863 resultados para critical path methods
Resumo:
The running velocities associated to lactate minimum (V-lm), heart rate deflection (V-HRd), critical velocity (CV), 3000 M (V-3000) and 10000 m performance (V-10km) were compared. Additionally the ability of V-lm and VHRd on identifying sustainable velocities was investigated.Methods. Twenty runners (28.5 +/- 5.9 y) performed 1) 3000 m running test for V3000; 2) an all-out 500 in sprint followed by 6x800 m incremental bouts with blood lactate ([lac]) measurements for V-lm; 3) a continuous velocity-incremented test with heart rate measurements at each 200 m for V-HRd; 4) participants attempted to 30 min of endurance test both at V-lm(ETVlm) and V-HRd(ETVHRd). Additionally, the distance-time and velocity-1/time relationships produced CV by 2 (500 m and 3000 m) or 3 predictive trials (500 m, 3000 m and distance reached before exhaustion during ETVHRd), and a 10 km race was recorded for V-10km.Results. The CV identified by different methods did not differ to each other. The results (m(.)min(-1)) revealed that V-.(lm) (281 +/- 14.8)< CV (292.1 +/- 17.5)=V-10km (291.7 +/- 19.3)< V-HRd (300.8 +/- 18.7)=V-3000 (304 +/- 17.5) with high correlation among parameters (P < 0.001). During ETVlm participants completed 30 min of running while on the ETVHRd they lasted only 12.5 +/- 8.2 min with increasing [lac].Conclusion. We evidenced that CV and Vim track-protocols are valid for running evaluation and performance prediction and the parameters studied have different significance. The V-lm reflects the moderate-high intensity domain (below CV), can be sustained without [lac] accumulation and may be used for long-term exercise while the V-HRd overestimates a running intensity that can be sustained for long-time. Additionally, V-3000 and V-HRd reflect the severe intensity domain (above CV).
Resumo:
We consider the dynamics of a system of interacting spins described by the Ginzburg-Landau Hamiltonian. The method used is Zwanzig's version of the projection-operator method, in contrast to previous derivations in which we used Mori's version of this method. It is proved that both methods produce the same answer for the Green's function. We also make contact between the projection-operator method and critical dynamics.
Resumo:
Photoacoustic spectroscopy was used to determine the critical distance for electron transfer from porphyrin to quinone molecules randomly dispersed in a polymeric matrix. An enhancement of the porphyrin signal was observed as the quinone concentration was increased. The data was analyzed according to the Perrin model [1] and it was found that the electron transfer occurred if the prophyrin-quinone distance was less than 33 Angstrom. To confirm the validity of the method, the fluorescence quenching was also measured for the samples. In this case, the same critical distance was obtained.
Resumo:
Background. Previous studies from our laboratory have shown that luminal perfusion with arginine vasopressin (AVP) stimulates distal tubule secretory potassium flux (J(K)) via V1 receptors (Am J Physiol 278: F809- F816, 2000). In the present work, we investigate the cell signaling mechanism of this process.Methods. In vivo stationary microperfusion was performed in rat cortical distal tubules and luminal K was measured using double K+ resin/reference microelectrodes.Results. In control conditions, J(K) was 0.71 +/- 0.05 nmol. cm(-2).second(-1); this process was inhibited (14%) by 10(-5) mol/L 8-bromo-cyclic adenosine monophosphate (cAMP), and increased by 35% with 10(-8) mol/L phorbol ester [phorbol 12-myristate 13-acetate (PMA), which activates protein kinase C (PKC)]. During luminal perfusion with 10(-11) mol/L AVP, J(K) increased to 0.88 +/- 0.08 nmol. cm(-2).seconds(-1). In the presence of 10(-11) mol/L AVP, J(K) was not affected by 10(-4) mol/L H89, a blocker of protein kinase A (PKA), but was inhibited (45%) by 10(-5) mol/L staurosporine, an inhibitor of PKC, and by 41% during perfusion with 5 x 10(-5) mol/L of the cell Ca2+ chelator bis (2-aminophenoxy) ethane-tetraacetic acid (BAPTA). In order to study the role of Ca2+-dependent K channels in the luminal hormonal action, the tubules were perfused with 5 mmol/L tetraethylammonium chloride (TEA) or 10(-7) mol/L iberiotoxin, in the presence of AVP, and JK was significantly reduced by both agents. Iberiotoxin reduced AVP-stimulated J(K) by 36.4%, and AVP-independent J(K) (after blocking V1 receptors) by only 16%.Conclusion. The results suggest that the luminal V1-receptor effect of AVP on J(K) was mediated by the phospholipase C (PLC)/ Ca2+/PKC signaling path and not by adenylate cyclase/cAMP/PKA, therefore probably acting on maxi-potassium channels.
