928 resultados para musiikkivideot - Thru The Wire
Resumo:
In some applications like fault analysis, fault location, power quality studies, safety analysis, loss analysis, etc., knowing the neutral wire and ground currents and voltages could be of particular interest. In order to investigate effects of neutrals and system grounding on the operation of the distribution feeders with faults, in this research a hybrid short circuit algorithm is generalized. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. Results obtained from several case studies using IEEE 34-node test network are presented and discussed.
Resumo:
An 8051-based microcontroller tester has been designed to reduce troubleshooting time of the Electro-Hydraulic Actuators (EHA) installed in fly-by-wire aircrafts. The tester algorithm first evaluates EHA pressure and position sensor signals to emit either a pass or fail message. The evaluation is based on predefined ranges of EHA pressure and position signals. Next, the instrument tests the EHA response capability - a way of dynamic response evaluation, again issuing a suitable response. The instrument proved to be reliable after being successfully evaluated in laboratory and in a real model test airplane. © 2007 IEEE.
Resumo:
Aim: Treatment of periodontal diseases is based on efficient scaling and root planing (SRP) and adequate maintenance of the patient. The effectiveness of SRP is influenced by operator skill, access to the subgingival area, root anatomy, and the quality and type of instrument used for SRP. The aim of this study was to evaluate the cutting edges of Gracey curettes after manufacturing and after resharpening using several techniques. Methods and Material: The cutting edges of a total of 41 new #5-6 stainless steel Gracey curettes were evaluated blindly using scanning electron microscopy (SEM). The quality of the cutting edges was evaluated blindly by a calibrated examiner using micrographs. Data were analyzed using a Kruskal Wallis test and nonparametric two-way multiple comparisons. Results and Conclusions: Different sharpening techniques had significantly different effects on the sharpeness of cutting edges (p<0.05). Sharpening by passing the lateral face of curettes over a sharpening stone and then a #299 Arkansas stone produced a high frequency of smooth, sharp edges or slightly irregular edges between the lateral and coronal faces of the curettes. Sharpening by passing a blunt stone over the curette's lateral face produced the poorest quality cutting edge (a bevel). Sharpening of the coronal curette face produced extremely irregular cutting edges and non-functional wire edges. Sharpening with rotary devices produced extremely irregular cutting edges.
Resumo:
This paper investigates the major similarities and discrepancies of three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what seems to be done by means of the CPT. © 2009 IEEE.
Resumo:
This paper investigates the major similarities and discrepancies among three important current decompositions proposed for the interpretation of unbalanced and/or non linear three-phase four-wire power circuits. The considered approaches were the so-called FBD Theory, the pq-Theory and the CPT. Although the methods are based on different concepts, the results obtained under ideal conditions (sinusoidal and balanced signals) are very similar. The main differences appear in the presence of unbalanced and non linear load conditions. It will be demonstrated and discussed how the choice of the voltage referential and the return conductor impedance can influence in the resulting current components, as well as, the way of interpreting a power circuit with return conductor. Under linear unbalanced conditions, both FBD and pq-Theory suggest that the some current components contain a third-order harmonic. Besides, neither pq-Theory nor FBD method are able to provide accurate information for reactive current under unbalanced and distorted conditions, what can be done by means of the CPT. © 2009 IEEE.
Resumo:
This article describes an orthodontic system used to obtain active continuous torque with movement control of both active and reactive units; the system relies on principles of the segmented technique. A cantilever system with .017 x .025-in beta-titanium alloy wire was designed to provide the desirable moment on the active unit. A transpalatal bar or a lingual arch increases the anchorage and neutralizes the side effects on the reactive unit. This technique is an efficient approach for major corrections of buccolingual inclinations of certain teeth. © 2010 American Association of Orthodontists.
Resumo:
In order to contribute to the discussion of defining a generalized power theory, valid for unbalanced and non linear circuits, this paper discusses the relationship and discrepancies among four modern power theories. Three-phase four-wire circuits, under different conditions, have been analyzed, since the most conflicting and intriguing interpretations take place in case of return conductor occurrence. Simulation results of different load, power supply and line conditions will be discussed in order to elucidate the author's conclusions and to provoke the readers for additional discussions. © 2010 IEEE.
Resumo:
Unbalance and harmonics are two major distortions in the three-phase distribution systems. In this paper an investigation into unbalance phenomena in the distribution networks using instantaneous space vector theory, is presented. Power oscillation index (POI) and effective power factor (PFe) are calculated in the network nodes for several unbalance loading conditions. For system analysis a general power flow algorithm for three-phase four-wire radial distribution networks, based on backward-forward technique, is applied. Results obtained from several case studies using medium and low voltage test feeder with unbalanced load, are presented and discussed. © 2010 Praise Worthy Prize S.r.l. - All rights reserved.
Resumo:
Objective: To analyze the effects of thermal cycling on the microtensile shear bond strength of a self-etching and a conventional pit and fissure sealants to dental enamel. Material and Method: Twenty-four healthy human molars extracted for orthodontic reasons, were sectioned in the mesio-distal direction and divided into two groups (n=24) according to the sealant to be applied: GI - conventional sealant Climpro (3M/ESPE) and GII - self-etching sealant Enamel Loc (Premier Dental). The sealants were applied on flattened enamel in matrixes 1 mm in diameter, in accordance with the manufacturers' recommendations. The specimens were stored in distilled water at 37°C for 24 hours. After this, half the samples of both groups were submitted to 500 thermal cycles in 30s baths at temperatures between 5 and 55°C. Forty-eight hours after the samples were made, the microtensile shear test was performed in an Instron 4411 test machine, with a stainless steel wire with a cylindrical cross section of 0.2mm in diameter at a constant speed of 0.5mm/s. The bond strength values were submitted to ANOVA for 2 factors and the fracture patterns were examined under an optical microscope at 65X magnification. Results: Thermal cycling did not influence the bond strength of the two sealants. The conventional sealant Climpro presented a statistically higher microtensile shear bond strength (11.72MPa, 11.34MPa with and without cycling, respectively) than the self-etching sealant Enamel Loc (5.92MPa, 5.02MPa with and without cycling, respectively). Fracture pattern analysis showed the occurrence of 100% of adhesive failures for Enamel Loc, while the conventional sealant Climpro presented 95% of adhesive failures and 5% of mixed failures. Conclusion: The conventional sealant presented higher microtensile shear bond strength to dental enamel in comparison with the self-etching sealant. Thermal cycling did not affect the bond strength of the sealants used in this study. © 2011 Nova Science Publishers, Inc.
