996 resultados para Condensed Matter Physics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper derives a general procedure for the numerical solution of the Lindblad equations that govern the coherences arising from multicoloured light interacting with a multilevel system. A systematic approach to finding the conservative and dissipative terms is derived and applied to the laser cooling of p-block elements. An improved numerical method is developed to solve the time-dependent master equation and results are presented for transient cooling processes. The method is significantly more robust, efficient and accurate than the standard method and can be applied to a broad range of atomic and molecular systems. Radiation pressure forces and the formation of dynamic dark states are studied in the gallium isotope 66Ga.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Poly(epsilon-caprolactone) (PCL) has many favourable attributes for tissue engineering scaffold applications. A major drawback, however, is its slow degradation rate, typically greater than 3 years. In this study PCL was melt blended with a small percentage of poly(aspartic acid-co-lactide) (PAL) and the degradation behaviour was evaluated in phosphate buffer solution (PBS) at 37 degrees C. The addition of PAL was found to significantly enhance the degradation profile of PCL. Subsequent degradation behaviour was investigated in terms of the polymer's mechanical properties, Molecular weight (M-w), mass changes and thermal characteristics. The results indicate that the addition of PAL accelerates the degradation of PCL, with 20% mass loss recorded after just 7 months in vitro for samples containing 8 wt% PAL. The corresponding pure PCL samples exhibited no mass loss over the same time period. In vitro assessment of PCL and PCL/PAL composites in tissue Culture medium in the absence of cells revealed stable pH readings with time. SEM studies of cell/biomaterial interactions demonstrated biocompatibility of C3H10T1/2 cells with PCL and PCL/PAL composites at all concentrations of PAL additive. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A microfluidic glass chip system incorporating a quartz crystal microbalance (QCM) to measure the square root of the viscosity-density product of room temperature ionic liquids (RTILs) is presented. The QCM covers a central recess on a glass chip, with a seal formed by tightly clamping from above outside the sensing region. The change in resonant frequency of the QCM allows for the determination of the square root viscosity-density product of RTILs to a limit of similar to 10 kg m(-2) s(-0.5). This method has reduced the sample size needed for characterization from 1.5 ml to only 30 mu l and allows the measurement to be made in an enclosed system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemistry of nicotinamide adenine dinucleotide (NADH) in its reduced form was examined in two room-temperature ionic liquids (RTILs): 1-ethyl-3-methylimidazolium bis-(trifluoromethylsulfonyl)imide ([C(2)mim][NTf2]) and 1-butyl-3-methylimidazolium hexafluorophos-phate ([C(4)mim][PF6]). NADH oxidation has previously been studied in aqueous solution where it follows the pathway: one-electron oxidation to the NADH(center dot+) radical cation, deprotonation to produce the neutral NAD(center dot) radical, then oxidation to the NAD(+) cation. The electrochemistry of NADH was examined in [C(2)mim][NTf2] and [C(4)mim][PF6] at the bare Pt electrode (10 mu m diameter): In [C(2)mim][NTf2], no oxidation was observed; in [C(4)mim][PF6], an oxidative signal was observed, which likely followed the pathway described above, where upon formation of the NADH(center dot+) radical cation, the [PF6](-) anion (unlike the [NTf2](-) anion) reacts with the proton to form HPF6, which decomposes. This demonstrates the tunability of RTILs, whereby the choice of one anion in an RTIL over another can promote a reaction. Poly(vinylferrocene) (PVF) was studied as a mediator for the NADH detection in both RTILs to attempt to lower the potential of NADH detection. The Pt electrode was modified with PVF, and the oxidation of PVF to PVF+ was observed in [C(2)mim][NTf2] and [C(4)mim][PF6], but no mediation of the NADH oxidation was observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zinc oxide nanoparticles have been synthesized by microwave decomposition of zinc acetate precursor using an ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethylsulfonyl) imide, [bmim][NTf2] as a green solvent. The structure and morphology of ZnO nanoparticles have been characterized using X-ray diffraction and transmission electron microscopy. The ZnO nanofluids have been prepared by dispersing ZnO nanoparticles in glycerol as a base fluid in the presence of ammonium citrate as a dispersant. The antibacterial activity of suspensions of ZnO nanofluids against (E. coli) has been evaluated by estimating the reduction ratio of the bacteria treated with ZnO. Survival ratio of bacteria decreases with increasing the concentrations of ZnO nanofluids and time. The results show that an increase in the concentrations of ZnO nanofluids produces strong antibacterial activity toward E. coli. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this article, we present position indication functionality as obtained by using a retrodirective array, thereby allowing location information extraction of the position of the remote transmitter with which the retrodirective array is cooperating. This is carried out using straightforward circuitry with no requirement for complex angle of arrival algorithms, thereby giving a result in real time enabling tracking of fast moving transmitters. We show using a 10 x element retrodirective array, operating at 2.4 GHz that accuracies of far-field angle of arrival of within +/- 1 degrees over the arrays +/- 30 degrees azimuth field of view are possible. While in the near-field for angles of arrival of +/- 10 degrees it is possible to extract the position of a dipole source down to a resolution of 032 lambda. (C) 2010 Wiley Periodicals, Inc. Microwave Opt Technol Lett 52: 1031-1034, 2010; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.25097

