875 resultados para Classification, Degeneration, Lumbar intervertebral disc, Reliability, Validity


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This report outlines the development, validity, and reliability of Part A of the OARS Multidimensional Functional Assessment Questionnaire. Part A permits assessment of individuals' functioning on each of five dimensions (social, economic, mental health, physical health and self-care capacity), the detailed information in each area being summarized on a 6-point rating scale by a rater. Content and consensual validity were ensured by the manner of construction. Information on criterion validity was obtained for all dimensions except social. The criterion used and their associated Kendall's Tau values were: an objective economic scale (.62); ratings based on personal interviews by geropsychiatrists (.60); physician's associates (.82); and physical therapists (.89). For 11 geographically dispersed raters from research and clinic settings, intraclass correlational coefficients, based on 30 subjects, ranged from .66 on physical health to .87 in self-care capacity; 74% of the ratings were in complete agreement, 24% differed by one point.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the training of healthcare professionals, one of the advantages of communication training with simulated patients (SPs) is the SP's ability to provide direct feedback to students after a simulated clinical encounter. The quality of SP feedback must be monitored, especially because it is well known that feedback can have a profound effect on student performance. Due to the current lack of valid and reliable instruments to assess the quality of SP feedback, our study examined the validity and reliability of one potential instrument, the 'modified Quality of Simulated Patient Feedback Form' (mQSF). Methods Content validity of the mQSF was assessed by inviting experts in the area of simulated clinical encounters to rate the importance of the mQSF items. Moreover, generalizability theory was used to examine the reliability of the mQSF. Our data came from videotapes of clinical encounters between six simulated patients and six students and the ensuing feedback from the SPs to the students. Ten faculty members judged the SP feedback according to the items on the mQSF. Three weeks later, this procedure was repeated with the same faculty members and recordings. Results All but two items of the mQSF received importance ratings of > 2.5 on a four-point rating scale. A generalizability coefficient of 0.77 was established with two judges observing one encounter. Conclusions The findings for content validity and reliability with two judges suggest that the mQSF is a valid and reliable instrument to assess the quality of feedback provided by simulated patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To determine the association between the 3-dimensional (3-D) motion pattern of the caudal lumbar and lumbosacral portions of the canine vertebral column and the morphology of vertebrae, facet joints, and intervertebral disks. SAMPLE POPULATION: Vertebral columns of 9 German Shepherd Dogs and 16 dogs of other breeds with similar body weights and body conditions. PROCEDURE: Different morphometric parameters of the vertebral column were assessed by computed tomography (CT) and magnetic resonance imaging. Anatomic conformation and the 3-D motion pattern were compared, and correlation coefficients were calculated. RESULTS: Total range of motion for flexion and extension was mainly associated with the facet joint angle, the facet joint angle difference between levels of the vertebral column in the transverse plane on CT images, disk height, and lever arm length. CONCLUSIONS AND CLINICAL RELEVANCE: Motion is a complex process that is influenced by the entire 3-D conformation of the lumbar portion of the vertebral column. In vivo dynamic measurements of the 3-D motion pattern of the lumbar and lumbosacral portions of the vertebral column will be necessary to further assess biomechanics that could lead to disk degeneration in dogs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

STUDY DESIGN: The structural integrity of the nucleus pulposus (NP) of intervertebral discs was targeted by enzyme-specific degradations to correlate their effects to the magnetic resonance (MR) signal. OBJECTIVE: To develop quantitative MR imaging as an accurate and noninvasive diagnostic tool to better understand and treat disc degeneration. SUMMARY OF BACKGROUND DATA: Quantitative MR analysis has been previously shown to reflect not only the disc matrix composition, but also the structural integrity of the disc matrix. Further work is required to identify the contribution of the structural integrity versus the matrix composition to the MR signal. METHODS: The bovine coccygeal NPs were injected with either enzyme or buffer, incubated at 37 degrees C as static, unloaded and closed 3-disc segments, and analyzed by a 1.5-Tesla MR scanner to measure MR parameters. RESULTS: Collagenase degradation of the NP significantly decreased the relaxation times, slightly decreased the magnetization transfer ratio, and slightly increased the apparent diffusion coefficient. Targeting the proteoglycan and/or hyaluronan integrity by trypsin and hyaluronidase did not significantly affect the MR parameters, except for an increase in the apparent diffusion coefficient of the disc after trypsin treatment. CONCLUSIONS: Our results demonstrate that changes in the structural integrity of matrix proteins can be assessed by quantitative MR.