966 resultados para cancer detection


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Only responding patients benefit from preoperative therapy for locally advanced esophageal carcinoma. Early detection of non-responders may avoid futile treatment and delayed surgery. PATIENTS AND METHODS: In a multi-center phase ll trial, patients with resectable, locally advanced esophageal carcinoma were treated with 2 cycles of induction chemotherapy followed by chemoradiotherapy (CRT) and surgery. Positron emission tomography with 2[fluorine-18]fluoro-2-deoxy-d-glucose (FDG-PET) was performed at baseline and after induction chemotherapy. The metabolic response was correlated with tumor regression grade (TRG). A decrease in FDG tumor uptake of less than 40% was prospectively hypothesized as a predictor for histopathological non-response (TRG > 2) after CRT. RESULTS: 45 patients were included. The median decrease in FDG tumor uptake after chemotherapy correlated well with TRG after completion of CRT (p = 0.021). For an individual patient, less than 40% decrease in FDG tumor uptake after induction chemotherapy predicted histopathological non-response after completion of CRT, with a sensitivity of 68% and a specificity of 52% (positive predictive value 58%, negative predictive value 63%). CONCLUSIONS: Metabolic response correlated with histopathology after preoperative therapy. However, FDG-PET did not predict non-response after induction chemotherapy with sufficient clinical accuracy to justify withdrawal of subsequent CRT and selection of patients to proceed directly to surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: Pelvic lymph node dissection (PLND) is considered the most reliable procedure for the detection of lymph node metastases in prostate cancer (PCa); however, the therapeutic benefit of PLND in PCa management is currently under debate. OBJECTIVE: To systematically review the available literature concerning the role of PLND and its extent in PCa staging and outcome. All of the existing recommendations and staging tools determining the need for PLND were also assessed. Moreover, a systematic review was performed of the long-term outcome of node-positive patients stratified according to the extent of nodal invasion. EVIDENCE ACQUISITION: A Medline search was conducted to identify original and review articles as well as editorials addressing the significance of PLND in PCa. Keywords included prostate cancer, pelvic lymph node dissection, radical prostatectomy, imaging, and complications. Data from the selected studies focussing on the role of PLND in PCa staging and outcome were reviewed and discussed by all of the contributing authors. EVIDENCE SYNTHESIS: Despite recent advances in imaging techniques, PLND remains the most accurate staging procedure for the detection of lymph node invasion (LNI) in PCa. The rate of LNI increases with the extent of PLND. Extended PLND (ePLND; ie, removal of obturator, external iliac, hypogastric with or without presacral and common iliac nodes) significantly improves the detection of lymph node metastases compared with limited PLND (lPLND; ie, removal of obturator with or without external iliac nodes), which is associated with poor staging accuracy. Because not all patients with PCa are at the same risk of harbouring nodal metastases, several nomograms and tables have been developed and validated to identify candidates for PLND. These tools, however, are based mostly on findings derived from lPLND dissections performed in older patient series. According to these prediction models, a staging PLND might be omitted in low-risk PCa patients because of the low rate of lymph node metastases found, even after extended dissections (<8%). The outcome for patients with positive nodes is not necessarily poor. Indeed, patients with low-volume nodal metastases experience excellent survival rates, regardless of adjuvant treatment. But despite few retrospective studies reporting an association between PLND and PCa progression and survival, the exact impact of PLND on patient outcomes has not yet been clearly proven because of the lack of prospective randomised trials. CONCLUSIONS: On the basis of current data, we suggest that if a PLND is indicated, then it should be extended. Conversely, in view of the low rate of LNI among patients with low-risk PCa, a staging ePLND might be spared in this patient category. Whether this approach is also safe from oncologic perspectives is still unknown. Patients with low-volume nodal metastases have a good long-term prognosis; to what extent this prognosis is the result of a positive impact of PLND on PCa outcomes is still to be determined.