861 resultados para motion platform
Resumo:
Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.
Resumo:
In the era of fast product development and customized product requirements, the concept of product platform has proven its power in practice. The product platform approach has enabledcompanies to increase the speed of product introductions while simultaneously benefit from efficiency and effectiveness in the development and production activities. The product platforms are technological bases, which can be used to develop several derivative products, and hence, the differentiation can be pushed closer to the product introduction. The product platform development has some specific features, which differ somewhat from the product development of single products. The time horizon is longer, since the product platform¿slife cycle is longer than individual product's. The long time-horizon also proposes higher market risks and the use of new technologies increases the technological risks involved. The end-customer interface might be far away, but there is not a lack of needs aimed at the product platforms ¿ in fact, the product platform development is very much balancing between the varying needs set to it by thederivative products. This dissertation concentrated on product platform development from the internal product lines' perspective of a singlecase. Altogether six product platform development factors were identified: 'Strategic and business fit of product platform', 'Project communication and deliverables', 'Cooperation with product platform development', 'Innovativeness of product platform architecture and features', 'Reliability and quality of product platform', and 'Promised schedules and final product platform meeting the needs'. From the six factors, three were found to influence quite strongly the overall satisfaction, namely 'Strategic and business fit of product platform', 'Reliability and quality of product platform', and 'Promised schedules and final product platform meeting the needs'. Hence, these three factors might be the ones a new product platform development unit should concentrate first in order to satisfy their closest customers, the product lines. The 'Project communication and deliverables' and 'Innovativeness of product platform architecture and features' were weaker contributors to the overall satisfaction. Overall, the factors explained quite well the satisfaction of the product lines with product platform development. Along the research, several interesting aspects about the very basic nature of the product platform development were found. The long time horizon of the product platform development caused challenges in the area of strategic fIT - a conflict between the short-term requirements and long term needs. The fact that a product platform was used as basis of several derivative products resulted into varying needs, and hence the match with the needs and the strategies. The opinions, that the releases of the larger product lines were given higher priorities, give an interesting contribution to the strategy theory of powerand politics. The varying needs of the product lines, the strengths of them as well as large number of concurrent releases set requirements to prioritization. Hence, the research showed the complicated nature of the product platform development in the case unIT - the very basic nature of the product platform development might be its strength (gaining efficiency and effectiveness in product development and product launches) but also the biggest challenge (developing products to meet several needs). As a single case study, the results of this research are not directly generalizable to all the product platform development activities. Instead, the research serves best as a starting point for additional research as well as gives some insights about the factors and challengesof one product development unit.
Resumo:
High dynamic performance of an electric motor is a fundamental prerequisite in motion control applications, also known as servo drives. Recent developments in the field of microprocessors and power electronics have enabled faster and faster movements with an electric motor. In such a dynamically demanding application, the dimensioning of the motor differs substantially from the industrial motor design, where feasible characteristics of the motor are for example high efficiency, a high power factor, and a low price. In motion control instead, such characteristics as high overloading capability, high-speed operation, high torque density and low inertia are required. The thesis investigates how the dimensioning of a high-performance servomotor differs from the dimensioning of industrial motors. The two most common servomotor types are examined; an induction motor and apermanent magnet synchronous motor. The suitability of these two motor types indynamically demanding servo applications is assessed, and the design aspects that optimize the servo characteristics of the motors are analyzed. Operating characteristics of a high performance motor are studied, and some methods for improvements are suggested. The main focus is on the induction machine, which is frequently compared to the permanent magnet synchronous motor. A 4 kW prototype induction motor was designed and manufactured for the verification of the simulation results in the laboratory conditions. Also a dynamic simulation model for estimating the thermal behaviour of the induction motor in servo applications was constructed. The accuracy of the model was improved by coupling it with the electromagnetic motor model in order to take into account the variations in the motor electromagnetic characteristics due to the temperature rise.
Resumo:
Observers are often required to adjust actions with objects that change their speed. However, no evidence for a direct sense of acceleration has been found so far. Instead, observers seem to detect changes in velocity within a temporal window when confronted with motion in the frontal plane (2D motion). Furthermore, recent studies suggest that motion-in-depth is detected by tracking changes of position in depth. Therefore, in order to sense acceleration in depth a kind of second-order computation would have to be carried out by the visual system. In two experiments, we show that observers misperceive acceleration of head-on approaches at least within the ranges we used [600-800 ms] resulting in an overestimation of arrival time. Regardless of the viewing condition (only monocular or monocular and binocular), the response pattern conformed to a constant velocity strategy. However, when binocular information was available, overestimation was highly reduced.
