848 resultados para Corneal Sensitivity
Resumo:
To identify early metabolic abnormalities in type 2 diabetes mellitus, we measured insulin secretion, sensitivity to insulin, and hepatic insulin extraction in 48 healthy normal glucose-tolerant Brazilians, first-degree relatives of type 2 diabetic patients (FH+). Each individual was matched for sex, age, weight, and body fat distribution with a person without history of type 2 diabetes (FH-). Both groups were submitted to a hyperglycemic clamp procedure (180 mg/dl). Insulin release was evaluated in its two phases. The first was calculated as the sum of plasma insulin at 2.5, 5.0, 7.5, and 10.0 min after the beginning of glucose infusion, and the second as the mean plasma insulin level in the third hour of the clamp procedure. Insulin sensitivity index (ISI) was the mean glucose infusion rate in the third hour of the clamp experiment divided by the mean plasma insulin concentration during the same period of time. Hepatic insulin extraction was determined under fasting conditions and in the third hour of the clamp procedure as the ratio between C-peptide and plasma insulin levels. FH+ individuals did not differ from FH- individuals in terms of the following parameters [median (range)]: a) first-phase insulin secretion, 174 (116-221) vs 207 (108-277) µU/ml, b) second-phase insulin secretion, 64 (41-86) vs 53 (37-83) µU/ml, and c) ISI, 14.8 (9.0-20.8) vs 16.8 (9.0-27.0) mg kg-1 min-1/µU ml-1. Hepatic insulin extraction in FH+ subjects was similar to that of FH- ones at basal conditions (median, 0.27 vs 0.27 ng/µU) and during glucose infusion (0.15 vs 0.15 ng/µU). Normal glucose-tolerant Brazilian FH+ individuals well-matched with FH- ones did not show defects of insulin secretion, insulin sensitivity, or hepatic insulin extraction as tested by hyperglycemic clamp procedures.
Resumo:
The cornea is a curved and transparent structure that provides the initial focusing of a light image into the eye. It consists of a central stroma that constitutes 90% of the corneal depth, covered anteriorly with epithelium and posteriorly with endothelium. Its transparency is the result of the regular spacing of collagen fibers with remarkably uniform diameter and interfibrillar space. Corneal collagen is composed of heterotypic fibrils consisting of type I and type V collagen molecules. The cornea also contains unusually high amounts of type VI collagen, which form microfibrillar structures, FACIT collagens (XII and XIV), and other nonfibrillar collagens (XIII and XVIII). FACIT collagens and other molecules, such as leucine-rich repeat proteoglycans, play important roles in modifying the structure and function of collagen fibrils.Proteoglycans are macromolecules composed of a protein core with covalently linked glycosaminoglycan side chains. Four leucine-rich repeat proteoglycans are present in the extracellular matrix of corneal stroma: decorin, lumican, mimecan and keratocan. The first is a dermatan sulfate proteoglycan, and the other three are keratan sulfate proteoglycans. Experimental evidence indicates that the keratan sulfate proteoglycans are involved in the regulation of collagen fibril diameter, and dermatan sulfate proteoglycan participates in the control of interfibrillar spacing and in the lamellar adhesion properties of corneal collagens. Heparan sulfate proteoglycans are minor components of the cornea, and are synthesized mainly by epithelial cells. The effect of injuries on proteoglycan synthesis is discussed.
Resumo:
When contrast sensitivity functions to Cartesian and angular gratings were compared in previous studies the peak sensitivity to angular stimuli was reported to be 0.21 log units higher. In experiments carried out to repeat this result, we used the same two-alternative forced-choice paradigm, but improved experimental control and precision by increasing contrast resolution from 8 to 12 bits, increasing the screen refresh rate from 30 Hz interlaced to 85 Hz non-interlaced, linearizing the voltage-luminance relation, modulating luminance in frequencies that minimize pixel aliasing, and improving control of the subject's exposure to the stimuli. The contrast sensitivity functions to Cartesian and angular gratings were similar in form and peak sensitivity (2.4 cycles per visual degree (c/deg) and 32 c/360º, respectively) to those reported in a previous study (3 c/deg and 32 c/360º, respectively), but peak sensitivity to angular stimuli was 0.13 log units lower than that to Cartesian stimuli. When the experiment was repeated, this time simulating the experimental control level used in the previous study, no difference between the peak sensitivity to Cartesian and angular stimuli was found. This result agrees with most current models that assume Cartesian filtering at the first visual processing stage. The discrepancy in the results is explained in part by differences in the degree of experimental control.
