942 resultados para polyester prosthesis
Resumo:
OBJECTIVE: To describe a surgical procedure utilizing a malleable bovine pericardium ring in mitral valve repair and clinical and echodopplercadiographic results. METHODS: Thirty-two (25 female and 7 male) patients, aged between 9 and 66 (M=36.4±17.2) years, were studied over a 16-month period, with 100% follow-up. In 23 (72%) of the patients, the mitral approach was the only one applied; 9 patients underwent associated operations. The technique applied consisted of measuring the perimeter of the anterior leaflet and implanting, according to this measurement, a flexible bovine pericardium prosthesis for reinforcement and conformation of the posterior mitral annulus, reducing it to the perimeter of the anterior leaflet with adjustment of the valve apparatus. RESULTS: The patient survival ratio was 93.8%, with 2 (6.2%) fatal outcomes, one from unknown causes, the other due to left ventricular failure. Only one reoperation was performed. On echodopplercardiography, 88% of the patients had functional recovery of the mitral valve (50% without and 38% with mild insufficiency and no hemodynamic repercussions). Of four (12%) of the remaining patients, 6% had moderate and 6% had seigre insufficiency. Twenty-eight percent of class II patients and 72% of class III patients passed into classes I (65%), II (32%), and III (3%), according to NYHA classification criteria. CONCLUSION: Being flexible, the bovine pericardium ring fit perfectly into the valve annulus, taking into account its geometry and contractility. Valve repair was shown to be reproducible, demonstrating significant advantages during patient evolution, which did not require anticoagulation measures.
Resumo:
Dissertação de mestrado em Técnicas de Caraterização e Análise Química
Resumo:
OBJECTIVE: Our aim was to compare, in a non randomized study, the surgical outcome in elderly patients with mechanical (Group 1; n=83) and bioprosthetic valve implants (Group 2; n=136). METHODS: During a three year period, 219 patients >75 years underwent Aortic Valve Replacement. The groups matched according to age, sex, comorbidity, valve pathology and concomitant Coronary Artery Bypass Surgery. Follow-up was a total of 469 patient-years (mean follow-up 2.1 years, maximum 4,4 years). RESULTS: Operative mortality was zero and the overall early mortality was 2.3 % (within 30 days). Actuarial survival was 87.5 ± 4.0% and 66.1 ± 7.7% (NS) at 4 years in Group 1 and Group 2, respectively. Freedom from valve-related death was 88.9 ± 3.8% in Group 1 and 69.9±7.9% (NS) in Group 2 at 4 years. CONCLUSION: Aortic Valve Replacement in the elderly (>75 years) is a safe procedure even in cases where concomitant coronary artery revascularization is performed. Only a few anticoagulant-related complications were reported and this may indicate that selected groups of elderly patients with significant life expectancy may benefit from mechanical implants .
Resumo:
OBJECTIVE: This study evaluated the effects of a new method of mitral valve replacement on left ventricular (LV) remodeling and heart failure functional class. METHODS: Eight patients (6 men) with severe mitral regurgitation from end-stage dilated cardiomyopathy underwent surgery. Five patients were in functional class (FC) IV, 2 were in FC III and 1 was in FC III/IV. Age ranged from 33 to 63 years. Both the anterior and posterior leaflets of the mitral valve were divided into hemileaflets. The resultant 4 pedicles were displaced under traction toward the left atrium and anchored between the mitral annulus and an implanted valvular prosthesis. The beating heart facilitated ideal chordae tendineae positioning. RESULTS: All patients survived and were discharged from the hospital. After a mean follow-up period of 6.5 months (1-12 m), 5 patients were in FC I; 2 in FC I/II; and 1 in FC II. The preoperative ejection fraction ranged from 19% to 30% (mean: 25.7±3.4 %), and the postoperative ejection fraction ranged from 21% to 40% (mean: 31.1± 5.8%). Doppler echocardiography showed evidence of LV remodeling in 4 patients, including lateral wall changes and a tendency of the LV cavity to return to its elliptical shape. CONCLUSION: This technique of mitral valve replacement, involving new positioning of the chordae tendineae, allowed LV remodeling and improvement in FC during this brief follow-up period.
Resumo:
OBJECTIVE: To assess the occurrence of late thromboembolism after surgical repair of chronic atrial fibrillation (AF) simultaneously with repair of mitral valve using the Cox-Maze procedure. METHODS: 69 patients underwent Cox 3 procedure, with no cryoablation simultaneously with mitral valvuloplasty or prosthesis. Mean age was 49.9±13.2 years. Mean follow-up was of 31.7±19 months. Types of lesion were as follows: 33 (48%) stenoses, 23 (33%) insufficiencies, and 13 (19%) double lesions. Procedures were: 64 (93%) valvuloplasties, 3 (4%) biological and 2 (3%) mechanical prosthesis placement. There were 9 (13%) patients with previous systemic embolism and 2 (3%) had left atrial thrombi. RESULTS: Early mortality was 7% and late 1%. 2 patients (3%) were reoperated for mitral placement. At last evaluation, 10 patients (15%), were in AF. The remaining 59 (85%) were either in sinus / atrial rythm (74%) or under pacing (12%). There were no occurrence of early or late, systemic or pulmonary embolism. Permanent anticoagulation was employed in 16 cases, 10 in regular rythm and 6 in AF. The remaining 47 (75%), 2 in AF and 45 in regular rythm, did not receive anticoagulants. CONCLUSIONS: These results are in accordance with others series, where the occurrence of embolism was rare after maze procedure. Permanent systemic anticoagulation seems to be unnecessary in those cases.
