561 resultados para risonanza, magnetica, cardiaca, miocarditi
Resumo:
The use of multimodal neuroimaging techniques has been helpful in the investigation of epileptogenic zone in patients with refractory epilepsies. This work aims to describe an ictal event during EEG-fMRI performed simultaneously in a 39-year-old man with refractory epilepsy. The EEG data were recorded at a sampling rate of 5 kHz, using a BrainAmp (BrainProducts, München, Germany) amplifier, with 64 MR (magnetic resonance) compatible Ag/AgCl electrodes. MR images were acquired using a 3T scanner in 3 sequences of 6 minutes of echo-planar images (EPIs), with TR = 2s, being the last sequence stopped after the ictal event. The EEG was corrected for gradient and pulse artifacts using the Brain Vision Analyzer2 software (BrainProducts), and the functional images were realigned, slice-timing corrected, normalized and smoothed. The start of the ictal changes was used for the evaluation of the BOLD response in MR images, using a t-test with a minimum cluster of 5 voxels, p <0.005 (T>2.5). The patient had a partial complex seizure, as noted by neurologist. The fMRI data showed positive BOLD responses (activation) in dysplastic areas, but showed the most significant activation outside the lesion, in areas compatible with secondary spread of the epileptic focus, probably caused by motor reaction also observed during the seizure. As a conclusion, we note that the technique of EEG-fMRI can detect the epileptogenic zone in patients with refractory epilepsy, but areas of dissemination of primary epileptogenic focus may show significant activation, introducing additional difficulties to the interpretation of the results
Resumo:
The Biosusceptometry AC (BAC) is a research tool that has been extensively explored by the group Biomagnetism IBB-UNESP for monitoring of the gastrointestinal tract, its response to a known drug or in vivo performance of solid dosage forms. During this period the BAC, which has the characteristics of high sensitivity and low cost, has been developed primarily for recording signals contraction of activity and traffic human gastrointestinal tract. With the possibility of producing images with this instrumentation, it was possible to evaluate different situations in vitro and in vivo for physiological studies and pharmaceuticals. Considering the good performance of this system to produce planar images, the first aim of the BAC system tomography (TBAC) was to evaluate the system performance of BAC to produce tomographic images of phantoms ferromagnetic for a single channel system. All these applications were only possible because of their sensitivity to materials of high magnetic suscepitibility as ferrite, which allow to produce an electrical signal proportional to the variation of the magnetic flux generated by the presence of magnetic marker next to a first-order gradiometer. Measuring this variation at various points was possible to generate planar images that recently came to be produced in systems with multiple detectors, said multi-channels. From planar images, also producing tomographic images of simulators BAC bars in a system of 13 channels using only the center channel, with good results when applied to simple objects as one and two bars. When testing the resolution of the system with more elaborate forms the quality and resolution of images reconstructed is not satisfactory, which would be solved by increasing the spatial sampling rate and hence the acquisition time. The present system works with an acquisition time of about five hours. Whereas this system will be applied for in vivo experiments, the acquisition time became a ...
Resumo:
This work will discuss how magnetic fields can be produced, either generated by magnets, natural, artificial, or even by an electric current going through a wire, as discovered by Oersted. Besides the theoretical content, experimental studies on magnetic induction and on the Laws of Faraday and Lenz will be performed. In the Magnetic Induction experiment, the electromotive force generated by varying the flow of the field B in a solenoid, depending on the variation of the current intensity and frequency associated with it will be measured; the experiment on the Laws of Faraday and Lenz the electromotive force produced by the relative movement of the magnet in relation to a coil. Thus, this study experimental verification of magnetic induction using solenoids and magnets; analysis of magnetic induction by Faraday's Law and Lenz's Law
Resumo:
A parameter commonly used in investigations of environmental magnetism is the magnetic susceptibility (MS), which is the quantitative measure of the ability of magnetization of a specific material in the presence of an induced magnetic field. The present study aimed to determine the magnetic susceptibility of sediments collected on the continental shelf near the Santos Basin, southeast of the São Sebastião island (25°57.97’S 45°07.81'W), seeking to identify the possible source area of terrigenous sediments and the flow patterns of siliciclastic sediment yield in the area. It was used particle size analysis and contents of organic matter and calcium carbonate to characterize the sediments, besides paleomagnetism parameters. The analyzed material - core NAP61-1 - was collected using the piston corer sampler in 60 meters water depth, recovering 3.98 meters of sediment core. As from experiments, cyclicity was observed in relative abundance between sand and silt, most likely due to rapid and cyclical variations in the depositional environment. In general, the MS values are low, and show that the sand supply (terrigenous material) has a certain consistency, probably having the same origin. More absolute age is still necessary to establish clearly the events marked here
