919 resultados para Actions on the case--New York (State)--New York--Early works to 1800


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to analyze the effects of formulations containing DMAE pidolate and DMAE acetoamidobenzoate on the skin. Four areas of five swines were submitted to following treatments during 15 days: C (Control), S (Silicone = 80 % DC*LC Blend (R)), F1 (DMAE acetoamidobenzoate), F2 (DMAE pidolate). Measures of the thickness of epidermis and stratum corneum, and the density population of fibroblasts and leukocytes in papillary dermis were obtained. We also assessed possible variations in birefringence of dermis collagen bundles. Means of the data was compared using ANOVA followed by the Tukey test. The F1 and F2 groups showed a thicker epidermis than the control group (p < 0.01), but did not demonstrate a significant difference in the number of fibroblasts and leukocytes, as well as in the birefringent areas of collagen bundles, in comparison with the control groups. The DMAE-supplemented formulations enhanced viable epidermis thickness, but did not modify structures related with mechanical properties of the skin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Classical Monte Carlo simulations were carried out on the NPT ensemble at 25°C and 1 atm, aiming to investigate the ability of the TIP4P water model [Jorgensen, Chandrasekhar, Madura, Impey and Klein; J. Chem. Phys., 79 (1983) 926] to reproduce the newest structural picture of liquid water. The results were compared with recent neutron diffraction data [Soper; Bruni and Ricci; J. Chem. Phys., 106 (1997) 247]. The influence of the computational conditions on the thermodynamic and structural results obtained with this model was also analyzed. The findings were compared with the original ones from Jorgensen et al [above-cited reference plus Mol. Phys., 56 (1985) 1381]. It is notice that the thermodynamic results are dependent on the boundary conditions used, whereas the usual radial distribution functions g(O/O(r)) and g(O/H(r)) do not depend on them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During microwave disinfection, the dentures are exposed to water at high temperature and this may affect the bond between the denture teeth and the acrylic resin from which dentures are made. In this study, a shear test was used to evaluate the effect of microwave disinfection (650W/6 min) on the bond strength of two types of denture teeth to three acrylic resins, with different polymerization methods. The specimens were submitted to the shear tests (0.5 mm/min) after: immersion in water (37 degrees C) for 48 h or 8 days (controls); two or seven cycles of microwave disinfection (test groups). Data (MPa) were analyzed using three-way ANOVA and Tukey HSD test (alpha = 0.05). Microwave disinfection did not adversely affect the bond strength of all tested materials with the exception of QC-20 bonded to SR Vivodent PE, for which a significant reduction was recorded after seven cycles of irradiation. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to 'detect occlusal caries.Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site.Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy far the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly.Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the Sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure.Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Investigation of the effectiveness of surface treatments that promote a strong bond strength of resin cements to metals can contribute significantly to the longevity of metal-ceramic restorations. This study evaluated the effect of surface treatments on the shear bond strength (SBS) of a resin cement to commercially pure titanium (CP Ti). Ninety cast CP Ti discs were divided into 3 groups (n=30), which received one of the following airborne-particle abrasion conditions: (1) 50 μm Al2O3 particles; (2) 30 μm silica-modified Al2O3 particles (Cojet Sand); (3) 110 μm silica-modified Al2O3 particles (Rocatec). For each airborne-particle abrasion condition, the following post-airborne-particle abrasion treatments were used (n=10): (1) none; (2) adhesive Adper Single Bond 2; (3) silane RelyX Ceramic Primer. RelyX ARC resin cement was bonded to CP Ti surfaces. All specimens were thermally cycled before being tested in shear mode. Failure mode was determined. The best association was Rocatec plus silane. All groups showed 100% adhesive failure. There were combinations that promote higher SBS than the protocol recommended by the manufacturer of RelyX ARC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The stride before landing may be important during stepping down. The aim of this study was to analyze variability of the kinematics and muscle activity in the final stride before stepping down a curb, with and without ankle and knee muscle fatigue. Ten young participants walked at self-selected speed and stepped down a height difference (10-cm) in ongoing gait. Five trials were performed before and after a muscle fatigue protocol (one day: ankle muscle fatigue, another day: knee muscle fatigue). The analysis focused on the trailing leg during the last but one and the last step on the higher level. Kinematics and muscle activity were recorded. Fatigue increased variability of foot-step horizontal distance in the last step on the higher level of the trailing limb, as well as in the first steps on the lower level for both limbs. This appeared due to an increase in the range of motion of the knee joint after both fatigue protocols. Participants additionally showed an increased ankle and hip ROM and decreased knee ROM. Our results suggest a loss of control under fatigue reflected in a higher variability of trailing and leading