891 resultados para Correction de textures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Assessment of lung volume (FRC) and ventilation inhomogeneities with ultrasonic flowmeter and multiple breath washout (MBW) has been used to provide important information about lung disease in infants. Sub-optimal adjustment of the mainstream molar mass (MM) signal for temperature and external deadspace may lead to analysis errors in infants with critically small tidal volume changes during breathing. METHODS: We measured expiratory temperature in human infants at 5 weeks of age and examined the influence of temperature and deadspace changes on FRC results with computer simulation modeling. A new analysis method with optimized temperature and deadspace settings was then derived, tested for robustness to analysis errors and compared with the previously used analysis methods. RESULTS: Temperature in the facemask was higher and variations of deadspace volumes larger than previously assumed. Both showed considerable impact upon FRC and LCI results with high variability when obtained with the previously used analysis model. Using the measured temperature we optimized model parameters and tested a newly derived analysis method, which was found to be more robust to variations in deadspace. Comparison between both analysis methods showed systematic differences and a wide scatter. CONCLUSION: Corrected deadspace and more realistic temperature assumptions improved the stability of the analysis of MM measurements obtained by ultrasonic flowmeter in infants. This new analysis method using the only currently available commercial ultrasonic flowmeter in infants may help to improve stability of the analysis and further facilitate assessment of lung volume and ventilation inhomogeneities in infants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the performance of a new motion correction algorithm. Twenty-five dynamic MR mammography (MRM) data sets and 25 contrast-enhanced three-dimensional peripheral MR angiographic (MRA) data sets which were affected by patient motion of varying severeness were selected retrospectively from routine examinations. Anonymized data were registered by a new experimental elastic motion correction algorithm. The algorithm works by computing a similarity measure for the two volumes that takes into account expected signal changes due to the presence of a contrast agent while penalizing other signal changes caused by patient motion. A conjugate gradient method is used to find the best possible set of motion parameters that maximizes the similarity measures across the entire volume. Images before and after correction were visually evaluated and scored by experienced radiologists with respect to reduction of motion, improvement of image quality, disappearance of existing lesions or creation of artifactual lesions. It was found that the correction improves image quality (76% for MRM and 96% for MRA) and diagnosability (60% for MRM and 96% for MRA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Suburethral slings are commonly used for the surgical treatment of female stress incontinence; occasionally they can cause erosion and dyspareunia. OBJECTIVES: The primary aim of this study is to determine the outcome after reclosure of the vaginal epithelium for suburethral sling erosion. Sexual function was assessed before and after intervention using the Female Sexual Function Index (FSFI) questionnaire. DESIGN, SETTING, AND PARTICIPANTS: This was a prospective case-controlled study in which, between December 2005 and December 2007, we included patients who were referred to the Department of Urogynaecology because of vaginal erosion after suburethral sling insertion for urinary stress incontinence. For evaluation of sexual function, all patients filled in an FSFI questionnaire before intervention and at follow-up. All patients underwent gynaecological examination including colposcopy, and the site and size of the defect were noted. INTERVENTION: The edge of the vaginal epithelium was trimmed, mobilized, and closed with interrupted vertical Vicryl mattress sutures in a single layer. MEASUREMENTS: FSFI questionnaire and clinical findings. RESULTS AND LIMITATIONS: Twenty-one patients were included in the study. Eighteen patients with larger defects were operated on, and three defects healed after topical application of estrogen cream. In 16 patients, the defect had healed at follow-up; two patients with persisting defects were brought back to surgery and the procedure was repeated, paying particular attention to tension-free adaptation of vaginal tissue. In one patient, partial sling removal was performed after the second failed intervention. The domains of desire (p<0.0001), arousal (p<0.0003), lubrication (p<0.0001), satisfaction (p<0.0130), and pain (p<0.0001) improved significantly. Orgasm remained unchanged (p=0.4130; all two-tailed t-test). CONCLUSION: Suburethral erosion can be treated effectively by resuturing. Sexual function is improved in regard to desire, arousal, lubrication, satisfaction, and pain, but not orgasm. In septic patients and patients with a history of radiation, grossly infected tissue, or severe pain, excision of the mesh needs to be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Switching mode power supplies (SMPS) are subject to low power factor and high harmonic distortions. Active power-factor correction (APFC) is a technique to improve the power factor and to reduce the harmonic distortion of SMPSs. However, this technique results in double frequency output voltage variation which can be reduced by using a large output capacitance. Using large capacitors increases the cost and size of the converter. Furthermore, the capacitors are subject to frequent failures mainly caused by evaporation of the electrolytic solution which reduce the converter reliability. This thesis presents an optimal control method for the input current of a boost converter to reduce the size of the output capacitor. The optimum current waveform as a function of weighing factor is found by using the Euler Lagrange equation. A set of simulations are performed to determine the ideal weighing which gives the lowest possible output voltage variation as the converter still meets the IEC-61000-3-2 class-A harmonics requirements with a power factor of 0.8 or higher. The proposed method is verified by the experimental work. A boost converter is designed and it is run for different power levels, 100 W, 200 W and 400 W. The desired output voltage ripple is 10 V peak to peak for the output voltage of 200 Vdc. This ripple value corresponds to a ± 2.5% output voltage ripple. The experimental and the simulation results are found to be quite matching. A significant reduction in capacitor size, as high as 50%, is accomplished by using the proposed method.