1000 resultados para contaminação ambiental
Resumo:
Mestrado em Segurança e Higiene no Trabalho.
Resumo:
OBJETIVO: Avaliar desinfetantes de uso domiciliar, identificando a presença de bactérias contaminantes, e conhecer o nível de tolerância dessas bactérias ao cloreto de benzalcônio. MÉTODOS: Foram adquiridas aleatoriamente no comércio da região metropolitana de São Paulo, SP, Brasil, 52 amostras de desinfetantes de uso domiciliar para análise quanto à presença de bactérias contaminantes. O nível de tolerância dessas bactérias ao cloreto de benzalcônio foi determinado pelo método da macrodiluição em caldo. RESULTADOS: De 52 amostras, 16 (30,77%) estavam contaminadas por bactérias Gram negativas, com contagens variando entre 10(4) e 10(6) UFC/ml. Esses contaminantes foram identificados como Alcaligenes xylosoxidans, Burkholderia cepacia e Serratia marcescens. As Concentrações Inibitórias Mínimas (CIM: mg/ml) do cloreto de benzalcônio para S. marcescens, A. xylosoxidans e B. cepacia foram: 2,48, 1,23 e 0,30, respectivamente. CONCLUSÕES Os desinfetantes de uso domiciliar à base de compostos de amônio quaternário são passíveis de contaminação por bactérias. As CIM do cloreto de benzalcônio para as bactérias contaminantes estavam abaixo das concentrações do princípio ativo presente nos desinfetantes, indicando que a tolerância ao biocida não é estável, podendo ser perdida com o cultivo das bactérias em meios de cultura sem o biocida.
Resumo:
O grande desenvolvimento industrial e científico trouxe inovação nos processos produtivos, diversificação das matérias utilizadas e uma utilização exagerada das mais diversas fontes energéticas. Como sabemos, todos os recursos provêem da natureza e são escassos, ou seja, existe uma utilização limitada, o que poderá levar mesmo à questão da sobrevivência futura de muitas espécies, incluindo a humana. A insistente divulgação de este facto levou a uma consciencialização social do facto, ficando toda a sociedade com essa preocupação. Como as empresas, são um elemento agressor ao meio envolvente, de várias formas: resíduos sólidos, líquidos ou gasosos, e como as empresas estão inseridas na sociedade, também elas terão de ter a preocupação em minimizar ou eliminar por completo o seu impacto no meio envolvente. Assim terão de existir determinados procedimentos que as empresas tomam de forma a atingir este objectivo. No entanto as empresas têm como finalidade o lucro e para isso terão de saber que acções podem tomar e que repercussões existirão para a empresa no médio e longo prazo. É neste âmbito que entramos com a contabilidade ambiental que como factor imprescindível no apoio à gestão, nomeadamente, à tomada de decisões estratégicas e tácticas. Este trabalho terá como finalidade perceber até que ponto as empresas portuguesas utilizam a contabilidade ambiental para controlo e apoio à tomada de decisões relativas à sua política ambiental.
Resumo:
O presente artigo procura apresentar uma revisão da literatura sobre a temática da Contabilidade Ambiental na perspectiva da Divulgação. Efectua-se o enquadramento teórico do tema como suporte para a problemática da motivação da Gestão para o relato ambiental e caracteriza-se o state of the art da divulgação ambiental no relatório anual a nível internacional com particular ênfase para os países onde este assunto tem merecido mais atenção. Depois de apresentado o ponto da situação sobre a realidade portuguesa, antes e após a publicação da Directriz Contabilística nº29 – Matérias Ambientais, é efectuada uma abordagem sobre o papel que cabe aos auditores no processo de reporte de informação no domínio ambiental em face do impacte que estas matérias têm nas demonstrações financeiras.
Resumo:
A descriptive study was developed in order to assess air contamination caused by fungi and particles in seven poultry units. Twenty seven air samples of 25 litters were collected through impaction method. Air sampling and particle concentration measurement were performed in the pavilions’ interior and also outside premises, since this was the place regarded as reference. Simultaneously, temperature and relative humidity were also registered. Regarding fungal load in the air from the seven poultry farms, the highest value obtained was 24040 CFU/m3 and the lowest was 320 CFU/m3. Twenty eight species/genera of fungi were identified, being Scopulariopsis brevicaulis (39.0%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. From the Aspergillus genus, Aspergillus flavus (74.5%) was the most frequently detected species. There was a significant correlation (r=0.487; p=0.014) between temperature and the level of fungal contamination (CFU/m3). Considering contamination caused by particles, in this study, particles with larger dimensions (PM5.0 and PM10) have higher concentrations. There was also a significant correlation between relative humidity and concentration of smaller particles namely, PM0.5 (r=0.438; p=0.025) and PM1.0 (r=0.537; p=0.005). Characterizing typical exposure levels to these contaminants in this specific occupational setting is required to allow a more detailed risk assessment analysis and to set exposure limits to protect workers’ health.
