986 resultados para dental implant-abutment design


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To investigate the construction of cobalt-chromium removable partial dentures by commercial private dental laboratories. Methods: Ninety master casts for fabrication of cobalt-chromium removable partial dentures were obtained from three commercial laboratories randomly selected. Casts were assessed for dental arch treated, Kennedy classification, cast surveying, denture design information provided by the dentist, and mouth preparation (rest seat, guiding plane and retentive area). Dental technicians answered a questionnaire regarding qualification of assisted dentists, monthly number of framework castings, and use of dental surveyor. Mouth preparation was compared among laboratories using Kruskal-Wallis test (α=0.05). Results: The percentage of Kennedy class I was 16%, class II 19%, class III 56%, and class IV 9%. The majority of master cats (51%) examined was sent to dental laboratories without any design information and did not comply with ethical guidelines in the provision of RPD. Approximately half of the casts were considered “inappropriate” for guiding planes and retentive areas. One of the laboratories presented all casts “inappropriate” for rest seat distribution (p<0.001). Conclusions: Mouth preparation frequently failed for guiding planes, retentive areas and distribution of rest seats. It is necessary to provide students with adequate clinical experience at the dental school environment, which will actually be carried into the practice of dentistry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The primary aim of this study was to investigate partially dentate elders' willingness-to-pay (WTP) for two different tooth replacement strategies: Removable Partial Dentures (RPDs) and, functionally orientated treatment according to the principles of the Shortened Dental Arch (SDA). The secondary aim was to measure the same patient groups' WTP for dental implant treatment.Methods: 55 patients who had completed a previous RCT comparing two tooth replacement strategies (RPDs (n=27) and SDA (n=28)) were recruited (Trial Registration no. ISRCTN26302774). Patients were asked to indicate their WTP for treatment to replace missing teeth in a number of hypothetical scenarios using the payment card method of contingency evaluation coupled to different costs. Data were collected on patients' social class, income levels and other social circumstances. A Mann-Whitney U Test was used to compare differences in WTP between the two treatment groups. To investigate predictive factors for WTP, multiple linear regression analyses were conducted.Results: The median age for the patient sample was 72.0 years (IQR: 71-75 years). Patients who had been provided with RPDs indicated that their WTP for this treatment strategy was significantly higher (€550; IQR: 500-650) than those patients who had received SDA treatment (€500; IQR: 450-550) (p=0.003). However patients provided with RPDs indicated that their WTP for SDA treatment (€650; IQR: 600-650) was also significantly higher than those patients who had actually received functionally orientated treatment (€550; IQR: 500-600) (p<0.001). The results indicated that both current income levels and previous treatment allocation were significantly correlated to WTP for both the RPD and the SDA groups. Patients in both treatment groups exhibited little WTP for dental implant treatment with a median value recorded which was half the market value for this treatment (€1000; IQR: 500-1000).Conclusions: Amongst this patient cohort previous treatment experience had a strong influence on WTP as did current income levels. Both treatment groups indicated a very strong WTP for simpler, functionally orientated care using adhesive fixed prostheses (SDA) over conventional RPDs. Clinical significance: Partially dentate older patients expressed a strong preference for functionally orientated tooth replacement as an alternative to conventional RPDs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction - After tooth extraction, the alveolar bone undergoes a remodeling process, wich leads to horizontal and vertical bone loss. These resorption processes complicate dental rehabilitation, particularly in connection with implants. Various methods of guided bone regeneration have been described to retain the original dimension of the bone after extraction. Most procedures use filler materials and membranes to support the buccal plate and soft tissue, to stabilize the coagulum and to prevent epithelial ingrowth. It has also been suggested that resorption of the buccal bundle bone can be avoided by leaving a buccal root segment (socket-shield technique) in place, because the biological integrity of the buccal periodontum remains untouched. This method has also been decribed in connection with immediate implant placement. Objective - This literature review aim enumerate and describe the different treatments and tissue reactions after tooth extraction, immediate and delayed implantation. The socketshield technique, the evolution in tooth extraction and immediate implantation with high esthetic results due to the preservation of hard and soft tissues by leaving a buccal root segment in place. Materials and methods - For this purpose a research has been done and data was obtained from on-line resources: Medline, Pubmed, Scielo, Bireme, Bon, books and specialized magazines which was conducted between January 2016 and May 2016. A number of articles have been obtained in English and French ,published between 1997 and 2015 . The key words used were implantology, dental implant, hard/soft tissue, tooth extraction, immediate implantation, delayed implantation, socket-shield. Conclusion - In socket-shield technique, there