effects of beta-escin and saponin on muscle membranes; and (4) the t-system network within muscle fibres is not a homogeneous compartment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The equal sex ratios found in many species with heterogametic sex determination may be a consequence of selection for equality or the result of the Mendelian segregation of the two sex chromosomes. A lack of genetic variation in sex ratio in species with heterogamety has been the major obstacle in distinguishing between these two hypotheses. We overcome this obstacle by generating hybrids between two species of Drosophila. The resulting hybrid lines had biased sex ratios, allowing us to observe the evolution of sex ratio in replicate populations. Sex ratio converged towards 1:1 after 16 generations of natural selection. These changes in sex ratio were not due to differences in viability between the sexes and the loci underlying the variation in sex ratio were not sex-linked. Equal sex ratios may therefore be the result of natural selection as Fisher predicted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SETTING: Hlabisa health district, South Africa. OBJECTIVE: To describe the integration of a vertical tuberculosis control programme into an emerging 'horizontal' district health system, within the context of health sector reform. DESIGN: Descriptive account of the process of integration of the programme into the health system. RESULTS: A highly 'vertical' system of delivering tuberculosis treatment (with poor programme outcomes) was converted into a (horizontal' team, integrated within the district health system, that used available resources such as village clinics and community health workers, with improved programme outcomes. CONCLUSIONS: In some settings at least, integration of tuberculosis 'programmes' into the district health system as tuberculosis 'teams' is feasible, and may produce highly cost-effective outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To demonstrate the potential of GIS (geographic information system) technology and ARIA (Accessibility/Remoteness Index for Australia) as tools for medical workforce and health service planning in Australia. Design: ARIA is an index of remoteness derived by measuring road distance between populated localities and service centres. A continuous variable of remoteness from 0 to 12 is generated for any location in Australia. We created a GIS, with data on location of general practitioner services in non-metropolitan South Australia derived from the database of HUMPS (Rural Undergraduate Medical Placement System), and estimated, for the 1170 populated localities in South Australia, the accessibility/inaccessibility of the 109 identified GP services. Main outcome measures: Distance from populated locality to GP services. Results: Distance from populated locality to GP service ranged from 0 to 677 km (mean, 58 km). In all, 513 localities (43%) had a GP service within 20 km (for the majority this meant located within the town). However, for 173 populated localities (15%), the nearest GP service was more than 80 km away. There was a strong correlation between distance to GP service and ARIA value for each locality (0.69; P<0.05). Conclusions: GP services are relatively inaccessible to many rural South Australian communities. There is potential for GIS and for ARIA to contribute to rational medical workforce and health service planning. Adding measures of health need and more detailed data on types and extent of GP services provided will allow more sophisticated planning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To describe heterogeneity of HIV prevalence among pregnant women in Hlabisa health district, South Africa and to correlate this with proximity of homestead to roads. METHODS HIV prevalence measured through anonymous surveillance among pregnant women and stratified by local village clinic. Polygons were created around each clinic, assuming women attend the clinic nearest their home. A geographical information system (GIS) calculated the mean distance from homesteads in each clinic catchment to nearest primary (1 degrees) and to nearest primary or secondary (2 degrees) road. RESULTS We found marked HIV heterogeneity by clinic catchment (range 19-31% (P < 0.001). A polygon plot demonstrated lower HIV prevalence in catchments remote from 1 degrees roads. Mean distance from homesteads to nearest 1 degrees or 2 degrees road varied by clinic catchment from 1623 to 7569 m. The mean distance from homesteads to a 1 degrees or 2 degrees road for each clinic catchment was strongly correlated with HIV prevalence (r = 0.66; P = 0.002). CONCLUSIONS The substantial HIV heterogeneity in this district is closely correlated with proximity to a 1 degrees or 2 degrees road. GIS is a powerful tool to demonstrate and to start to analyse this observation. Further research is needed to better understand this relationship both at ecological and individual levels, and to develop interventions to reduce the spread of HIV infection.