Resumo:
A descriptive study was developed in order to compare indoor and outdoor air contamination caused by fungi and particles in seven poultry units. Twenty eight air samples of 25 litters were collected through the impaction method on malt extract agar. Air sampling and particles concentration measurement were done in the interior and also outside premises of the poultries’ pavilions. Regarding the fungal load in the air, indoor concentration of mold was higher than outside air in six poultry units. Twenty eight species / genera of fungi were identified indoor, being Scopulariopsis brevicaulis (40.5%) the most commonly isolated species and Rhizopus sp. (30.0%) the most commonly isolated genus. Concerning outdoor, eighteen species/genera of fungi were isolated, being Scopulariopsis brevicaulis (62.6%) also the most isolated. All the poultry farms analyzed presented indoor fungi different from the ones identified outdoors. Regarding particles’ contamination, PM2.5, PM5.0 and PM10 had a statistically significant difference (Mann-Whitney U test) between the inside and outside of the pavilions, with the inside more contaminated (p=.006; p=.005; p=.005, respectively). The analyzed poultry units are potential reservoirs of substantial amounts of fungi and particles and could therefore free them in the atmospheric air. The developed study showed that indoor air was more contaminated than outdoors, and this can result in emission of potentially pathogenic fungi and particles via aerosols from poultry units to the environment, which may post a considerable risk to public health and contribute to environmental pollution.
Resumo:
A protecção do meio ambiente e a promoção de um desenvolvimento sustentável têm assumido um papel de crescente importância junto das organizações que, conscientes das suas fragilidades e pressionadas pela opinião pública, têm adoptado sistemas voluntários de acção ambiental. O presente trabalho tem como principal objectivo desenvolver um projecto de planeamento de gestão ambiental tendo por base a norma NP EN ISSO 14001:2004, possibilitando o desenvolvimento e a implementação de um Sistema de Gestão Ambiental numa indústria metalomecânica, para potencial integração com o actual Sistema de Gestão da Qualidade e posterior certificação. Nesse sentido realizou-se uma revisão bibliográfica aos principais conceitos relacionados com o sistema de gestão ambiental, para permitir um melhor entendimento dos requisitos necessários para a concepção do SGA. Posteriormente procedeu-se ao enquadramento da organização face à NP EN ISSO 14001:2004, procedendo-se ao levantamento dos aspectos ambientais da sua actividade e avaliação da sua significância. Foi realizada igualmente a identificação e análise da situação da organização em termos de requisitos legais ambientais. Para os aspectos ambientais significativos foi elaborado o programa de melhoria ambiental, tendo os mesmos sido classificados por prioridades e sempre que aplicável, definiram-se metas e objectivos ou procedimentos de controlo operacional para prevenir, reduzir ou eliminar o respectivo impacte ambiental. Realizou-se ainda um estudo da integração com base na especificação PAS 99:2006 do British Standard Institute, que permitiu concluir que a especificação em si constitui uma boa ferramenta para orientar a integração de sistemas de gestão. Como príncipais benefícios do desenvolvimento e implementação do SGA para a organização, extraimos um controlo eficaz da legislação; uma redução dos impactes ambientais significativos associados às actividades da organização, optimizando os consumos de água e energia e prevenindo a poluição através de uma gestão eficiente no consumo das matérias-pimas e na produção de resíduos. O Sistema Integrado de Gestão de Qualidade e Ambiente em implementação na ARNEG Portuguesa permite atingir benefícios nomeadamente ao nível operacional e burocrático com a integração de procedimentos, processos, estrutura organizacional e responsabilidades.