Resumo:
The aim of the present study was to measure contrast sensitivity curves for angular frequencies in the range between 2 and 96 cycles/360º in older human adult volunteers and to compare these measurements with the more usual contrast sensitivity functions for sine-wave gratings. All subjects were free of identifiable ocular disease and had normal acuity. We measured the contrast thresholds for young adults (N = 6; age range, 20-26 years) and older adults (N = 6; age range, 60-67 years) using the psychophysical forced-choice method. In this paradigm the volunteers had to choose the stimulus containing a test frequency at low contrast (e.g., either a sine-wave grating or an angular frequency stimulus), or another neutral stimulus at mean luminance (without any contrast). Older adults presented a loss in contrast sensitivity at high and medium angular frequencies compared to the young adults (i.e., from 8 to 96 cycles/360º). Contrary to expectation, contrast sensitivity at low angular frequencies, i.e., 2 and 4 cycles/360º, was better for the older group than for the younger group. On the other hand, contrast sensitivity for sine-wave gratings at 3 and 4 cpd was higher for young adults as expected. These results suggest age-related changes in the contrast sensitivity function for angular frequencies.
Resumo:
The present study was designed to compare the homeostasis model assessment (HOMA) and quantitative insulin sensitivity check index (QUICKI) with data from forearm metabolic studies of healthy individuals and of subjects in various pathological states. Fifty-five healthy individuals and 112 patients in various pathological states, including type 2 diabetes mellitus, essential hypertension and others, were studied after an overnight fast and for 3 h after ingestion of 75 g of glucose, by HOMA, QUICKI and the forearm technique to estimate muscle uptake of glucose combined with indirect calorimetry (oxidative and non-oxidative glucose metabolism). The patients showed increased HOMA (1.88 ± 0.14 vs 1.13 ± 0.10 pmol/l x mmol/l) and insulin/glucose (I/G) index (1.058.9 ± 340.9 vs 518.6 ± 70.7 pmol/l x (mg/100 ml forearm)-1), and decreased QUICKI (0.36 ± 0.004 vs 0.39 ± 0.006 (µU/ml + mg/dl)-1) compared with the healthy individuals. Analysis of the data for the group as a whole (patients and healthy individuals) showed that the estimate of insulin resistance by HOMA was correlated with data obtained in the forearm metabolic studies (glucose uptake: r = -0.16, P = 0.04; non-oxidative glucose metabolism: r = -0.20. P = 0.01, and I/G index: r = 0.17, P = 0.03). The comparison of QUICKI with data of the forearm metabolic studies showed significant correlation between QUICKI and non-oxidative glucose metabolism (r = 0.17, P = 0.03) or I/G index (r = -0.37, P < 0.0001). The HOMA and QUICKI are good estimates of insulin sensitivity as data derived from forearm metabolic studies involving direct measurements of insulin action on muscle glucose metabolism.
Resumo:
In order to develop a new experimental animal model of infection with Mycobacterium chelonae in keratomileusis, we conducted a double-blind prospective study on 24 adult male New Zealand rabbits. One eye of each rabbit was submitted to automatic lamellar keratotomy with the automatic corneal shaper under general anesthesia. Eyes were immunosuppressed by a single local injection of methyl prednisolone. Twelve animals were inoculated into the keratomileusis interface with 1 µl of 10(6) heat-inactivated bacteria (heat-inactivated inoculum controls) and 12 with 1 µl of 10(6) live bacteria. Trimethoprim drops (0.1%, w/v) were used as prophylaxis for the surgical procedure every 4 h (50 µl, qid). Animals were examined by 2 observers under a slit lamp on the 1st, 3rd, 5th, 7th, 11th, 16th, and 23rd postoperative days. Slit lamp photographs were taken to document clinical signs. Animals were sacrificed when corneal disease was detected and corneal samples were taken for microbiological analysis. Eleven of 12 experimental rabbits developed corneal disease, and M. chelonae could be isolated from nine rabbits. Eleven of the 12 controls receiving a heat-inactivated inoculum did not develop corneal disease. M. chelonae was not isolated from any of the control rabbits receiving a heat-inactivated inoculum, or from the healthy cornea of control rabbits. Corneal infection by M. chelonae was successfully induced in rabbits submitted to keratomileusis. To our knowledge, this is the first animal model of M. chelonae infection following corneal flaps for refractive surgery to be described in the literature and can be used for the analysis of therapeutic responses.
