822 resultados para frp, compositi, fibre, legno, consolidamento
Resumo:
In this work, robustness and stability of continuum damage models applied to material failure in soft tissues are addressed. In the implicit damage models equipped with softening, the presence of negative eigenvalues in the tangent elemental matrix degrades the condition number of the global matrix, leading to a reduction of the computational performance of the numerical model. Two strategies have been adapted from literature to improve the aforementioned computational performance degradation: the IMPL-EX integration scheme [Oliver,2006], which renders the elemental matrix contribution definite positive, and arclength-type continuation methods [Carrera,1994], which allow to capture the unstable softening branch in brittle ruptures. The IMPL-EX integration scheme has as a major drawback the need to use small time steps to keep numerical error below an acceptable value. A convergence study, limiting the maximum allowed increment of internal variables in the damage model, is presented. Finally, numerical simulation of failure problems with fibre reinforced materials illustrates the performance of the adopted methodology.
Resumo:
En el presente trabajo se han analizado los modelos tensión-deslizamiento más divulgados para estudiar las tensiones en la interfase FRP-Hormigón y la carga máxima mediante su irapíementación en una de las principales técnicas de cálculo numérico fácilmente programable y aplicable para el caso en el que se tiene tracción en ambos extremos de la banda FRP. Los resultados se comparan con las soluciones analíticas encontradas en la literatura, las cuales están limitadas a los casos de una función tensión-deslizamiento lineal y bilineal. Finalmente, se contrasta la teoría con los resultados experimentales obtenidos de ensayos de tipología análoga al método beamtest empleado comúnmente para medir la adherencia de barras de acero.
Resumo:
Next generation access networks (NGAN) will support a renewed communication structure where opportunities lie in the provision of ubiquitous broadband connectivity, a wide variety of new applications, appealing contents and a general support to the sustainable growth of diverse sectors. From their deployment it is expected a wealth of innovations, jobs creation and a new wave of economic growth. In this paper we discuss which could be the role of Hybrid Fibre Coax (HFC) in the Next Generation Access Network (NGAN) roadmap. Thus, we propose a simplified model for making approximate cost calculations for HFC deployment based on the geographic and sociodemographic characteristics of Spain. Considering the latest evolution of HFC based on DOCSIS 3.0 from integrated (I-CMTS) towards modular (M-CMTS), the results from the model are compared with the most competitive NGAN for ultrabroadband speeds: Fibre to the Home (FTTH) based on Gigabitcapable Passive Optical Networks (GPON)
Resumo:
The adhesives used for applications in marine environments are subject to particular chemical conditions, which are mainly characterised by an elevated chlorine ion content and intermittent wetting/drying cycles, among others.These conditions can limit the use of adhesives due to the degradation processes that they experience. In this work, the chemical degradation of two different polymers, polyurethane and vinylester, was studied in natural seawater under immersion for different periods of time.The diffusion coefficients and concentration profiles of water throughout the thickness of the adhesiveswere obtained.Microstructural changes in the polymer due to the action of water were observed by SEM, and the chemical degradation of the polymer was monitored with the Fourier transform infrared spectroscopy (FTIR) and differential scanning calorimetry (DSC). The degradation of the mechanical properties of the adhesive was determined by creep tests withMixed Cantilever Beam (MCB) specimens at different temperatures. After 180 days of immersion of the specimens, it was concluded that the J-integral value (depending on the strain) implies a loss of stiffness of 51% and a decrease in the failure load of 59% for the adhesive tested.
Resumo:
The end-notched flexure (ENF) test calculates the value of mode II fracture energy in adhesive bonding between the substrates of same nature. Traditional methods of calculating fracture energy in the ENF test are not suitable in cases where the thickness of the adhesive is non-negligible compared with adherent thicknesses. To address this issue, a specific methodology for calculating mode II fracture energy has been proposed in this paper. To illustrate the applicability of the proposed method, the fracture energy was calculated by the ENF test for adhesive bonds between aluminium and a composite material, which considered two different types of adhesive (epoxy and polyurethane) and various surface treatments. The proposed calculation model provides higher values of fracture energy than those obtained from the simplified models that consider the adhesive thickness to be zero, supporting the conclusion that the calculation of mode II fracture energy for adhesives with non-negligible thickness relative to their adherents should be based on mathematical models, such as the method proposed in this paper, that incorporate the influence of this thickness.
