1000 resultados para resistividade elétrica
Resumo:
The generation of electricity in Brazil is predominantly renewable, with internal hydraulic generation being more than 70% of its energy matrix. The electricity rationing occurred in 2001 due to lack of rain, led the country to increase the participation of alternative energy sources. This need for new sources of energy makes the regional potential to be exploited, which configures the change of generation model from centralized generation to distributed generation. Among the alternative sources of energy, the solar energy is presented as very promising for Brazil, given that most of its territory is located near to the equator line, which implies days with greater number of hours of solar radiation. The state of Rio Grande do Norte (RN) has one of the highest levels of solar irradiation of the Brazilian territory, making it eligible to receive investments for the installation of photovoltaic solar plants. This thesis will present the state-of-the-art in solar photovoltaic power generation and will examine the potential for generation of solar photovoltaic power in Brazil and RN, based on solarimetrics measurements conducted by various institutions and also measurements performed in Natal, the state capital
Resumo:
Atualmente há uma grande preocupação em relação a substituição das fontes não renováveis pelas fontes renováveis na geração de energia elétrica. Isto ocorre devido a limitação do modelo tradicional e da crescente demanda. Com o desenvolvimento dos conversores de potência e a eficácia dos esquemas de controle, as fontes renováveis têm sido interligadas na rede elétrica, em um modelo de geração distribuída. Neste sentido, este trabalho apresenta uma estratégia de controle não convencional, com a utilização de um controlador robusto, para a interconexão de sistemas fotovoltaicos com à rede elétrica trifásica. A compensação da qualidade de energia no ponto de acoplamento comum (PAC) é realizada pela estratégia proposta. As técnicas tradicionais utilizam detecção de harmônicos, já neste trabalho o controle das correntes é feita de uma forma indireta sem a necessidade desta detecção. Na estratégia indireta é de grande importância que o controle da tensão do barramento CC seja efetuado de uma forma que não haja grandes flutuações, e que a banda passante do controlador em regime permanente seja baixa para que as correntes da rede não tenham um alto THD. Por este motivo é utilizado um controlador em modo dual DSM-PI, que durante o transitório se comporta como um controlador em modo deslizante SM-PI, e em regime se comporta como um PI convencional. A corrente é alinhada ao ângulo de fase do vetor tensão da rede elétrica, obtido a partir do uso de um PLL. Esta aproximação permite regular o fluxo de potência ativa, juntamente com a compensação dos harmônicos e também promover a correção do fator de potência no ponto de acoplamento comum. Para o controle das correntes é usado um controlador dupla sequencia, que utiliza o princípio do modelo interno. Resultados de simulação são apresentados para demonstrar a eficácia do sistema de controle proposto
Resumo:
Currently, there are several power converter topologies applied to wind power generation. The converters allow the use of wind turbines operating at variable speed, enabling better use of wind forces. The high performance of the converters is being increasingly demanded, mainly because of the increase in the power generation capacity by wind turbines, which gave rise to various converter topologies, such as parallel or multilevel converters. The use of converters allow effective control of the power injected into the grid, either partially, for the case using partial converter, or total control for the case of using full converter. The back-to-back converter is one of the most used topologies in the market today, due to its simple structure, with few components, contributing to robust and reliable performance. In this work, is presented the implementation of a wind cogeneration system using a permanent magnet synchronous generator (PMSG) associated with a back-to-back power converter is proposed, in order to inject active power in an electric power system. The control strategy of the active power delivered to the grid by cogeneration is based on the philosophy of indirect control
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O teste de condutividade elétrica (CE) tem potencial para ser empregado no controle de qualidade pelas empresas produtoras de sementes, no entanto há fatores que podem afetar os resultados obtidos. Neste sentido, o trabalho teve como objetivo estudar os efeitos do tamanho da semente, do número de sementes da amostra e do período e temperatura de embebição que podem influenciar a interpretação dos resultados do teste de CE, em sementes de amendoim. Utilizou-se o delineamento experimental inteiramente casualizado em esquema fatorial 3 x 3: três lotes de semente, classificados em três tamanhos (peneiras 18, 20 e 22). Avaliou-se a CE em dez tempos de embebição (3, 6, 9, 12, 15, 18, 21, 24, 27 e 30 horas). O trabalho foi composto de quatro ensaios, onde se combinou número de sementes e temperatura de exposição das mesmas à embebição: a) quatro repetições de 25 sementes a 20ºC; b) quatro repetições de 50 sementes a 20ºC; c) quatro repetições de 25 sementes a 25ºC; d) quatro repetições de 50 sementes a 25ºC. A leitura da CE foi realizada por condutivímetro e os resultados expressos em µS.cm-1.g-1. O tamanho da semente afetou os resultados da CE; o tempo de embebição pode ser reduzido para até 3 horas; a temperatura de embebição de 25ºC mostrou-se mais promissora do que 20ºC, assim como a utilização de 50 sementes puras.