Resumo:
Although numerous studies have been conducted on microbial contaminants associated with various stages related to poultry and meat products processing, only a few reported on fungal contamination of poultry litter. The goals of this study were to (1) characterize litter fungal contamination and (2) report the incidence of keratinophilic and toxigenic fungi presence. Seven fresh and 14 aged litter samples were collected from 7 poultry farms. In addition, 27 air samples of 25 litters were also collected through impaction method, and after laboratory processing and incubation of collected samples, quantitative colony-forming units (CFU/m3) and qualitative results were obtained. Twelve different fungal species were detected in fresh litter and Penicillium was the most frequent genus found (59.9%), followed by Alternaria (17.8%), Cladosporium (7.1%), and Aspergillus (5.7%). With respect to aged litter, 19 different fungal species were detected, with Penicillium sp. the most frequently isolated (42.3%), followed by Scopulariopsis sp. (38.3%), Trichosporon sp. (8.8%), and Aspergillus sp. (5.5%). A significant positive correlation was found between litter fungal contamination (CFU/g) and air fungal contamination (CFU/m3). Litter fungal quantification and species identification have important implications in the evaluation of potential adverse health risks to exposed workers and animals. Spreading of poultry litter in agricultural fields is a potential public health concern, since keratinophilic (Scopulariopsis and Fusarium genus) as well as toxigenic fungi (Aspergillus, Fusarium, and Penicillium genus) were isolated.
Resumo:
O objetivo do trabalho é analisar dados sobre a real disponibilidade dos recursos hídricos e o reflexo de sua degradação na saúde humana. Visa a acompanhar o crescimento da degradação ambiental nos últimos anos e o fornecimento de dados recentes e confiáveis sobre o tema. Foram abordados os seguintes aspectos: (a) atividades antrópicas e degradação ambiental; (b) estatísticas da disponibilidade e demanda dos recursos hídricos; (c) despejos urbanos e industriais como fontes de contaminação dos recursos hídricos; (d) efeitos deletérios da água contaminada sobre o organismo humano. São alarmantes os valores estatísticos relacionados aos efeitos da água contaminada sobre a saúde humana e ao aumento na demanda dos recursos hídricos. É de importância fundamental a tomada de uma consciência ambientalista por parte das gerações atuais a fim de se evitar o estresse máximo do sistema hídrico, cuja efetivação está prevista para um futuro muito próximo.
Resumo:
Introdução – No caso de uma eventual contaminação radioativa esta deve ser quantificada, pelo que é necessário garantir que as condições de funcionamento de um monitor de contaminação de superfícies se encontrem adequadamente caracterizadas, através da determinação da sua eficiência de deteção. Este estudo tem como objetivo determinar a eficiência de deteção de um monitor de contaminação e analisar a influência da distância e da atividade. Metodologia – O monitor de contaminação Thermo Mini 900E e as fontes radioativas planas de referência de Carbono – 14 (C-14), Césio – 137 (Cs-137), Estrôncio – 90 (Sr-90), Cloro – 36 (Cl-36) e Amerício – 241 (Am-241) com débito de emissão superficial rastreável ao Physikalish Technischen Bundesanstalt (PTB) foram utilizadas. Fontes de Sr-90 e C-14 com dois débitos de emissão distintos para cada e distâncias de 1 a 20mm foram usados para estudar a sua influência na eficiência de deteção. Resultados – Verificou-se que as fontes radioativas emissoras de partículas de maior energia apresentam uma maior eficiência de deteção e que esta diminui com o aumento da distância do detetor à fonte, sendo que os radioisótopos de maior energia apresentam um decréscimo na eficiência de 15% ao longo de 20mm, enquanto os radioisótopos de menor energia apresentam um decréscimo de 10%. Não se verificou uma influência expressiva do débito de emissão na eficiência de deteção deste monitor de contaminação. Conclusão – A eficiência de deteção de um monitor de contaminação portátil é dependente da distância deste à contaminação bem como do tipo de radiação emitida e energia dos radioisótopos presentes na contaminação. - ABSTRACT - Introduction – A radioactive contamination needs to be quantified in case it eventually occurs. Therefore it is necessary to ensure that the operating conditions of a surface contamination monitor are characterized by determining its detection efficiency. This experimental study aims to determine the detection efficiency of a contamination monitor and evaluate the distance and surface emission rate influence on the detection efficiency. Methodology – A contamination monitor Thermo Mini 900E was tested with reference radiation sources of Carbon – 14 (C-14), Cesium – 137 (Cs-137), Strontium – 90 (Sr-90), Chlorine – 36 (Cl-36) and Americium – 241 (Am-241) with its emission rate traced to the Physikalish Technischen Bundesanstalt (PTB). Sources of Sr-90 and C-14 with two different emission rates for each one and distances of 1 to 20mm were used to study its influence in the detection efficiency. Results – With the increasing of distance, the detection efficiency decreases. The most energetic radiation sources have higher detection efficiency, boasting a 15% decrease over 20mm whereas the sources bearing a smaller efficiency decrease 10%. No influence of the surface emission rate in the detection efficiency was verified. Conclusion – Thus, it is concluded that the detection efficiency of a contamination monitor is dependent of the distance between it and the contamination as well as the type and energy of the radioisotopes present in the contamination.
