867 resultados para workability optimisation
Resumo:
One of the most difficult problems that face researchers experimenting with complex systems in real world applications is the Facility Layout Design Problem. It relies with the design and location of production lines, machinery and equipment, inventory storage and shipping facilities. In this work it is intended to address this problem through the use of Constraint Logic Programming (CLP) technology. The use of Genetic Algorithms (GA) as optimisation technique in CLP environment is also an issue addressed. The approach aims the implementation of genetic algorithm operators following the CLP paradigm.
Resumo:
This paper presents MASCEM - a multi-agent based electricity market simulator. MASCEM uses game theory, machine learning techniques, scenario analysis and optimisation techniques to model market agents and to provide them with decision-support. This paper mainly focus on the MASCEM ability to provide the means to model and simulate Virtual Power Producers (VPP). VPPs are represented as a coalition of agents, with specific characteristics and goals. The paper detail some of the most important aspects considered in VPP formation and in the aggregation of new producers and includes a case study.
Resumo:
To comply with natural gas demand growth patterns and Europe´s import dependency, the gas industry needs to organize an efficient upstream infrastructure. The best location of Gas Supply Units – GSUs and the alternative transportation mode – by phisical or virtual pipelines, are the key of a successful industry. In this work we study the optimal location of GSUs, as well as determining the most efficient allocation from gas loads to sources, selecting the best transportation mode, observing specific technical restrictions and minimizing system total costs. For the location of GSUs on system we use the P-median problem, for assigning gas demands nodes to source facilities we use the classical transportation problem. The developed model is an optimisation-based approach, based on a Lagrangean heuristic, using Lagrangean relaxation for P-median problems – Simple Lagrangean Heuristic. The solution of this heuristic can be improved by adding a local search procedure - the Lagrangean Reallocation Heuristic. These two heuristics, Simple Lagrangean and Lagrangean Reallocation, were tested on a realistic network - the primary Iberian natural gas network, organized with 65 nodes, connected by physical and virtual pipelines. Computational results are presented for both approaches, showing the location gas sources and allocation loads arrangement, system total costs and gas transportation mode.
Resumo:
The impact of shift and night work on health shows a high inter- and intra-individual variability, both in terms of kind of troubles and temporal occurrence, related to various intervening factors dealing with individual characteristics, lifestyles, work demands, company organisation, family relations and social conditions. The way we define "health" and "well-being" can significantly influence appraisals, outcomes and interventions. As the goal is the optimisation of shiftworkers' health, it is necessary to go beyond the health protection and to act for health promotion. In this perspective, not only people related to medical sciences, but many other actors (ergonomists, psychologists, sociologists, educators, legislators), as well as shiftworkers themselves. Many models have been proposed aimed at describing the intervening variables mediating and/or moderating the effects; they try to define the interactions and the pathways connecting risk factors and outcomes through several human dimensions, which refer to physiology, psychology, pathology, sociology, ergonomics, economics, politics, and ethics. So, different criteria can be used to evaluate shiftworkers' health and well-being, starting from biological rhythms and ending in severe health disorders, passing through psychological strain, job dissatisfaction, family perturbation and social dis-adaptation, both in the short- and long-term. Consequently, it appears rather arbitrary to focus the problem of shiftworkers' health and tolerance only on specific aspects (e.g. individual characteristics), but a systemic approach appears more appropriate, able to match as many variables as possible, and aimed at defining which factors are the most relevant for those specific work and social conditions. This can support a more effective and profitable (for individuals, companies, and society) adoption of preventive and compensative measures, that must refer more to "countervalues" rather than to "counterweights".
Resumo:
Versão integral da revista no link do editor
Resumo:
Copyright © 2013 Springer Netherlands.
Resumo:
Mestrado em Engenharia Electrotécnica e de Computadores
Resumo:
This paper deals with the coupled effect of temperature and silica fume addition on rheological, mechanical behaviour and porosity of grouts based on CEMI 42.5R, proportioned with a polycarboxylate-based high range water reducer. Preliminary tests were conducted to focus on the grout best able to fill a fibrous network since the goal of this study was to develop an optimized grout able to be injected in a mat of steel fibers for concrete strengthening. The grout composition was developed based on criteria for fresh state and hardened state properties. For a CEMI 42.5R based grout different high range water reducer dosages (0%, 0.2%, 0.4%, 0.5%, 0.7%) and silica fume (SF) dosages (0%, 2%, 4%) were tested (as replacement of cement by mass). Rheological measurements were used to investigate the effect of polycarboxylates (PCEs) and SF dosage on grout properties, particularly its workability loss, as the mix was to be injected in a matrix of steel fibers for concrete jacketing. The workability behaviour was characterized by the rheological parameters yield stress and plastic viscosity (for different grout temperatures and resting times), as well as the procedures of mini slump cone and funnel flow time. Then, further development focused only on the best grout compositions. The cement substitution by 2% of SF exhibited the best overall behaviour and was considered as the most promising compared to the others compositions tested. Concerning the fresh state analysis, a significant workability loss was detected if grout temperature increased above 35 degrees C. Below this temperature the grout presented a self-levelling behaviour and a life time equal to 45 min. In the hardened state, silica fumes increased not only the grout's porosity but also the grout's compressive strength at later ages, since the pozzolanic contribution to the compressive strength does not occur until 28 d and beyond. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