Resumo:
Na floricultura, a competição por mercados é intensa e o diferencial de produtividade consiste no manejo nutricional adequado, por promover grande impacto sobre a qualidade, a produtividade e a longevidade das inflorescências e da planta. O presente trabalho teve o objetivo de avaliar os efeitos de níveis de condutividade elétrica (CE) no desenvolvimento de plantas de crisântemo (Dendranthema grandiflora Tzvelev.) em vaso sob cultivo protegido. O experimento foi conduzido no município de Paranapanema - SP. Usou-se o delineamento experimental de blocos casualizados com quatro repetições e parcelas divididas. As parcelas foram constituídas pelas épocas de amostragem, e as subparcelas, pelos diferentes níveis de CE, determinados na solução aplicada via água de irrigação: 1,42; 1,65; 1,89; 2,13 e 2,36 dS m-1 (fase vegetativa); 1,71; 1,97; 2,28; 2,57 e 2,85 dS m-1 (fase de botão). Determinaram-se, semanalmente, a altura da planta e o diâmetro do buquê, e a cada 14 dias, a área foliar e a fitomassa seca da parte aérea da planta. O tratamento, correspondente à aplicação de solução com CE de 2,13 dS m-1 na fase vegetativa e 2,57 dS m-1 na fase de botão, proporcionou melhor aspecto visual das plantas, além de apresentar maior valor de fitomassa seca da parte aérea, maior área foliar e melhores formação e coloração.
Resumo:
Thermoelectric Refrigerators (TEC Thermoelectric Cooling) are solid-state heat pumps used in applications where stabilization of temperature cycles or cooling below the room temperature are required. TEC are based on thermoelectric devices, and these in turn, are based on the Peltier effect, which is the production of a difference in temperature when an electric current is applied to a junction formed by two non-similar materials. This is one of the three thermoelectric effects and is a typical semiconductor junction phenomenon. The thermoelectric efficiency, known as Z thermoelectric or merit figure is a parameter that measures the quality of a thermoelectric device. It depends directly on electrical conductivity and inversely on the thermal conductivity. Therefore, good thermoelectric devices have typically high values of electrical conductivity and low values of thermal conductivity. One of the most common materials in the composition of thermoelectric devices is the semiconductor bismuth telluride (Bi2Te3) and its alloys. Peltier plates made up by crystals of semiconductor P-type and N-type are commercially available for various applications in thermoelectric systems. In this work, we characterize the electrical properties of bismuth telluride through conductivity/resistivity of the material, and X-rays power diffraction and magnetoresistance measurements. The results were compared with values taken from specific literature. Moreover, two techniques of material preparation, and applications in refrigerators, are discussed
Resumo:
Patellofemoral pain syndrome (PFPS) is described as anterior or retropatellar pain knee in the absence of other pathologies and is frequently associated with dysfunction of the vastus medialis oblique (VMO). However, several studies have demonstrated the inability to selectively activate this muscle through exercise. To evaluate the effect of Neuromuscular Electrical Stimulation (NMES) selective VMO in women with syndrome. We evaluated thirty-eight women: twenty in the control group (24.15 ± 2.60 years) and eighteen diagnosed with PFPS (25.56 ± 3.55 years). Both groups were evaluated before and after a protocol of electro stimulation. To measure for comparing groups before and after treatment, we assessed the extensor torque concentric and eccentric knee through an isokinetic dynamometer, the intensity (Root Mean Square - RMS) and the onset of activation (onset) of VMO compared to the vastus lateralis (VL) in two types of exercise: open and closed kinetic chain. . Statistical analysis was performed using SPSS 15.0, with a significance level of 5%. Results: Our data showed an increase in the intensity of activation (RMS) of the VMO muscle after NMES in both study groups. During concentric contraction the RMS of the VMO before the NMES was 105.69 ± 32.26 μV and after a single intervention was 122.10 ± 39.62 μV (p = 0.048) for the control group. In the group with PPS, we found a similar behavior, with RMS of the VMO before NMES of 96.25 ± 18.83 μV and 139.80 ± 65.88 μV after the intervention (p = 0.0001). However, there was no evidence in the RMS value of VL muscle. The onset was calculated by subtracting the onset of VL by the onset of VMO. For the group with PFPS, the onset before the intervention was -0.007 ± 0.14 ms, indicating a delay of the VMO relative to VL, and after NMES was 0.074 ± 0.09 ms (p = 0.016), showing an activation previous VMO to VL. The same occurred for the control group. We also observed that NMES increased knee extensor power during the concentric contraction in both groups. Before the intervention the mean power was 28.97 ± 9.01 W for the PPS group and after NMES was 34.38 ± 7.61 W (p = 0.0001). Conclusion: We observed an increase in electromyographic activity of the VMO and also an anticipatory effect of this muscle
Resumo:
The reduction of physiological capacity present in the process of aging causes a marked decline in lung function. The exercise does promote several positive changes in the physical health of people and protect the cardiorespiratory function. The aim of this study was to investigate the effects of a program of Pilates exercices on the strengh and electrical activity of respiratory muscles of elderly. This is a randomized, controlled clinical trial, evaluating 33 elderly aged 65 and 80 (70.88 ± 4.32), healthy, sedentary, without cognitive impairment and able the practice physical activity. The sample was divided into two groups, one experimental group with 16 elderly women who did Pilates exercises and a control group (17) that was not submitted to the exercises, but received educational booklets on aging and health care. The elderly were evaluated initially and after a period of three months, taking into account the Maximal Inspiratory Pressure (MIP) and Maximal Expiratory Pressure (MEP), obtained by Manovacuometry and intensity of EMG activity was measured using the values of Root Mean Square (RMS) for the diaphragm and rectus abdominis muscles, during the course of diaphragmatic breathing and MIP maneuver. Data were analyzed using SPSS version 17.0. For all tests, we used a significance level or p value < 0.05 and confidence interval 95%. RMS in diaphragm and rectus abdominis muscles in both tests increased, but the data were significant for the rectus abdominis during diaphragmatic breathing (p = 0.03) and the diaphragm during the MIP maneuver (p = 0.01). There was no significant variation of the MIP and MEP. Pilates exercises were responsible for increasing the electrical activation of the diaphragm and rectus abdominis muscles in a group of healthy elderly, but had no influence on changes in strength of respiratory muscles
Resumo:
Este artigo apresenta os principais resultados e o detalhamento da metodologia e equações de controle de um retificador monofásico pré-regulador de 150kW para sistema trólebus. A estrutura proposta possibilita a Correção ativa do Fator de Potência (CFP) com baixos níveis de Distorção Harmônica Total (DHT) na corrente, em conformidade com a norma internacional IEC 61000-3-4. Fruto de um projeto de Pesquisa, Desenvolvimento e Inovação (P) junto à empresa AES Eletropaulo Metropolitana de São Paulo, em parceria com a empresa de transporte Himalaia S.A., o projeto possui como principais objetivos estimular o interesse para a expansão das linhas de trólebus a partir de uma plataforma de alimentação de menor custo de instalação e manutenção, sem a necessidade de subestações retificadoras, e, com vistas a promover a melhoria da qualidade de vida nos grandes centros urbanos. Nessa nova modalidade proposta para o sistema de alimentação, o trólebus pode ser alimentado tanto pelas redes convencionais em corrente contínua (CC) quanto pelas redes de distribuição em corrente alternada (CA), mantendo-se a disposição a dois fios dos sistemas CC, sendo as mudanças de rede de alimentação (CC ou CA) monitoradas e controladas digitalmente. Todo o sistema de gerenciamento e controle do conversor é realizado digitalmente por FPGA XC3S200. Na evolução do sistema proposto, os autores pretendem inclusive eliminar as linhas aéreas de alimentação, através da utilização de postos de alimentação em CA, especialmente desenvolvidos para os pontos de embarque/desembarque de passageiros para este veículo de transporte coletivo, eliminando-se os aspectos visuais negativos das redes de alimentação deste modal, e, reduzindo-se as falhas de operação do sistema.