848 resultados para otimização


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Upper canines impaction are considered the second most frequent and are associated to important esthetics and functional limitations. Among the treatment strategies described in the literature the most commonly used are the extraction of the primary canines and the surgical exposure followed by orthodontic traction, that requires an adequate interdisciplinary approach. The aim of this case report is to draw the attention of the clinician to the possibility of adapting the segmented arch technique to manage a canine impaction clinical case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2001, it was estimated that pesticide used worldwide exceeded 2.27 billion kilograms, over 35%, of which, were herbicides. Brazil is considered one of the leaders in the production of sugarcane and mainly ethanol as fuel. The monoculture of sugarcane requires the usage of a range of pesticides, among these, the herbicides diuron and tebuthiuron. The degradation products most studied (DCA and DCPU) are diuron's, especially for toxicological characteristics of this herbicide that is identified as carcinogen and suspected to be endocrine disruptor in mammals. After optimization of the chromatographic separation using HPLC-UV, the analytical curve was constructed in solvent and subsequently in the matrix (surface water). The extraction method contains the usage of SPE (solid phase extraction) (Strata-X, 200 mg/6 mL), applicating 1L of sample and elution with 5 mL of acetonitrile / methanol (50:50, v/v). Analysis by HPLC/UV was performed in gradient mode, acetonitrile/water (70/30-74/26 by 1 min, 74/26 - 78/22 till 3.2 min, returning to initial conditions and remaining this way until 10 min), 018 column (Phenomenex, 4.6 mm diameter, 250 mm long and 5pm particle size) and detection at 254 nm. Tests F and t were performed to verify the presence of the matrix effect. There was matrix effect to all analytes, ranging from -33% (DCA) and 38% (tebuthiuron). Thereby the method was optimized and validated for analysis of diuron, tebuthiuron, and DCPU DCA in surface water using HPLC/UV. The data obtained show that in order to assure the analytical reliability desired the use of the analytical curves in the matrix for the quantification of these analytes in water is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes instrumental strategies for the determination of Mn in a wide range concentration by high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS F AAS) by means of different atomic lines (primary at 279.482 nm, secondary at 403.075 nm and alternative at 209.250 nm). These lines provided complementary concentration intervals, and large sample dilutions became unnecessary. The proposed method was applied to tap water, metal alloy certified material and foliar fertilizer. Accuracy for secondary line were evaluated by tests of significance (t Student test) with reference materials from the Institute of Technological Research of São Paulo, and the results were in agreement at the 95% confidence level. For primary and alternative lines, recovery is were in the 84-116% range and the RSD were 6.1% for all wavelengths. Analytical curves in the 0.1 - 2.0 mg L-1 (279.482 nm), 2.0 - 25 mg L-1 (403.075 nm), 25 - 500 mg L-1 (209.250 nm) intervals were obtained with linear correlation coefficient better than 0.9991. The detection limits were 3.3x10-3 mg L-1 (279.482 nm), 7.4 x 10-3 mg L-1 (403.075 nm), 3.9 mg L- 1 (209.250 nm). The found Mn concentrations were < 3.3x10-3 mg L-1 (tap water), 1.00 ± 0.04 (% m/m) (alloy IPT 25), 7235 ± 175 mg L-1 (foliar fertilizer 1), 4990 ± 132 mg L-1 (foliar fertilizer 2). A method was developed to detect interference of Fe in the Mn primary line (279.482 nm) using the ratio of absorbances of other lines of the triplet (279.827 nm and 280,108 nm).