924 resultados para power factor correction


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the comparison of three topologies of multilevel inverters applied to drive an induction motor of 500 kVA/4.16 kV. The multilevel inverters analyzed are: a neutral point clamped inverter, a symmetrical cascaded multilevel inverter and a hybrid asymmetrical cascaded multilevel inverter. The performance indexes used in the comparison are total harmonic distortion, first order distortion factor, semiconductors power losses distribution and heat-sink volume. The comparison is developed with the purpose of finding the efficiency and the heat-sink volume where the three systems present the same output filter. ©2008 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents evaluations among the most usual MPPT techniques, doing meaningful comparisons with respect to the amount of energy extracted from the photovoltaic panel (PV) (Tracking Factor - TF) in relation to the available power, PV voltage ripple, dynamic response and use of sensors. Using MatLab/Simulink® and DSpace platforms, a digitally controlled boost DC-DC converter was implemented and connected to an Agilent Solar Array E4350B simulator in order to verify the analytical procedures. The main experimental results are presented and a contribution in the implementation of the IC algorithm is performed and called IC based on PI. Moreover, the dynamic response and the tracking factor are also evaluated using a Friendly User Interface, which is capable of online program power curves and compute the TF. Finally, a typical daily insulation is used in order to verify the experimental results for the main PV MPPT methods. © 2011 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a power system capacity expansion planning modelconsidering carbon emissions constraints. In addition to the traditionaltechnical and economical issues usually considered in the planning process, two environmental policies that consist on the taxation and the annual limitsof carbon dioxide (CO 2) emissions are considered. Furthermore, the gradualretirement of old inefficient generation plants has been included. The approachguarantees a cleaner electricity production in the expanded power system ata relatively low cost. The proposed model considers the transmission systemand is applied to a 4-region and 11-region power systems over a 20-yearplanning horizon. Results show practical investment decisions in terms of sustainability and costs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents efficient geometric parameterization techniques using the tangent and the trivial predictors for the continuation power flow, developed from observation of the trajectories of the load flow solution. The parameterization technique eliminates the Jacobian matrix singularity of load flow, and therefore all the consequent problems of ill-conditioning, by the addition of the line equations which pass through the points in the plane determined by the variables loading factor and the real power generated by the slack bus, two parameters with clear physical meaning. This paper also provides an automatic step size control around the maximum loading point. Thus, the resulting method enables not only the calculation of the maximum loading point, but also the complete tracing of P-V curves of electric power systems. The technique combines robustness with ease of understanding. The results to the IEEE 300-bus system and of large real systems show the effectiveness of the proposed method. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Macrophage migration inhibitory factor (MIF) is a pleiotropic cytokine with pro-inflammatory functions and involved in tumorigenesis. The aim of this study was to evaluate the expression and localization of the macrophage MIF in oral squamous carcinoma (OSC). In addition, the relationship between MIF expression and clinicopathological parameters such as survival data, tobacco use, alcohol habits, TNM stage, tumor graduation, and peritumoral inflammatory infiltrate were evaluated. Methods: Using immunohistochemistry, expression and localization of MIF was detected in 44 specimens of OSC. The absolute number and relative proportions of MIF-positive cells detected were also determined separately for tumor parenchyma vs. stroma. All counts were determined from 10 consecutive high-power fields using an integration graticule. Moreover, some parameters were analyzed separately for lip and intra-oral cancers. Results: Migration inhibitory factor-positive cells were observed in both the tumor parenchyma and in inflammatory cells of all specimens. In contrast, MIF expression was not detected in tumoral nests associated with poorly differentiated tumors. In specimens of lip cancer, a greater number of MIF-positive stromal immune cells were detected than in intra-oral cancer specimens (Mann-Whitney test, P = 0.049). Conclusions: Oral squamous carcinoma cells consistently express MIF independent of their location. Lip tumors presented more MIF-positive peritumoral inflammatory cells, similar to control, suggesting that immunological differences in leukocyte activation exist between in lip and intra-oral cancers. © 2012 John Wiley & Sons A/S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article applies the stochastic-frontier model to examine total