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CONTEXT: The presence of lymph node metastases and the extent of lymphadenectomy have both been shown to influence the outcome of patients with muscle-invasive bladder cancer. OBJECTIVE: Current standards for detection of lymph node metastases, lymph-node mapping studies, histopathologic techniques, and risk factors in relation to lymph node involvement are discussed. The impact of lymph node metastases and the extent of lymphadenectomy on the outcome of patients treated with radical cystectomy are analyzed. EVIDENCE ACQUISITION: A systematic literature review of bladder cancer and lymph nodes was performed searching the electronic databases Pubmed/Medline, Cochrane, and Embase. Articles were selected based on title, abstract, study format, and content by a consensus of all participating authors. EVIDENCE SYNTHESIS: Lymph node status is highly consequential in bladder cancer patients because the presence of lymph node metastases is predictive of poor outcome. Knowledge of primary landing sites of lymph node metastases is important for optimum therapeutic management. Accurate pathologic work-ups of resected lymph node tissue are mandatory. Molecular markers could potentially guide therapeutic decisions in the future because they may enable the detection of micrometastatic disease. In current series, radical cystectomy with an extended lymphadenectomy seems to provide a clinically meaningful therapeutic benefit compared with a limited approach. However, the anatomic boundaries of lymph node dissection are still under debate. Therefore, large prospective multicenter trials are needed to validate the influence of extended lymph node dissection on disease-specific survival. CONCLUSIONS: An extended pelvic lymph node dissection (encompassing the external iliac vessels, the obturator fossa, the lateral and medial aspects of the internal iliac vessels, and at least the distal half of the common iliac vessels together with its bifurcation) can be curative in patients with metastasis or micrometastasis to a few nodes. Therefore, the procedure may be offered to all patients undergoing radical cystectomy for invasive bladder cancer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Even though complete resection is regarded as the only curative treatment for nonsmall cell lung cancer (NSCLC), >50% of resected patients die from a recurrence or a second primary tumour of the lung within 5 yrs. It remains unclear, whether follow-up in these patients is cost-effective and whether it can improve the outcome due to early detection of recurrent tumour. The benefit of regular follow-up in a consecutive series of 563 patients, who had undergone potentially curative resection for NSCLC at the University Hospital, was analysed. The follow-up consisted of clinical visits and chest radiography according to a standard protocol for up to 10 yrs. Survival rates were estimated using the Kaplan-Meier analysis method and the cost-effectiveness of the follow-up programme was assessed. A total of 23 patients (6.4% of the group with lobectomy) underwent further operation with curative intent for a second pulmonary malignancy. The regular follow-up over a 10-yr period provided the chance for a second curative treatment to 3.8% of all patients. The calculated costs per life-yr gained were 90,000 Swiss Francs. The cost-effectiveness of the follow-up protocol was far above those of comparable large-scale surveillance programmes. Based on these data, the intensity and duration of the follow-up was reduced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Reporting and publication bias is a well-known problem in meta-analysis and healthcare research. In 2002 we conducted a meta-analysis on the effects of erythropoiesis-stimulating agents (ESAs) on overall survival in cancer patients, which suggested some evidence for improved survival in patients receiving ESAs compared with controls. However, a meta-analysis of individual patient data conducted several years later showed the opposite of our first meta-analysis, that is, evidence for increased on-study mortality and reduced overall survival in cancer patients receiving ESAs. We aimed to determine whether the results of our first meta-analysis could have been affected by publication and reporting biases and, if so, whether timely access to clinical study reports and individual patient data could have prevented this. We conducted a hypothetical meta-analysis for overall survival including all studies and study data that could have been available in 2002, at the time when we conducted our first meta-analysis. Compared with our original meta-analysis, which suggested an overall survival benefit for cancer patients receiving ESAs [hazard ratio (HR) 0.81, 95% confidence interval (CI) 0.67‒0.99], our hypothetical meta-analysis based on the results of all studies conducted at the time of the first analysis did not show evidence for a beneficial effect of ESAs on overall survival (HR 0.97, 95% CI 0.83‒1.12). Thus we have to conclude that our first meta-analysis showed misleading overall survival benefits due to publication and reporting biases, which could have been prevented by timely access to clinical study reports and individual patient data. Unrestricted access to clinical study protocols including amendments, clinical study reports and individual patient data is needed to ensure timely detection of both beneficial and harmful effects of healthcare interventions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Early detection of colorectal cancer through timely follow-up of positive Fecal Occult Blood Tests (FOBTs) remains a challenge. In our previous work, we found 40% of positive FOBT results eligible for colonoscopy had no documented response by a treating clinician at two weeks despite procedures for electronic result notification. We determined if technical and/or workflow-related aspects of automated communication in the electronic health record could lead to the lack of response. METHODS: Using both qualitative and quantitative methods, we evaluated positive FOBT communication in the electronic health record of a large, urban facility between May 2008 and March 2009. We identified the source of test