Resumo:
The use of fiber-reinforced polymer (FRP) composites for strengthening, repairing, or rehabilitating concrete structures has become more and more popular in the last 10 years. Irrespective of the type of strengthening used, design is conditioned, among others, by concrete-composite bond failure, normally attributed to stress at the interface between these two materials. Single shear, double shear, and notched beam tests are the bond tests most commonly used by the scientific community to estimate bond strength, effective length, and the bond stress-slip relationship. The present paper discusses the effect of concrete strength and adhesive thickness on the results of beam tests, which reproduce debonding conditions around bending cracks much more accurately. The bond stress-slip relationship was analyzed in a cross section near the inner edge, where stress was observed to concentrate. The ultimate load and the bond stress-slip relationship were visibly affected by concrete strength. Adhesive thickness, in turn, was found to have no significant impact on low-strength concrete but a somewhat greater effect on higher strength materials.
Resumo:
Smooth light extraction in lighting optical fibre
Resumo:
Presentación realizada en el PhD Seminar del ITS 2011 en Budapest. ICTs (Information and Communication Technologies) currently account for 2% of total carbon emissions. However, although modern standards require strict measures to reduce energy consumption across all industrial and services sectors, the ICT sector also faces an increase in services and bandwidth demand. The deployment of Next Generation Networks (NGN) will be the answer to this new demand; more specifically, Next Generation Access Networks (NGANs) will provide higher bandwidth access to users. Several policy and cost analyses are being carried out to understand the risks and opportunities of new deployments, but the question of what role energy consumption plays in NGANs seems off the table. Thus, this paper proposes a model to analyse the energy consumption of the main fibre-based NGAN architectures: Fibre To The House (FTTH), in both Passive Optical Network (PON) and Point-to-Point (PtP) variations, and FTTx/VDSL. The aim of this analysis is to provide deeper insight on the impact of new deployments on the energy consumption of the ICT sector and the effects of energy consumption on the life-cycle cost of NGANs. The paper also presents an energy consumption comparison of the presented architectures, particularised to the specific geographic and demographic distribution of users of Spain but easily extendable to other countries.
Resumo:
In this work, robustness and stability of continuum damage models applied to material failure in soft tissues are addressed. In the implicit damage models equipped with softening, the presence of negative eigenvalues in the tangent elemental matrix degrades the condition number of the global matrix, leading to a reduction of the computational performance of the numerical model. Two strategies have been adapted from literature to improve the aforementioned computational performance degradation: the IMPL-EX integration scheme [Oliver,2006], which renders the elemental matrix contribution definite positive, and arclength-type continuation methods [Carrera,1994], which allow to capture the unstable softening branch in brittle ruptures. The IMPL-EX integration scheme has as a major drawback the need to use small time steps to keep numerical error below an acceptable value. A convergence study, limiting the maximum allowed increment of internal variables in the damage model, is presented. Finally, numerical simulation of failure problems with fibre reinforced materials illustrates the performance of the adopted methodology.
Resumo:
The potential use of commercial fibres (pea fibre, inulin, and their blends), as fibre-enriching agents in frozen/thawed mashed potatoes was reported. Pea fibre and inulin supplementations conferred hardness and softness to the product, respectively. Differences were attributed to the relationship of the fibre with the potato starch matrix. The association of pea fibre at low concentration (<15 g/kg mashed potatoes) and inulin at high concentration (>45 g/kg) is strongly encouraged to fortify the diet without promoting negative effects on textural and rheological properties of frozen/thawed mashed potatoes or colour and overall acceptability of the resulting products.
Resumo:
A time division multiplexing (TDM) array for passive multiplexing of identical fibre, optic intensity sensors has been demonstrated. Microbending loss sensors are introduced in fibre optic rings and pressure information is directly detected, demultiplexed and demodulated from the relative amplitude of the first two pulses produced on each ring. Several dynamic ranges from 6 dB to 14 dB are shown. A comparison between both fibre optic ring and Mach-Zehnder structure impulse responses is carried out and the consequences derived from second- and higher-order recirculating ring pulses are also evaluated. This technique can be applied to those TDM intensity sensing schemes which require low cost, high number of identical sensors, and suffer high element loss and undersirable intensity fluctuations at low frequencies.
