857 resultados para variable amplitude loading
Resumo:
Carbon Fibre Reinforced Carbon (CFRC) Composites are increasing their applications due to their high strength and Youngs Modulus at high temperatures in inert atmosphere. Although much work has been done on processing and structure and properties relationship, few studies have addressed the modelling of mechanical properties. This work is divided in two parts. In the first part, a modelling of mechanical properties was carried out for two bi-directional composites using a model based on the Bernoulli-Euler theory for symmetric laminated beams. In the second part, acoustic emission (AE) was used as an auxiliary technique for monitoring the failure process of the composites. Differences in fracture behaviour are reflected in patterns of AE.
Resumo:
An early experiment found that a square rubber sheet under symmetric biaxial loading may not remain square. This curious result has been one of the most instructive examples in finite elasticity. Here thermodynamic considerations are used to analyze this instability.
Resumo:
The use of a robust position controller for a robotic manipulator moving in free space is presented. The aim is to implement in practice a controller that is robust to uncertainties in the model of the system, as well as being inexpensive from a computational point of view. Variable structure theory provides the technique for the design of such controller. The design steps are presented, first from a theoretical perspective and then applied to the control of a two degree-of-freedom manipulator. Simulation results that backed the implementation are presented, followed by the experiments conducted and the results that were obtained. The conclusion is that variable structure control is readily applicable to industrial robots for the robust control of positions.
Resumo:
Control of an industrial robot is mainly a problem of dynamics. It includes non-linearities, uncertainties and external perturbations that should be considered in the design of control laws. In this work, two control strategies based on variable structure controllers (VSC) and a PD control algorithm are compared in relation to the tracking errors considering friction. The controller's performances are evaluated by adding an static friction model. Simulations and experimental results show it is possible to diminish tracking errors by using a model based friction compensation scheme. A SCARA robot is used to illustrate the conclusions of this paper.
Resumo:
Tässä diplomityössä on tutkittu tehollisen lovijännityksen menetelmän soveltuvuutta ultralujien terästen korkealaatuisten hitsien väsymismitoitukseen. International Institute of Welding suosittelee käyttämään elementtimenetelmässä hitsin rajaviivoilla sekä juuressa fiktiivistä 1 mm pyöristystä, jonka avulla tehollinen lovijännitys määritetään. Kaikille liitostyypeille sovelletaan samaa, kaltevuudeltaan m = 3 olevaa SN-käyrää, jolloin maksimipääjännitystä vastaava väsymisluokka FAT saa arvon 225. Nykyisiä mitoitusohjeita on pidetty kuitenkin liian konservatiivisina, etenkin jos kyseessä on suurilujuuksisesta teräksestä valmistettu korkealaatuinen hitsi. Rajaviivalla vaikuttavaa lovijännitystä on tutkittu mallintamalla liitokset FEMAP – elementtimenetelmäohjelmalla varioimalla rajaviivan pyöristystä. Elementtimenetelmän tuloksia on verrattu analyyttisiin loven muotoluvun laskentakaavoihin. Tutkittavana on ollut Ruukin Optim 960 QC sekä Optim 1100 QC – teräksistä valmistettuja koesauvoja. Koesauvat on valmistettu sekä koestettu pääasiassa Lappeenrannan teknillisen yliopiston teräsrakenteiden laboratoriossa. Tutkittavat koesauvat ovat olleet kuormaa kantamattomia ristiliitoksia sekä päittäisliitoksia. Suurin osa koesauvoista on väsytetty käyttämällä jännityssuhdetta R < 0,11. Koesauvat on jaoteltu jännityssuhteen sekä liitostyypin mukaan. Kaikkien koekappaleiden karakteristiseksi väsymisluokan arvoksi on määritetty FAT 200. Alle 0,11 jännityssuhteella väsytettyjen koekappaleiden karakteristinen väsymisluokka on FAT 230 ja isoilla jännityssuhteilla väsytettyjen FAT 126. Tulosten perusteella nykyiset mitoitusohjeet eivät ole liian konservatiivisia. Väsymisluokkaa FAT 225 voidaan käyttää väsymislaskennassa, mikäli rakenteen kuormitusten suhde on alle 0,1. Isoilla jännityssuhteilla koestettujen koekappaleiden lukumäärä on ollut pieni, joten niiden mitoitukselle ei voida antaa tarkkoja ohjeita.