Resumo:
Although healthy preterm infants frequently seem to be more attentive to visual stimuli and to fix on them longer than full-term infants, no difference in visual acuity has been reported compared to term infants. We evaluated the contrast sensitivity (CS) function of term (N = 5) and healthy preterm (N = 11) infants at 3 and 10 months of life using sweep-visual evoked potentials. Two spatial frequencies were studied: low (0.2 cycles per degrees, cpd) and medium (4.0 cpd). The mean contrast sensitivity (expressed in percentage of contrast) of the preterm infants at 3 months was 55.4 for the low spatial frequency (0.2 cpd) and 43.4 for the medium spatial frequency (4.0 cpd). At 10 months the low spatial CS was 52.7 and the medium spatial CS was 9.9. The results for the term infants at 3 months were 55.1 for the low spatial frequency and 34.5 for the medium spatial frequency. At 10 months the equivalent values were 54.3 and 14.4, respectively. No difference was found using the Mann-Whitney rank sum T-test between term and preterm infants for the low frequency at 3 or 10 months or for the medium spatial frequency at 3 or 10 months. The development of CS for the medium spatial frequency was equally fast for term and preterm infants. As also observed for visual acuity, CS was equivalent among term and preterm infants, suggesting that visual experience does not modify the development of the primary visual pathway. An earlier development of synapses in higher cortical visual areas of preterm infants could explain the better use of visual information observed behaviorally in these infants.
Resumo:
To examine the possible age-related blood pressure (BP) deregulation in response to central hypervolemia, we measured spontaneous baroreflex sensitivity (SBRS), carotid arterial compliance (CC), and R-R interval coefficient of variation (RRICV) during basal and thermoneutral resting head-out-of-water immersion (HOWI) in 7 young (YG = 24.0 ± 0.8 years) and 6 middle-aged/older (OL = 59.3 ± 1.3 years) healthy men. Compared with basal conditions (YG = 19.6 ± 4.0 vs OL = 6.1 ± 1.5 ms/mmHg, P < 0.05), SBRS remained higher in YG than OL during rest HOWI (YG = 23.6 ± 6.6 vs OL = 9.3 ± 2.1 ms/mmHg, P < 0.05). The RRICV was significantly different between groups (YG = 6.5 ± 1.4 vs OL = 2.8 ± 0.4%, P < 0.05) under HOWI. The OL group had no increase in CC, but a significant increase in systolic BP (basal = 115.3 ± 4.4 vs water = 129.3 ± 5.3 mmHg, P < 0.05) under HOWI. In contrast, the YG group had a significant increase in CC (basal = 0.16 ± 0.01 vs water = 0.17 ± 0.02 mm²/mmHg, P < 0.05) with no changes in systolic BP. SBRS was positively related to CC (r = 0.58, P < 0.05 for basal vs r = 0.62, P < 0.05 for water). Our data suggest that age-related vagal dysfunction and reduced CC may be associated with SBRS differences between YG and OL groups, and with BP elevation during HOWI in healthy older men.
Resumo:
Our objective was to study the effect of dorzolamide on corneal hydration in an 18-week controlled experiment using ultrasonic pachymetry. Twenty-eight male rabbits were divided randomly into four groups. The 7 rabbits in each group received eye drops containing either 2% (w/v) dorzolamide or placebo in their right eye, or in their left eye. The 2% dorzolamide rabbits were treated every 8 h. Fellow eyes are defined as eyes which did not receive either dorzolamide or placebo. The study was blind for both the person who applied the drug and the one who performed the pachymetry. The effect of treatments is reported on the basis of the percentage of pachymetric variation compared to the measurement made before drug application. There was no significant difference (P = 0.061) in pachymetric variation between dorzolamide (-4.42 ± 11.71%) and placebo (2.48 ± 9.63%). However, there was a significant difference (P = 0.0034) in pachymetric variation between the dorzolamide fellow eyes (-7.56 ± 10.50%) and the placebo (-4.42 ± 11.71%). In conclusion, dorzolamide did not increase the corneal thickness in rabbits.