limb-step horizontal distances, with compensatory changes to limit fatigue effects, such as a redistribution of movement over joints. © 2012 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Climate change affects the fundamental bases of good human health, which are clean air, safe drinking water, sufficient food, and secure shelter. Climate change is known to impact health through three climate dimensions: extreme heat, natural disasters, and infections and diseases. The temporal and spatial climatic changes that will affect the biology and ecology of vectors and intermediate hosts are likely to increase the risks of disease transmission. The greatest effect of climate change on disease transmission is likely to be observed at the extremes of the range of temperatures at which transmission typically occurs. Caribbean countries are marked by unique geographical and geological features. When combined with their physical, infrastructural development, these features make them relatively more prone to negative impacts from changes in climatic conditions. The increased variability of climate associated with slow-moving tropical depressions has implications for water quality through flooding as well as hurricanes. Caribbean countries often have problems with water and sanitation. These problems are exacerbated whenever there is excess rainfall, or no rainfall. The current report aims to prepare the Caribbean to respond better to the anticipated impact of climate change on the health sector, while fostering a subregional Caribbean approach to reducing carbon emissions by 2050. It provides a major advance on the analytical and contextual issues surrounding the impact of climate change on health in the Caribbean by focusing on the vector-borne and waterborne diseases that are anticipated to be impacted directly by climate change. The ultimate goal is to quantify both the direct and indirect costs associated with each disease, and to present adaptation strategies that can address these health concerns effectively to benefit the populations of the Caribbean.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of diamond-like carbon (DLC) coating of prefabricated implant abutment on screw removal torque (RT) before and after mechanical cycling (MC).Materials and Methods: Fifty-four abutments for external-hex implants were divided among 6 groups (n = 9): S, straight abutment (control); SC, straight coated abutment; SCy, straight abutment and MC; SCCy, straight coated abutment and MC; ACy, angled abutment and MC; and ACCy, angled coated abutment and MC. The abutments were attached to the implants by a titanium screw. RT values were measured and registered. Data (in Newton centimeter) were analyzed with analysis of variance and Dunnet test (alpha = 0.05).Results: RT values were significantly affected by MC (P = 0.001) and the interaction between DLC coating and MC (P = 0.038). SCy and ACy showed the lowest RT values, statistically different from the control. The abutment coated groups had no statistical difference compared with the control. Scanning electron microscopy analysis showed DLC film with a thickness of 3 mm uniformly coating the hexagonal abutment.Conclusion: DLC film deposited on the abutment can be used as an alternative procedure to reduce abutment screw loosening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Climate change has significantly influenced vegetation dynamics on the Tibetan Plateau (TP). Past research mainly focused on vegetation responses to temperature variation and water stress, but the influence of sunshine duration on NDVI and vegetation phenology on the TP is not well understood. In this study, NDVI time series from 1982-2008 were used to retrieve spatiotemporal vegetation dynamics on the TP. Empirical orthogonal function (EOF) analysis was conducted to understand the spatiotemporal variations of NDVI. The Start of Season (SOS) was estimated from NDVI time series with a local threshold method. The first EOF, accounting for 35.1% of NDVI variations on the TP, indicates that NDVI variations are larger in areas with shorter sunshine duration. The needle-leaved forest and shrub in the southeastern TP are more sensitive to sunshine duration anomalies (p < 0.01) than broad-leaved forest, steppe, and meadow due to spatial and altitudinal distribution of sunshine duration and vegetation types. The decrease in sunshine duration for the growing season on the TP has resulted in a decreased NDVI trend in some areas of southeastern TP (p ranging from 0.32-0.05 with threshold ranging from 0.05 to 0.25) in spite of the overall NDVI increase. SOS dynamics in most parts of the TP were mainly related to temperature variability, with precipitation and sunshine duration playing a role in a few regions. This study enhances our understanding of vegetation responses to climatic change on the TP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a procedure for the on-line process control of variables is proposed. This procedure consists of inspecting the m-th item from every m produced items and deciding, at each inspection, whether the process is out-of-control. Two sets of limits, warning (µ0 ± W) and control (µ0 ± C), are used. If the value of the monitored statistic falls beyond the control limits or if a sequence of h observations falls between the warning limits and the control limits, the production is stopped for adjustment; otherwise, production goes on. The properties of an ergodic Markov chain are used to obtain an expression for the average cost per item. The parameters (the sampling interval m, the widths of the warning, the control limits W and C(W < C), and the sequence length (h) are optimized by minimizing the cost function. A numerical example illustrates the proposed procedure.