945 resultados para quasiparticle alignment
Resumo:
"July 1967."
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
A novel class of nonlinear, visco-elastic rheologies has recently been developed by MUHLHAUS et al. (2002a, b). The theory was originally developed for the simulation of large deformation processes including folding and kinking in multi-layered visco-elastic rock. The orientation of the layer surfaces or slip planes in the context of crystallographic slip is determined by the normal vector the so-called director of these surfaces. Here the model (MUHLHAUS et al., 2002a, b) is generalized to include thermal effects; it is shown that in 2-D steady states the director is given by the gradient of the flow potential. The model is applied to anisotropic simple shear where the directors are initially parallel to the shear direction. The relative effects of textural hardening and thermal softening are demonstrated. We then turn to natural convection and compare the time evolution and approximately steady states of isotropic and anisotropic convection for a Rayleigh number Ra=5.64x10(5) for aspect ratios of the experimental domain of 1 and 2, respectively. The isotropic case has a simple steady-state solution, whereas in the orthotropic convection model patterns evolve continuously in the core of the convection cell, which makes only a near-steady condition possible. This near-steady state condition shows well aligned boundary layers, and the number of convection cells which develop appears to be reduced in the orthotropic case. At the moderate Rayleigh numbers explored here we found only minor influences in the change from aspect ratio one to two in the model domain.
Resumo:
Phakometric measurements of corneal and crystalline lens surface alignment are influenced by corneal asymmetry in which the corneal apex does not coincide with the limbal centre. The purpose of this study was to determine the horizontal separation (e) between these corneal landmarks. Measurements were made in 60 normal eyes (30 subjects) using the Orbscan Ilz corneal analysis workstation. Our results show that both corneal landmarks typically coincide, so that e = 0, but that inter-subject variations of about ±1 mm can be expected (so that the corneal apex may fall nasal or temporal to the visual axis). This suggests that no correction for corneal asymmetry is required when estimating average amounts of ocular alignment from samples of eyes but that the measurement of e is strongly recommended for measurements in individual eyes. © 2004 The College of Optometrists.
Resumo:
Measurements (autokeratometry, A-scan ultrasonography and video ophthalmophakometry) of ocular surface radii, axial separations and alignment were made in the horizontal meridian of nine emmetropes (aged 20-38 years) with relaxed (cycloplegia) and active accommodation (mean ± 95% confidence interval: 3.7 ± 1.1 D). The anterior chamber depth (-1.5 ± 0.3 D) and both crystalline lens surfaces (front 3.1 ± 0.8 D; rear 2.1 ± 0.6 D) contributed to dioptric vergence changes that accompany accommodation. Accommodation did not alter ocular surface alignment. Ocular misalignment in relaxed eyes is mainly because of eye rotation (5.7 ± 1.6° temporally) with small amounts of lens tilt (0.2 ± 0.8° temporally) and decentration (0.1 ± 0.1 mm nasally) but these results must be viewed with caution as we did not account for corneal asymmetry. Comparison of calculated and empirically derived coefficients (upon which ocular surface alignment calculations depend) revealed that negligible inherent errors arose from neglect of ocular surface asphericity, lens gradient refractive index properties, surface astigmatism, effects of pupil size and centration, assumed eye rotation axis position and use of linear equations for analysing Purkinje image shifts. © 2004 The College of Optometrists.
Resumo:
Ophthalmophakometric measurements of ocular surface radius of curvature and alignment were evaluated on physical model eyes encompassing a wide range of human ocular dimensions. The results indicated that defocus errors arising from imperfections in the ophthalmophakometer camera telecentricity and light source collimation were smaller than experimental errors. Reasonable estimates emerged for anterior lens surface radius of curvature (accuracy: 0.02–0.10 mm; precision 0.05–0.09 mm), posterior lens surface radius of curvature (accuracy: 0.10–0.55 mm; precision 0.06–0.20 mm), eye rotation (accuracy: 0.00–0.32°; precision 0.06–0.25°), lens tilt (accuracy: 0.00–0.33°; precision 0.05–0.98°) and lens decentration (accuracy: 0.00–0.07 mm; precision 0.00–0.07 mm).
Resumo:
We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (β) together with crystalline lens axis tilt (α) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (β < 0.67°, α < 0.72° and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean ± S.D.: β = 6.2 ± 3.4° temporal, α = 0.2 ± 1.8° temporal and d = 0.1 ± 0.1 mm temporal) and repeatability (1.96 × S.D. of difference between repeat readings: β ± 2.0°, α ± 1.8° and d ± 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions. © 2005 The College of Optometrists.
Resumo:
We examined the effect of grouping by the alignment of implicit axes on the perception of multiple shapes, using a patient (GK) who shows simultanagnosia as part of Blint's syndrome. Five experiments demonstrated that: (1) GK was better able to judge the orientation of a global configuration if the constituent local shapes were aligned with their major axes than if they were aligned with their edges; (2) this axis information was used implicitly, since GK was unable to discriminate between configurations of axis-aligned and edge-aligned shapes; (3) GK's sensitivity to axis-alignment persisted even when the orientations of local shapes were kept constant, indicating some form of cooperative effect between the local elements; (4) axis-alignment of shapes also facilitated his ability to discriminate single-item from multi-item configurations; (5) the effect of axis-alignment could be attributed, at least partially, to the degree to which there was matching between the orientations of local shapes and the global configuration. Taken together, the results suggest that axis-based grouping can support the selection of multiple objects.
Resumo:
Information systems are corporate resources, therefore information systems development must be aligned with corporate strategy. This thesis proposes that effective strategic alignment of information systems requires information systems development, information systems planning and strategic management to be united. Literature in these areas is examined, breaching the academic boundaries which separate these areas, to contribute a synthesised approach to the strategic alignment of information systems development. Previous work in information systems planning has extended information systems development techniques, such as data modelling, into strategic planning activities, neglecting techniques of strategic management. Examination of strategic management in this thesis, identifies parallel trends in strategic management and information systems development; the premises of the learning school of strategic management are similar to those of soft systems approaches to information systems development. It is therefore proposed that strategic management can be supported by a soft systems approach. Strategic management tools and techniques frame individual views of a strategic situation; soft systems approaches can integrate these diverse views to explore the internal and external environments of an organisation. The information derived from strategic analysis justifies the need for an information system and provides a starting point for information systems development. This is demonstrated by a composite framework which enables each information system to be justified according to its direct contribution to corporate strategy. The proposed framework was developed through action research conducted in a number of organisations of varying types. This suggests that the framework can be widely used to support the strategic alignment of information systems development, thereby contributing to organisational success.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
Dynamic supply chain alignment: a new business model for peak performance in enterprise supply chains across all geographies John Gattorna and friends, Farnham, Gower Publishing, 2009, 440pp., £60, ISBN 978-0-566-08822-3.