989 resultados para radiocarbon calibration
Resumo:
Fifteen samples of burnt olive pits discovered inside a jar in the destruction layer of the Iron Age city of Khirbet Qeiyafa were analyzed by accelerator mass spectrometry (AMS) radiocarbon dating. Of these, four were halved and sent to two different laboratories to minimize laboratory bias. The dating of these samples is ~1000 BC. Khirbet Qeiyafa is currently the earliest known example of a fortified city in the Kingdom of Judah and contributes direct evidence to the heated debate on the biblical narrative relating to King David. Was he the real historical ruler of an urbanized state-level society in the early 10th century BC or was this level of social development reached only at the end of the 8th century BC? We can conclude that there were indeed fortified centers in the Davidic kingdom from the studies presented. In addition, the dating of Khirbet Qeiyafa has far-reaching implications for the entire Levant. The discovery of Cypriot pottery at the site connects the 14C datings to Cyprus and the renewal of maritime trade between the island and the mainland in the Iron Age. A stone temple model from Khirbet Qeiyafa, decorated with triglyphs and a recessed doorframe, points to an early date for the development of this typical royal architecture of the Iron Age Levant.
Resumo:
A marine reservoir correction database and on-line interface.
Radiocarbon 43:461-463
Resumo:
This paper presents a new series of AMS dates on ultrafiltered bone gelatin extracted from identified cutmarked or humanly-modified bones and teeth from the site of Abri Pataud, in the French Dordogne. The sequence of 32 new determinations provides a coherent and reliable chronology from the site's early Upper Palaeolithic levels 5-14, excavated by Hallam Movius. The results show that there were some problems with the previous series of dates, with many underestimating the real age. The new results, when calibrated and modelled using a Bayesian statistical method, allow detailed understanding of the pace of cultural changes within the Aurignacian I and II levels of the site, something not achievable before. In the future, the sequence of dates will allow wider comparison to similarly dated contexts elsewhere in Europe. High precision dating is only possible by using large suites of AMS dates from humanly-modified material within well understood archaeological sequences modelled using a Bayesian statistical method. © 2011.
Resumo:
The authors explore the arrival of the earliest Gravettian in north-west Europe, using new high precision radiocarbon dates for bone excavated at Maisieres-Canal in Belgium to define a short-lit^ed occupation around 33 000 years ago. The tanged points in that assemblage have parallels in British sites, including Goat's Hole (Paviland). This is the site of the famous ochred burial of a young adult male, confiisingly known as the 'Red Lady', notv dated to around 34 000 BP. The new results demonstrate that this British 'rich burial' and the Gravettian with tanged points may bebng to two different occupation horizons separated by a cold spell.
Resumo:
The paper presents the calibration of Fuji BAS-TR image plate (IP) response to high energy carbon ions of different charge states by employing an intense laser-driven ion source, which allowed access to carbon energies up to 270 MeV. The calibration method consists of employing a Thomson parabola spectrometer to separate and spectrally resolve different ion species, and a slotted CR-39 solid state detector overlayed onto an image plate for an absolute calibration of the IP signal. An empirical response function was obtained which can be reasonably extrapolated to higher ion energies. The experimental data also show that the IP response is independent of ion charge states.
Resumo:
Low-mass stars are highly interesting targets: we are able to detect planets in their habitable zones, and upcoming searches for biomarkers in exoplanet atmospheres will focus on low-mass star systems due to their ubiquity and proximity. We aim to develop an age-activity calibration for old low-mass stars, using wide binary systems consisting of an M or K dwarf and a white dwarf. The age of the system is determined by the WD cooling time plus its progenitor lifetime, yielding reliable ages in the regime >1 Gyr. For an exploratory sample of 7 systems where we have already derived ages, we propose to perform Chandra ACIS-S observations to determine the X-ray luminosities of the M dwarfs and correlate their stellar activity with age. We ask for a total observing time of 110 ks.
