956 resultados para Conus-venom Peptides
Resumo:
A highly active cobra venom factor (CVF) was isolated from the venom of Naja kaouthia by sequential column chromatography. It displays strong anticomplementary activity, and has 1515 U of anti complementary activity per mg protein. A single dose of 0.1 mg/kg CVF given i.v. to rats completely abrogated complement activity for nearly 5 days. Given 0.02 mg/kg of CVF. the complement activity of rats was reduced by more than 96.5% in 6 It. In guinea pig-to-rat heart transplant model, rats treated with a single dose of 0.05 mg/kg CVF had significantly prolonged xenograft survival (56.12 +/- 6.27 h in CVF-treated rats vs. 0.19 +/- 0.07 h in control rats, P < 0.001). (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
A chymotrypsin inhibitor, designated NA-CI, was isolated from the venom of the Chinese cobra Naja atra by three-step chromatography. It inhibited bovine (x-chymotrypsin with a K-i of 25 nM. The molecular mass of NA-CI was determined to be 6403.8 Da by matrix-assisted laser-desorption ionization time-of-flight (MALDI-TOF) analysis. The complete amino acid sequence was determined after digestion of S-carboxymethylated inhibitor with Staphylococcus aureus V8 protease and porcine trypsin. NA-CI was a single polypeptide chain composed of 57 amino acid residues. The main contact site with the protease (PI) has a Phe, showing the specificity of the inhibitor. NA-CI shared great similarity with the chymotrypsin inhibitor from Naja naja venom (identities = 89.5%) and other snake venom protease inhibitors. (C) 2003 Elsevier Inc. All rights reserved.
Resumo:
L-Amino acid oxidases (LAAOs) are widely distributed in snake venoms, which contribute to the toxicity of venoms. However, LAAO from Bungarus fasciatus (B. fasciatus) snake venom has not been isolated previously. In the present study, LAAO from B. fasciat
Resumo:
Jerdonitin is a P-II class snake venom metalloproteinase comprising metalloproteinase and disintegrin domains. In this study, we established a high-level expression system in Pichia pastoris and developed a purification strategy for the recombinant Jerdonitin. This recombinant Jerdonitin degraded fibrinogen at a level of activity comparable with its wild type. The effects of recombinant Jerdonitin on inhibiting ADP-induced human platelet aggregation were in a dose-dependent manner with an IC50 of 248 nM. In addition, we reported here that Jerdonitin can significantly inhibit the growth of several cell lines, including human liver cancer cells (Bel7402), human leukemia cells (K562) and human gastric carcinoma cells (BGC823). This study offers recombinant Jerdonitin that will be valuable for further functional and structural studies of Jerdonitin. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
We study two distinctly ordered condensed phases of polypeptide molecules, amyloid fibrils and amyloidlike microcrystals, and the first-order twisting phase transition between these two states. We derive a single free-energy form which connects both phases. Our model identifies relevant degrees of freedom for describing the collective behavior of supramolecular polypeptide structures, reproduces accurately the results from molecular dynamics simulations as well as from experiments, and sheds light on the uniform nature of the dimensions of different peptide fibrils. © 2012 American Physical Society.
Resumo:
Cell-material interactions are crucial for cell adhesion and proliferation on biomaterial surfaces. Immobilization of biomolecules leads to the formation of biomimetic substrates, improving cell response. We introduced RGD (Arg-Gly-Asp) sequences on poly-ε-caprolactone (PCL) film surfaces using thiol chemistry to enhance Schwann cell (SC) response. XPS elemental analysis indicated an estimate of 2-3% peptide functionalization on the PCL surface, comparable with carbodiimide chemistry. Contact angle was not remarkably reduced; hence, cell response was only affected by chemical cues on the film surface. Adhesion and proliferation of Schwann cells were enhanced after PCL modification. Particularly, RGD immobilization increased cell attachment up to 40% after 6 h of culture. It was demonstrated that SC morphology changed from round to very elongated shape when surface modification was carried out, with an increase in the length of cellular processes up to 50% after 5 days of culture. Finally RGD immobilization triggered the formation of focal adhesion related to higher cell spreading. In summary, this study provides a method for immobilization of biomolecules on PCL films to be used in peripheral nerve repair, as demonstrated by the enhanced response of Schwann cells.