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the German version of the Short Understanding of Substance Abuse Scale (SUSS) [Humphreys et al.: Psychol Addict Behav 1996;10:38-44], the Verstandnis von Storungen durch Substanzkonsum (VSS), and evaluates its psychometric properties. The VSS assesses clinicians' beliefs about the nature and treatment of substance use disorders, particularly their endorsement of psychosocial and disease orientation. The VSS was administered to 160 treatment staff members at 12 substance use disorder treatment programs in the German-speaking part of Switzerland. Because the confirmatory factor analysis of the VSS did not completely replicate the factorial structure of the SUSS, an exploratory factor analysis was undertaken. This analysis identified two factors: the Psychosocial model factor and a slightly different Disease model factor. The VSS Disease and Psychosocial subscales showed convergent and discriminant validity, as well as sufficient reliability.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To determine stiffness and load-displacement curves as a biomechanical response to applied torsion and shear forces in cadaveric canine lumbar and lumbosacral specimens. STUDY DESIGN: Biomechanical study. ANIMALS: Caudal lumbar and lumbosacral functional spine units (FSU) of nonchondrodystrophic large-breed dogs (n=31) with radiographically normal spines. METHODS: FSU from dogs without musculoskeletal disease were tested in torsion in a custom-built spine loading simulator with 6 degrees of freedom, which uses orthogonally mounted electric motors to apply pure axial rotation. For shear tests, specimens were mounted to a custom-made shear-testing device, driven by a servo hydraulic testing machine. Load-displacement curves were recorded for torsion and shear. RESULTS: Left and right torsion stiffness was not different within each FSU level; however, torsional stiffness of L7-S1 was significantly smaller compared with lumbar FSU (L4-5-L6-7). Ventral/dorsal stiffness was significantly different from lateral stiffness within an individual FSU level for L5-6, L6-7, and L7-S1 but not for L4-5. When the data from 4 tested shear directions from the same specimen were pooled, level L5-6 was significantly stiffer than L7-S1. CONCLUSIONS: Increased range of motion of the lumbosacral joint is reflected by an overall decreased shear and rotational stiffness at the lumbosacral FSU. CLINICAL RELEVANCE: Data from dogs with disc degeneration have to be collected, analyzed, and compared with results from our chondrodystrophic large-breed dogs with radiographically normal spines.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This case report describes the magnetic resonance imaging (MRI) findings and the treatment of a far lateral extrusion of disc material at the sixth and seventh lumbar vertebrae (L6-L7) in a five-year-old male Alpine Dachsbracke dog referred to our hospital for investigation of the complaint of a one week progressive lameness in the left pelvic limb and poorly localized back pain. An extra-foraminal left lateral disc herniation impinging on the sixth lumbar nerve root was diagnosed by MRI examinations. Due to the far lateral position of the extruded disc material on MRI, surgical opening of the spinal canal was not necessary. Removal of the herniated soft disc material impinging on the L6 nerve root, and fenestration of the L6-L7 disc was performed laterally. To the author's knowledge 'far-lateral' disc herniation beyond the neuroforamen without any spinal canal contact has not been described in dogs until now. A complete recovery with no evidence of pain was achieved only after a couple of weeks after surgery. We acknowledge that it is possible that other pathological mechanisms may have contributed to clinical signs and to a delayed recovery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nucleus pulposus (NP) regeneration by the application of injectable cell-embedded hydrogels is an appealing approach for tissue engineering. We investigated a thermo-reversible hydrogel (TR-HG), based on a modified polysaccharide with a thermo-reversible polyamide [poly(N-isopropylacrylamide), pNIPAM], which is made to behave as a liquid at room temperature and hardens at > 32 °C. In order to test the hydrogel, a papain-induced bovine caudal disc degeneration model (PDDM), creating a cavity in the NP, was employed. Human mesenchymal stem cells (hMSCs) or autologous bovine NP cells (bNPCs) were seeded in TR-HG; hMSCs were additionally preconditioned with rhGDF-5 