899 resultados para air-lift pump
Resumo:
Comprend : Mémoire sur la topographie médicale et sur les maladies épidémiques de l'île Minorque, traduit de l'anglais
Resumo:
During the first hours after release of petroleum at sea, crude oil hydrocarbons partition rapidly into air and water. However, limited information is available about very early evaporation and dissolution processes. We report on the composition of the oil slick during the first day after a permitted, unrestrained 4.3 m(3) oil release conducted on the North Sea. Rapid mass transfers of volatile and soluble hydrocarbons were observed, with >50% of ≤C17 hydrocarbons disappearing within 25 h from this oil slick of <10 km(2) area and <10 μm thickness. For oil sheen, >50% losses of ≤C16 hydrocarbons were observed after 1 h. We developed a mass transfer model to describe the evolution of oil slick chemical composition and water column hydrocarbon concentrations. The model was parametrized based on environmental conditions and hydrocarbon partitioning properties estimated from comprehensive two-dimensional gas chromatography (GC×GC) retention data. The model correctly predicted the observed fractionation of petroleum hydrocarbons in the oil slick resulting from evaporation and dissolution. This is the first report on the broad-spectrum compositional changes in oil during the first day of a spill at the sea surface. Expected outcomes under other environmental conditions are discussed, as well as comparisons to other models.
Resumo:
This paper estimates a model of airline competition for the Spanish air transport market. I test the explanatory power of alternative oligopoly models with capacity constraints. In addition, I analyse the degree of density economies. Results show that Spanish airlines conduct follows a price-leadership scheme so that it is less competitive than the Cournot solution. I also find evidence that thin routes can be considered as natural monopolies
Resumo:
RJ 2.2.5 is a human B cell line that has lost the capacity to express MHC class II genes. The human class II-positive phenotype is restored in somatic cell hybrids between RJ 2.2.5 and mouse spleen cells. By karyotype and molecular studies of an informative family of hybrids we have now shown that the reexpression of human class II gene products, as well as the maintenance of the mouse class II-positive phenotype, correlates with the presence of mouse chromosome 16. Thus, the existence on this mouse chromosome of a newly found locus, designated by us aIr-1, that determines a trans-acting activator function for class II gene expression, is established. Possible implications of this finding are discussed.
Resumo:
Concrete will suffer frost damage when saturated and subjected to freezing temperatures. Frost-durable concrete can be produced if a specialized surfactant, also known as an air-entraining admixture (AEA), is added during mixing to stabilize microscopic air voids. Small and well-dispersed air voids are critical to produce frost-resistant concrete. Work completed by Klieger in 1952 found the minimum volume of air required to consistently ensure frost durability in a concrete mixture subjected to rapid freezing and thawing cycles. He suggested that frost durability was provided if 18 percent air was created in the paste. This is the basis of current practice despite the tests being conducted on materials that are no longer available using tests that are different from those in use today. Based on the data presented, it was found that a minimum air content of 3.5 percent in the concrete and 11.0 percent in the paste should yield concrete durable in the ASTM C 666 with modern AEAs and low or no lignosulfonate water reducers (WRs). Limited data suggests that mixtures with a higher dosage of lignosulfonate will need about 1 percent more air in the concrete or 3 percent more air in the paste for the materials and procedures used. A spacing factor of 0.008 in. was still found to be necessary to provide frost durability for the mixtures investigated.
Resumo:
[Traditions. Asie. Turquie]
Resumo:
Iowa's secondary roads contain nearly 15,000 bridges which are less than 40 ft (12.2 m) in length. Many of these bridges were built several decades ago and need to be replaced. Box culvert construction has proven to be an adequate bridge replacement technique. Recently a new bridge replacement alternative, called the Air-O-Form method, has emerged which has several potential advantages over box culvert construction. This new technique uses inflated balloons as the interior form in the construction of an arch culvert. Concrete was then shotcreted onto the balloon form. The objective of research project HR-313 was to construct an air formed arch culvert to determine the applicability of the Air-O-Form technique as a county bridge replacement alternative. The project had the following results: The Air-O-Form method can be used to construct a structurally sound arch culvert; and the method must become more economical if it is to compete with box culverts. Continued monitoring should be conducted in order to evaluate the long-term performance of the Air-O-Form method.
Resumo:
Iowa's secondary road network contains nearly 15,000 bridges which are less than 12 m (40 ft) long. Many of these bridges were built several decades ago and need to be replaced. Box culvert construction has proven to be an adequate bridge replacement technique. An alternative to box culverts is the Air-O-Form method of arch culvert construction. The Air-O-Form method has several potential advantages over box culvert construction. The new technique uses inflated balloons as the interior form in the construction of an arch culvert. Concrete is then shotcreted onto the balloon form to complete the arch culvert. The objective of the research project was to construct an air formed arch culvert to determine its applicability as an alternative county bridge replacement technique. The project had the following results: (1) The Air-O-Form method can be used to construct a structurally sound arch culvert; and (2) The method must become more economical if it is to compete with box culverts.