Resumo:
SIMP (source of immunodominant MHC-associated peptides) plays a key rote in N-linked glycosylation with the active site of oligosaccharyltransferase, being the source of MHC-peptides in the MHC I presentation pathway. In the present study, the SIMP gene has been cloned from grass carp Ctenopharyngodon idella by rapid amplification of cDNA ends (RACE). The full length of the cDNA sequence is 4384 bp, including a 1117 bp 5' UTR (untranslated region), a 2418 bp open reading frame, and a 849 bp 3' UTR. The deduced amino acids of the grass carp SIMP (gcSIMP) are a highly conserved protein with a STT3 domain and 11 transmembrane regions. The gcSIMP spans over more than 24,212 bp in length, containing 16 exons and 15 introns. Most encoding exons, except the first and the 15th, have the same length as those in human and mouse. The gcSIMP promoter contains many putative transcription factor binding sites, such as Oct-1, GCN4, YY1, Sp1, Palpha, TBP, GATA-1, C/EBP beta, and five C/EBP alpha binding sites. The mRNA expression of gcSIMP in different organs was examined by real-time PCR. The gcSIMP was distributed in all the organs examined, with the highest level in brain, followed by the level in the heart, liver, gill, trunk kidney, muscle, head kidney, thymus, and the lowest level in spleen. Furthermore, the recombinant gcSIMP has been constructed successfully and expressed in Escherichia coli by using pQE-40 vector, and the polyclonal antibody for rabbit has been successfully obtained, which was verified to be specific. Identification of gcSIMP will help to explore the function in fish innate immunity. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Many B cell epitopes within p24 of human immunodeficiency virus type 1 (HIV-1) were identified, while most of them were determined by using murine monoclonal antibodies reacting with overlapping peptides of p24. Therefore these epitopes may not represent the actual epitopes recognized by the HIV-1 infected individuals. In the present study, immune responses of 67 HIV-1 positive sera from Yunnan Province, China to five peptides on p24 of HIV-1 and one of HIV-2 were analyzed. All of 67 sera did not recognize peptide GA-12 on HIV-1 and peptide AG-23 on HIV-2, which indicated that GA-12 was not human B cell epitope and AG-23 did not cross-react with HIV-1 positive serum. Except 13 sera (19.4%), all remaining sera did not recognize peptides NI-15, DR-16, DC-22 and PS-18, which indicated that these four peptides represented B cell linear epitopes of HIV-1 p24 in some HIV-1 infected individuals but not the immuno-dominant epitopes in most individuals. Cellular & Molecular Immunology. 2005;2(4):289-293.
Resumo:
Pressurized capillary electrochromatography (pCEC) was coupled with electrospray ionization mass spectrometry (ESI-MS) using a coaxial sheath liquid interface. It was used for separation and analysis of peptides and proteins. The effects of organic modifier and applied voltage on separation were investigated, and the effects of pH value of the mobile phase and the concentration of the electrolyte on ESI-MS signal were investigated. The resolution and detection sensitivity with different separation methods (pCEC, capillary high-performance liquid chromatography) coupled on-line with mass spectrometry were compared for the separation of a peptide mixture. To evaluate the feasibility and reliability of the experimental setup of the system, tryptic digests of cytochrome c and modified protein as real samples were analyzed by using pCEC-ESI-MS.
Resumo:
The mixed mode of reversed phase (RP) and strong canon-exchange (SCX) capillary electrochromatography (CEC) based on a monolithic capillary column has been developed. The capillary monolithic column was prepared by in situ copolymerization of 2-(sulfooxy)ethyl methacrylate (SEMA) and ethylene dimethacrylate (EDMA) in the presence of porogens. The sulfate group provided by the monomer SEMA on the monolithic bed is used for the generation of the electroosmotic flow (EOF) from the anode to the cathode, but at the same time serves as a SCX stationary phase. A mixed-mode (RP/SCX) mechanism for separation of peptides was observed in the monolithic column, comprising hydrophobic and electrostatic interaction as well as electrophoretic migration at a low pH value of mobile phase. A column efficiency of more than 280000 plates/m for the unretained compound has been obtained on the prepared monoliths. The relative standard deviations observed for to and retention factors of peptides were about 0.32% and less than 0.71% for ten consecutive runs, respectively. Effects of mobile phase compositions on the EOF of the monolithic column and on the separation of peptides were investigated. The selectivity on separation of peptides in the monolithic capillary column could be easily manipulated by varying the mobile phase composition.
