938 resultados para Building demand estimation model


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Li-ion batteries have been widely used in electric vehicles, and battery internal state estimation plays an important role in the battery management system. However, it is technically challenging, in particular, for the estimation of the battery internal temperature and state-ofcharge (SOC), which are two key state variables affecting the battery performance. In this paper, a novel method is proposed for realtime simultaneous estimation of these two internal states, thus leading to a significantly improved battery model for realtime SOC estimation. To achieve this, a simplified battery thermoelectric model is firstly built, which couples a thermal submodel and an electrical submodel. The interactions between the battery thermal and electrical behaviours are captured, thus offering a comprehensive description of the battery thermal and electrical behaviour. To achieve more accurate internal state estimations, the model is trained by the simulation error minimization method, and model parameters are optimized by a hybrid optimization method combining a meta-heuristic algorithm and the least square approach. Further, timevarying model parameters under different heat dissipation conditions are considered, and a joint extended Kalman filter is used to simultaneously estimate both the battery internal states and time-varying model parameters in realtime. Experimental results based on the testing data of LiFePO4 batteries confirm the efficacy of the proposed method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The viscosity of ionic liquids (ILs) has been modeled as a function of temperature and at atmospheric pressure using a new method based on the UNIFAC–VISCO method. This model extends the calculations previously reported by our group (see Zhao et al. J. Chem. Eng. Data 2016, 61, 2160–2169) which used 154 experimental viscosity data points of 25 ionic liquids for regression of a set of binary interaction parameters and ion Vogel–Fulcher–Tammann (VFT) parameters. Discrepancies in the experimental data of the same IL affect the quality of the correlation and thus the development of the predictive method. In this work, mathematical gnostics was used to analyze the experimental data from different sources and recommend one set of reliable data for each IL. These recommended data (totally 819 data points) for 70 ILs were correlated using this model to obtain an extended set of binary interaction parameters and ion VFT parameters, with a regression accuracy of 1.4%. In addition, 966 experimental viscosity data points for 11 binary mixtures of ILs were collected from literature to establish this model. All the binary data consist of 128 training data points used for the optimization of binary interaction parameters and 838 test data points used for the comparison of the pure evaluated values. The relative average absolute deviation (RAAD) for training and test is 2.9% and 3.9%, respectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To get a better insight into the radiological features of industrial by-products that can be reused in building materials a review of the reported scientific data can be very useful. The current study is based on the continuously growing database of the By-BM (H2020-MSCA-IF-2015) project (By-products for Building Materials). Currently, the By-BM database contains individual data of about 431 by-products and 1095 building and raw materials. It was found that in case of the building materials the natural radionuclide content varied widely (Ra-226: <DL-27851 Bq/kg; Th-232: <DL-906 Bq/kg, K-40: <DL-17922 Bq/kg), more so than for the by-products (Ra-226: 7-3152 Bq/kg; Th-232: <DL-1350 Bq/kg, K-40: <DL-3001 Bq/kg). The average Ra-226, Th-232 and K-40 contents of the reported by-products were respectively 2.52, 2.35 and 0.39 times higher than the building materials. The gamma exposure of bulk building products was calculated according to IAEA Specific Safety Guide No. SSG-32 and the European Commission Radiation Protection 112 based I-index (EU BSS). It was found that in most cases the I-index without density consideration provides a significant overestimation in excess effective dose.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mathematical models are increasingly used in environmental science thus increasing the importance of uncertainty and sensitivity analyses. In the present study, an iterative parameter estimation and identifiability analysis methodology is applied to an atmospheric model – the Operational Street Pollution Model (OSPMr). To assess the predictive validity of the model, the data is split into an estimation and a prediction data set using two data splitting approaches and data preparation techniques (clustering and outlier detection) are analysed. The sensitivity analysis, being part of the identifiability analysis, showed that some model parameters were significantly more sensitive than others. The application of the determined optimal parameter values was shown to succesfully equilibrate the model biases among the individual streets and species. It was as well shown that the frequentist approach applied for the uncertainty calculations underestimated the parameter uncertainties. The model parameter uncertainty was qualitatively assessed to be significant, and reduction strategies were identified.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Energy auditing can be an important contribution for identification and assessment of energy conservation measures (ECMs) in buildings. Numerous tools and software have been developed, with varying degree of precision and complexity and different areas of use.   This paper evaluates PHPP as a versatile, easy-to-use energy auditing tool and gives examples of how it has been compared to a dynamic simulation tool, within the EU-project iNSPiRe. PHPP is a monthly balance energy calculation tool based on EN13790. It is intended for assisting the design of Passive Houses and energy renovation projects and as guidance in the choice of appropriate ECMs.   PHPP was compared against the transient simulation software TRNSYS for a single family house and a multi-family house. It should be mentioned that dynamic building simulations might strongly depend on the model assumptions and simplifications compared to reality, such as ideal heating or real heat emission system. Setting common boundary conditions for both PHPP and TRNSYS, the ideal heating and cooling loads and demands were compared on monthly and annual basis for seven European locations and buildings with different floor area, S/V ratio, U-values and glazed area of the external walls.   