Resumo:
Methods for predicting the shear capacity of FRP shear strengthened RC beams assume the traditional approach of superimposing the contribution of the FRP reinforcing to the contributions from the reinforcing steel and the concrete. These methods become the basis for most guides for the design of externally bonded FRP systems for strengthening concrete structures. The variations among them come from the way they account for the effect of basic shear design parameters on shear capacity. This paper presents a simple method for defining improved equations to calculate the shear capacity of reinforced concrete beams externally shear strengthened with FRP. For the first time, the equations are obtained in a multiobjective optimization framework solved by using genetic algorithms, resulting from considering simultaneously the experimental results of beams with and without FRP external reinforcement. The performance of the new proposed equations is compared to the predictions with some of the current shear design guidelines for strengthening concrete structures using FRPs. The proposed procedure is also reformulated as a constrained optimization problem to provide more conservative shear predictions.
Resumo:
This work compared the quantification of soluble fibre in feeds using different chemical and in vitro approaches, and studied the potential interference between soluble fibre and mucin determinations. Six ingredients: sugar beet pulp (SBP), SBP pectins, insoluble SBP, wheat straw, sunflower hulls and lignocellulose, and seven rabbit diets, differing in soluble fibre content, were evaluated. In experiment 1, ingredients and diets were analyzed for total dietary fibre (TDF), insoluble dietary fibre (IDF), soluble dietary fibre (SDF), aNDFom (corrected for protein, aNDFom-cp) and 2-step pepsin/pancreatin in vitro DM indigestibility (corrected for ash and protein, ivDMi2). Soluble fibre was estimated by difference using three procedures: TDF?IDF (SDFIDF), TDF?ivDMi2 (SDFivDMi2), and TDF?aNDFom-cp (SDFaNDFom-cp). Soluble fibre determined directly (SDF) or by difference as SDFivDMi2 were not different (109 g/kg DM, on average). However, when it was calculated as SDFaNDFom-cp the value was 40% higher (153 g/kg DM, P menor que 0.05), whereas SDFIDF (124 g/kg DM) did not differ from any of the other methods. The correlation between the four methods was high (r ? 0.96; P ? 0.001; n = 13), but it decreased or even disappeared when SBP pectins and SBP were excluded and a lower and more narrow range of variation of soluble fibre was used. In experiment 2, the ivDMi2 using crucibles (reference method) were compared to those made using individual or collective ankom bags in order to simplify the determination of SDFivDMi2. The ivDMi2 was not different when using crucibles or individual or collective ankom bags. In experiment 3, the potential interference between soluble fibre and intestinal mucin determinations was studied using rabbit intestinal raw mucus, digesta and SBP pectins, lignocelluloses and a rabbit diet. An interference was observed between the determinations of soluble fibre and crude mucin, as contents of TDF and apparent crude mucin were high in SBP pectins (994 and 709 g/kg DM) and rabbit intestinal raw mucus (571 and 739 g/kg DM). After a pectinase treatment, the coefficient of apparent mucin recovery of SBP pectins was close to zero, whereas that of rabbit mucus was not modified. An estimation of the crude mucin carbohydrates retained in digesta TDF is proposed to correct TDF and soluble fibre digestibility. In conclusion, the values of soluble fibre depend on the methodology used. The contamination of crude mucin with soluble fibre is avoided using pectinase.
Resumo:
Modelo de daño no local definido a materiales fibrados. Este modelo se aplica al estudio de problemas típicos en la biomecánica de los tejidos blandos, como las paredes arteriales.