were neither functional nor aesthetic changes in soft and hard tissues. It’s already a routine practice in the arsenal of highaesthetic immediate implantology and should be used when indicated. Although this technique is quiet promising, we should be aware of the incoming publications about a larger follow up and the predictability of leaving a fragment inside the socket after an extraction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os tratamentos odontológicos com implantes dentários, têm sido bem documentados nos últimos 40 anos e com grandes sucessos. O implante dentário instalado no local de dentes perdidos deve envolver sempre um correto planejamento pelo médico dentista. Nesta área é muito importante o conhecimento do microbioma que envolve o implante dentário, desde seu planejamento até a reabilitação final. O tempo exato com que o microbioma se forma, assim como, os microrganismos presentes são fundamentais para a correta execução e êxito do implante. Contudo a contaminação interna dos implantes reabilitados, os componentes extracelulares de microrganismos, como as endotoxinas, têm uma enorme influência no sucesso dos implantes. Além disso, o conhecimento das superfícies dos implantes e a relação com a presença microbiana também muito importante. O presente estudo realizou uma revisão bibliográfica sobre o microbioma oral e sua relação com a infecção periimplantar, discutindo diversos estudos, tanto clássicos como atuais. Embora se possa concluir que o microbioma periimplantar é caracterizado pelo microbioma anterior à instalação dos implantes dentários, podemos referir a necessidade de mais estudos de modo a elucidar melhor o planejamento e a longevidade dos tratamentos com implantes dentários.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introdução: A peri-implantite, um processo inflamatório que destroi e afeta tanto os tecidos moles como o tecido osseo em redor de um implante dentário Esta patologia vai ter grande influência a quando da escolha de uma solução terapêutica, sendo as principais opções terapêuticas a cirurgia regenerativa e ressetiva. Objetivo: Efetuar uma revisão bibliográfica no que diz respeito á peri-implantite e aos seus tratamentos cirurgicos convencionais, abordando tambem questões epidemiologicas da patologia e fatores de risco. Metodologia: A presente revisão bibliográfica foi baseada em informação ciêntifica publicada. Recorreu-se ás seguintes bases de dados: “MEDLINE/Pubmed”, “SciELO”, “EBSCO HOST” e “Science Direct”, através da introdução das seguintes palavras-chave: “Peri-implantitis”, “Mucositis”, “Peri-implant infections”, “Diagnosis”, “Treatment”, “Risk factors”, “Surgical treatment”. Conclusão: Para cada situação clínica de peri-implantite, é importante recorrer a diversos parâmetros de diagnóstico, como por exemplo o índice de placa, profundidade e hemorragia à sondagem, supuração e a evidência de perda óssea radiográfica. Aquando de reabilitação oral com implantes, o paciente deverá obedecer a um programa de manutenção eficaz, com o objetivo de manter a integridade dos tecidos peri-implantares. Na literatura científica são descritas diversas possibilidades de tratamento, existe enumero protocolos terapêuticos a efetuar. O médico dentista deve adoptar com base no diagnostico rigoroso o melhor tratamento a efetuar. Nesta linha de pensamentos existem várias aborgens terapêuticas que podemos efetuar, sendo a cirurgia ressetiva e a cirurgia regenerativa soluções têrapeuticas de elevada importância no que diz respeito ao sucesso no tratamento da peri-implantite.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An ideal biomaterial for dental implants must have very high biocompatibility, which means that such materials should not provoke any serious adverse tissue response. Also, used metal alloys must have high fatigue resistance due the masticatory force and good corrosion resistance. These properties are rendered by using alpha and beta stabilizers, such as Al, V, Ni, Fe, Cr, Cu, Zn. Commercially pure titanium (TiCP) is used often for dental and orthopedic implants manufacturing. However, sometimes other alloys are employed and consequently it is essential to research the chemical elements present in those alloys that could bring prejudice for the health. Present work investigated TiCP metal alloys used for dental implant manufacturing and evaluated the presence of stabilizing elements within existing limits and standards for such materials. For alloy characterization and identification of stabilizing elements it was used EDXRF technique. This method allows to perform qualitative and quantitative analysis of the materials using the spectra of the characteristic X-rays emitted by the elements present in the metal samples. The experimental setup was based on two X- rays tubes (AMPTEK Mini X model with Ag and Au targets), a X-123SDD detector (AMPTEK) and a 0.5mm Cu collimator, developed due to the sample characteristics. The other experimental setup used as a complementary technique is composed of an X-ray tube with a Mo target, collimator 0.65mm and XFlash (SDD) detector - ARTAX 200 (BRUKER). Other method for elemental characterization by energy dispersive spectroscopy (EDS) applied in present work was based on Scanning Electron Microscopy (SEM) EVO® (Zeeis). This method also was used to evaluate the surface microstructure of the sample. The percentual of Ti obtained in the elementary characterization was among 93.35 ± 0.17% and 95.34 ± 0.19 %. These values are considered below the reference limit of 98.635% to 99.5% for TiCP, established by Association of metals centric materials engineers and scientists Society (ASM). The presence of elements Al and V in all samples also contributed to underpin the fact that are not TiCP implants. The values for Al vary between 