Resumo:
A amplitude e diversidade dos agentes micóticos, fatores de risco profissional de um grupo particular de trabalhadores, é claramente esplanada na revisão bibliográfica que, de uma forma pedagógica e descritiva, refere as características essenciais das espécies fúngicas patogénicas para o Homem, nomeadamente fungos dermatófilos, leveduras e fungos filamentosos não dermatófilos. A prevalência de Tínea pedis e onicomicose, os fatores predisponentes e o contexto profissional dos ginásios com piscina são alvo de análise exaustiva com valorização dos fatores intrínsecos, extrínsecos profissionais e não profissionais e conclui com todo um capítulo dedicado à exposição profissional por via de exposição aérea e por contacto.
Resumo:
OBJETIVO: Analisar o comportamento de pressão arterial (PA) e a freqüência cardíaca (Fc) de indivíduos ao longo da jornada de trabalho em dois ambientes com estresses ambientais distintos. MÉTODOS: Foram avaliados 46 funcionários, trabalhadores de uma indústria processadora de madeira, de Botucatu, SP, sendo 27 funcionários da linha de produção (esforço físico moderado-intenso, altas temperaturas e elevados níveis de ruído) (G1), e 19 da administração (sem esforço físico, salas aclimatadas, baixos níveis de ruído) (G2). Todos foram submetidos a avaliação antropométrica da composição corporal (obesidade e adiposidade) e bioquímica do sangue (lipidemia) e, adicionalmente, o registro da PA e da Fc em três momentos do turno de serviço: início, meio e fim. RESULTADOS: Houve semelhança na variação da PA entre G1 e G2, mas com maiores elevações de PA e Fc em G1. Os resultados mostraram grande variabilidade na resposta da PA, levando à subdivisão dos grupos G1 e G2 em respondedores (GR, aumento maior de 10% na PA média) e não respondedores (GN). Os subgrupos GR e GN apresentaram semelhanças nos padrões antropométrico e bioquímico diferindo apenas na resposta pressórica e no caso do GR1 na história familiar de hipertensão. Comparando os subgrupos GR1 e GR2, foi constatado que os primeiros apresentaram maiores variações de PA e Fc que os segundos. CONCLUSÕES: A variação individual da resposta pressórica e da Fc conforme o tipo de estresse ambiental indica ser este um fator adicional a ser considerado na avaliação da pressão arterial e, talvez, na gênese da hipertensão arterial de operários.
Resumo:
A proliferação de resíduos que contribuem para a contaminação dos solos e águas, bem como as emissões de gases que contribuem para o efeito de estufa, tornou-se, nas últimas décadas, um problema importante a ser resolvido. A adoção de estratégias relacionadas com um desenvolvimento autossustentável motivou o desenvolvimento deste trabalho para uma instituição de ensino secundário, tentando mudar atitudes. As técnicas de tratamento de resíduos apresentam um alto custo e a necessidade de pessoal treinado, tornando-se desvantajosas em relação às técnicas de redução na fonte. Neste contexto, este trabalho tem como proposta a elaboração de um guia a adotar na gestão de resíduos laboratoriais de uma escola secundária. Neste guia identificam-se as atividades laboratoriais mais poluentes através da Estrela de Verdura (EV), propõem-se procedimentos de gestão dos resíduos gerados e sugerem-se atividades pedagógicas mais sustentáveis. Assim após um enquadramento teórico do ensino experimental da química e suas relações com o Ambiente ao longo do século XX, descrevem-se as finalidades e dificuldades da aplicação da Química Verde (QV) nas atividades laboratoriais. Sugere-se um sistema de gestão de resíduos otimizado. Apresenta-se o guia de gestão através da implementação da QV e da microescala, onde se identificam as atividades laboratoriais mais problemáticas em termos de segurança ambiental e propõem-se alternativas que podem vir a mudar a postura do ensino da química. Finalmente, em função das análises realizadas, concluiu-se que se conseguem realizar as atividades laboratoriais de uma forma mais benigna, sem prejuízo dos objetivos didáticos e com elevada rentabilidade económica, graças ao uso sustentado da tecnologia disponível.
Resumo:
Orientador: Mestre, António Pinto Marques