factor productivity (tfp) and its components in Latin America between 1960 and 2010. The likelihood-ratio test shows that, for a selection of Latin American countries over the 50 years analysed, the macroeconomic variables of technical inefficiency included in the model generally have a significant effect; and they allow for a better understanding of technical inefficiency throughout the region. The key variables explaining technical inefficiency in the selected countries are public expenditure and the inflation rate; and there is also an inverse relation between technical inefficiency and the extent to which local prices diverge from purchasing power parity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the optimal reactive power planning problem under risk is presented. The classical mixed-integer nonlinear model for reactive power planning is expanded into two stage stochastic model considering risk. This new model considers uncertainty on the demand load. The risk is quantified by a factor introduced into the objective function and is identified as the variance of the random variables. Finally numerical results illustrate the performance of the proposed model, that is applied to IEEE 30-bus test system to determine optimal amount and location for reactive power expansion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Power-counting arguments are used to organize the interactions contributing to the NN-->d pi,pn pi reactions near threshold. We estimate the contributions from the three formally leading mechanisms: the Weinberg-Tomozawa (WT) term, the impulse term, and the Delta-excitation mechanism. Subleading but potentially large mechanisms, including S-wave pion rescattering, the Galilean correction to the WT term, and short-ranged contributions are also examined. The WT term is shown to be numerically the largest, and the other contributions are found to approximately cancel. Similarly to the reaction pp-->pp pi(0), the computed cross sections are considerably smaller than the data. We discuss possible origins of this discrepancy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents the application of Linear Matrix Inequalities to the robust and optimal adjustment of Power System Stabilizers with pre-defined structure. Results of some tests show that gain and zeros adjustments are sufficient to guarantee robust stability and performance with respect to various operating points. Making use of the flexible structure of LMI's, we propose an algorithm that minimizes the norm of the controllers gain matrix while it guarantees the damping factor specified for the closed loop system, always using a controller with flexible structure. The technique used here is the pole placement, whose objective is to place the poles of the closed loop system in a specific region of the complex plane. Results of tests with a nine-machine system are presented and discussed, in order to validate the algorithm proposed. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The saccadic paradigm has been used to investigate specific cortical networks involving attention. The behavioral and electrophysiological investigations of the SEM contribute significantly to the understanding of attentive patterns presented of neurological and psychiatric disorders and sports performance. Objective: The current study aimed to investigate absolute alpha power changes in sensorimotor brain regions and the frontal eye fields during the execution of a saccadic task. Methods: Twelve healthy volunteers (mean age: 26.25; SD: +/- 4.13) performed a saccadic task while the electroencephalographic signal was simultaneously recorded for the cerebral cortex electrodes. The participants were instructed to follow the LEDs with their eyes, being submitted to two different task conditions: a fixed pattern versus a random pattern. Results: We found a moment main effect for the C3, C4, F3 and F4 electrodes and a condition main effect for the F3 electrode. We also found interaction between factor conditions and frontal electrodes. Conclusions: We conclude that absolute alpha power in the left frontal cortex discriminates the execution of the two stimulus presentation patterns during SEM. (C) 2012 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new measurement of the B-11(p,alpha(0))Be-8 has been performed applying the Trojan horse method (THM) to the H-2(B-11,alpha Be-8(0))n quasi-free reaction induced at a laboratory energy of 27 MeV. The astrophysical S(E) factor has been extracted from similar to 600 keV down to zero energy by means of an improved data analysis technique and it has been compared with direct data available in the literature. The range investigated here overlaps with the energy region of the light element LiBeB stellar burning and with that of future aneutronic fusion power plants using the B-11+p fuel cycle. The new investigation described here confirms the preliminary results obtained in the recent TH works. The origin of the discrepancy between the direct estimate of the B-11(p,alpha(0))Be-8 S(E)-factor at zero energy and that from a previous THM investigation is quantitatively corroborated. The results obtained here support, within the experimental uncertainties, the low-energy S(E)-factor extrapolation and the value of the electron screening potential deduced from direct measurements.