result communication breakdown, and developed an intervention to fix the problem. Explicit medical record reviews measured timely follow-up (defined as response within 30 days of positive FOBT) pre- and post-intervention. RESULTS: Data from 11 interviews and tracking information from 490 FOBT alerts revealed that the software intended to alert primary care practitioners (PCPs) of positive FOBT results was not configured correctly and over a third of positive FOBTs were not transmitted to PCPs. Upon correction of the technical problem, lack of timely follow-up decreased immediately from 29.9% to 5.4% (p<0.01) and was sustained at month 4 following the intervention. CONCLUSION: Electronic communication of positive FOBT results should be monitored to avoid limiting colorectal cancer screening benefits. Robust quality assurance and oversight systems are needed to achieve this. Our methods may be useful for others seeking to improve follow-up of FOBTs in their systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Autofluorescence imaging is used widely for diagnostic evaluation of various epithelial malignancies. Cancerous lesions display loss of autofluorescence due to malignant changes in epithelium and subepithelial stroma. Carcinoma of unknown primary site presents with lymph node or distant metastasis, for which the site of primary tumour is not detectable. We describe here the use of autofluorescence imaging for detecting a clinically innocuous appearing occult malignancy of the palate which upon pathological examination was consistent with a metastatic squamous cell carcinoma. CASE DESCRIPTION: A submucosal nodule was noted on the right posterior hard palate of a 59-year-old white female during clinical examination. Examination of this lesion using a multispectral oral cancer screening device revealed loss of autofluorescence at 405 nm illumination. An excisional biopsy of this nodule, confirmed the presence of a metastatic squamous cell carcinoma. Four years ago, this patient was diagnosed with metastatic squamous cell carcinoma of the right mid-jugular lymph node of unknown primary. She was treated with external beam irradiation and remained disease free until current presentation. CONCLUSION: This case illustrates the important role played by autofluorescence tissue imaging in diagnosing a metastatic palatal tumour that appeared clinically innocuous and otherwise would not have been biopsied.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring 5-FU plasma levels in cancer patients in our routine clinical practice. METHODS: Performance of the Saladax My5-FU™ immunoassay was evaluated on the Roche Cobas® Integra 800 analyzer. Subsequently, 5-FU concentrations of 247 clinical plasma samples obtained with this assay were compared to the results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and other commonly used clinical analyzers (Olympus AU400, Roche Cobas c6000, and Thermo Fisher CDx90). RESULTS: The My-FU assay was successfully validated on the Cobas Integra 800 analyzer in terms of linearity, precision, accuracy, recovery, interference, sample carryover, and dilution integrity. Method comparison between the Cobas Integra 800 and LC-MS/MS revealed a proportional bias of 7% towards higher values measured with the My5-FU assay. However, when the Cobas Integra 800 was compared to three other clinical analyzers in addition to LC-MS/MS including 50 samples representing the typical clinical range of 5-FU plasma concentrations, only a small proportional bias (≤1.6%) and a constant bias below the limit of detection was observed. CONCLUSIONS: The My5-FU assay demonstrated robust and highly comparable performance on different analyzers. Therefore, the assay is suitable for monitoring 5-FU plasma levels in routine clinical practice and may contribute to improved efficacy and safety of commonly used 5-FU-based chemotherapies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Apoptosis, a form of programmed cell death, is critical to homoeostasis, normal development, and physiology. Dysregulation of apoptosis can lead to the accumulation of unwanted cells, such as occurs in cancer, and the removal of needed cells or disorders of normal tissues, such as heart, neurodegenerative, and autoimmune diseases. Noninvasive detection of apoptosis may play an important role in the evaluation of disease states and response to therapeutic intervention for a variety of diseases. It is desirable to have an imaging method to accurately detect and monitor this process in patients. In this study, we developed annexin A5-conjugated polymeric micellar nanoparticles dual-labeled with a near-infrared fluorescence fluorophores (Cy7) and a radioisotope (111In), named as 111In-labeled annexin A5-CCPM. In vitro studies demonstrated that annexin A5-CCPM could strongly and specifically bind to apoptotic cells. In vivo studies showed that apoptotic tissues could be clearly visualized by both single photon emission computed tomography (SPECT) and fluorescence molecular tomography (FMT) after intravenous injection of 111In-labeled Annexin A5-CCPM in 6 different apoptosis models. In contrast, there was little signal in respective healthy tissues. All the biodistribution data confirmed imaging results. Moreover, histological analysis revealed that radioactivity count correlated with fluorescence signal from the nanoparticles, and both signals co-localized with the region of apoptosis. In sum, 111In-labeled annexin A5-CCPM allowed visualization of apoptosis by both nuclear and optical imaging techniques. The complementary information acquired with multiple imaging techniques should be advantageous in improving diagnostics and management of patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Breast cancer is the most common malignancy among women in the world. Its 5-year survival rate ranges from 23.4% in patients with stage IV to 98% in stage I disease, highlighting the importance of early detection and diagnosis. 