Resumo:
Fan systems are responsible for approximately 10% of the electricity consumption in industrial and municipal sectors, and it has been found that there is energy-saving potential in these systems. To this end, variable speed drives (VSDs) are used to enhance the efficiency of fan systems. Usually, fan system operation is optimized based on measurements of the system, but there are seldom readily installed meters in the system that can be used for the purpose. Thus, sensorless methods are needed for the optimization of fan system operation. In this thesis, methods for the fan operating point estimation with a variable speed drive are studied and discussed. These methods can be used for the energy efficient control of the fan system without additional measurements. The operation of these methods is validated by laboratory measurements and data from an industrial fan system. In addition to their energy consumption, condition monitoring of fan systems is a key issue as fans are an integral part of various production processes. Fan system condition monitoring is usually carried out with vibration measurements, which again increase the system complexity. However, variable speed drives can already be used for pumping system condition monitoring. Therefore, it would add to the usability of a variablespeed- driven fan system if the variable speed drive could be used as a condition monitoring device. In this thesis, sensorless detection methods for three lifetime-reducing phenomena are suggested: these are detection of the fan contamination build-up, the correct rotational direction, and the fan surge. The methods use the variable speed drive monitoring and control options for the detection along with simple signal processing methods, such as power spectrum density estimates. The methods have been validated by laboratory measurements. The key finding of this doctoral thesis is that a variable speed drive can be used on its own as a monitoring and control device for the fan system energy efficiency, and it can also be used in the detection of certain lifetime-reducing phenomena.
Resumo:
The pumping processes requiring wide range of flow are often equipped with parallelconnected centrifugal pumps. In parallel pumping systems, the use of variable speed control allows that the required output for the process can be delivered with a varying number of operated pump units and selected rotational speed references. However, the optimization of the parallel-connected rotational speed controlled pump units often requires adaptive modelling of both parallel pump characteristics and the surrounding system in varying operation conditions. The available information required for the system modelling in typical parallel pumping applications such as waste water treatment and various cooling and water delivery pumping tasks can be limited, and the lack of real-time operation point monitoring often sets limits for accurate energy efficiency optimization. Hence, alternatives for easily implementable control strategies which can be adopted with minimum system data are necessary. This doctoral thesis concentrates on the methods that allow the energy efficient use of variable speed controlled parallel pumps in system scenarios in which the parallel pump units consist of a centrifugal pump, an electric motor, and a frequency converter. Firstly, the suitable operation conditions for variable speed controlled parallel pumps are studied. Secondly, methods for determining the output of each parallel pump unit using characteristic curve-based operation point estimation with frequency converter are discussed. Thirdly, the implementation of the control strategy based on real-time pump operation point estimation and sub-optimization of each parallel pump unit is studied. The findings of the thesis support the idea that the energy efficiency of the pumping can be increased without the installation of new, more efficient components in the systems by simply adopting suitable control strategies. An easily implementable and adaptive control strategy for variable speed controlled parallel pumping systems can be created by utilizing the pump operation point estimation available in modern frequency converters. Hence, additional real-time flow metering, start-up measurements, and detailed system model are unnecessary, and the pumping task can be fulfilled by determining a speed reference for each parallel-pump unit which suggests the energy efficient operation of the pumping system.