Resumo:
Semantic Web applications take off is being slower than expected, at least with respect to “real-world” applications and users. One of the main reasons for this lack of adoption is that most Semantic Web user interfaces are still immature from the usability and accessibility points of view. This is due to the novelty of these technologies, but this also motivates the exploration of alternative interaction paradigms, different from the “traditional” Web or Desktop applications ones. Our proposal is realized in the Rhizomer platform, which explores the possibilities of the object–action interaction paradigm at the Web scale. This paradigm is well suited for heterogeneous resource spaces such as those common in the Semantic Web. Resources, described by metadata, correspond to the objects in the paradigm. Semantic web services, which are dynamically associated to these objects, correspond to the actions. The platform is being put into practice in the context of a research project in order to build an open application for media distribution based on Semantic Web technologies. Moreover, its usability and accessibility have been evaluated in this real setting and compared to similar systems.
Resumo:
PURPOSE: To combine weighted iterative reconstruction with self-navigated free-breathing coronary magnetic resonance angiography for retrospective reduction of respiratory motion artifacts. METHODS: One-dimensional self-navigation was improved for robust respiratory motion detection and the consistency of the acquired data was estimated on the detected motion. Based on the data consistency, the data fidelity term of iterative reconstruction was weighted to reduce the effects of respiratory motion. In vivo experiments were performed in 14 healthy volunteers and the resulting image quality of the proposed method was compared to a navigator-gated reference in terms of acquisition time, vessel length, and sharpness. RESULT: Although the sampling pattern of the proposed method contained 60% more samples with respect to the reference, the scan efficiency was improved from 39.5 ± 10.1% to 55.1 ± 9.1%. The improved self-navigation showed a high correlation to the standard navigator signal and the described weighting efficiently reduced respiratory motion artifacts. Overall, the average image quality of the proposed method was comparable to the navigator-gated reference. CONCLUSION: Self-navigated coronary magnetic resonance angiography was successfully combined with weighted iterative reconstruction to reduce the total acquisition time and efficiently suppress respiratory motion artifacts. The simplicity of the experimental setup and the promising image quality are encouraging toward future clinical evaluation. Magn Reson Med 73:1885-1895, 2015. © 2014 Wiley Periodicals, Inc.
Resumo:
PURPOSE: To determine whether a mono-, bi- or tri-exponential model best fits the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) signal of normal livers. MATERIALS AND METHODS: The pilot and validation studies were conducted in 38 and 36 patients with normal livers, respectively. The DWI sequence was performed using single-shot echoplanar imaging with 11 (pilot study) and 16 (validation study) b values. In each study, data from all patients were used to model the IVIM signal of normal liver. Diffusion coefficients (Di ± standard deviations) and their fractions (fi ± standard deviations) were determined from each model. The models were compared using the extra sum-of-squares test and information criteria. RESULTS: The tri-exponential model provided a better fit than both the bi- and mono-exponential models. The tri-exponential IVIM model determined three diffusion compartments: a slow (D1 = 1.35 ± 0.03 × 10(-3) mm(2)/s; f1 = 72.7 ± 0.9 %), a fast (D2 = 26.50 ± 2.49 × 10(-3) mm(2)/s; f2 = 13.7 ± 0.6 %) and a very fast (D3 = 404.00 ± 43.7 × 10(-3) mm(2)/s; f3 = 13.5 ± 0.8 %) diffusion compartment [results from the validation study]. The very fast compartment contributed to the IVIM signal only for b values ≤15 s/mm(2) CONCLUSION: The tri-exponential model provided the best fit for IVIM signal decay in the liver over the 0-800 s/mm(2) range. In IVIM analysis of normal liver, a third very fast (pseudo)diffusion component might be relevant. KEY POINTS: ? For normal liver, tri-exponential IVIM model might be superior to bi-exponential ? A very fast compartment (D = 404.00 ± 43.7 × 10 (-3) mm (2) /s; f = 13.5 ± 0.8 %) is determined from the tri-exponential model ? The compartment contributes to the IVIM signal only for b ≤ 15 s/mm (2.)
Resumo:
This paper presents WiBed, a FOSS platform for WiFi testbeds based on OpenWRT Linux made to run on commodity IEEE802.11 WiFi routers part of the Community-lab.net project, a global testbed for Community networks. WiBed has been designed to support realistic low layer network experiments (according to the OSI model). This work recolects the details of the architecture, design and implementation of WiBed consolidated during its operation as a testbed.