18F-2-Fluoro-2-deoxy-glucose (18F-FDG), using positron emission tomography (PET), is the most common functional imaging tool for breast cancer diagnosis currently. Unfortunately, 18F-FDG-PET has several limitations such as poorly differentiating tumor tissues from inflammatory and normal brain tissues. Therefore, 18F-labeled amino acid-based radiotracers have been reported as an alternative, which is based on the fact that tumor cells uptake and consume more amino acids to sustain their uncontrolled growth. Among those radiotracers, 18F-labeled tyrosine and its derivatives have shown high tumor uptake and great ability to differentiate tumor tissue from inflammatory sites in brain tumors and squamous cell carcinoma. They enter the tumor cells via L-type amino acid transporters (LAT), which were reported to be highly expressed in many cancer cell lines and correlate positively with tumor growth. Nevertheless, the low radiosynthesis yield and demand of an on-site cyclotron limit the use of 18F-labeled tyrosine analogues. In this study, four Technetium-99m (99mTc) labeled tyrosine/ AMT (α-methyl tyrosine)-based radiotracers were successfully synthesized and evaluated for their potentials in breast cancer imaging. In order to radiolabel tyrosine and AMT, the chelators N,N’-ethylene-di-L-cysteine (EC) and 1,4,8,11-tetra-azacyclotetradecane (N4 cyclam) were selected to coordinate 99mTc. These chelators have been reported to provide stable chelation ability with 99mTc. By using the chelator technology, the same target ligand could be labeled with different radioisotopes for various imaging modalities for tumor diagnosis, or for internal radionuclide therapy in future. Based on the in vitro and in vivo evaluation using the rat mammary tumor models, 99mTc-EC-AMT is considered as the most suitable radiotracer for breast cancer imaging overall, however, 99mTc-EC-Tyrosine will be more preferred for differential diagnosis of tumor from inflammation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

EphB4 receptors, a member of the largest family of receptor tyrosine kinases, are found over-expressed in a variety of tumors cells including glioma cells as well as angiogenic blood vessels. Noninvasive imaging of EphB4 could potentially increase early detection rates, monitor response to therapy directed against EphB4, and improve patient outcomes. Targeted delivery of EphB4 receptor specific peptide conjugated hollow gold nanoshells (HAuNS) into tumors has great potential in cancer imaging and photothermal therapy. In this study, we developed an EphB4 specific peptide named TNYL-RAW and labeled with radioisotope 64Cu and Cy5.5 dye. We also conjugate this specific peptide with hollow gold nanoshells (HAuNS) to evaluate targeted photothermal therapy of cancers. In vitro, 64Cu-DOTA-TNYL- RAW specifically bind to CT26 and PC-3M cells but not to A549 cells. In vivo, Small-animal PET/CT clearly showed the significant uptake of 64Cu-DOTA-TNYL-RAW in CT26 and PC-3M tumors but not in A549 tumors. Furthermore, µPET/CT and near-infrared optical imaging clearly showed the uptake of the dual labeled TNYL-RAW peptide in both U251 and U87 tumors in the brains of nude mice. In U251 tumors, Cy5.5-labeled peptide can bind to EphB4-expressing tumor blood vessels and tumors cells. But in U87 models, dual labeled peptide only could bind to tumor associated blood vessels. Also, Irradiation of PC-3M and CT-26 cell treated with TNYL-PEG-HAuNS nanopatilces with near-infrared (NIR) laser resulted in selective destruction of these cells in vitro. EphB4 targeted TNYL-PEG-HAuNS showed more photothermal killing effect on CT26 tumor model than PEG-HAuNS did. In summary, tumors with overexpression of EphB4 receptors can be noninvasively visualized by micro PET/CT with 64Cu labeled or dual labeled TNYL-RAW peptide. Targeted delivery of TNYL-RAW conjugated HAuNS into tumors can greatly improve the treatment effect of photothermal therapy. The information acquired with this study should be advantageous in improving diagnostics and future applications in photothermal ablation therapy in clinical.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The aim of this phantom study was to minimize the radiation dose by finding the best combination of low tube current and low voltage that would result in accurate volume measurements when compared to standard CT imaging without significantly decreasing the sensitivity of detecting lung nodules both with and without the assistance of CAD. METHODS An anthropomorphic chest phantom containing artificial solid and ground glass nodules (GGNs, 5-12 mm) was examined with a 64-row multi-detector CT scanner with three tube currents of 100, 50 and 25 mAs in combination with three tube voltages of 120, 100 and 80 kVp. This resulted in eight different protocols that were then compared to standard CT sensitivity (100 mAs/120 kVp). For each protocol, at least 127 different nodules were scanned in 21-25 