Resumo:
This doctoral thesis introduces an improved control principle for active du/dt output filtering in variable-speed AC drives, together with performance comparisons with previous filtering methods. The effects of power semiconductor nonlinearities on the output filtering performance are investigated. The nonlinearities include the timing deviation and the voltage pulse waveform distortion in the variable-speed AC drive output bridge. Active du/dt output filtering (ADUDT) is a method to mitigate motor overvoltages in variable-speed AC drives with long motor cables. It is a quite recent addition to the du/dt reduction methods available. This thesis improves on the existing control method for the filter, and concentrates on the lowvoltage (below 1 kV AC) two-level voltage-source inverter implementation of the method. The ADUDT uses narrow voltage pulses having a duration in the order of a microsecond from an IGBT (insulated gate bipolar transistor) inverter to control the output voltage of a tuned LC filter circuit. The filter output voltage has thus increased slope transition times at the rising and falling edges, with an opportunity of no overshoot. The effect of the longer slope transition times is a reduction in the du/dt of the voltage fed to the motor cable. Lower du/dt values result in a reduction in the overvoltage effects on the motor terminals. Compared with traditional output filtering methods to accomplish this task, the active du/dt filtering provides lower inductance values and a smaller physical size of the filter itself. The filter circuit weight can also be reduced. However, the power semiconductor nonlinearities skew the filter control pulse pattern, resulting in control deviation. This deviation introduces unwanted overshoot and resonance in the filter. The controlmethod proposed in this thesis is able to directly compensate for the dead time-induced zero-current clamping (ZCC) effect in the pulse pattern. It gives more flexibility to the pattern structure, which could help in the timing deviation compensation design. Previous studies have shown that when a motor load current flows in the filter circuit and the inverter, the phase leg blanking times distort the voltage pulse sequence fed to the filter input. These blanking times are caused by excessively large dead time values between the IGBT control pulses. Moreover, the various switching timing distortions, present in realworld electronics when operating with a microsecond timescale, bring additional skew to the control. Left uncompensated, this results in distortion of the filter input voltage and a filter self-induced overvoltage in the form of an overshoot. This overshoot adds to the voltage appearing at the motor terminals, thus increasing the transient voltage amplitude at the motor. This doctoral thesis investigates the magnitude of such timing deviation effects. If the motor load current is left uncompensated in the control, the filter output voltage can overshoot up to double the input voltage amplitude. IGBT nonlinearities were observed to cause a smaller overshoot, in the order of 30%. This thesis introduces an improved ADUDT control method that is able to compensate for phase leg blanking times, giving flexibility to the pulse pattern structure and dead times. The control method is still sensitive to timing deviations, and their effect is investigated. A simple approach of using a fixed delay compensation value was tried in the test setup measurements. The ADUDT method with the new control algorithm was found to work in an actual motor drive application. Judging by the simulation results, with the delay compensation, the method should ultimately enable an output voltage performance and a du/dt reduction that are free from residual overshoot effects. The proposed control algorithm is not strictly required for successful ADUDT operation: It is possible to precalculate the pulse patterns by iteration and then for instance store them into a look-up table inside the control electronics. Rather, the newly developed control method is a mathematical tool for solving the ADUDT control pulses. It does not contain the timing deviation compensation (from the logic-level command to the phase leg output voltage), and as such is not able to remove the timing deviation effects that cause error and overshoot in the filter. When the timing deviation compensation has to be tuned-in in the control pattern, the precalculated iteration method could prove simpler and equally good (or even better) compared with the mathematical solution with a separate timing compensation module. One of the key findings in this thesis is the conclusion that the correctness of the pulse pattern structure, in the sense of ZCC and predicted pulse timings, cannot be separated from the timing deviations. The usefulness of the correctly calculated pattern is reduced by the voltage edge timing errors. The doctoral thesis provides an introductory background chapter on variable-speed AC drives and the problem of motor overvoltages and takes a look at traditional solutions for overvoltage mitigation. Previous results related to the active du/dt filtering are discussed. The basic operation principle and design of the filter have been studied previously. The effect of load current in the filter and the basic idea of compensation have been presented in the past. However, there was no direct way of including the dead time in the control (except for solving the pulse pattern manually by iteration), and the magnitude of nonlinearity effects had not been investigated. The enhanced control principle with the dead time handling capability and a case study of the test setup timing deviations are the main contributions of this doctoral thesis. The simulation and experimental setup results show that the proposed control method can be used in an actual drive. Loss measurements and a comparison of active du/dt output filtering with traditional output filtering methods are also presented in the work. Two different ADUDT filter designs are included, with ferrite core and air core inductors. Other filters included in the tests were a passive du/dtfilter and a passive sine filter. The loss measurements incorporated a silicon carbide diode-equipped IGBT module, and the results show lower losses with these new device technologies. The new control principle was measured in a 43 A load current motor drive system and was able to bring the filter output peak voltage from 980 V (the previous control principle) down to 680 V in a 540 V average DC link voltage variable-speed drive. A 200 m motor cable was used, and the filter losses for the active du/dt methods were 111W–126 W versus 184 W for the passive du/dt. In terms of inverter and filter losses, the active du/dt filtering method had a 1.82-fold increase in losses compared with an all-passive traditional du/dt output filter. The filter mass with the active du/dt method was 17% (2.4 kg, air-core inductors) compared with 14 kg of the passive du/dt method filter. Silicon carbide freewheeling diodes were found to reduce the inverter losses in the active du/dt filtering by 18% compared with the same IGBT module with silicon diodes. For a 200 m cable length, the average peak voltage at the motor terminals was 1050 V with no filter, 960 V for the all-passive du/dt filter, and 700 V for the active du/dt filtering applying the new control principle.
