985 resultados para Courbe dose-réponse non linéaire
Resumo:
In the era of monoclonal antibodies the role of autologous stem cell transplantation (ASCT) in the management of follicular lymphoma (FL) is still debated. To evaluate the safety and efficacy of myeloablative therapy with rescue of purged or unpurged harvests in FL pts. At our institution form 1997 to 2007 28 pts with refractory/resistant FL were eligible for ASCT. Before high dose therapy they received 2-3 cycles of CHOP-like regimen (ACOD), followed by Cyclophosphamide 4g/mq to mobilize the stem cells (SC). After SC collection the pts underwent 3 cycles of subcutaneous Cladribine at a daily dose of 0,14-0,10 mg/Kg for Day 1-5 every 3-4 weeks. The conditioning regimen was based on Mitoxantrone 60mg/mq + Melphalan 180 mg/mq, followed by SC re-infusion 24-hours later and G-CSF starting 24 hours after re-infusion. In 19 pts the SC underwent purging: in 10 harvests the CD34+ were selected by immunomagnetic beads, while in the other 9 pts, only Rituximab was used as “purging in vivo” agent. The remaining 9 pts received unpurged SC. Before ASCT 11 pts were in complete response (CR), 9 in partial response (PR) and 2 in stable disease. Two pts were not eligible for ASCT because of progressive disease (PD). The remaining 25 pts were eligible for ASCT. The engraftment was at a median of 11 days for leucocytes and 14 days for platelets (>20.000/mmc), with a delay of one day in the pts, who received purged SC. Grade 3-4 mucositis was described in 8 pts. During aplasia a 48% infection rate was reported, without differences between pts with purged or unpurged SC. One patient in CR presented myelodysplastic syndrome at 18 months from ASCT. After ASCT 22 pts were in CR, 2 in PR and one patient were not valuable, because died before response assessment. Nine pts in CR showed PD at a median time of 14 months from ASCT. With a median follow up of 5 years (range 2 months -10 years), 22 pts are alive and 11 (44%) in CR. Ten pts died, 5 for progressive disease and 5 for treatment-related causes; in particular 7 of them received in-vitro purged SC. Conclusions: Our chemotherapy regimen, which included the purine analogue Cladribine in the induction phase, seems safe and feasible. The high rate of CR reported and the sustained freedom from progression up to now, makes such modality of treatment a valid option principally in relapsing FL patients. In our experience, the addition of a monoclonal antibody as part of treatment confirms its role “in vivo purging” without observing an increased incidence of infection.
Resumo:
Il presente lavoro è stato svolto presso la struttura di Fisica Medica dell'Azienda Ospedaliera IRCCS "Arcispedale S. Maria Nuova" di Reggio Emilia e consiste nello sviluppo di un sistema per l'ottimizzazione della dose in Radioterapia tramite dose-painting basato sui voxel. Il dose painting è una tecnica di pianificazione del trattamento di radioterapia che si basa sull'assegnazione o ridistribuzione della dose secondo le informazioni biologiche e metaboliche che i moderni sistemi di imaging sono in grado di fornire. La realizzazione del modulo di calcolo BioOPT è stata possibile grazie all'utilizzo dei due software open-source Plastimatch e CERR, specifici per l'elaborazione e la registrazione di immagini mediche di diversi tipi e formati e per la gestione, la modifica e il salvataggio di piani di trattamento di radioterapia creati con la maggior parte dei software commerciali ed accademici. Il sistema sviluppato è in grado di registrare le immagini relative ad un paziente, in generale ottenute da diverse tipologie di imaging e acquisite in tempi diversi ed estrarre le informazioni biologiche relative ad una certa struttura. Tali