Resumo:
Magnetic resonance imaging (MRI), which is studied since 1938, is a technique used in medicine to produce high quality images from inside the human body. These images are produced non-invasively and without ionizing radiation. In addition, MRI is an extremely flexible technique, with which it is possible to produce images with different contrasts that provide different information about the anatomy, structure and function of the human body, and it is therefore one of the techniques preferred by radiologists. The phenomenon of MRI is based on the interaction of magnetic fields with the nuclear spins of the scanned sample. In this work a detailed study of the technique of magnetic resonance imaging is presented, with a description of the main features of the images produced by the technique and an analysis of its application to the fields of applications Neurology and Neuroscience
Resumo:
A insuficiência cardíaca (IC) está associada à miopatia dos músculos esqueléticos com aumento da expressão das isoformas rápidas da cadeia pesada de miosina e alterações na matriz extracelular. Os fatores de regulação miogência(MRF),como a MyoD e MRF4, pertecem a uma família de fatores transcricionais que controlam vários genes músculo-específicos.Esses fatores forma heterodímeros com proteínas HLH e ligam-se a seqüências de DNA conhecidas como Ebox, presentes na região promotora de vários genes músculo–específicos, incluindo todos aqueles que codificam as subunidades dos receptores nicotínicos de acetilcolina (nAChR) da junção neuromuscular (JNM). Baseado no fato de que na IC há uma diminuição na expressão da MyoD e MRF4 no músculo sóleo de ratos com IC induzida por monocrotalina, o objetivo do presente trabalho é verificar possíveis alterações na expressão dos receptores de acetilcolina, bem como realizar uma análise morfológica e morfométrica das JNMs. Neste estudo foram utilizados ratos Wistar, machos, divididos em grupos controle e experimental e a Insuficiência cardíaca (IC) foi induzida pela injeção de monocrotalina intra-peritoneal.Quando os sintomas de IC foram visualizados (após 22 dias) os animais foram sacrificados pentobarbital sódico i.p. (50 mg/Kg). A seguir foram mensurados o peso corporal (PC) dos ratos, bem como outros parâmetros. O músculo sóleo de ambos os antímeros foram dissecados e preparados para: avaliação da expressão gênica das subunidades ε, γ e α dos receptores de acetilcolina por PCR em Tempo Real; para análise morfológica e morfométrica da Junção Neuromuscular através da técnica de Esterase inespecífica; para análise ultra-estrutural da JN. Os resultados indicam que não houveram alterações morfológicas e morfométricas na JN, mas houve um aumento... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
The plasma represents a average of the information referring biochemists to the physiology of the organism as a whole, therefore it indirectly or directly interacts with all tissues of the body. In such a way the plasma can be considered as a metabolic “soup”. Using the Nuclear Magnetic Resonance Spectroscopy sanguineous plasma spectra had been generated and using deconvolution techniques it was possible to know the contribution of the albumin for the formation of the spectra of the sanguineous plasma
Resumo:
Pós-graduação em Agronomia (Ciência do Solo) - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of this work was to evaluate the electrocardiography effects (ECG), sedation time and quality of recovery due to buprenorphine (G1) and butorphanol (G2) administration in dogs pretreated with acepromazine. Seven adult dogs were submitted to both protocols, with a thirty days interval between groups. G1 animals were premedicated with acepromazine (0.1 mg/kg) followed 10 minutes later with buprenorphine (0.005 mg/kg), both applied intravenously. The same procedure was performed for G2 employing butorphanol (0.3 mg/kg) instead of buprenorphine. The measurements of the variables heart rate (HR), duration and amplitude of P wave, P-R intervals (PR), QRS complex duration, R wave amplitude, Q-T intervals (QT) and R-R intervals (RR) were taken immediately before application of acepromazine (M0), 10 minute after administration of acepromazine (M10) and 10 minutes after opioids administration (M20). Serial measurements were carried out in 10 minute intervals after the administration of butorphanol or buprenorphine up to 60 minutes. Numeric data were submitted to Tukey Analysis (p < 0.05). The amplitude of P wave decreased 30 minutes after the administration of the butorphanol. Sedation time was longer in G1 (78 minutes) than G2 (72 minutes) and recovery was good in both groups. These results indicate that butorphanol or buprenorphine produced discreet alterations on ECG, which don´t contraindicate its clinical use.