Resumo:
We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies.
Resumo:
Tämä diplomityö kuvaa viestintä sovelluksen ytimen kehitystyön Symbian-alustalle. Koko sovelluksen vaatimuksena oli vastaamattomiin puheluihin vastaaminen ennalta määritellyillä tekstiviesteillä käyttäjän määrittelemien sääntöjen mukaisesti. Ei-toiminnallisia vaatimuksia olivat resurssien käytön vähentäminen ja uudelleenkäytön mahdollistaminen. Täten tämän työn tavoitteena oli kehittää ydin, joka kapseloi sovelluksen sellaisen toiminnallisuuden, joka on käyttöliittymästä riippumatonta ja uudelleenkäytettävää. Kehitystyössä ohjasi Unified Process, joka on iteroiva, käyttötapauksien ohjaama ja arkkitehtuurikeskeinen ohjelmistoprosessi. Se kannusti käyttämään myös muita teollisuudenalan vakiintuneita menetelmiä, kuten suunnittelumalleja ja visuaalista mallintamista käyttäen Unified Modelling Languagea. Suunnittelumalleja käytettiin kehitystyön aikana ja ohjelmisto mallinnettiin visuaalisesti suunnittelun edistämiseksi ja selkiyttämiseksi. Alustan palveluita käytettiin hyväksi kehitysajan ja resurssien käytön minimoimiseksi. Ytimen päätehtäviksi määrättiin viestien lähettäminen sekä sääntöjen talletus ja tarkistaminen. Sovelluksen eri alueet, eli sovelluspalvelin ja käyttöliittymää, pystyivät käyttämään ydintä ja sillä ei ollut riippuvuuksia käyttöliittymätasolle. Täten resurssien käyttö väheni ja uudelleenkäytettävyys lisääntyi. Viestien lähettäminen toteutettiin Symbian-alustan menetelmin. Sääntöjen tallettamiseen tehtiin tallennuskehys, joka eristää sääntöjen sisäisen ja ulkoisen muodon. Tässä tapauksessa ulkoiseksi tallennustavaksi valittiin relaatiotietokanta. Sääntöjen tarkastaminen toteutettiin tavanomaisella olioiden yhteistoiminnalla. Päätavoite saavutettiin. tämä ja muut hyviksi arvioidut lopputulokset, kuten uudelleenkäytettävyys ja vähentynyt resurssien käyttö, arveltiin juontuvan suunnittelumallien ja Unified Processin käytöstä. Kyseiset menetelmät osoittivat mukautuvansa pieniinkin projekteihin. Menetelmien todettiin myös tukevan ja kannustavan kehitystyön aikaista oppimista, mikä oli välttämätöntä tässä tapauksessa.
Resumo:
Tässä diplomityössä perehdytään WAP:in Push -viitekehykseen. WAP-standardit määrittelevät kuinka Internet-tyyppisiä palveluita, joita voidaan käyttää erilaisia mobiileja päätelaiteitteita käyttäen, toteutetaan tehokkaalla ja verkkoteknologiasta riippumattomalla tavalla. WAP pohjautuu Internet:iin, mutta huomioi pienten päätelaitteiden ja mobiiliverkkojen rajoitukset ja erikoisominaisuudet. WAP Push viitekehys määrittelee verkon aloittaman palvelusisällön toimittamisen. Työn teoriaosassa käydään läpi yleinen WAP-arkkitehtuuri ja WAP-protokollapino käyttäen vertailukohtina lanka-Internetin arkkitehtuuria ja protokollapinoa. Edellistä perustana käyttäen tutustaan WAP Push -viitekehykseen. Käytännönosassa kuvataan WAP Push -välityspalvelimen suunnittelu ja kehitystyö. WAP Push -välityspalvelin on keskeinen verkkoelementti WAP Push -viitekehyksessä. WAP Push -välityspalvelin yhdistää Internetin ja mobiiliverkon tavalla, joka piilottaa teknologiaeroavaisuudet Internetissä olevalta palveluntuottajalta.