informazioni verranno poi utilizzate per calcolare le distribuzioni di dose "ottimale" che massimizzano il valore delle funzioni radiobiologiche utilizzate per guidare il processo di redistribuzione della dose a livello dei voxel (dose-painting). In questo lavoro il modulo è stato utilizzato principalmente per l'ottimizzazione della dose in pazienti affetti da Glioblastoma, un tumore cerebrale maligno tra i più diffusi e mortali. L'ottimizzatore voxel-based, infatti, è stato sviluppato per essere utilizzabile all'interno di un progetto di ricerca finanziato dal Ministero della Salute per la valutazione di un programma di terapia che include l'uso di un innovativo acceleratore lineare ad alto rateo di dose per la cura di tumori cerebrali in fase avanzata. Al fine di migliorare il trattamento radiante, inoltre, lo studio include la somministrazione della dose tramite dose-painting con lo scopo di verificarne l'efficacia. I risultati ottenuti mostrano che tramite il modulo sviluppato è possibile ottenere distribuzioni di dose eterogenee che tengono conto delle caratteristiche biologiche intratumore stimate a partire dalle immagini multimodali. Inoltre il sistema sviluppato, grazie alla sua natura 'open', è altamente personalizzabile a scopi di ricerca e consente di simulare distribuzioni di dose basate sui voxel e di confrontarle con quelle ottenute con i sistemi commerciali ad uso clinico, che non consentono questo tipo di ottimizzazioni.
Resumo:
Il presente lavoro di tesi è stato svolto presso il servizio di Fisica Sanitaria del Policlinico Sant'Orsola-Malpighi di Bologna. Lo studio si è concentrato sul confronto tra le tecniche di ricostruzione standard (Filtered Back Projection, FBP) e quelle iterative in Tomografia Computerizzata. Il lavoro è stato diviso in due parti: nella prima è stata analizzata la qualità delle immagini acquisite con una CT multislice (iCT 128, sistema Philips) utilizzando sia l'algoritmo FBP sia quello iterativo (nel nostro caso iDose4). Per valutare la qualità delle immagini sono stati analizzati i seguenti parametri: il Noise Power Spectrum (NPS), la Modulation Transfer Function (MTF) e il rapporto contrasto-rumore (CNR). Le prime due grandezze sono state studiate effettuando misure su un fantoccio fornito dalla ditta costruttrice, che simulava la parte body e la parte head, con due cilindri di 32 e 20 cm rispettivamente. Le misure confermano la riduzione del rumore ma in maniera differente per i diversi filtri di convoluzione utilizzati. Lo studio dell'MTF invece ha rivelato che l'utilizzo delle tecniche standard e iterative non cambia la risoluzione spaziale; infatti gli andamenti ottenuti sono perfettamente identici (a parte le differenze intrinseche nei filtri di convoluzione), a differenza di quanto dichiarato dalla ditta. Per l'analisi del CNR sono stati utilizzati due fantocci; il primo, chiamato Catphan 600 è il fantoccio utilizzato per caratterizzare i sistemi CT. Il secondo, chiamato Cirs 061 ha al suo interno degli inserti che simulano la presenza di lesioni con densità tipiche del distretto addominale. Lo studio effettuato ha evidenziato che, per entrambi i fantocci, il rapporto contrasto-rumore aumenta se si utilizza la tecnica di ricostruzione iterativa. La seconda parte del lavoro di tesi è stata quella di effettuare una valutazione della riduzione della dose prendendo in considerazione diversi protocolli utilizzati nella pratica clinica, si sono analizzati un alto numero di esami e si sono calcolati i valori medi di CTDI e DLP su un campione di esame con FBP e con iDose4. I risultati mostrano che i valori ricavati con l'utilizzo dell'algoritmo iterativo sono al di sotto dei valori DLR nazionali di riferimento e di quelli che non usano i sistemi iterativi.