phantoms. The nodules were analyzed in two separate sessions by three independent, blinded radiologists and computer-aided detection (CAD) software. RESULTS The mean sensitivity of the radiologists for identifying solid lung nodules on a standard CT was 89.7% ± 4.9%. The sensitivity was not significantly impaired when the tube and current voltage were lowered at the same time, except at the lowest exposure level of 25 mAs/80 kVp [80.6% ± 4.3% (p = 0.031)]. Compared to the standard CT, the sensitivity for detecting GGNs was significantly lower at all dose levels when the voltage was 80 kVp; this result was independent of the tube current. The CAD significantly increased the radiologists' sensitivity for detecting solid nodules at all dose levels (5-11%). No significant volume measurement errors (VMEs) were documented for the radiologists or the CAD software at any dose level. CONCLUSIONS Our results suggest a CT protocol with 25 mAs and 100 kVp is optimal for detecting solid and ground glass nodules in lung cancer screening. The use of CAD software is highly recommended at all dose levels.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Progress in the detection and treatment of cancer has led to an impressive reduction in both mortality and morbidity. Due to their mechanism of action, however, conventional chemotherapeutics and some of the newer anti-cancer signaling inhibitors carry a substantial risk of cardiovascular side effects that include cardiac dysfunction and heart failure, arterial hypertension, vasospastic and thromboembolic ischaemia, dysrhythmia, and QT prolongation. While some of these side effects are irreversible and cause progressive cardiovascular disease, others induce only temporary dysfunction with no apparent long-term sequelae for the patient. The challenge for the cardiovascular specialist is to balance the need for life-saving cancer treatment with the assessment of risk from cancer drug-associated cardiovascular side effects to prevent long-term damage. This review discusses concepts for timely diagnosis, intervention, and surveillance of cancer patients undergoing treatment, and provides approaches to clinical uncertainties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

While cancer is one of the greatest challenges to public health care, prostate cancer was chosen as cancer model to develop a more accurate imaging assessment than those currently available. Indeed, an efficient imaging technique which considerably improves the sensitivity and specificity of the diagnostic and predicting the cancer behavior would be extremely valuable. The concept of optoacoustic imaging using home-made functionalized gold nanoparticles coupled to an antibody targeting PSMA (prostate specific membrane antigen) was evaluated on different cancer cell lines to demonstrate the specificity of the designed platform. Two commonly used microscopy techniques (indirect fluorescence and scanning electron microscopy) showed their straightforwardness and versatility for the nanoparticle binding investigations regardless the composition of the investigated nanoobjects. Moreover most of the research laboratories and centers are equipped with fluorescence microscopes, so indirect fluorescence using Quantum dots can be used for any active targeting nanocarriers (polymers, ceramics, metals, etc.). The second technique based on backscattered electron is not only limited to gold nanoparticles but also suits for any study of metallic nanoparticles as the electronic density difference between the nanoparticles and binding surface stays high enough. Optoacoustic imaging was finally performed on a 3D cellular model to assess and prove the concept of the developed platform.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of our study was to evaluate the quality of histo- and cytomorphological features of PAXgene-fixed specimens and their suitability for histomorphological classification in comparison to standard formalin fixation. Fifteen colon cancer tissues were collected, divided into two mirrored samples and either formalin fixed (FFPE) or PAXgene fixed (PFPE) before paraffin embedding. HE- and PAS-stained sections were scanned and evaluated in a blinded, randomised ring trial by 20 pathologists from Europe and the USA using virtual microscopy. The pathologists evaluated histological grading, histological subtype, presence of adenoma, presence of lymphovascular invasion, quality of histomorphology and quality of nuclear features. Statistical analysis revealed that the reproducibility with regard to grading between both fixation methods was rather satisfactory (weighted kappa statistic (k w) = 0.73 (95 % confidence interval (CI), 0.41-0.94)), with a higher agreement between the reference evaluation and the PFPE samples (k w = 0.86 (95 % CI, 0.67-1.00)). Independent from preservation method, inter-observer reproducibility was not completely satisfactory (k w = 0.60). Histomorphological quality parameters were scored equal or better for PFPE than for FFPE samples. For example, overall quality and nuclear features, especially the detection of mitosis, were judged significantly better for PFPE cases. By contrast, significant retraction artefacts were observed more frequently in PFPE samples. In conclusion, our findings suggest that the PAXgene Tissue System leads to excellent preservation of histomorphology and nuclear features of colon cancer tissue and allows routine morphological diagnosis.