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we provide experimental evidence to show that enhanced bit error rate (BER) performance is possible using a retrodirective array operating in a dynamically varying multipath environment. The operation of such a system will be compared to that obtained by a conventional nonretrodirective array. The ability of the array to recover amplitude shift keyed encoded data transmitted from a remote location whose position is not known a priori is described. In addition, its ability to retransmit data inserted at the retrodirective array back to a spatially remote beacon location whose position is also not known beforehand is also demonstrated. Comparison with an equivalent conventional fixed beam antenna array utilizing an identical radiating aperture arrangement to that of the retrodirective array are given. These show that the retrodirective array can effectively exploit the presence of time varying multipath in order to give significant reductions in BER over what can be otherwise achieved. Additionally, the retrodirective system is shown to be able to deliver low BER regardless of whether line of sight is present or absent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental results are presented for the focusing capability of an active phase conjugating lens for a single and a dipole source pair and these are compared with predictions. In addition for a single source we illustrate the ability of the lens to project a null at the lens focus instead of a peak. A scheme is also presented such that when a source or pair of sources is imaged through an identical pair of passive scatterers located symmetrically about the lens that imaging with sub-wavelength resolution is possible. The rationale for the operation of the lens and aberrations observed due to its finite array size is discussed and is supported throughout by means of numerical simulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigate the situation where there are obstructing elements present in the near field of a retrodirective array. We describe three scattering cases, (1) by an array of straight wires, (2) by low loss medium density fibre board partially obscuring the array, and (3) by concrete blocks, totally and then partially obscuring the array. For all scenarios retrodirective action was shown to be able to provide various degrees of automatic compensation for loss in gain relative to that which would have occurred for a conventional (non-retrodirective) array in the presence of the same scattering screens. Gain improvements of up to 10 dB were observed when the retrodirective array was used. In addition we show how the induced variation of received and re-transmited amplitudes across the array, caused by the scattering screens, is the principle mechanism causing deterioration of the retrodirective arrays monostatic response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents a cascaded arrangement comprising a double-layer frequency selective surface circularly polarizing (CPFSS) and a second screen that can be switched between artificial magnetic conduction (AMC) or perfect electric conducting. (PEC) states. The CPFSS consists of two stacked aluminium sheets patterned with periodic split ring structures While the AMC is a PCB sheet patterned with metallic squares interconnected by links By either open or short circuiting these links it is shown that the cascade of screens can be made to twist, or not to twist, an incident 45 degrees linearly polirized signal through 90 degrees upon reflection from the assembly The system was designed and optimized using CST software and predictions were validated experimentally and measured monostatic reflection loss results (C) 2010 Wiley Periodicals, Inc Microwave Opt Technol Lett 52 577-580, 2010. Published online in Wiley InterScience (www.interscience.wiley.com) DOI 10.1002/mop.24979

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An architecture to simultaneously affect both amplitude and phase control from a reflectarray element using an impedance transformation unit is demonstrated. It is shown that a wide range of control is possible from a single element, removing the conventional necessity for variable sized elements across an array in order to form a desired reflectarray far-field pattern. Parallel plate waveguide measurements for a 2.2 GHz prototype element validate the phase and amplitude variation available from the element. It is demonstrated that there is sufficient control of the element's reflection response to allow Dolph-Tschebyscheff weighting coefficients for major-lobe to side-lobe ratios of up to 36 dB to be implemented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A single layer, frequency selective surface based, sub-millimeter wave transmission polarizer is presented that converts incident slant linear 45° polarization into circular polarization upon transmission. The polarization convertor consists of a 30 mm diameter 10 thick silicon reinforced metalized screen containing 2700 resonator cells and perforated with nested split ring slot apertures. The screen was designed and optimized using CST Microwave Studio and predictions were validated experimentally by transmission measurements over the 250-365 GHz frequency range. This frequency range is used for remote environmental monitoring and 325 GHz represents a molecular emission line for H2O. The results obtained show good agreement between measured and modeled predictions. The measured 3 dB axial ratio bandwidth was 11.75%, measured minimum Axial Ratio was 0.19 dB and the measured insertion loss of the single layer screen was 3.38 dB