Radiotherapy with scanning carbon ion beams: biological dose analysis for partial treatment delivery
Resumo:
L’uso di particelle cariche pesanti in radioterapia prende il nome di adroterapia. L’adroterapia permette l’irraggiamento di un volume bersaglio minimizzando il danno ai tessuti sani circostanti rispetto alla radioterapia tradizionale a raggi X. Le proprietà radiobiologiche degli ioni carbonio rappresentano un problema per i modelli radiobiologici a causa della non linearità della loro efficacia biologica. In questa tesi presenteremo gli algoritmi che possono essere usati per calcolare la dose fisica e biologica per un piano di trattamento del CNAO (Centro Nazionale Adroterapia Oncologica). Un caso di particolare interesse è l’eventualità che un piano di trattamento venga interrotto prima del dovuto. A causa della non linearità della sopravvivenza cellulare al variare della quantità di dose ricevuta giornalmente, è necessario studiare gli effetti degli irraggiamenti parziali utilizzando algoritmi che tengano conto delle tante variabili che caratterizzano sia i fasci di ioni che i tessuti irraggiati. Nell'ambito di questa tesi, appositi algoritmi in MATLAB sono stati sviluppati e implementati per confrontare la dose biologica e fisica assorbita nei casi di trattamento parziale.
Resumo:
Volumetric data at micrometer level resolution can be acquired within a few minutes using synchrotron-radiation-based tomographic microscopy. The field of view along the rotation axis of the sample can easily be increased by stacking several tomograms, allowing the investigation of long and thin objects at high resolution. On the contrary, an extension of the field of view in the perpendicular direction is non-trivial. This paper presents an acquisition protocol which increases the field of view of the tomographic dataset perpendicular to its rotation axis. The acquisition protocol can be tuned as a function of the reconstruction quality and scanning time. Since the scanning time is proportional to the radiation dose imparted to the sample, this method can be used to increase the field of view of tomographic microscopy instruments while optimizing the radiation dose for radiation-sensitive samples and keeping the quality of the tomographic dataset on the required level. This approach, dubbed wide-field synchrotron radiation tomographic microscopy, can increase the lateral field of view up to five times. The method has been successfully applied for the three-dimensional imaging of entire rat lung acini with a diameter of 4.1 mm at a voxel size of 1.48 microm.
Resumo:
The rapid technical advances in computed tomography have led to an increased number of clinical indications. Unfortunately, at the same time the radiation exposure to the population has also increased due to the increased total number of CT examinations. In the last few years various publications have demonstrated the feasibility of radiation dose reduction for CT examinations with no compromise in image quality and loss in interpretation accuracy. The majority of the proposed methods for dose optimization are easy to apply and are independent of the detector array configuration. This article reviews indication-dependent principles (e.g. application of reduced tube voltage for CT angiography, selection of the collimation and the pitch, reducing the total number of imaging series, lowering the tube voltage and tube current for non-contrast CT scans), manufacturer-dependent principles (e.g. accurate application of automatic modulation of tube current, use of adaptive image noise filter and use of iterative image reconstruction) and general principles (e.g. appropriate patient-centering in the gantry, avoiding over-ranging of the CT scan, lowering the tube voltage and tube current for survey CT scans) which lead to radiation dose reduction.
Resumo:
A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.
Resumo:
The electron Monte Carlo (eMC) dose calculation algorithm available in the Eclipse treatment planning system (Varian Medical Systems) is based on the macro MC method and uses a beam model applicable to Varian linear accelerators. This leads to limitations in accuracy if eMC is applied to non-Varian machines. In this work eMC is generalized to also allow accurate dose calculations for electron beams from Elekta and Siemens accelerators. First, changes made in the previous study to use eMC for low electron beam energies of Varian accelerators are applied. Then, a generalized beam model is developed using a main electron source and a main photon source representing electrons and photons from the scattering foil, respectively, an edge source of electrons, a transmission source of photons and a line source of electrons and photons representing the particles from the scrapers or inserts and head scatter radiation. Regarding the macro MC dose calculation algorithm, the transport code of the secondary particles is improved. The macro MC dose calculations are validated with corresponding dose calculations using EGSnrc in homogeneous and inhomogeneous phantoms. The validation of the generalized eMC is carried out by comparing calculated and measured dose distributions in water for Varian, Elekta and Siemens machines for a variety of beam energies, applicator sizes and SSDs. The comparisons are performed in units of cGy per MU. Overall, a general agreement between calculated and measured dose distributions for all machine types and all combinations of parameters investigated is found to be within 2% or 2 mm. The results of the dose comparisons suggest that the generalized eMC is now suitable to calculate dose distributions for Varian, Elekta and Siemens linear accelerators with sufficient accuracy in the range of the investigated combinations of beam energies, applicator sizes and SSDs.