Resumo:
In this work the thermal lens, thermal relaxation calorimetry and interferometric methods are applied to investigate the thermo-optical properties of tellurite glasses (in mol%: 80TeO(2)-20 Li2O(TeLi), 80TeO(2)-15Li(2)O-5TiO(2) (TeLiTi-5) and 80TeO(2)-10Li(2)O-10TiO(2) (TeLiTi-10)). Thermal diffusivity, thermal conductivity, specific heat and the temperature coefficients of refractive index, optical path length, thermal expansion and electronic polarizability were determined. The use of three independent methods was useful for a complete characterization of the studied tellurite glasses. In addition, our results showed that the thermal expansion coefficient and the temperature coefficient of the optical path length (dS/dT) were significantly modified with the introduction of titanium, which may be relevant for the application of these glasses in the photonic area. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper addresses biometric identification using large databases, in particular, iris databases. In such applications, it is critical to have low response time, while maintaining an acceptable recognition rate. Thus, the trade-off between speed and accuracy must be evaluated for processing and recognition parts of an identification system. In this paper, a graph-based framework for pattern recognition, called Optimum-Path Forest (OPF), is utilized as a classifier in a pre-developed iris recognition system. The aim of this paper is to verify the effectiveness of OPF in the field of iris recognition, and its performance for various scale iris databases. The existing Gauss-Laguerre Wavelet based coding scheme is used for iris encoding. The performance of the OPF and two other - Hamming and Bayesian - classifiers, is compared using small, medium, and large-scale databases. Such a comparison shows that the OPF has faster response for large-scale databases, thus performing better than the more accurate, but slower, classifiers.
Resumo:
Objectives. This paper attempts to provide critical perspectives on common in vitro research methodologies, including shear bond testing, wear testing, and load-to-failure tests. Origins of interest in high-quality laboratory data is reviewed, in vitro data is categorized into property and simulation protocols, and two approaches are suggested for establishing clinical validity. It is hoped that these insights will encourage further progress toward development of in vitro tests that are validated against clinical performance and/or by producing clinically validated failure or damage mechanisms.Materials and methods. Published shear and tensile bond data (macro and micro) is examined in light of published finite element analyses (FEA). This data is subjected to a Weibull scaling analysis to ascertain whether scaling is consistent with failure from the bonded interface or not. Wear tests results are presented in light of the damage mechanism(s) operating. Quantitative wear data is re-examined as being dependent upon contact pressure. Load-to-failure test results are re-analyzed by calculating contact stresses at failure for 119 tests from 54 publications over more than 25 years.Results. FEA analyses and reported failure modes (adhesive, mixed, cohesive) are consistent with failure not involving interfacial "shear stresses" as calculated in published work. Weibull scaling clearly suggests failure involving external surfaces of specimens, not interfacial origins. Contact stresses (pressures) are clearly an important variable in wear testing and are not well-controlled in published work. Load-to-failure tests create damage not seen clinically due to excessively high contact stresses. Most contact stresses in the 119 tests examined were calculated to be between 1000 MPa and 5000 MPa, whereas clinical contact stresses at wear facets have been measured not to exceed 40 MPa.Conclusions. Our community can do a much better job of designing in vitro tests that more closely simulate clinical conditions, especially when contact is involved. Journals are encouraged to thoughtfully consider a ban on publishing papers using bond tests and load-to-failure methods that are seriously flawed and have no clinical relevance. (C) 2011 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Background and objective: The purpose of this study was to analyze histologically the influence of autologous platelet-rich plasma on bone healing in surgically created critical-size defects in rat calvaria.Material adn Methods: Thirty-two rats were divided into two groups: the control group (group C) and the platelet-rich plasma group. An 8-mm-diameter critical-size defect was created in the calvarium of each animal. In group C the defect was filled by a blood clot only. In the platelet-rich plasma group, 0.35 mL of platelet-rich plasma was placed in the defect and covered by 0.35 mL of platelet-poor plasma. Both groups were divided into subgroups (n = 8) and killed at either 4 or 12 wk postoperatively. Histometric (using image-analysis software) and histologic analyses were performed. The amount of new bone formed was calculated as a percentage of the total area of the original defect. Percentage data were transformed into arccosine for statistical analysis (analysis of variance, Tukey, p < 0.05).Results: No defect completely regenerated with bone. The platelet-rich plasma group had a statistically greater amount of bone formation than group C at both 4 wk (17.68% vs. 7.20%, respectively) and 12 wk (24.69% vs. 11.65%, respectively) postoperatively.Conclusion: Within the limits of this study, it can be concluded that platelet-rich plasma placed in the defects and covered by platelet-poor plasma significantly enhanced bone healing in critical-size defects in rat calvaria.