The results show that PHPP can be used to assess the heating demand of single-zone buildings and the reduction of heating demand with ECMs with good precision. The estimation of cooling demand is also acceptable if an appropriate shading factor is applied in PHPP. In general, PHPP intentionally overestimates heating and cooling loads, to be on the safe side for system sizing. Overall, the agreement with TRNSYS is better in cases with higher quality of the envelope as in cold climates and for good energy standards. As an energy auditing tool intended for pre-design it is a good, versatile and easy-to-use alternative to more complex simulation tools.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Knowledge on human behaviour in emergency is crucial to increase the safety of buildings and transportation systems. Decision making during evacuations implies different choices, of which one of the most important concerns the escape route. The choice of a route may involve local decisions between alternative exits from an enclosed environment. This work investigates the influence of environmental (presence of smoke, emergency lighting and distance of exit) and social factors (interaction with evacuees close to the exits and with those near the decision-maker) on local exit choice. This goal is pursued using an online stated preference survey carried out making use of non-immersive virtual reality. A sample of 1,503 participants is obtained and a Mixed Logit Model is calibrated using these data. The model shows that presence of smoke, emergency lighting, distance of exit, number of evacuees near the exits and the decision-maker, and flow of evacuees through the exits significantly affect local exit choice. Moreover, the model points out that decision making is affected by a high degree of behavioural uncertainty. Our findings support the improvement of evacuation models and the accuracy of their results, which can assist in designing and managing building and transportation systems. The main contribution of this work is to enrich the understanding of how local exit choices are made and how behavioural uncertainty affects these choices.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

I study how a larger party within a supply chain could use its superior knowledge about its partner, who is considered to be financially constrained, to help its partner gain access to cheap finance. In particular, I consider two scenarios: (i) Retailer intermediation in supplier finance and (ii) The Effectiveness of Supplier Buy Back Finance. In the fist chapter, I study how a large buyer could help small suppliers obtain financing for their operations. Especially in developing economies, traditional financing methods can be very costly or unavailable to such suppliers. In order to reduce channel costs, in recent years large buyers started to implement their own financing methods that intermediate between suppliers and financing institutions. In this paper, I analyze the role and efficiency of buyer intermediation in supplier financing. Building a game-theoretical model, I show that buyer intermediated financing can significantly improve supply chain performance. Using data from a large Chinese online retailer and through structural regression estimation based on the theoretical analysis, I demonstrate that buyer intermediation induces lower interest rates and wholesale prices, increases order quantities, and boosts supplier borrowing. The analysis also shows that the retailer systematically overestimates the consumer demand. Based on counterfactual analysis, I predict that the implementation of buyer intermediated financing for the online retailer in 2013 improved channel profits by 18.3%, yielding more than $68M projected savings. In the second chapter, I study a novel buy-back financing scheme employed by large manufacturers in some emerging markets. A large manufacturer can secure financing for its budget-constrained downstream partners by assuming a part of the risk for their inventory by committing to buy back some unsold units. Buy back commitment could help a small downstream party secure a bank loan and further induce a higher order quantity through better allocation of risk in the supply chain. However, such a commitment may undermine the supply chain performance as it imposes extra costs on the supplier incurred by the return of large or costly-to-handle items. I first theoretically analyze the buy-back financing contract employed by a leading Chinese automative manufacturer and some variants of this contracting scheme. In order to measure the effectiveness of buy-back financing contracts, I utilize contract and sales data from the company and structurally estimate the theoretical model. Through counterfactual analysis, I study the efficiency of various buy-back financing schemes and compare them to traditional financing methods. I find that buy-back contract agreements can improve channel efficiency significantly compared to simple contracts with no buy-back, whether the downstream retailer can secure financing on its own or not.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tourist accommodation expenditure is a widely investigated topic as it represents a major contribution to the total tourist expenditure. The identification of the determinant factors is commonly based on supply-driven applications while little research has been made on important travel characteristics. This paper proposes a demand-driven analysis of tourist accommodation price by focusing on data generated from room bookings. The investigation focuses on modeling the relationship between key travel characteristics and the price paid to book the accommodation. To accommodate the distributional characteristics of the expenditure variable, the analysis is based on the estimation of a quantile regression model. The findings support the econometric approach used and enable the elaboration of relevant managerial implications.