992 resultados para Abastecimento de água - Desenvolvimento - Brasil
Resumo:
This paper aimed to give a contribution to improve water resources management, consists of the analysis of interaction among groundwater and streamflow, by through the analysis of the relationship between basic and total streamflow, based on measured hidrological data from Ribeirão Boa Vista or Córrego Lajeado. watershed. Comparisons among groundwaterflow in this basin with another one in Rio Corumbataí basin were made based on the specific basic flow, in order to verify the possibility of the utilization of measured hydrological data in other basins with similar geological characteristics and soil use and occupation. Based upon the comparisons that were made, specific basic flow does not represent a good tool for extrapolation of measured data, indicating that this comparison shall be weighted by others characteristics as permeability and thickness of geological formations. Finally, it was possible to conclude that basic flow may be considered as an additional parameter for analysis of hydrological and hydrogeological characteristics of a basin and to provide subsidies to release legal licenses for water resources uses. related to surface water as well as for groundwater and may also be used as a tool for consolidation of integrated management of water resources, that is considered as a necessary and essential practice to avoid conflicts between users of water resources in a river basin.
Resumo:
About eighty percent of the Brazilian municipalities have their residues in environmentally unsuitable sites and socially insalubrious. In this context, in the year 2010, instituted the National Policy on Solid Residues, which aims to integrated management and management environmentally appropriate of solid residues in Brazil (JUCA, 2002).The problem of urban residues is related to its origin and production in the same way that the concept of inexhaustibility and reflexes of compromising the environment, especially the pollution of soil, air and water resources (LIMA, 1995). Seeking a better residues management in the municipality of Apuí / AM and continuing work already started, Plan Solid Residues Management of the Apuí / AM, this work came to propose a better environmental compliance in relation to solid residues compared to 12305/2010 law that established deadlines / timelines on some actions such as landfills and the consequent elimination of environmentally sound disposal of residues by 2014 and thus began a study of potential areas for the implementation of the landfill were evaluated taking into consideration technical aspects (soil, vegetation, climate, hydrography, etc), legislation and Google Earth imagery. The result of the work over the 6 areas proposed by the City Hall was the choice of AREA 4 as the most indicated for the implementation of the landfill for the city of Apuí, which has 18,325 inhabitants (IBGE, 2011); some considerations were made if a new area can be proposed by the city to implement the landfill
Resumo:
Não disponível
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Introduction: The fluoridation surveillance in the public water supply came up with the need to develop mechanisms that would help society in the control of water quality. To perform reliable analysis, variables such as depth of the wells and pluvial variations should be subject of research and study. Objectives: To analyze the fluoride levels of deep wells in periods of rain and drought, corresponding to four brazilian cities and compare the results. Methodology: It was made the mapping of the water supply network and the identification of the sampling points according to the number of deep wells in each locality, selecting those who had the natural fluoride level. Three points were defined for each source of water supply, and the addresses were randomly selected. The samples were analyzed in duplicate at the laboratory of the Center for Research in Public Health of the Dentistry School of Araçatuba – UNESP, during 8 months, in periods of rain and drought (total absence of rain). Results: 174 analysis were conducted, the mean fluoride levels for rain and drought times were, respectively: 0,71 and 0,73. It was used the Student’s t test (p <0.05). Conclusion: There wasn’t statistically significant differences for the periods of rain and drought in any of the cities, at the year of 2010. This study highlights the importance of health surveillance, because beyond of ensuring social control, there is also the search for investigating variables that may have directly and / or indirectly influence on the results of the analysis.
Resumo:
Pós-graduação em Geociências e Meio Ambiente - IGCE
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
beta(2)-adrenergic receptor (beta(2)-AR) agonists have been used as ergogenics by athletes involved in training for strength and power in order to increase the muscle mass. Even though anabolic effects of beta(2)-AR activation are highly recognized, less is known about the impact of beta(2)-AR in endurance capacity. We presently used mice lacking beta(2)-AR [beta(2)-knockout (beta(2) KO)] to investigate the role of beta(2)-AR on exercise capacity and skeletal muscle metabolism and phenotype. beta(2) KO mice and their wild-type controls (WT) were studied. Exercise tolerance, skeletal muscle fiber typing, capillary-to-fiber ratio, citrate synthase activity and glycogen content were evaluated. When compared with WT, beta 2KO mice displayed increased exercise capacity (61%) associated with higher percentage of oxidative fibers (21% and 129% of increase in soleus and plantaris muscles, respectively) and capillarity (31% and 20% of increase in soleus and plantaris muscles, respectively). In addition, beta 2KO mice presented increased skeletal muscle citrate synthase activity (10%) and succinate dehydrogenase staining. Likewise, glycogen content (53%) and periodic acid-Schiff staining (glycogen staining) were also increased in beta 2KO skeletal muscle. Altogether, these data provide evidence that disruption of beta(2)AR improves oxidative metabolism in skeletal muscle of beta 2KO mice and this is associated with increased exercise capacity.