Resumo:
Com o objetivo de avaliar o efeito dos sistemas de plantio direto e convencional e estratégias de manejo de plantas daninhas na variação da temperatura do solo e na produtividade de pimentão, realizou-se, na Universidade Federal do Semiárido, em Mossoró-RN, um experimento no esquema de parcelas subdivididas, distribuídas no delineamento experimental em blocos casualizados com quatro repetições. Os sistemas de plantio direto e convencional do pimentão foram avaliados nas parcelas; nas subparcelas, avaliaram-se três estratégias de manejo de plantas daninhas (cobertura do solo com filme de polietileno preto, com capinas e sem capinas). Em cada subparcela foram instalados sensores tipo termopares, a 5 cm de profundidade, para medir a temperatura do solo. A partir dos dados obtidos, determinou-se a variação da temperatura ao longo do dia, no período de 20 a 30 dias após o plantio das mudas de pimentão, e a cada cinco dias, a média das temperaturas máxima e mínima e a amplitude térmica diária. Aos 60 e 147 dias após o transplante das mudas de pimentão, foram feitas avaliações da densidade e massa seca de plantas daninhas nos tratamentos sem capinas. Os tratamentos com filme de polietileno e capinado no sistema de plantio convencional apresentaram elevação na temperatura máxima diária do solo em 6,7 e 5,0 ºC, respectivamente, em relação ao sistema de plantio direto com capinas. A amplitude térmica no sistema de plantio convencional nos tratamentos com capinas regulares e com filme de polietileno foi de 11 ºC, ao passo que no sistema de plantio direto a amplitude foi de 6,3, 4,5 e 4,0 ºC nos tratamentos com capinas, sem capinas e com filme de polietileno, respectivamente. A interferência das plantas daninhas nos tratamentos sem capinas resultou em redução de 94,95 e 92,10% da produtividade comercial nos sistemas de plantio direto e convencional, respectivamente.
Resumo:
The human immunoglobulin lambda variable locus (IGLV) is mapped at chromosome 22 band q11.1-q11.2. The 30 functional germline v-lambda genes sequenced untill now have been subgrouped into 10 families (Vl1 to Vl10). The number of Vl genes has been estimated at approximately 70. This locus is formed by three gene clusters (VA, VB and VC) that encompass the variable coding genes (V) responsible for the synthesis of lambda-type Ig light chains, and the Jl-Cl cluster with the joining segments and the constant genes. Recently the entire variable lambda gene locus was mapped by contig methodology and its one- megabase DNA totally sequenced. All the known functional V-lambda genes and pseudogenes were located. We screened a human genomic DNA cosmid library and isolated a clone with an insert of 37 kb (cosmid 8.3) encompassing four functional genes (IGLV7S1, IGLV1S1, IGLV1S2 and IGLV5a), a pseudogene (VlA) and a vestigial sequence (vg1) to study in detail the positions of the restriction sites surrounding the Vl genes. We generated a high resolution restriction map, locating 31 restriction sites in 37 kb of the VB cluster, a region rich in functional Vl genes. This mapping information opens the perspective for further RFLP studies and sequencing
Resumo:
Early stimulation has been shown to produce long-lasting effects in many species. Prenatal exposure to some strong stressors may affect development of the nervous system leading to behavioral impairment in adult life. The purpose of the present work was to study the postnatal harmful effects of exposure to variable mild stresses in rats during pregnancy. Female Holtzman rats were submitted daily to one session of a chronic variable stress (CVS) during pregnancy (prenatal stress; PS group). Control pregnant rats (C group) were undisturbed. The pups of PS and C dams were weighed and separated into two groups 48 h after delivery. One group was maintained with their own dams (PS group, N = 70; C group, N = 36) while the other PS pups were cross-fostered with C dams (PSF group, N = 47) and the other C pups were cross-fostered with PS dams (CF group, N = 58). Pups were undisturbed until weaning (postnatal day 28). The male offspring underwent motor activity tests (day 28), enriched environment tests (day 37) and social interaction tests (day 42) in an animal activity monitor. Body weight was recorded on days 2, 28 and 60. The PS pups showed lower birth weight than C pups (Duncan's test, P<0.05). The PS pups suckling with their stressed mothers displayed greater preweaning mortality (C: 23%, PS: 60%; c2 test, P<0.05) and lower body weight than controls at days 28 and 60 (Duncan's test, P<0.05 and P<0.01, respectively). The PS, PSF and CF groups showed lower motor activity scores than controls when tested at day 28 (Duncan's test, P<0.01 for PS group and P<0.05 for CF and PSF groups). In the enriched environment test performed on day 37, between-group differences in total motor activity were not detected; however, the PS, CF and PSF groups displayed less exploration time than controls (Duncan's test, P<0.05). Only the PS group showed impaired motor activity and impaired social behavior at day 42 (Duncan's test, P<0.05). In fact, CVS treatment during gestation plus suckling with a previously stressed mother caused long-lasting physical and behavioral changes in rats. Cross-fostering PS-exposed pups to a dam which was not submitted to stress counteracted most of the harmful effects of the treatment. It is probable that prenatal stress plus suckling from a previously stressed mother can induce long-lasting changes in the neurotransmitter systems involved in emotional regulation. Further experiments using neurochemical and pharmacological approaches would be interesting in this model.