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O trabalho teve por objetivo estudar metodologias para a condução do teste de condutividade elétrica, verificando sua eficiência na identificação de diferentes níveis de vigor de lotes de sementes de rúcula. Para tanto, o estudo foi conduzido utilizando cinco lotes de sementes de Rúcula Cultivada e cinco lotes de sementes de Rúcula Gigante. Foram realizados os testes de germinação, primeira contagem de germinação, emergência de plântulas em casa de vegetação e variações no teste de condutividade elétrica (temperaturas de 20ºC, 25ºC e 30ºC; volumes de 25mL, 50mL e 75mL de água; 25 e 50 sementes; e períodos de 1, 2, 4, 6, 8, 12, 16 e 24 horas). Diante dos resultados obtidos, verificou-se que o tempo de embebição para o teste de condutividade elétrica pode ser reduzido para 4 horas e o volume de água utilizado pode ser reduzido para 25 ou 50mL. As combinações de 50 sementes apresentaram menor coeficiente de variação e as temperaturas mais adequadas foram de 25ºC e 30ºC. Assim, concluiu-se que a condição mais adequada para o teste de condutividade elétrica em sementes de rúcula é a utilização de 50 sementes em 50mL de água por 4 horas, a 25ºC.
Resumo:
The high quality of seed trading for producers is very important to obtain high productivity. The aim of this work was to evaluate the effects of different periods of artificial seed aging on contents of sugars, proteins, amino acids and ions, on imbibition solution of electrical conductivity test, as well as its relationships with standard germination and vigor in bean seeds at the Perola cultivar. The research was carried out at the Laboratory of Seed Analysis - Faculdade de Engenharia - Unesp - Campus de Ilha Solteira. The experimental design was in completely randomized blocks. The seeds were submitted to eight accelerated aging conditions (zero, 24, 48, 72, 96, 120, 144 and 168 hours). The seed germination, seed vigor and leakage contents in exudates of bulk conductivity were Influenced by the increase in the time of seed exposition to accelerated aging. After seventy-two hours of exposition to the aging, a considerable decline in seed germination and vigor was observed. There was also an increase of leakage contents, such as amino acids, sugars, potassium and phosphorus ions. The increase of leakage contents is inversely related to seeds germination and vigor.
Resumo:
This work presents results derived from a study related to impact on non-controllable costs in the determination of energy taxes. This is done analyzing tax review practiced by concessionaries responsible for the distribution of electrical energy located in the Northeastern Region of Brazil, between 2003 and 2004. This Region was chosen as a study area due to the researcher s expectation in congregating companies that deliver services to markets that have similar social-economical profiles. A brief explanation related to the restructuring of the electrical sector in Brazil is presented, pointing out that there was privatization of the great majority of these companies. The study also points out the definition of regulating rules in service delivery process. The components of taxes that are practiced by these companies aimed at final consumers, as well as the market as a whole and the revision process that is executed by Agência Nacional de Energia Elétrica ANEEL for the definition of these taxes are demonstrated in the research. A brief historical of the concessionaires that were focus of the research is presented, totaling five companies. Some data used by ANEEL in the tax review process was analyzed as well as data on components of approved taxes. It is concluded that as a media 47, 49% of the components of taxes in the researched companies correspond to the non-controllable costs. These is done considering previous classification by ANEEL in the tax review process. Although, if it is considered that these companies since 2006, by the means of participation in energy auctions are able to negotiate energy prices for their own needs, it is concluded that these concession contracts guarantee the delivery of the service to the costumer in the total tribute. The percentage of non-controllable costs is 16, 27% average of the tax. This means, amongst other information, that the government has a great deal of responsibility in the formation of price practiced by these companies and its target markets