Resumo:
A new radiocarbon preparation facility was set up in 2010 at the Godwin Laboratory for Palaeoclimate Research, at the University of Cambridge. Samples are graphitized via hydrogen reduction on an iron powder catalyst before being sent to the Chrono Centre, Belfast, or the Australian National University for accelerator mass spectrometry (AMS) analysis. The experimental setup and procedure have recently been developed to investigate the potential for running small samples of foraminiferal carbonate. By analyzing background values of samples ranging from 0.04 to 0.6 mg C along with similar sized secondary standards, the setup and experimental procedures were optimized for small samples. “Background” modern 14C contamination has been minimized through careful selection of iron powder, and graphitization has been optimized through the use of “small volume” reactors, allowing samples containing as little as 0.08 mg C to be graphitized and accurately dated. Graphitization efficiency/fractionation is found not to be the main limitation on the analysis of samples smaller than 0.07 mg C, which rather depends primarily on AMS ion beam optics, suggesting further improvements in small sample analysis might yet be achieved with our methodology.
Resumo:
Ria deAveiro is a very complex shallow water coastal lagoon located on the northwest of Portugal. Important issues would be left unanswered without a good understanding of hydrodynamic and transport processes occurring in the lagoon. Calibration and validation of hydrodynamic, salt and heat transport models for Ria de Aveiro lagoon are presented. The calibration of the hydrodynamic model was performed adjusting the bottom friction coefficient, through the comparison between measured and predicted time series of sea surface elevation for 22 stations. Harmonic analysis was performed in order to evaluate the model's accuracy. To validate the hydrodynamic model measured and predicted SSE values were compared for 11 stations, as well as main flow direction velocities for 10 stations. The salt and heat transport models were calibrated comparing measured and predicted time series of salinity and water temperature for 7 stations, and the RMS of the difference between the series was determined. These models were validated comparing the model results with an independent field data set. The hydrodynamic and the salt and heat transport models for Ria de Aveiro were successfully calibrated and validated. They reproduce accurately the barotropic flows and can therefore adequately represent the salt and heat transport and the heat transfer processes occurring in Ria deAveiro.
Resumo:
In this article, we calibrate the Vasicek interest rate model under the risk neutral measure by learning the model parameters using Gaussian processes for machine learning regression. The calibration is done by maximizing the likelihood of zero coupon bond log prices, using mean and covariance functions computed analytically, as well as likelihood derivatives with respect to the parameters. The maximization method used is the conjugate gradients. The only prices needed for calibration are zero coupon bond prices and the parameters are directly obtained in the arbitrage free risk neutral measure.
Resumo:
Oceans - San Diego, 2013
Resumo:
This work presents an automatic calibration method for a vision based external underwater ground-truth positioning system. These systems are a relevant tool in benchmarking and assessing the quality of research in underwater robotics applications. A stereo vision system can in suitable environments such as test tanks or in clear water conditions provide accurate position with low cost and flexible operation. In this work we present a two step extrinsic camera parameter calibration procedure in order to reduce the setup time and provide accurate results. The proposed method uses a planar homography decomposition in order to determine the relative camera poses and the determination of vanishing points of detected lines in the image to obtain the global pose of the stereo rig in the reference frame. This method was applied to our external vision based ground-truth at the INESC TEC/Robotics test tank. Results are presented in comparison with an precise calibration performed using points obtained from an accurate 3D LIDAR modelling of the environment.
Resumo:
A new Ultra-High Vacuum (UHV) reflectance spectrometer was successfully designed, making use of a Janis Industries ST-400 sample cryostat, IR Labs bolometer, and Briiker IFS 66 v/S spectrometer. Two of the noteworthy features include an in situ gold evaporator and internal reference path, both of which allow for the experiment to progress with a completely undisturbed sample position. As tested, the system was designed to operate between 4.2 K and 325 K over a frequency range of 60 - 670 cm~^. This frequency range can easily be extended through the addition of appUcable detectors. Tests were performed on SrTiOa, a highly ionic incipient ferroelectric insulator with a well known reflectance. The presence and temperatmre dependence of the lowest frequency "soft" mode were measured, as was the presence of the other two infrared modes. During the structural phase transition from cubic to tetragonal perovskite, the splitting of the second phonon mode was also observed. All of the collected data indicate good agreement with previous measurements, with a minor discrepency between the actual and recorded sample temperatures.