Resumo:
El uso de refuerzos NSM‐FRP en estructuras de hormigón armado se ha incrementado considerablemente en los últimos años como método de refuerzo estructural. Los ensayos de arrancamiento en viga de los refuerzos NSM‐FRP permiten el estudio del comportamiento de la unión pegada. El principal objetivo del presente trabajo aborda la simulación numérica de este tipo de ensayos, con el propósito de caracterizar correctamente la adherencia entre las barras de NSM‐FRP y el hormigón. En una fase inicial se simuló un modelo bidimensional para conseguir evaluar y verificar el comportamiento de los elementos cohesivos y ver su comportamiento primero ante diferentes modelos de material y segundo ante un modo mixto de fallo, debido a la aplicación simultanea de carga axial y carga cortante. En una segunda fase se creó un modelo tridimensional para estudiar el arrancamiento de una barra de material compuesto insertada en hormigón, creando un modelo de material de hormigón y viendo el comportamiento cualitativo del sistema ante variaciones en los parámetros de los diferentes materiales. En la tercera fase, la más importante del presente trabajo, se abordó la simulación numérica del ensayo de arrancamiento en viga. Se simularon todos los componentes del ensayo y se evaluaron diferentes alternativas para representar la interfase NSM‐FRP ‐ hormigón, usando elementos cohesivos y diferentes distribuciones de los mismos en la interfase. Para conseguir representar lo más fielmente posible las condiciones del ensayo, se diseñó también un controlador PID que permite realizar las simulaciones numéricas mediante un control en desplazamientos, lo cual permite capturar más correctamente el comportamiento de reblandecimiento de la unión pegada. El controlador PID aplica técnicas de ingeniería de control para conseguir calcular a priori la amplitud necesaria del desplazamiento impuesto que provoque una evolución establecida en una variable interna del sistema. La variable usada para correlacionar los ensayos es la diferencia en desplazamientos entre dos puntos y se escoge una evolución lineal de la misma, pero en la tesis también se exponen los resultados de escoger otras posibles variables internas con diferentes evoluciones. Se compararon las simulaciones numéricas con resultados de mediciones experimentales previamente publicadas. Los resultados carga‐deslizamiento obtenidos encajan bien con los datos experimentales. El modelo propuesto es también capaz de predecir el modo de fallo en la interfase NSM‐FRP ‐ hormigón. Finalmente, también se han llevado a cabo estudios paramétricos, para evaluar la influencia de cada parámetro en los resultados. También se realizó un estudio cualitativo de cómo se comporta la unión pegada en cada momento de la simulación, mediante el uso macros y gráficas tridimensionales, para conseguir una mejor visualización y facilitar el análisis de los resultados. ABSTRACT The use of near‐surface mounted FRP reinforcement in reinforced concrete structures has seen a considerable increase in recent years as a strengthening method. Beam pull‐out tests for near‐surface reinforcement allow obtaining the local bond‐slip behavior of a bonded joint. The main objective of the current work deals with the three‐dimensional modeling of this kind of test with the purpose of characterizing suitably the mechanics of bond between FRP rods and concrete. In an initial stage, a two bidimensional in order to evaluate and to verify the behavior of the cohesive elements. Its behavior was evaluated first testing different material models and second testing the behavior when mixed mode failure appears, due to simultaneous axial and shear load. In a second stage a tridimensional model was created in order to study the pull‐out of an inserted beam of composite material in concrete. A concrete material model was created and the influence of each material parameter was studied qualitatively. The third part, the most relevant of the present work, the numerical simulation of the Beam Pull‐Out test was faced. All the parts of the Beam Pull‐Out test were included inthe simulation and different alternatives to represent the FRP bar – concrete interface have been evaluated, using cohesive elements and different distributions of them. In order to reproduce the test conditions more reliably, a PID controller has also been designed to conduct suitably the numerical tests in order to properly capture the softening branch of the load‐slip behaviour. The PID controller applies control techniques to calculate a priori the necessary amplitude of the load in order to achieve a given evolution through the simulation of an internal variable previously chosen. The variable used in order to correlate the simulation with the test results is the difference in displacements between two points and a linear evolution was chosen, but in the thesis the results of choosing other possible internal variables with different evolutions are also shown. The numerical FE simulations were compared with experimental measurements previously published. Load‐slip predictions compare well with the corresponding experimental data. The proposed model is also able to predict the failure mode at the FRP‐concrete interface. Some parametric studies have also been carried out, in order to evaluate the influence of each material parameter in the results. A qualitative study of the behaviour of the joint was also performed, using the results of the numeric simulations and through the use of macros and 3D graphs, the tensional state of each point of the joint can be visualized in each moment of the simulation.