Resumo:
Exercise training is a well-known coadjuvant in heart failure treatment; however, the molecular mechanisms underlying its beneficial effects remain elusive. Despite the primary cause, heart failure is often preceded by two distinct phenomena: mitochondria dysfunction and cytosolic protein quality control disruption. The objective of the study was to determine the contribution of exercise training in regulating cardiac mitochondria metabolism and cytosolic protein quality control in a post-myocardial infarction-induced heart failure (MI-HF) animal model. Our data demonstrated that isolated cardiac mitochondria from MI-HF rats displayed decreased oxygen consumption, reduced maximum calcium uptake and elevated H2O2 release. These changes were accompanied by exacerbated cardiac oxidative stress and proteasomal insufficiency. Declined proteasomal activity contributes to cardiac protein quality control disruption in our MI-HF model. Using cultured neonatal cardiomyocytes, we showed that either antimycin A or H2O2 resulted in inactivation of proteasomal peptidase activity, accumulation of oxidized proteins and cell death, recapitulating our in vivo model. Of interest, eight weeks of exercise training improved cardiac function, peak oxygen uptake and exercise tolerance in MI-HF rats. Moreover, exercise training restored mitochondrial oxygen consumption, increased Ca2+-induced permeability transition and reduced H2O2 release in MI-HF rats. These changes were followed by reduced oxidative stress and better cardiac protein quality control. Taken together, our findings uncover the potential contribution of mitochondrial dysfunction and cytosolic protein quality control disruption to heart failure and highlight the positive effects of exercise training in re-establishing cardiac mitochondrial physiology and protein quality control, reinforcing the importance of this intervention as a nonpharmacological tool for heart failure therapy.
Resumo:
As intervenções de saneamento básico, ou seja, as obras para implantação ou ampliação de sistemas de abastecimento de água e de esgotamento sanitário têm sido relacionadas à redução das taxas de mortalidade infantil ocorrida no estado de São Paulo nas últimas décadas. De fato, a relação entre saneamento básico e saúde pública é antiga, principalmente no que se refere ao controle das doenças de veiculação hídrica. Entretanto, ela se mostra muito fraca, ou até nula, para regiões onde os índices de cobertura por redes de água e esgotos já se encontram em patamares acima da média nacional, como é o caso de grande parte dos municípios do estado de São Paulo. Uma abordagem do saneamento básico, sob o ponto de vista da complexidade de suas relações, considerando aspectos multidimensionais, faz-se necessária como forma de repensar o setor de forma mais ampla, fugindo do senso comum. O objetivo desta pesquisa foi identificar, analisar e descrever indicadores de sustentabilidade que pudessem estabelecer uma nova base para avaliação de efeitos de intervenções de saneamento básico, melhorando a determinação e acompanhamento dos impactos decorrentes, constituindo, então, uma matriz de indicadores específicos para a área, a partir da investigação dos conceitos de sustentabilidade e seus desdobramentos para o setor saneamento básico e o ambiente empresarial. Pesquisas em bases de dados públicas permitiram a identificação e seleção de indicadores multidimensionais para o saneamento, assim como a análise de correlação entre os indicadores selecionados possibilitou identificar possíveis benefícios de curto, médio e longo prazos, oriundos das intervenções de saneamento para os municípios do Vale do Ribeira. Utilizando modelos de organização de indicadores, como o Triple Bottom Line (TBL) e a matriz de indicadores FPSEEA, da Organização Mundial da Saúde (OMS), com algumas adaptações, foi possível agrupar os indicadores de forma a permitir uma visão integrada das dimensões da sustentabilidade e, dessa maneira, determinar que as intervenções de saneamento básico possuem relações sistêmicas com indicadores sociais, ambientais e econômicos, que possibilitem, a partir de sua execução, o estabelecimento de um círculo virtuoso para os municípios
Resumo:
As adutoras são consideradas, por alguns autores, como sendo as principais componentes de um Sistema de Abastecimento de Água (SAA), dado o seu elevado custo e importância para o funcionamento desses sistemas. A sua função reside em transportar água desde as captações até aos reservatórios de distribuição. As adutoras são compostas por condutas que podem ser gravíticas (desnível favorável) ou por bombeamento (desnível desfavorável). Nas adutoras por bombeamento, dado que é necessário fornecer energia ao sistema para elevar água, os custos de exploração representam uma parcela muito importante dos custos globais destes sistemas adutores. Dada a crescente dimensão e complexidade dos sistemas de adução, face à tendência de crescimento dos consumos, nos últimos anos, a comunidade científica tem-se debruçado sobre o estudo destes sistemas, particularmente dos sistemas por bombeamento, tendo em vista a sua otimização, quer do seu dimensionamento quer da sua operação. Em Portugal, os SAA encontram-se separados em duas vertentes, nomeadamente, os sistemas em alta (captação, transporte e armazenamento) e os sistemas em baixa (distribuição). Nas últimas décadas, talvez fruto dessa divisão, assistiu-se ao abandono das adutoras mistas (com distribuição de percurso), em favor das adutoras puras (sem distribuição de percurso). No entanto, tal decisão não foi devidamente acompanhada de estudos de viabilidade técnico-económica que, fundamentadamente, pudessem justificar se essa decisão terá ou não sido acertada. Nesse sentido, esta dissertação pretende avaliar para dois exemplos práticos de adutoras por bombeamento, uma pura e outra mista, aplicando metodologias de otimização para o dimensionamento e a operação, quais os custos de investimento e de energia associados a cada um, por forma a aferir qual dos sistemas é de facto mais económico. Do estudo efetuado, foi possível concluir que a adutora mista apresenta um custo global significativamente inferior ao da adutora pura, contribuído para esse facto a redução considerável nos custos de energia elétrica para a operação do sistema e a redução do custo do troço de distribuição (desde o reservatório até à rede). Além do aspeto meramente económico, importa também referir que a redução dos custos de energia e do troço de distribuição traz também importantes vantagens do ponto de vista ambiental.