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Estimating un-measurable states is an important component for onboard diagnostics (OBD) and control strategy development in diesel exhaust aftertreatment systems. This research focuses on the development of an Extended Kalman Filter (EKF) based state estimator for two of the main components in a diesel engine aftertreatment system: the Diesel Oxidation Catalyst (DOC) and the Selective Catalytic Reduction (SCR) catalyst. One of the key areas of interest is the performance of these estimators when the catalyzed particulate filter (CPF) is being actively regenerated. In this study, model reduction techniques were developed and used to develop reduced order models from the 1D models used to simulate the DOC and SCR. As a result of order reduction, the number of states in the estimator is reduced from 12 to 1 per element for the DOC and 12 to 2 per element for the SCR. The reduced order models were simulated on the experimental data and compared to the high fidelity model and the experimental data. The results show that the effect of eliminating the heat transfer and mass transfer coefficients are not significant on the performance of the reduced order models. This is shown by an insignificant change in the kinetic parameters between the reduced order and 1D model for simulating the experimental data. An EKF based estimator to estimate the internal states of the DOC and SCR was developed. The DOC and SCR estimators were simulated on the experimental data to show that the estimator provides improved estimation of states compared to a reduced order model. The results showed that using the temperature measurement at the DOC outlet improved the estimates of the CO , NO , NO2 and HC concentrations from the DOC. The SCR estimator was used to evaluate the effect of NH3 and NOX sensors on state estimation quality. Three sensor combinations of NOX sensor only, NH3 sensor only and both NOX and NH3 sensors were evaluated. The NOX only configuration had the worst performance, the NH3 sensor only configuration was in the middle and both the NOX and NH3 sensor combination provided the best performance.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The need for efficient, sustainable, and planned utilization of resources is ever more critical. In the U.S. alone, buildings consume 34.8 Quadrillion (1015) BTU of energy annually at a cost of $1.4 Trillion. Of this energy 58% is utilized for heating and air conditioning. Several building energy analysis tools have been developed to assess energy demands and lifecycle energy costs in buildings. Such analyses are also essential for an efficient HVAC design that overcomes the pitfalls of an under/over-designed system. DOE-2 is among the most widely known full building energy analysis models. It also constitutes the simulation engine of other prominent software such as eQUEST, EnergyPro, PowerDOE. Therefore, it is essential that DOE-2 energy simulations be characterized by high accuracy. Infiltration is an uncontrolled process through which outside air leaks into a building. Studies have estimated infiltration to account for up to 50% of a building’s energy demand. This, considered alongside the annual cost of buildings energy consumption, reveals the costs of air infiltration. It also stresses the need that prominent building energy simulation engines accurately account for its impact. In this research the relative accuracy of current air infiltration calculation methods is evaluated against an intricate Multiphysics Hygrothermal CFD building envelope analysis. The full-scale CFD analysis is based on a meticulous representation of cracking in building envelopes and on real-life conditions. The research found that even the most advanced current infiltration methods, including in DOE-2, are at up to 96.13% relative error versus CFD analysis. An Enhanced Model for Combined Heat and Air Infiltration Simulation was developed. The model resulted in 91.6% improvement in relative accuracy over current models. It reduces error versus CFD analysis to less than 4.5% while requiring less than 1% of the time required for such a complex hygrothermal analysis. The algorithm used in our model was demonstrated to be easy to integrate into DOE-2 and other engines as a standalone method for evaluating infiltration heat loads. This will vastly increase the accuracy of such simulation engines while maintaining their speed and ease of use characteristics that make them very widely used in building design.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Model predictive control (MPC) has often been referred to in literature as a potential method for more efficient control of building heating systems. Though a significant performance improvement can be achieved with an MPC strategy, the complexity introduced to the commissioning of the system is often prohibitive. Models are required which can capture the thermodynamic properties of the building with sufficient accuracy for meaningful predictions to be made. Furthermore, a large number of tuning weights may need to be determined to achieve a desired performance. For MPC to become a practicable alternative, these issues must be addressed. Acknowledging the impact of the external environment as well as the interaction of occupants on the thermal behaviour of the building, in this work, techniques have been developed for deriving building models from data in which large, unmeasured disturbances are present. A spatio-temporal filtering process was introduced to determine estimates of the disturbances from measured data, which were then incorporated with metaheuristic search techniques to derive high-order simulation models, capable of replicating the thermal dynamics of a building. While a high-order simulation model allowed for control strategies to be analysed and compared, low-order models were required for use within the MPC strategy itself. The disturbance estimation techniques were adapted for use with system-identification methods to derive such models. MPC formulations were then derived to enable a more straightforward commissioning process and implemented in a validated simulation platform. A prioritised-objective strategy was developed which allowed for the tuning parameters typically associated with an MPC cost function to be omitted from the formulation by separation of the conflicting requirements of comfort satisfaction and energy reduction within a lexicographic framework. The improved ability of the formulation to be set-up and reconfigured in faulted conditions was shown.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper proposes an algorithm to estimate two parameter values vs, transcription of frq gene, and vd, maximum rate of FRQ protein degradation for an existing 3rd order Neurospora model in literature. Details of the algorithm with simulation results are shown in this paper.