920 resultados para Aortic Valve Stenosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extended computational model of the circulatory system has been developed to predict blood flow in the presence of ventricular assist devices (VADs). A novel VAD, placed in the descending aorta, intended to offload the left ventricle (LV) and augment renal perfusion is being studied. For this application, a better understanding of the global hemodynamic response of the VAD, in essence an electrically driven pump, and the cardiovascular system is necessary. To meet this need, a model has been established as a nonlinear, lumped-parameter electrical analog, and simulated results under different states [healthy, congestive heart failure (CHF), and postinsertion of VAD] are presented. The systemic circulation is separated into five compartments and the descending aorta is composed of three components to accurately yield the system response of each section before and after the insertion of the VAD. Delays in valve closing time and blood inertia in the aorta were introduced to deliver a more realistic model. Pump governing equations and optimization are based on fundamental theories of turbomachines and can serve as a practical initial design point for rotary blood pumps. The model's results closely mimic established parameters for the circulatory system and confirm the feasibility of the intra-aortic VAD concept. This computational model can be linked with models of the pump motor to provide a valuable tool for innovative VAD design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The liquid-crystal light valve (LCLV) is a useful component for performing integration, thresholding, and gain functions in optical neural networks. Integration of the neural activation channels is implemented by pixelation of the LCLV, with use of a structured metallic layer between the photoconductor and the liquid-crystal layer. Measurements are presented for this type of valve, examples of which were prepared for two specific neural network implementations. The valve fabrication and measurement were carried out at the State Optical Institute, St. Petersburg, Russia, and the modeling and system applications were investigated at the Institute of Microtechnology, Neuchâtel, Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two control algorithms have been developed for a minimally invasive axial-flow ventricular assist device (VAD) for placement in the descending aorta. The purpose of the device is to offload the left ventricle and to augment lower body perfusion in patients with moderate congestive heart failure. The VAD consists of an intra-aortic impeller with a built-in permanent magnet rotor and an extra-aortic stator. The control algorithms, which use pressure readings upstream and downstream of the VAD to determine the pump status, have been tested in a mock circulatory system under two conditions, namely with or without afterload sensitivity. The results give an insight into controller design for an intra-aortic blood pump working in series with the heart.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A permanent-magnet motor has been designed for an innovative axial-flow ventricular assist device (VAD), to be placed in the descending aorta, intended to offload the left ventricle and augment renal perfusion in patients with congestive heart failure (CHF). For this application, an intra-aortic impeller with a built-in permanent magnet rotor is driven by an extraaortic stator working in synchronism with the natural heart. To meet this need, a two-dimensional analytical model has been developed in the MATLAB environment to estimate machine parameters; finite element analysis (FEA) has been used to refine the results. A prototype blood pump equipped with an innovative motor designed from the procedure above has been tested in a mock loop representing the human circulatory system. The performance of VAD incorporating the motor is presented. © 2009 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the design, optimization and testing of a self-regulating valve for single-phase liquid cooling of microelectronics. Its purpose is to maintain the integrated circuit (IC) at constant temperature and to reduce power consumption by diminishing flow generated by the pump as a function of the cooling requirements. It uses a thermopneumatic actuation principle that combines the advantages of zero power consumption and small size in combination with a high flow rate and low manufacturing costs. The valve actuation is provided by the thermal expansion of a liquid (actuation fluid) which, at the same time, actuates the valve and provides feed-back sensing. A maximum flow rate of 38 kg h-1 passes through the valve for a heat load up to 500 W. The valve is able to reduce the pumping power by up to 60% and it has the capability to maintain the IC at a more uniform temperature. © 2011 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the production and testing of an ortho-planar one-way micro-valve. The main advantages of such valves are that they are very compact and can be made from a single flat piece of material. A previous paper presents and discusses a micro-valve assembly based on a spider spring. The present paper focuses on the valve assembly process and the valve performance.. Several prototypes with a bore of 0.2 mm have been built using two manufacturing techniques (μEDM and stereo-lithography) and tested for pressures up to 7 bars. © 2008 International Federation for Information Processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main difficulties encountered in the development of microscale fluidic pumping systems stem from the fact that these systems tend to comprise highly three-dimensional parts, which are incompatible with traditional microproduction technologies. Regardless of the type of pumping principle, most of the hydraulic systems contain valves and in particular a one-way valve. This paper presents the design and modelling of an ortho-planar one-way microvalve. The main advantages of such a valve are that it is very compact and can be made from a single flat piece of material. An analytical model of the spring deflection has been developed and compared to FEM. A prototype with a bore of 1.5 mm has been build using a micro EDM (electro discharge machining) machine and also tested. © 2006 International Federation for Information Processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnetic properties of spin-valve pinned by FeMn layer were investigated after it was annealed at different temperatures. Its property was dependent on the vacuum annealing temperature. The pinning field could be increased through annealing at a temporature lower than 200degreesC;the pinning field would reduce and other properties be deteriorated as the annealing temperature was higher than 200degreesC; the pinning effect lost and giantmagnetic resistance disappeared at 300degreesC. Based on the results of AES analysis it was concluded that the diffusion in spin-valve multilayer was along grain boundary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experimental results show that the exchange coupling field of NiFe/FeMn for Ta/ NiFe/FeMn/Ta multilayers is higher than that for the spin valve multilayers Ta/NiFe/Cu/NiFe/FeMn/ Ta. In order to find out the reason, the composition and chemical states at the surfaces of Ta(12nm)/ NiFe(7nm), Ta(12nm)/NiFe(7nm)/Cu(4nm) and Ta(12nm)/NiFe(7nm)/Cu(3nm)/NiFe(5nm) were studied using the X-ray photoelectron spectroscopy (XPS). The results show that no elements from lower layers float out or segregate to the surface for the first and second samples. However, Cu atoms segregate to the surface of Ta(12nm)/NiFe(7nm)/Cu(3nm)/NiFe(5nm) multilayers, i.e. Cu atoms segregate to the NiFe/FeMn interface for Ta/NiFe/Cu/NiFe/FeMn/Ta multilayers. We believe that the presence of Cu atoms at the interface of NiFe/FeMn is one of the important factors causing the exchange coupling field of Ta/NiFe/FeMn/Ta multilayers to be higher than that of Ta/NiFe/Cu/NiFe/ FeMn/Ta multilayers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental results show that the exchange coupling field (H-ex) of NiFe/FeMn for Ta/NiFe/FeMn/Ta multilayers is higher than that for spin-valve multilayers Ta/NiFe/Cu/NiFe/FeMn/Ta. In order to find out the reason, the composition and chemical states at the surface of Ta(12 nm)/NiFe(7 nm), Ta(12 nm)/NiFe(7 nm)/Cu(4 nm), and Ta(12 nm)/NiFe(7 nm)/Cu(3 nm)/NiFe(5 nm) were studied using x-ray photoelectron spectroscopy. The results show that no elements from lower layers float out or segregate to the surface in the first and second samples. However, Cu atoms segregate to the surface of Ta(12 nm)/NiFe(7 nm)/Cu(3 nm)/NiFe(5 nm) multilayers, i.e., Cu atoms segregate to the NiFe/FeMn interface for Ta/NiFe/Cu/NiFe/FeMn/Ta multilayers. We believe that the presence of Cu atoms at the interface of NiFe/FeMn is one of the important factors which causes the exchange coupling field (H-ex) of Ta/NiFe/Cu/NiFe/FeMn/Ta to be weaker than that of Ta/NiFe/FeMn/Ta. (C) 2002 American Institute of Physics.