Resumo:
We describe the expression of an anti-Z-DNA single chain variable region antibody fragment (scFv) on a filamentous phage surface. Four vectors for phage display were constructed. Two of them are able to display multiple copies of the antibody fragment, and the others can be used to make monovalent libraries. The vectors use different promoter/leader sequences to direct the expression of the fused proteins. All were able to promote the assembly of fusion virion particles. In this paper we also show the affinity selection (biopanning) of those phage-antibodies based on the capacity of their products to recognize the antigen. We used biotinylated Z-DNA and the selection was performed in a solution phase fashion. The data presented here indicate that these vectors can be further used to construct anti-nucleic acid antibody fragment libraries that can be used to study the basis of nucleic acid-protein interaction and its role in autoimmunity mechanisms.
Resumo:
The human immunoglobulin lambda variable 8 (IGLV8) subgroup is a gene family containing three members, one of them included in a monomorphic 3.7-kb EcoRI genomic fragment located at the major lambda variable locus on chromosome 22q11.1 (gene IGLV8a, EMBL accession No. Z73650) at 100% frequency in the normal urban population. The second is a polymorphic RFLP allele included in a 6.0-kb EcoRI fragment at 10% frequency, and the third is located in a monomorphic 8.0-kb EcoRI fragment at 100% frequency, the last being translocated to chromosome 8q11.2 and considered to be an orphan gene. Our Southern blot-EcoRI-RFLP studies in normal individuals and in patients with rheumatoid arthritis (RA) or with systemic lupus erythematosus (SLE), using a specific probe for the IGLV8 gene family (probe pVL8, EMBL accession No. X75424), have revealed the two monomorphic genomic fragments containing the IGLV8 genes, i.e., the 3.7-kb fragment from chromosome 22q11.1 and the 8.0-kb fragment from 8q11.2, both occurring at 100% frequency (103 normal individuals, 48 RA and 28 SLE patients analyzed), but absence of the 6.0-kb IGLV8 polymorphic RFLP allele in all RA or SLE patients. As expected, the frequency of the 6.0-kb allele among the normal individuals was 10%. These findings suggest an association between the absence of the 6.0-kb EcoRI fragment and rheumatoid arthritis and systemic lupus erythematosus.
Resumo:
Tämä kandidaatintyö tarkastelee rakeisen materiaalin seulontaan liittyviä käsitteitä ja laitteita, etsii optimaalisia parametreja seulonnan erotustehokkuudelle laboratorio-olosuhteissa sekä verifioi aikaisempien tutkimuksien simulointimallia. Mittauksessa seulottiin erikokoisia lasipalloja. Mittausten muuttuvia parametreja olivat seulatason värähtelyn taajuus, kaltevuus ja syöttömassa. Värähtely edistää partikkelien kerrostumista, kaltevuus lisää partikkelien vierintänopeutta ja syöttömassan lisääminen tarkoittaa suurempaa kapasiteettia. Mittausten perusteella värähtelyn ja kaltevuuden lisääminen parantaa erotustehokkuutta. Sen sijaan liiallinen kaltevuuden ja syöttömassan lisääminen heikentää erotustehokkuutta. Seulonnan erotustehokkuudet määritettiin alitteiden kokonaismassan perusteella. Tässä työssä kokeellisesti määritettyjä erotustehokkuuden arvoja verrattiin Rotich et al. [2013, 2014] kehittämän seulan simulointimallin tuloksiin. Malli simuloi seulan erotustehokkuutta eri seulan parametreilla ja mallin antamat simulointitulokset noudattivat hyvin tässä työssä saatuja kokeellisia mittaustuloksia.
Resumo:
Kirjallisuusarvostelu