Resumo:
A new method for the sensitive determination of amino acids and peptides using the tagging reagent 2-(9-carbazole)-ethyl chloroformate (CEOC) with fluorescence (FL) detection has been developed. Identification of derivatives was carried out by liquid chromotography mass spectrometry. The chromophore in the 2-(9-fluorenyl)-ethyl chloroformate (FMOC) reagent was replaced by carbazole, which resulted in a sensitive fluorescence lerivatizing agent CEOC. CEOC can easily and quickly label peptides and amino acids. Derivatives are stable enough to be efficiently analyzed by high-performance liquid chromatography. Studies on derivatization demonstrate excellent derivative yields over the pH range 8.8-10.0. Maximal yields close to 100% are observed with three- to fourfold molar reagent excess. Derivatives exhibit strong fluorescence and allow direct injection of the reaction mixture with no significant disturbance from the major fluorescent reagent degradation by-products, such as 2(9-carbazole)-ethanol and bis-(2-(9-carbazole)-ethyl) carbonate. In addition, the detection responses for CEOC derivatives are compared to those obtained with FMOC. The ratios AC(CEOC)/AC(FMOC) = 1.00-1.82 for fluorescence (FL) response and AC'(CEOC)/AC'(FMOC) = 1.00-1.21 for ultraviolet (UV) response are observed (here, AC and AC' are, respectively, FL and UV F response). Separation of the derivatized peptides and amino acids has been optimized on a Hypersil BDS C18 column. Excellent linear responses are observed. This method was used successfully to analyze protein hydrolysates from wool and from direct-derivatized beer. (C) 2003 Elsevier Science (USA). All rights reserved.
Resumo:
A pressurized electrochromatography (pCEC) instrument with gradient capability was used in this work for separation of peptides. Three separation modes, namely, pCEC, high-performance liquid chromatography and capillary electrophoresis can be carried out with the instrument. In pCEC mode, the mobile phase is driven by both electroosmotic flow and pressurized flow, facilitating fine-tuning in selectivity of neutral and charged species. A continuous gradient elution can be carried out conveniently on this instrument, which demonstrates that it is more powerful than isocratic pCEC for separation of complicated samples. The effects of applied voltage, supplementary pressure and ion-pairing agents on separation of peptides in gradient pCEC were investigated. The effects of flow-rate of the pump and the volume of the mixer on resolution were also evaluated. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
A pressurized capillary electrochromatography (pCEC) instrument with solvent gradient capability has been used for the separation of a peptide mixture. Retention mechanism and selectivity of the peptides were studied by pCEC using a strong cation exchange (SCX) column. The effects of applied voltage, supplementary pressure, organic modifier concentration, ionic strength,, and pH value on pCEC separation were investigated. It was found that the retention mechanism of the peptides in this system is based on a mixed mode of hydrophilic interaction, strong cation exchange, and electrophoresis. Compared with the separation results obtained by reverse phase pCEC and capillary electrophoresis (CE), this mixed-mode pCEC is more powerful for the separation of hydrophilic peptides with similar charge-to-mass ratio.
Resumo:
A mode of capillary electrochromatography for separation of ionic compounds driven by electrophoretic mobility on a neutrally hydrophobic monolithic column was developed. The monolithic column was prepared from the in situ copolymerization of lauryl methacrylate and ethylene dimethacrylate to form a C-12 hydrophobic stationary phase. It was found that EOF in this hydrophobic monolithic column was very poor, even the pH value of mobile phase at 8.0. The peptides at acidic buffer were separated on the basis of their differences in electrophoretic mobility and hydrophobic interaction with the stationary phase; therefore, different separation selectivity can be obtained in CEC from that in capillary zone electrophoresis (CZE). Separation of peptides has been realized with high column efficiency (up to 150 000 plates/meter) and good reproducibility (migration time with RSD < 0.5%), and all of the peptides, including some basic peptides, showed good peak symmetry. Effects of the mobile phase compositions on the retention of peptides at low pH have been investigated in a hydrophobic capillary monolithic column. The significant difference in selectivity of peptides in CZE and CEC has been observed. Some peptide isomers that cannot be separated by CZE have been successfully separated on the capillary monolithic column in this mode with the same buffer used.