6.3 ± 1.3% and 3.7 ± 2.0% and for V, between 0.26 ± 0.09% and 0.112 ± 0.048%. According to the American Society for Testing and Materials (ASTM), these elements should not be present in TiCP and in accordance with the National Institute of Standards and Technology (NIST), the presence of Al should be <0.01% and V should be of 0.009 ± 0.001%. Obtained results showed that implant materials are not exactly TiCP but, were manufactured using Ti-Al-V alloy, which contained Fe, Ni, Cu and Zn. The quantitative analysis and elementary characterization of experimental results shows that the best accuracy and precision were reached with X-Ray tube with Au target and collimator of 0.5 mm. Use of technique of EDS confirmed the results of EDXRF for Ti-Al-V alloy. Evaluating the surface microstructure by SEM of the implants, it was possible to infer that ten of the thirteen studied samples are contemporaneous, rough surface and three with machined surface.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE The aim of this cross-sectional study was to estimate bone loss of implants with platform-switching design and analyze possible risk indicators after 5 years of loading in a multi-centered private practice network. METHOD AND MATERIALS Peri-implant bone loss was measured radiographically as the distance from the implant shoulder to the mesial and distal alveolar crest, respectively. Risk factor analysis for marginal bone loss included type of implant prosthetic treatment concept and dental status of the opposite arch. RESULTS A total of 316 implants in 98 study patients after 5 years of loading were examined. The overall mean value for radiographic bone loss was 1.02 mm (SD ± 1.25 mm, 95% CI 0.90- 1.14). Correlation analyses indicated a strong association of peri-implant bone loss > 2 mm for removable implant-retained prostheses with an odds ratio of 53.8. CONCLUSION The 5-year-results of the study show clinically acceptable values of mean bone loss after 5 years of loading. Implant-supported removable prostheses seem to be a strong co-factor for extensive bone level changes compared to fixed reconstructions. However, these results have to be considered for evaluation of the included special cohort under private dental office conditions.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Nowadays, different techniques are available for manufacturing full-arch implant-supported prosthesis, many of them based on an impression procedure. Nevertheless, the long-term success of the prosthesis is highly influenced by the accuracy during such process, being affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of a 3D electromagnetic motion tracking system as an acquisition method for modeling such prosthesis. To this extent, we propose an implant acquisition method at the patient mouth, using a specific prototyped tool coupled with a tracker sensor, and a set of calibration procedures (for distortion correction and tool calibration), that ultimately obtains combined measurements of the implant’s position and angulation, and eliminating the use of any impression material. However, in the particular case of the evaluated tracking system, the order of magnitude of the obtained errors invalidates its use for this specific application.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The success of the osseointegration concept and the Brånemark protocol is highly associated to the accuracy in the production of an implant-supported prosthesis. One of most critical steps for long-term success of these prosthesis is the accuracy obtained during the impression procedure, which is affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of 3D electromagnetic motion tracking systems as an acquisition method for modeling full-arch implant-supported prosthesis. To this extent, we propose an implant acquisition method at the patient mouth and a calibration procedure, based on a 3D electromagnetic tracker that obtains combined measurements of implant’s position and angulation, eliminating the use of any impression material. Three calibration algorithms (namely linear interpolation, higher-order polynomial and Hardy multiquadric) were tested to compensate for the electromagnetic tracker distortions introduced by the presence of nearby metals. Moreover, implants from different suppliers were also tested to study its impact on tracking accuracy. The calibration methodology and the algorithms employed proved to implement a suitable strategy for the evaluation of novel dental impression techniques. However, in the particular case of the evaluated electromagnetic tracking system, the order of magnitude of the obtained errors invalidates its use for the full-arch modeling of implant-supported prosthesis.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

The purpose of this study was to histomorphometrically evaluate the bone-to-implant contact and bone area around a titanium implant retrieved from a human lower jaw. A screw-shaped titanium implant (sandblasted and acid-etched surface) was removed from a 68-year-old male after having been in function for 40 months because of a fracture of the abutment screw. Following the implant removal, an undecalcified section was obtained. The histomorphometric analysis showed a rate of 75.40% of bone-to-implant contact and 89.30% of bone area filling within the limits of the implant threads. The surrounding bone healed in a well-organized pattern and could not be differentiated from the anginal alveolus. The histologic evidence showed a high degree of osseointegration in a threaded, sandblasted, and acid-etched implant retrieved from a human lower jaw after functional loading for 40 months. Copyright © 2005 by Lippincott Williams & Wilkins.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. © 2013 Elsevier Ltd.