Resumo:
PhD in Sciences Specialty in Physics
Resumo:
We report the case of implantation of metallic mitral and aortic valve prostheses 6 months earlier, with subsequent multiple embolic episodes. The anatomicopathological examination of the thrombus of the third embolic episode was compatible with Aspergillus sp, which was treated with amphotericin B, followed by oral itraconazole. On the fourth embolism, vegetations were visualized in the ascending aorta on echocardiography and resonance imaging, and the patient underwent replacement of the aortic segment by a Haemashield tube and exploration of the aortic prosthesis, which was preserved, because no signs of endocarditis were found. Four months later, the patient died due to cardiogenic shock secondary to acute myocardial infarction caused by probable coronary embolism and partial dysfunction of the aortic prosthesis.
Resumo:
OBJECTIVE: One of the most exciting potential applications of percutaneous therapy is the treatment of abdominal aneurysms. METHODS: Of 230 patients treated with a self-expanding polyester-lined stent-graft for different aortic pathologies at our institution, we selected 80 abdominal aneurysm cases undergoing treatment (from May 1997 to December 2002). The stent was introduced through the femoral artery, in the hemodynamic laboratory, with the patient under general anesthesia, with systemic heparinization, and induced hypotension. RESULTS: The procedure was successful in 70 (92.9%) cases; 10 patients with exclusion of abdominal aortic aneurysms were documented immediately within the hemodynamic room and 5 patients persisted with a residual leak. Two surgical conversions were necessary. Additional stent-grafts had to be inserted in 3 (3.7%) cases. In the follow-up, 91.4% of patients were alive at a mean follow-up of 15.8 months. CONCLUSION: We believe that stent-grafts are an important tool in improving the treatment of abdominal aneurysms, and this new policy may change the conventional medical management of these patients.
Resumo:
Abdominal Aortic Aneurysms (AAA) haemorhaging is a life-threatening disease. An aneurysm is a permanent swelling of an artery due to a weakness in its wall. Current surgical repair involves opening the chest or abdomen, gaining temporary vascular control of the aorta and suturing a prosthetic graft to the healthy aorta within the aneurysm itself The outcome of this surgical approach is not perfect, and the quality of life after this repair is impaired by postoperative pain, sexual dysfunction, and a lengthy hospital stay resulting in high health costs. All these negative effects are related to the large incision and extensive tissue dissection. Endovascular grafting is an alternative to the standard surgical method. This treatment is a less invasive method of treating aortic aneurysms. It involves a surgical exposure of the common femoral arteries where the stent graft can be inserted through by an over-the-wire technique. All manipulations are controlled from a remote place by the use of a catheter and this technique avoids the need to directly expose the diseased artery through a large incision or an extensive dissection. The proposed design method outlined in this project is to develop the endovascular approach. The main aim is to design an unitary bifurcated stent graft (1 e- bifurcated graft as a single component) to treat these Abdominal Aortic Aneurysms. This includes the delivery system and deployment mechanism necessary to first accurately position the stent graft across the aneurysm sac and also across the iliac bifurcation, and secondly fix the stent graft in position by using expandable metal stents. Thus, excluding the aneurysm from the circulation and therefore preventing rupture. Miniaturisation is a critical aspect of this design, as the smaller the crimped stent graft the easier to guide through the vascular system to the desired location. Biocompatibility is an important aspect. The preferred materials for this prosthesis are to use Shape Memory Alloys for the stent and a multifilament fabric for the graft. A taper design is applied for the geometry as this gives a favourable flow characteristic and reduced wave reflections. Adequate testing of the stent graft to prove its durability and the ease of the method of deployment is a prerequisite. A bench test facility has being designed and build to replicate the cardiovascular system and the disease in question aortic aneurysms at the iliac bifurcation. The testing here shows the feasibility of the proposed delivery system and the durability of the stent graft across the aneurysm sac. Finally, these endovascular treatments offer the economic advantage of short hospital stays or even treatment as an outpatient, as well as elimination of the need for postoperative intensive care The risk of developing an aneurysm increases with age, that is one of the mam reasons to look for less invasive ways of treating aneurysms. Consequently, there is enormous pressure to develop and use these devices rapidly.
Resumo:
Background: Conventional surgical repair of thoracic aortic dissections is a challenge due to mortality and morbidity risks. Objectives: We analyzed our experience in hybrid aortic arch repair for complex dissections of the aortic arch. Methods: Between 2009 and 2013, 18 patients (the mean age of 67 ± 8 years-old) underwent hybrid aortic arch repair. The procedural strategy was determined on the individual patient. Results: Thirteen patients had type I repair using trifurcation and another patient with bifurcation graft. Two patients had type II repair with replacement of the ascending aorta. Two patients received extra-anatomic bypass grafting to left carotid artery allowing covering of zone 1. Stent graft deployment rate was 100%. No patients experienced stroke. One patient with total debranching of the aortic arch following an acute dissection of the proximal arch expired 3 months after TEVAR due to heart failure. There were no early to midterm endoleaks. The median follow-up was 20 ± 8 months with patency rate of 100%. Conclusion: Various debranching solutions for different complex scenarios of the aortic arch serve as less invasive procedures than conventional open surgery enabling safe and effective treatment of this highly selected subgroup of patients with complex aortic pathologies.
Resumo:
Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.
Resumo:
The PulseCath iVAC 3L? left ventricular assist device is an option to treat transitory left heart failure or dysfunction post-cardiac surgery. Assisted blood flow should reach up to 3 l/min. In the present in vitro model exact pump flow, depending on various frequencies and afterload was examined. Optimal flow was achieved with inflation/deflation frequencies of about 70-80/min. The maximal flow rate was achieved at about 2.5 l/min with a minimal afterload of 22 mmHg. Handling of the device was easy due to the connection to a standard intra-aortic balloon pump console. With increasing afterload (up to a simulated mean systemic pressure of 66 mmHg) flow rate and cardiac support are in some extent limited.