Resumo:
The objective of the present study was to determine contrast sensitivity curves of concentric circular patterns with radial frequencies of 0.25, 0.5, 1.0, 2.0, and 4.0 cycles per degree in young and older adult volunteers. These parameters were also compared with sensitivity contrasts for sine-wave gratings. All participants had normal acuity vision and were free of identifiable ocular illness. Contrast sensitivity was measured in 6 young adults aged 19 to 23 years and 6 older adults aged 60 to 69 years using the psychophysical forced-choice method. In this paradigm the volunteers had to decide which of two stimuli contained the above radial frequencies at low contrast levels. The other neutral stimulus was gray with homogeneous luminance. We detected a decline in contrast sensitivity for older adults at all radial frequencies compared to young adults. Also, contrast sensitivity for sine-wave gratings at all measured frequencies was better, as predicted, for all young adults. Maximum sensitivities in the radial frequency contrast sensitivity function and contrast sensitivity function occurred at 0.25 and 0.5 cycles per degree, respectively, for both young and older adults. These results suggest age-related changes in the contrast sensitivity function for concentric symmetrical stimuli.
Resumo:
Several methods have been described to measure intraocular pressure (IOP) in clinical and research situations. However, the measurement of time varying IOP with high accuracy, mainly in situations that alter corneal properties, has not been reported until now. The present report describes a computerized system capable of recording the transitory variability of IOP, which is sufficiently sensitive to reliably measure ocular pulse peak-to-peak values. We also describe its characteristics and discuss its applicability to research and clinical studies. The device consists of a pressure transducer, a signal conditioning unit and an analog-to-digital converter coupled to a video acquisition board. A modified Cairns trabeculectomy was performed in 9 Oryctolagus cuniculus rabbits to obtain changes in IOP decay parameters and to evaluate the utility and sensitivity of the recording system. The device was effective for the study of kinetic parameters of IOP, such as decay pattern and ocular pulse waves due to cardiac and respiratory cycle rhythm. In addition, there was a significant increase of IOP versus time curve derivative when pre- and post-trabeculectomy recordings were compared. The present procedure excludes corneal thickness and error related to individual operator ability. Clinical complications due to saline infusion and pressure overload were not observed during biomicroscopic evaluation. Among the disadvantages of the procedure are the requirement of anesthesia and the use in acute recordings rather than chronic protocols. Finally, the method described may provide a reliable alternative for the study of ocular pressure dynamic alterations in man and may facilitate the investigation of the pathogenesis of glaucoma.
Resumo:
In addition to lipid-lowering and cardiovascular protective actions, statins may have beneficial effects on insulin sensitivity. The objective of the present study was to evaluate the effect of simvastatin therapy on insulin resistance and on leptin, adiponectin, and C-reactive protein (CRP) levels, as compared to metformin, in overweight pre-diabetic subjects. Forty-one subjects with BMI >25 kg/m² and impaired fasting glucose or impaired glucose tolerance were randomized to take simvastatin, 20 mg/day (N = 20) or metformin, 1.7 g/day (N = 21) for 16 weeks. Blood samples for the determination of metabolic, hormonal, and inflammatory parameters were obtained at baseline and after each treatment. After metformin therapy, significant reductions in mean BMI and waist circumference were observed, and after simvastatin treatment LDL and triglyceride levels were significantly reduced. Insulin resistance determined by the homeostasis model assessment decreased only with metformin. Independently of the type of medication, a significant decrease in CRP levels was detected from baseline to the end of the study. CRP showed a mean reduction of 0.12 ± 0.04 mg/dL (P = 0.002) over time. No change in leptin or adiponectin levels was induced by any therapy. The data suggest that a low dose of simvastatin does not affect insulin resistance in overweight pre-diabetic subjects and has no effect on leptin or adiponectin levels. Further studies including a larger sample size, higher doses of statins, and a placebo control group are necessary to confirm the present data.