Resumo:
RESUME Introduction: Les inhibiteurs de la pompe à protons sont actuellement considérés comme les médicaments de choix pour le traitement des affections peptiques comme l'ulcère gastroduodénal et l'oesophagite de reflux. La rapidité, ainsi que le degré d'inhibition de la sécrétion gastrique acide sont importants pour le contrôle optimal des symptômes ainsi que pour le traitement de ces affections. But : Le but principal de cette étude a été de comparer, chez les sujets asymptomatiques non infectés par H. pylori, par pH-métrie intragastrique de 24 heures, la rapidité et la durée de l'action antisécrétoire de doses uniques de rabéprazole 20 mg, d'oméprazole capsule 20 mg, d'oméprazole en comprimé MUPS (« Multiple Unit Pellet System ») 20 mg, de pantoprazole 40 mg et de lansoprazole 30 mg, respectivement. Matériel et méthodes : Cette étude, effectuée en double aveugle et randomisée, a été conduite de manière croisée chez 18 sujets H. pylori-négatifs. Une pH-métrie de 24 heures a été effectuée le jour de l'administration du médicament (dose unique de rabéprazole 20 mg, de lansoprazole 30mg, de pantoprazole 40 mg, d'oméprazole capsule 20 mg, d'oméprazole MUPS comprimé 20mg, ou de placebo). Résultats : Le pH intragastrique médian (3.4 vs. 2.9, 2.2, 1.9 et 1.8, respectivement; p≤ 0.03) et le temps avec un pH supérieur à 4 pendant les 24 heures suivant la prise du médicament (8.0 heures vs. 7.4, 4.9, 2.9, et 3.0, respectivement; p≤ 0.003) ont été statistiquement plus élevés avec le rabéprazole qu'avec le lansoprazole, le pantoprazole, l'oméprazole capsule, l'oméprazole comprimé MUPS, ou le placebo. Les valeurs du pH pendant les périodes diurnes et nocturnes étaient plus hautes avec le rabeprazole et le lansoprazole qu'avec le pantoprazole, l'oméprazole capsule, et l'oméprazole comprimé MUPS (p≤0.04). Conclusion : Le rabéprazole s'est montré le plus efficace de tous les inhibiteurs de pompe à protons étudiés durant le premier jour de l'administration du médicament. SUMMARY Background: Rapid and consistent acid suppression on the first day of dosing may be important in treating acid-related disorders. Aim: To compare the antisecretory activity and onset of action of single doses of rabeprazole, lansoprazole, pantoprazole, omeprazole capsule, omeprazole multiple unit pellet system (MUPS) tablet and placebo in healthy Helicobacter pylori-negative subjects. Methods: This cross-over, double-blind, randomized study was performed in 18 H. pylori-negative subjects. Twenty-four-hour intragastric pH monitoring was performed on the day of treatment (once-daily dose of rabeprazole 20 mg, lansoprazole 30 mg, pantoprazole 40 mg, omeprazole capsule 20 mg, omeprazole MUPS tablet 20 mg or placebo). Results: The intragastric pH (3.4) and time at pH > 4 during the 24 h post-dose (8.0 h) were significantly greater with rabeprazole than with lansoprazole, pantoprazole, omeprazole capsule, omeprazole MUPS tablet or placebo (P ≤ 0.04 for rabeprazole vs. the others). Daytime and night-time pH values were higher with rabeprazole and lansoprazole than with pantoprazole, omeprazole capsule and omeprazole MUPS tablet (P ≤ 0.04). Conclusion: Rabeprazole was the most potent acid inhibitor of all the proton pump inhibitors tested during the first day of dosing.
Resumo:
This report discusses the asphalt pavement recycling project designated Project HR-188 in Kossuth County, Iowa. Specific objectives were: (a) to determine the effectiveness of drum mixing plant modifications designed to control air pollution within limits specified by the Iowa Department of Environmental Quality; (b) to assess the impact of varying the proportions of recycled and virgin aggregates, (c) to assess the impact of varying the production rate of the plant, and (d) to assess the impact of varying the mixing temperature. The discussion includes information on the proposed use of research funds, project location and description, the project planning conference, plan development, bid letting, asphalt plant configuration, actual plant operation, why this method is successful, probable process limitations, pollution results, recycled pavement test results, and the cost of virgin vs. recycled asphalt pavements.