Resumo:
BACKGROUND: Lung retrieval from non-heart-beating donors (NHBD) has been introduced into clinical practice successfully. However, because of potentially deleterious effects of warm ischemia on microvascular integrity, use of NHBD lungs is limited by short tolerable time periods before preservation. Recently, improvement of NHBD graft function was demonstrated by donor pre-treatment using aerosolized Ventavis (Schering Inc., Berlin, Germany). Currently, there is no information whether additional application of this approach in reperfusion can further optimize immediate graft function. MATERIAL AND METHODS: Asystolic pigs (n = 5/group) were ventilated for 180-min of warm ischemia (groups 1-3). In groups 2 and 3, 100 microg Ventavis were aerosolized over 30-min using an ultrasonic nebulizer (Optineb). Lungs were then retrogradely preserved with Perfadex and stored for 3-h. After left lung transplantation and contralateral lung exclusion, grafts were reperfused for 6-h. Only in group 3, another dose of 100 microg Ventavis was aerosolized during the first 30-min of reperfusion. Hemodynamics, pO2/FiO2 and dynamic compliance were monitored continuously and compared to controls. Intraalveolar edema was quantified stereologically, and extravascular-lung-water-index (EVLWI) was measured. Statistics comprised ANOVA analysis with repeated measurements. RESULTS: Dynamic compliance was significantly lower in both Ventavis groups, but additional administration did not result in further improvement. Oxygenation, pulmonary hemodynamics, EVLWI and intraalveolar edema formation were comparable between groups. CONCLUSIONS: Alveolar deposition of Ventavis in NHBD lungs before preservation significantly improves dynamic lung compliance and represents an important strategy for improvement of preservation quality and expansion of warm ischemic intervals. However, additional application of this method in early reperfusion is of no benefit.
Resumo:
A multicenter trial was performed to confirm the therapeutic efficacy and the toxicity profile of the combination of cladribine, cyclophosphamide and prednisone in low-grade non-Hodgkin's lymphoma (NHL) and chronic lymphocytic leukemia (CLL). Twenty-three adults with previously treated (61%) or untreated (39%) NHL International Working Formulation A or Binet B and C CLL were administered cladribine 0.1 mg/kg/day as a subcutaneous bolus for 5 days, intravenous cyclophosphamide 500 mg/m2 on day 1, and oral prednisone 40 mg/m2 on days 1-5, every 4 weeks. Unexpected early hematological toxicities led to dose modifications for pretreated patients who received cladribine for 3 days only up to a maximum of five courses. Responses were observed in 75%, with 7 patients obtaining a complete clinical and hematological response. Median duration of complete response was 9 months. Median time to progression or relapse was 31 months. Myelosuppression and infections were dose limiting whereas posttreatment complications, including fatalities, resulted from infections. Median overall survival time from trial entry was 60 months. Activity of the combination of cladribine, cyclophosphamide and prednisone was confirmed. However, in the specific setting of a multicenter trial, unexpected fatal infectious episodes occurred in pretreated patients. Great caution is thus required in these susceptible patients and the routine use of corticosteroids should probably be abandoned.