Resumo:
Tämän diplomityön tavoitteena oli tutkia älykkäiden paikoituskäyttöjen markkinoita ja liiketoimintamalleja. Työn pääongelmina oli määritellä alalla käytössä olevaa terminologiaa, määrittää markkinoiden koko paikoitusominaisuudet omaaville kolmivaihetaajuusmuuttajille, tutkia viiden alalla toimivan paikoituskäyttötoimittajan liiketoimintarakenteita ja tuotteita teknisestä näkökulmasta sekä esitellä kaksi teollisuuden käyttökohdetta paikoituskäytölle. Työn sisältö voidaan jakaa neljään eri osioon. Terminologian määrittely- ja markkinatutkimusosiot perustuvat pääasiassa kirjallisuustutkimukseen. Paikoituskäyttöjen toimittajia sekä niiden tuotteita käsittelevä osuus perustuu kirjallisuustutkimukseen sekä teknisiin esitteisiin ja manuaaleihin. Paikoituskäyttöjen sovellusesimerkit on selvitetty haastatteluin. Työ painottuu paikoituskäyttötoimittajien tuotteiden, tuoteominaisuuksien ja tuotetarjonnan tarkasteluun. Työn tuloksena on määritelty paikoituskäyttöjen liiketoiminnan tärkeimmät termit, paikoituskäyttöjen markkinoiden koko sekä markkinoiden koko paikoitusominaisuudet omaavalle kolmivaihetaajuusmuuttajalle. Alalla toimivien paikoituskäyttötoimittajien liiketoimintarakenne on selvitetty, jonka mukaan toimittajat on profiloitu komponentti-, komponenttipaketti-, toimialakeskeisiksi tai automaatiotoimittajiksi. Toimittajien paikoituskäyttötuotteet on luokiteltu viiteen eri luokkaan niiden teknisten ominaisuuksien perusteella. Lisäksi paikoituskäyttöjen suorituskyvyt on selvitetty säätimien momentti-, nopeus-, ja paikoituslaskenta-aikatasojen sekä kenttäväyläliityntöjen suhteen. Työssä kuvatut vanerinsorvausprosessi sekä FMS -materiaalinkäsittelyprosessi esittävät paikoituskäyttöjen potentiaalisia sovelluskohteita.
Resumo:
Electrical impedance tomography (EIT) is a non-invasive imaging technique that can measure cardiac-related intra-thoracic impedance changes. EIT-based cardiac output estimation relies on the assumption that the amplitude of the impedance change in the ventricular region is representative of stroke volume (SV). However, other factors such as heart motion can significantly affect this ventricular impedance change. In the present case study, a magnetic resonance imaging-based dynamic bio-impedance model fitting the morphology of a single male subject was built. Simulations were performed to evaluate the contribution of heart motion and its influence on EIT-based SV estimation. Myocardial deformation was found to be the main contributor to the ventricular impedance change (56%). However, motion-induced impedance changes showed a strong correlation (r = 0.978) with left ventricular volume. We explained this by the quasi-incompressibility of blood and myocardium. As a result, EIT achieved excellent accuracy in estimating a wide range of simulated SV values (error distribution of 0.57 ± 2.19 ml (1.02 ± 2.62%) and correlation of r = 0.996 after a two-point calibration was applied to convert impedance values to millilitres). As the model was based on one single subject, the strong correlation found between motion-induced changes and ventricular volume remains to be verified in larger datasets.
Resumo:
Lähitulevaisuudessa langattomien järjestelmien kaupalliset mahdollisuudet tulevat olemaan valtavia. Tutkiaksemme tulevia tarpeita, tässä diplomityössä esitellään kuinka voidaan suunnitella ja toteuttaa avoin langaton asiakas-palvelin järjestelmä. Järjestelmänä päätettiin käyttää Bluetooth:ia. Tutkituista langattomista standardeista Bluetooth sopii parhaiten akkukäyttöiselle laitteelle, jonka tulee olla monipuolinen. Lisäksi Bluetooth:iin on liitetty suuria kaupallisia odotuksia ja yksi työn tavoitteista olikin tutkia, ovatko nämä odotukset realistisia. Bluetooth:iin havaittiin liittyvän paljon ylimainontaa ja, sen todettiin olevan monimutkainen. Sillä on kuitenkin paljon ominaisuuksia ja erilaisten käyttöprofiilien avulla sitä voidaan käyttää monenlaisiin tehtäviin. Suunniteltu järjestelmä ajaa socket-palvelinta Bluetooth-yhteyden päällä. Tietyntyyppiseen liikenteeseen erikoistuneet socket:t tarjoavat vaaditun laajennattavuuden. Palvelin toteutetiin Linux-säikeenä ja se hallitsee Bluetooth protokollapinoa sekä sovelluksia, joita suoritetaan palvelimella. Näiden sovelluksien palvelut ovat muiden käytössä Bluetooth:n kautta.