Resumo:
The in vitro ability of Pothomorphe umbellata ethanolic crude extract to inhibit matrix metalloproteinase (MMP) in normal cornea and in cornea after alkali injury was demonstrated. Corneas of albino rabbits were injured with 1 N NaOH for 20 s. After 48 h the corneas were excised, homogenized and analyzed for MMP-9 (92 kDa), pro-MMP-2 (72 kDa) and MMP-2 (67 kDa) activity by gelatin zymography. The activity was also measured in untreated corneas. After electrophoresis of 20 µg protein, gels were incubated with 50, 100, or 250 µg/mL lyophilized hydroethanolic (1:1) root crude extract of P. umbellata standardized for 4-nerolidylcatechol (7.09%). The activity of the enzymes was compared with that of untreated gel. At 48 h after injury, the activity of all MMPs was increased compared with untreated eyes. When the gels were incubated with P. umbellata extract the activity of MMP-2, pro-MMP-2 and MMP-9 decreased in a dose-dependent manner. MMP-9 activity decreased by approximately 50% after incubation with 50 µg/mL and was completely abolished at 100 and 250 µg/mL of the extract. After incubation with 50 µg/mL the activity of pro-MMP-2 and MMP-2 also decreased by 50%. The activity of pro-MMP-2 was almost completely abolished after incubation with 250 µg/mL of the extract. For MMP-2 the incubation with 100 or 250 µg/mL of the extract of P. umbellata promoted a 10-fold decrease in activity. In conclusion, P. umbellata root crude extract can be useful as an alternative therapy to control MMP activity after corneal injury.
Resumo:
We measured visual performance in achromatic and chromatic spatial tasks of mercury-exposed subjects and compared the results with norms obtained from healthy individuals of similar age. Data were obtained for a group of 28 mercury-exposed subjects, comprising 20 Amazonian gold miners, 2 inhabitants of Amazonian riverside communities, and 6 laboratory technicians, who asked for medical care. Statistical norms were generated by testing healthy control subjects divided into three age groups. The performance of a substantial proportion of the mercury-exposed subjects was below the norms in all of these tasks. Eleven of 20 subjects (55%) performed below the norms in the achromatic contrast sensitivity task. The mercury-exposed subjects also had lower red-green contrast sensitivity deficits at all tested spatial frequencies (9/11 subjects; 81%). Three gold miners and 1 riverine (4/19 subjects, 21%) performed worse than normal subjects making more mistakes in the color arrangement test. Five of 10 subjects tested (50%), comprising 2 gold miners, 2 technicians, and 1 riverine, performed worse than normal in the color discrimination test, having areas of one or more MacAdam ellipse larger than normal subjects and high color discrimination thresholds at least in one color locus. These data indicate that psychophysical assessment can be used to quantify the degree of visual impairment of mercury-exposed subjects. They also suggest that some spatial tests such as the measurement of red-green chromatic contrast are sufficiently sensitive to detect visual dysfunction caused by mercury toxicity.
Resumo:
Single-photon emission computed tomography (SPECT) is a non-invasive imaging technique, which provides information reporting the functional states of tissues. SPECT imaging has been used as a diagnostic tool in several human disorders and can be used in animal models of diseases for physiopathological, genomic and drug discovery studies. However, most of the experimental models used in research involve rodents, which are at least one order of magnitude smaller in linear dimensions than man. Consequently, images of targets obtained with conventional gamma-cameras and collimators have poor spatial resolution and statistical quality. We review the methodological approaches developed in recent years in order to obtain images of small targets with good spatial resolution and sensitivity. Multipinhole, coded mask- and slit-based collimators are presented as alternative approaches to improve image quality. In combination with appropriate decoding algorithms, these collimators permit a significant reduction of the time needed to register the projections used to make 3-D representations of the volumetric distribution of target’s radiotracers. Simultaneously, they can be used to minimize artifacts and blurring arising when single pinhole collimators are used. Representation images are presented, which illustrate the use of these collimators. We also comment on the use of coded masks to attain tomographic resolution with a single projection, as discussed by some investigators since their introduction to obtain near-field images. We conclude this review by showing that the use of appropriate hardware and software tools adapted to conventional gamma-cameras can be of great help in obtaining relevant functional information in experiments using small animals.