One of the most effective ways of controlling vibrations in plate or beam structures is by means of constrained viscoelastic damping treatments. Contrary to the unconstrained configuration, the design of constrained and integrated layer damping treatments is multifaceted because the thickness of the viscoelastic layer acts distinctly on the two main counterparts of the strain energy the volume of viscoelastic material and the shear strain field. In this work, a parametric study is performed exploring the effect that the design parameters, namely the thickness/length ratio, constraining layer thickness, material modulus, natural mode and boundary conditions have on these two counterparts and subsequently, on the treatment efficiency. This paper presents five parametric studies, namely, the thickness/length ratio, the constraining layer thickness, material properties, natural mode and boundary conditions. The results obtained evidence an interesting effect when dealing with very thin viscoelastic layers that contradicts the standard treatment efficiency vs. layer thickness relation; hence, the potential optimisation of constrained and integrated viscoelastic treatments through the use of properly designed thin multilayer configurations is justified. This work presents a dimensionless analysis and provides useful general guidelines for the efficient design of constrained and integrated damping treatments based on single or multi-layer configurations. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Dissertação de natureza Científica para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Edificações
Resumo:
O trabalho tem como objectivo a simulação e verificação do funcionamento de 3 colunas de destilação, a T-0303, a T-0306 e a T-0307, integrantes do processo de produção de p-xileno, baseado nos dados relativos ao ano de 2008, existente na refinaria da Galp no Porto. A abordagem consistiu em utilizar o AspenPlus quer para a simulação quer para a optimização, sendo esta última complementada com um planeamento experimental e optimização no Minitab15. O critério de optimização foi estabelecido a partir de uma análise ao processo actual, na qual se averiguou que se poderia, no limite: produzir mais 15,30ton.ano-1 de p-xileno no conjunto de colunas T-0306 e T-0307; remover mais 1,36ton.ano-1 de dessorvente na coluna T-0303 e diminuir a energia necessária para o processo. Da optimização à coluna T-0303, obteve-se uma melhoria de remoção de 0,34ton.ano-1 de dessorvente, e uma diminuição na energia necessária para 333,24.106kWh por ano. Para obter esta optimização houve necessidade de ultrapassar em 109,852kW a potência da bomba P0306A/S e alterou-se a razão de refluxo na base para 46,1. A optimização conjunta das colunas T-0306 e T-0307 apenas possibilita uma melhoria de p-xileno de 3,4ton.ano-1. De uma optimização individual da coluna T-0307, mantendo a coluna T-0306 nas condições actuais, obteve-se uma melhoria na produção de p-xileno de 14,62ton.ano-1. Neste ensaio as potências do condensador E-0314, do reebulidor E-0306 e da bomba P0314A/S excedem, as actuais em, respectivamente, 35,71kW, 35,74kW e 0,12kW. Enquanto para a situação actual o custo de p-xileno equivale a 722,17€.ton-1, para a optimização simultânea da coluna T-0303 e T-0307, é de 723,39€.ton-1 e para a optimização de apenas da coluna T-0307 é de 722,81€.ton-1. Perante um preço de venda actual de pxileno de 749,10€.ton-1 todas as situações são favoráveis. Em suma, é possível uma optimização processual mas o custo por tonelada de pxileno fica superior ao actual.
Resumo:
The electroactivity of butylate (BTL) is studied by cyclic voltammetry (CV) and square wave voltammetry (SWV) at a glassy carbon electrode (GCE) and a hanging mercury drop electrode (HMDE). Britton–Robinson buffer solutions of pH 1.9–11.5 are used as supporting electrolyte. CV voltammograms using GCE show a single anodic peak regarding the oxidation of BTL at +1.7V versus AgCl/ Ag, an irreversible process controlled by diffusion. Using a HMDE, a single cathodic peak is observed, at 1.0V versus AgCl/Ag. The reduction of BTL is irreversible and controlled by adsorption. Mechanism proposals are presented for these redox transformations. Optimisation is carried out univaryingly. Linearity ranges were 0.10–0.50 mmol L-1 and 2.0–9.0 µmolL-1 for anodic and cathodic peaks, respectively. The proposed method is applied to the determination of BTL in waters. Analytical results compare well with those obtained by an HPLC method.
Resumo:
Conferência: 39th Annual Conference of the IEEE Industrial-Electronics-Society (IECON) - NOV 10-14, 2013
Resumo:
This paper presents a complete, quadratic programming formulation of the standard thermal unit commitment problem in power generation planning, together with a novel iterative optimisation algorithm for its solution. The algorithm, based on a mixed-integer formulation of the problem, considers piecewise linear approximations of the quadratic fuel cost function that are dynamically updated in an iterative way, converging to the optimum; this avoids the requirement of resorting to quadratic programming, making the solution process much quicker. From extensive computational tests on a broad set of benchmark instances of this problem, the algorithm was found to be flexible and capable of easily incorporating different problem constraints. Indeed, it is able to tackle ramp constraints, which although very important in practice were rarely considered in previous publications. Most importantly, optimal solutions were obtained for several well-known benchmark instances, including instances of practical relevance, that are not yet known to have been solved to optimality. Computational experiments and their results showed that the method proposed is both simple and extremely effective.