for 7 days. Then, TR-HG was reversed to a fluid and the cell suspension injected into the PDDM and kept under static loading for 7 days. Experimental design was: (D1) fresh disc control + PBS injection; (D2) PDDM + PBS injection; (D3) PDDM + TR-HG (material control); (D4) PDDM + TR-HG + bNPCs; (D5) PDDM + TR-HG + hMSCs. Magnetic resonance imaging performed before and after loading, on days 9 and 16, allowed imaging of the hydrogel-filled PDDM and assessment of disc height and volume changes. In gel-injected discs the NP region showed a major drop in volume and disc height during culture under static load. The RT–PCR results of injected hMSCs showed significant upregulation of ACAN, COL2A1, VCAN and SOX9 during culture in the disc cavity, whereas the gene expression profile of NP cells remained unchanged. The cell viability of injected cells (NPCs or hMSCs) was maintained at over 86% in 3D culture and dropped to ~72% after organ culture. Our results underline the need for load-bearing hydrogels that are also cyto-compatible.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The design of Virtual Patients (VPs) is essential. So far there are no validated evaluation instruments for VP design published. Summary of work: We examined three sources of validity evidence of an instrument to be filled out by students aimed at measuring the quality of VPs with a special emphasis on fostering clinical reasoning: (1) Content was examined based on theory of clinical reasoning and an international VP expert team. (2) Response process was explored in think aloud pilot studies with students and content analysis of free text questions accompanying each item of the instrument. (3) Internal structure was assessed by confirmatory factor analysis (CFA) using 2547 student evaluations and reliability was examined utilizing generalizability analysis. Summary of results: Content analysis was supported by theory underlying Gruppen and Frohna’s clinical reasoning model on which the instrument is based and an international VP expert team. The pilot study and analysis of free text comments supported the validity of the instrument. The CFA indicated that a three factor model comprising 6 items showed a good fit with the data. Alpha coefficients per factor were 0,74 - 0,82. The findings of the generalizability studies indicated that 40-200 student responses are needed in order to obtain reliable data on one VP. Conclusions: The described instrument has the potential to provide faculty with reliable and valid information about VP design. Take-home messages: We present a short instrument which can be of help in evaluating the design of VPs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A patient classification system was developed integrating a patient acuity instrument with a computerized nursing distribution method based on a linear programming model. The system was designed for real-time measurement of patient acuity (workload) and allocation of nursing personnel to optimize the utilization of resources.^ The acuity instrument was a prototype tool with eight categories of patients defined by patient severity and nursing intensity parameters. From this tool, the demand for nursing care was defined in patient points with one point equal to one hour of RN time. Validity and reliability of the instrument was determined as follows: (1) Content validity by a panel of expert nurses; (2) predictive validity through a paired t-test analysis of preshift and postshift categorization of patients; (3) initial reliability by a one month pilot of the instrument in a practice setting; and (4) interrater reliability by the Kappa statistic.^ The nursing distribution system was a linear programming model using a branch and bound technique for obtaining integer solutions. The objective function was to minimize the total number of nursing personnel used by optimally assigning the staff to meet the acuity needs of the units. A penalty weight was used as a coefficient of the objective function variables to define priorities for allocation of staff.^ The demand constraints were requirements to meet the total acuity points needed for each unit and to have a minimum number of RNs on each unit. Supply constraints were: (1) total availability of each type of staff and the value of that staff member (value was determined relative to that type of staff's ability to perform the job function of an RN (i.e., value for eight hours RN = 8 points, LVN = 6 points); (2) number of personnel available for floating between units.^ The capability of the model to assign staff quantitatively and qualitatively equal to the manual method was established by a thirty day comparison. Sensitivity testing demonstrated appropriate adjustment of the optimal solution to changes in penalty coefficients in the objective function and to acuity totals in the demand constraints.^ Further investigation of the model documented: correct adjustment of assignments in response to staff value changes; and cost minimization by an addition of a dollar coefficient to the objective function. ^