Resumo:
This paper presents some methodologies for reactive energy measurement, considering three modern power theories that are suitable for three-phase four-wire non-sinusoidal and unbalanced circuits. The theories were applied in some profiles collected in electrical distribution systems which have real characteristics for voltages and currents measured by commercial reactive energy meters. The experimental results are presented in order to analyze the accuracy of the methodologies, considering the standard IEEE 1459-2010 as a reference. Finally, for additional comparisons, the theories will be confronted with the modern Yokogawa WT3000 energy meter and three samples of a commercial energy meter through an experimental setup. © 2011 IEEE.
Resumo:
Considering the operation of shunt active compensators, such as active power filters, this paper proposes possible compensation strategies by means of the recent formulation of the Conservative Power Theory (CPT). The CPT current's decomposition results in several current components, which are associated with specific load characteristics (power transfer, energy storage, unbalances and/or non linearities). These current components are used for the definition of different compensation strategies, which can be selective in terms of minimizing particular disturbing effects. In order to validate the applicability of these new compensation strategies, simulation and experimental results for three-phase four-wire systems are presented. © 2011 IEEE.
Resumo:
The interpretation of the set of radiographs taken during the follow-up period after tooth replantation might pose several difficulties, especially the inability to adequately reproduce the projection geometry of the exposures. This article describes a method for the geometric standardization of intraoral radiographs using a custom-made apparatus comprising a film-holder attached to an occlusal splint for the long-term follow up of dentoalveolar trauma. The method was applied in a patient who suffered an avulsion of the maxillary central incisors and had the teeth replanted after 4 h in saline storage. Endodontic treatment started 7 days after the trauma with changes of a calcium hydroxide intracanal medication every 15 days in the first 2 months and thereafter at 30-day intervals for 8 months. Root canal filling was carried out after this period. The radiographic exposures taken at the follow-up visits were standardized to identify the possible alterations during the repair process, such as root resorptions. A maxillary arch impression was made with alginate, and the model was cast in stone for fabrication of an acetate occlusal splint. The custom-made apparatus used for standardization of the radiographic exposures was fabricated by fixing a Rinn X-C-P film-holder and a 5-mm-long piece of 0.7-mm orthodontic wire to the occlusal splint with autopolymerized acrylic resin. Radiographs were taken at 4-month intervals, starting 10 months after replantation up to 76 months. The images were digitized and analysed using the Digora system. The length of the central incisors was determined to verify the reproduction of the projection geometry of the exposures and the orthodontic wire served to assess accuracy during length estimations in the radiographs. The method described in this article for geometric standardization of intraoral radiographs provided a consistent reproduction of the geometric exposure parameters, being indicated for use in the radiographic follow up of cases of dentoalveolar trauma. © 2012 John Wiley & Sons A/S.
Resumo:
Based on the framework of the Conservative Power Theory (CPT), this paper proposes some compensation strategies for shunt current compensators. CPT current decompositions result in several current-related terms associated with specific load characteristics, such as power consumption, energy storage, unbalances and load nonlinearities. These current components are decoupled (orthogonal) from each other and are used here to define different compensation strategies, which can be selective in minimizing particular effects of disturbing loads. Compensation strategies for single- and three-phase four-wire circuits are also considered. Simulated and experimental results are described to validate the possibilities and performance of the proposed strategies. © 2013 Brazilian Society for Automatics - SBA.
Resumo:
This study compared the effect of the treatment protocol for correcting Class Il malocclusion using the Herbst appliance followed by full fixed Straigh-wire mechanics, in two populations, one Brazilian and one of North American origin As a untreated control sample the data from the University of Michigan Elementary and Secondary School Growth Study (UMGS) was used. Our sample was composed of 12 males and 12 females, with initial mean age of 12 years 7 months and final mean ages of 15 years and 3 months. The Michigan patients comprised 21 females and 7 males, with an initial mean age of 11 years and 9 months and final mean age of 14 years and 4 months. The control sample was paired in number, sex and age to the treated Michigan sample. ln both treated groups, lateral cephalometric radiographs were obtained before the Herbst appliance was cemented and at the end of the fixed appliance phase, The first comparison involved the Brazil group and the untreated controls, which demonstrated that the association of the Herbst appliance followed by fixed Straight-wire appliances provoked positive effects on the dentofacial complex, improving pre-existing maxillo-mandibular relationships, besides increasing dentoalveolar compensations which contributed to correct the malocclusion. The second comparison, involved the Brazl1ian and North-American patients treated with the same protocol. Although the pre-treatment comparison showed that the two groups were not similar in all aspects, they presented almost identical therapeutic modifications, which indicate that the effect of' treatment was very similar. These results point out that, in Class ll treatment, the combination of Herbst/Straight-wire mechanics produce consistent and systematic effects, correcting or minimizing possible skeletal imbalances
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)