Resumo:
Having determined in a phase I study the maximum tolerated dose of high-dose ifosfamide combined with high-dose doxorubicin, we now report the long-term results of a phase II trial in advanced soft-tissue sarcomas. Forty-six patients with locally advanced or metastatic soft-tissue sarcomas were included, with age <60 years and all except one in good performance status (0 or 1). The chemotherapy treatment consisted of ifosfamide 10 g m(-2) (continuous infusion for 5 days), doxorubicin 30 mg m(-2) day(-1) x 3 (total dose 90 mg m(-2)), mesna and granulocyte-colony stimulating factor. Cycles were repeated every 21 days. A median of 4 (1-6) cycles per patient was administered. Twenty-two patients responded to therapy, including three complete responders and 19 partial responders for an overall response rate of 48% (95% CI: 33-63%). The response rate was not different between localised and metastatic diseases or between histological types, but was higher in grade 3 tumours. Median overall survival was 19 months. Salvage therapies (surgery and/or radiotherapy) were performed in 43% of patients and found to be the most significant predictor for favourable survival (exploratory multivariate analysis). Haematological toxicity was severe, including grade > or =3 neutropenia in 59%, thrombopenia in 39% and anaemia in 27% of cycles. Three patients experienced grade 3 neurotoxicity and one patient died of septic shock. This high-dose regimen is toxic but nonetheless feasible in multicentre settings in non elderly patients with good performance status. A high response rate was obtained. Prolonged survival was mainly a function of salvage therapies.
Resumo:
Several lines of evidence support an important role for somatostatin receptors (SSTRs) in pain modulation. The therapeutic use of established SSTR peptide agonists for this indication is limited by their broad range of effects, need for intrathecal delivery, and short half-life. Therefore, the goal of the present study was to investigate the analgesic effect of SCR007, a new, highly selective SSTR2 non-peptide agonist. Behavioral studies demonstrated that paw withdrawal latencies to heat were significantly increased following intraplantar SCR007. Furthermore, both intraperitoneal and intraplantar injection of SCR007 significantly reduced formalin- and capsaicin-induced flinching and lifting/licking nociceptive behaviors. Recordings from nociceptors using an in vitro glabrous skin-nerve preparation showed that SCR007 reduced heat responses in a dose-dependent fashion, bradykinin-induced excitation, heat sensitization and capsaicin-induced excitation. In both the behavioral and single fiber studies, the SCR007 effects were reversed by the SSTR antagonist cyclo-somatostatin, demonstrating receptor specificity. In the single fiber studies, the opioid antagonist naloxone did not reverse SCR007-induced anti-nociception suggesting that SCR007 did not exert its effects through activation of opioid receptors. Analysis of cAMP/protein kinase A (PKA) involvement demonstrated that SCR007 prevented forskolin- and Sp-8-Br-cAMPS (a PKA activator)-induced heat sensitization, supporting the hypothesis that SCR007-induced inhibition could involve a down-regulation of the cAMP/PKA pathway. These data provide several lines of evidence that the non-peptide imidazolidinedione SSTR2 agonist SCR007 is a promising anti-nociceptive and analgesic agent for the treatment of pain of peripheral and/or central origin.
Resumo:
In progressive immunoglobulin A nephropathy (IgAN), intravenous immunoglobulin (IVIg) treatment has been used to delay disease progression, but the long-term efficacy is largely unknown. We report the clinical outcomes after IVIg therapy in six male patients with progressive IgAN [median glomerular filtration rate (GFR) 31 ml/min per 1.73 m(2)] followed for a median observation period of 8 years. In this single-arm, non-randomized study, IVIg was given monthly at a dose of 2 g/kg body weight for 6 months. The course of renal function was assessed by linear regression analysis of GFR and proteinuria, and was compared to eight patients with IgAN (median GFR 29 ml/min per 1.73 m(2)) without IVIg as a contemporaneous control group. IgAN disease progression was delayed after IVIg therapy on average for 3 years. The mean loss of renal function decreased from -1.05 ml/min per month to -0.15 ml/min per month (P = 0.024) and proteinuria decreased from 2.4 g/l to 1.0 g/l (P = 0.015). The primary end-point (GFR < 10 ml/min or relapse) occurred 5.2 years (median; range 0.4-8.8) after the first IVIg pulse, and after 1.3 years (median; range 0.8-2.4) in the control group (P = 0.043). In Kaplan-Meier analysis, the median renal survival time with IVIg was prolonged by 3.5 years (IVIg 4.7 years versus control 1.2 years; P = 0.006). IVIg pulse therapy may be considered as a treatment option to reduce the loss of renal function and improve proteinuria in patients with progressive IgAN.