Resumo:
Objective: The present article presents an overview of the literature, and analyses the methods and the primary questions related to assessment of proliferation index using the Ki-67/MIB-1 labeling index in pituitary adenomas. Although atypical adenomas are characterized by their atypical morphological features by an elevated mitotic index, a Ki-67 (MIB-1) labeling index greater than 3% and extensive nuclear staining for p53, use of the proliferation index (LI) of pituitary adenomas in assessing the degree of tumor aggressiveness is a controversial topic in the literature, and there are disparate results involving many studies.Methods: A review of literature was carried out to correlate the role of Ki-67 LI and its correlation with clinical findings, tumor size, invasiveness, recurrence, adenoma subtype, adenoma doubling time, and pituitary carcinomas is addressed. Results: The prognosis cannot be predicted on the basis of the Ki-67 LI alone. Although there is no direct relation between Ki-67 LI and some of these variables and controversial data were found regarding some topics, our review justify the use of Ki-67 in the analysis of pituitary adenomas as an additional information for clinical decision.Conclusion: Although assessment of proliferative may be helpful in predicting subsequent tumor recurrence or invasiveness, there are many other important and as yet unidentified factors pituitary tumors. It is clear that further research is needed to clarify these molecular mechanisms to predict those with a potentially poor clinical outcome.
Resumo:
Majority of biometric researchers focus on the accuracy of matching using biometrics databases, including iris databases, while the scalability and speed issues have been neglected. In the applications such as identification in airports and borders, it is critical for the identification system to have low-time response. In this paper, a graph-based framework for pattern recognition, called Optimum-Path Forest (OPF), is utilized as a classifier in a pre-developed iris recognition system. The aim of this paper is to verify the effectiveness of OPF in the field of iris recognition, and its performance for various scale iris databases. This paper investigates several classifiers, which are widely used in iris recognition papers, and the response time along with accuracy. The existing Gauss-Laguerre Wavelet based iris coding scheme, which shows perfect discrimination with rotary Hamming distance classifier, is used for iris coding. The performance of classifiers is compared using small, medium, and large scale databases. Such comparison shows that OPF has faster response for large scale database, thus performing better than more accurate but slower Bayesian classifier.
Resumo:
Fluconazole, -(2.4-diflurofenil)--(1H-triazol-1-methyl)-1H-1,2,4-triazol-1-ethanol, is an antifungal of triazoles class. It shows activity against species of Candida sp., and it is indicated in cases of oropharyngeal candidiasis, esophageal, vaginal, and deep infection. Fluconazole is a selective inhibitor of ergosterol, a steroid exclusive of the cell membrane of fungal cells. Fluconazole is highly absorbed by the gastrointestinal tract, and it spreads easily by body fluids. The main adverse reactions related to the use of fluconazole are nausea, vomiting, headache, rash, abdominal pain, diarrhea, and alopecia in patients undergoing prolonged treatment with a dose of 400 mg/day. In the form of raw material, pharmaceutical formulations, or biological material, fluconazole can be determined by methods such as titration, spectrophotometry, and thin-layer, gas, and liquid chromatography. This article discusses the pharmacological and physical-chemical properties of fluconazole and also the methods of analysis applied to the determination of the drug.
Resumo:
In this paper we get some lower bounds for the number of critical periods of families of centers which are perturbations of the linear one. We give a method which lets us prove that there are planar polynomial centers of degree l with at least 2[(l - 2)/2] critical periods as well as study concrete families of potential, reversible and Lienard centers. This last case is studied in more detail and we prove that the number of critical periods obtained with our approach does not. increases with the order of the perturbation. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Dynamic light scattering has been used to investigate ternary aqueous solutions of n-dodecyl octaoxyethylene glycol monoetber (C12E8) with high molar mass poly(ethylene oxide) (PEO). The measurements were made at 20 °C, always below the cloud point temperature (Tc) of the mixed solutions. The relaxation time distributions are bimodal at higher PEO and surfactant concentrations, owing to the preacute of free surfactant micelles, which coexist with the slower component, representing the polymer coil/micellar cluster comptex. As the surfactant concentration is increased, the apparent hydrodynamic radius (RH) of the coil becomes progressively larger. It is suggested that the complex structure consists of clusters of micelles sited within the polymer coil, as previously concluded for the PEO-C12E8-water system. However. C12E8 interacts less strongly than C12E8 with PEO; at low concentrations of surfactant the complex does not contribute significantly to the total scattered intensity. The perturbation of the PEO coil radius with C12E8 is also smaller than that in the C12E8 system. The addition of PEO strongly decreases the clouding temperature of the system, as previously observed for C12E8/PEO mixtures in solution Addition of PEO up to 0.2% to C12E8 (10 wt %) solutions doss not alter the aggregation number (Nagg) of the micelles probably because the surfactant monomers are equally partitioned as bound and unbound micelles. The critical micelle concentration (cmc), obtained from the I1/I3 ratio (a measure of the dependence of the vibronic band intensities on the pyrene probe environment), does not change when PEO is added, suggesting that for neutral polymer/surfactant systems the trends in Nagg and the cmc do not unambiguously reflect the strength of interaction.
Resumo:
We determine the critical coupling constant above which dynamical chiral symmetry breaking occurs in a class of QCD motivated models where the gluon propagator has an enhanced infrared behavior. Using methods of bifurcation theory we find that the critical value of the coupling constant is always smaller than the one obtained for QCD. ©2000 The American Physical Society.