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The volume of the extracellular compartment (tubular system) within intact muscle fibres from cane toad and rat was measured under various conditions using confocal microscopy. Under physiological conditions at rest, the fractional volume of the tubular system (t-sys(Vol)) was 1.38 +/- 0.09% (n = 17),1.41 +/- 0.09% (n = 12) and 0.83 +/- 0.07% (n = 12) of the total fibre volume in the twitch fibres from toad iliofibularis muscle, rat extensor digitorum longus muscle and rat soleus muscle, respectively. In toad muscle fibres, the t-sys(Vol) decreased by 30% when the tubular system was fully depolarized and decreased by 15% when membrane cholesterol was depleted from the tubular system with methyl-beta-cyclodextrin but did not change as the sarcomere length was changed from 1.93 to 3.30 mum. There was also an increase by 30% and a decrease by 25% in t-sys(Vol) when toad fibres were equilibrated in solutions that were 2.5-fold hypertonic and 50% hypotonic, respectively. When the changes in total fibre volume were taken into consideration, the t-sys(Vol) expressed as a percentage of the isotonic fibre volume did actually decrease as tonicity increased, revealing that the tubular system in intact fibres cannot be compressed below 0.9% of the isotonic fibre volume. The results can be explained in terms of forces acting at the level of the tubular wall. These observations have important physiological implications showing that the tubular system is a dynamic membrane structure capable of changing its volume in response to the membrane potential, cholesterol depletion and osmotic stress but not when the sarcomere length is changed in resting muscle.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Partitioning behavior of PAHs including NAP, FLO, PHE, and PYR was investigated. A plot of experimental K-HA against log K-OW gives a good linear relationship. A somewhat similar slope and intercept it-as obtained for the hair-air system using PCB values from the literature. In comparison to K-VA values from the literature, lower values for K-VA were obtained. This may be attributed from differences in species and degradability across biota groups. K-HLA also exhibits good linear relationships with K-OA and other physical chemical properties such as W The lipid fraction has a strong influence on bioconcentration in hair from the air and water. However, hair treatments, hair length, growth dilution, photodegradation, biodegradation, temperature, seasonal variations, wet and dry depositions could alter the degree of bioconcentration of PAHs in the hair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Confocal imaging of impermeant fluorescent dyes trapped in the tubular (t-) system of skeletal muscle fibres of rat and cane toad was used to examine changes in the morphology of the t-system upon mechanical skinning, the time course of dye loss from the sealed t-systern in mechanically skinned fibres and the influence of rapid application and removal of glycerol on the morphology of the sealed t-system. In contrast to intact fibres, which have a t-systern open to the outside, the sealed t-systern of toad mechanically skinned fibres consistently displayed local swellings (vesicles). The occurrence of vesicles in the sealed t-system of rat-skinned fibres was infrequent. Application and removal of 200-400 mM glycerol to the sealed t-system did not produce any obvious changes in its morphology. The dyes fluo-3, fura-2 and Oregon green 488 were lost from the sealed t-system of toad fibres at different rates suggesting that the mechanism of organic anion transport across the tubular wall was not by indiscriminate bulk transport. The rate of fluo-3 and fura-2 loss from the sealed t-system of rat fibres was greater in rat than in toad fibres and could be explained by differences in surface area: volume ratio of the t-system in the two fibre types. Based on the results presented here and on other results from this laboratory, an explanation is given for the formation of numerous vesicles in toad-skinned fibres and lack of vesicle formation in rat-skinned fibres. This explanation can also help with better understanding the mechanism responsible for vacuole formation in intact fibres. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We conduct a theoretical analysis to investigate the convective instability of 3-D fluid-saturated geological fault zones when they are heated uniformly from below. In particular, we have derived exact analytical solutions for the critical Rayleigh numbers of different convective flow structures. Using these critical Rayleigh numbers, three interesting convective flow structures have been identified in a geological fault zone system. It has been recognized that the critical Rayleigh numbers of the system have a minimum value only for the fault zone of infinite length, in which the corresponding convective flow structure is a 2-D slender-circle flow. However, if the length of the fault zone is finite, the convective flow in the system must be 3-D. Even if the length of the fault zone is infinite, since the minimum critical Rayleigh number for the 2-D slender-circle flow structure is so close to that for the 3-D convective flow structure, the system may have almost the same chance to pick up the 3-D convective flow structures. Also, because the convection modes are so close for the 3-D convective flow structures, the convective flow may evolve into the 3-D finger-like structures, especially for the case of the fault thickness to height ratio approaching zero. This understanding demonstrates the beautiful aspects of the present analytical solution for the convective instability of 3-D geological fault zones, because the present analytical solution is valid for any value of the ratio of the fault height to thickness. Using the present analytical solution, the conditions, under which different convective flow structures may take place, can be easily determined.