Resumo:
The aim was to investigate the efficacy of a combination of low-dose remifentanil (REMI) and ketamine (KET) compared to the single drugs and placebo (P) on whiplash associated pain (WAD) in a double-blind, randomized, placebo-controlled, cross-over study. Twenty patients with chronic (>1 year) WAD were included. Four different drug combinations were tested in four sessions: placebo/placebo (P/P), placebo/remifentanil (P/REMI), ketamine/placebo (KET/P) and ketamine/remifentanil (KET/REMI). Target concentrations were 1 and 2ng/ml (stepwise) for remifentanil and 100ng/ml for ketamine. Habitual pain intensity was assessed on a visual analogue scale (VAS). Experimental pain was assessed with electrical stimulation (single and repeated) of tibialis anterior (TA) muscle, pressure pain algometry applied over infraspinatus (IS) and TA muscles and VAS scores after intramuscular hypertonic saline infusion in TA. KET/REMI significantly reduced habitual pain. KET/REMI infused at low REMI target concentration (1ng/ml) significantly elevated electrical intramuscular pain thresholds (single and repeated). Pain thresholds to electrical stimulation were similarly increased by both P/REMI and KET/REMI at 2ng/ml target concentration. Pressure pain thresholds were increased by both KET/REMI and P/REMI. VAS-scores after intramuscular saline were also similarly decreased by both REMI combinations. Seven out of 20 subjects were non-responders (<50% pain relief). No correlation was found between effects on spontaneous pain and experimental pain. KET/REMI showed an analgesic effect on habitual pain. Experimental pain was attenuated by both combinations containing the opioid, however, KET seemed to enhance the effect of REMI on electrical pain thresholds when a low REMI target concentration was used.
Resumo:
In this prospective, non-randomized 6-month observational study we evaluated the efficacy of intravenous immunoglobulin (IVIg) dose increase in patients with multifocal motor neuropathy (MMN). Diagnosis according to AAEM criteria, repetitive IVIg treatment for at least one year, persistent paresis and conduction block, stable symptoms and findings for at least six months were inclusion criteria. Nine patients (7 men) were identified and approved to standardized increase of IVIg dose. Patients were monitored using clinical scores and electrophysiological studies. Dose was increased from a baseline of 0.5 g/kg per month [mean, range: 0.1-1.1], given at variable intervals [4-12 weeks] to 1.2 g/kg per month given over 3 consecutive days planned for 6 cycles. If the patients' motor function did not improve after two cycles they entered step two: Dose was increased to 2 g/kg per month given over 5 consecutive days. The increased dose was maintained for 6 months. Assessments were performed by the same investigator, not involved in the patient's management, at baseline, after 2 and after 6 months. Following dose increase, motor function significantly improved in 6 patients (p = 0.014), 2 patients entered step two, 1 patient withdrew due to absent efficacy. Higher doses of IVIg caused more side effects, however, transient and rarely severe (p = 0.014). IVIg dose increase may improve motor functions in patients with stable MMN on long-term IVIg therapy independent of baseline dose. Improvement of motor function was associated with shorter disease duration (p = 0.008), but not with degree of muscle atrophy (p = 0.483). The treatment strategy to try to find the lowest effective dose and the longest tolerated interval might lead to underdosing in the long-term in many patients.