586 resultados para acústica
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The present study aimed to compare elderly and young female voices in habitual and high intensity. The effect of increased intensity on the acoustic and perceptual parameters was assessed. Sound pressure level, fundamental frequency, jitter, shimmer, and harmonic to noise ratio were obtained at habitual and high intensity voice in a group of 30 elderly women and 30 young women. Perceptual assessment was also performed. Both groups demonstrated an increase in sound pressure level and fundamental frequency from habitual voice to high intensity voice. No differences were found between groups in any acoustic variables on samples recorded with habitual intensity level. No significant differences between groups were found in habitual intensity level for pitch, hoarseness, roughness, and breathiness. Asthenia and instability obtained significant higher values in elderly than young participants, whereas, the elderly demonstrated lower values for perceived tension and loudness than young subjects. Acoustic and perceptual measures do not demonstrate evident differences between elderly and young speakers in habitual intensity level. The parameters analyzed may lack the sensitivity necessary to detect differences in subjects with normal voices. Phonation with high intensity highlights differences between groups, especially in perceptual parameters. Therefore, high intensity should be included to compare elderly and young voice.
The importance of retesting the hearing screening as an indicator of the real early hearing disorder
Resumo:
Early diagnosis of hearing loss minimizes its impact on child development. We studied factors that influence the effectiveness of screening programs. To investigate the relationship between gender, weight at birth, gestational age, risk factors for hearing loss, venue for newborn hearing screening and pass and fail results in the retest. Prospective cohort study was carried out in a tertiary referral hospital. The screening was performed in 565 newborns through transient evoked otoacoustic emissions in three admission units before hospital discharge and retest in the outpatient clinic. Gender, weight at birth, gestational age, presence of risk indicators for hearing loss and venue for newborn hearing screening were considered. Full-term infants comprised 86% of the cases, preterm 14%, and risk factors for hearing loss were identified in 11%. Considering the 165 newborns retested, only the venue for screening, Intermediate Care Unit, was related to fail result in the retest. Gender, weight at birth, gestational age and presence of risk factors for hearing loss were not related to pass and/or fail results in the retest. The screening performed in intermediate care units increases the chance of continued fail result in the Transient Otoacoustic Evoked Emissions test.
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Fundação de Apoio à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Among the harmful health agents, it is given to the noise, one of the most present in urban and social environments. There are efficient measures to control the noise and the auricular Individual Protection Equipment (IPEa) is the most used. It has been observed the shortage in the comfortable and functional individual auditory protection products, related to durability, face to the efficiency right of the equipment. The main objective of this study was to recognize if there is effectiveness loss toward the used time on the Auditory Equipment, intra-auricular Individual Protection, of foam (3M), model 1110. It has been verified that the equipments suffer efficiency alteration according to the time of use, and the material consuming initiates reliable loss, mainly in audible frequencies going up to 100Hz, and from 16 days for sonorous pressure suffered started in 101dB 20Hz. For sonorous pressure suffered from 107dB to 20Hz, the reliable loss for the usage was of 8 days. The IPEas do not lose effectiveness on important attenuation by the daily use in frequencies from 1KHz until 20KHz. It has been concluded that there is effectiveness loss, according to the daily and frequent use of the IPEa studied.
Resumo:
In 2010, the Brazilian forest sector is represented by about 30,000 companies producing US$ 21 billion annually and account for approximately 5% of the gross domestic product (GDP) in the country. The sanding process is highly demanded in various stages of industrialization of the wood, when there is a need for a better quality surface finishing. The objective of this work was to analyze the influence of cutting speed and sandpaper granulometry on both the surface finishing of pieces of Eucalyptus grandis processed through tubular sanding and on the sanding efforts (force and power of sanding). Four cutting speeds were used (19.5, 22.7, 26 and 28.1 m/s), one advance speed (16 m/min) and three sets of sandpaper (80-100, 80-120 and 100-120) being one for chipping and another for finishing, respectively. A central data acquisition system was set up to capture the variables (cutting power, acoustic emission and vibration) in real time. The cutting force was obtained indirectly, through a frequency inverter. The roughness of the parts was measured by a roughness meter before and after sanding. The highest cutting speed used (28.1 m/s) consumed more power and generated more acoustic emission among the four speeds tested. Regarding the vibration, the lower cutting speed (19.5 m/ s) generated the highest vibration in the sander machine. It is concluded that the range of 100-120 sandpapers resulted in values of average roughness (Ra) lower than the other sets of sandpaper used, as it resulted in better surface finishing.
Resumo:
Baseado em um controlador digital de sinais, o sistema de monitoramento e detecção da queima em tempo real proposto neste estudo realiza a aquisição das sinais RMS de emissão acústica e da potência ativa do motor de acionamento do rebolo. Essas ações são necessárias para realizar o cálculo de estatísticas que foram utilizadas em trabalhos científicos e mostraram-se eficientes na detecção da queima em processos de retiticação. Dessa forma, é possível atuar sobre a retificadora, interrompendo seu funcionamento ou realizando correções nas variáveis do processo.
Resumo:
The teaching of acoustics has been characterized by a banking model that little contributes to the ideal training of citizens capable of understanding and acting to improve their environment soundscapes. Equally distant from the world of sound and musical culture, audio technology and acoustic environment, it is disconnected from the ever-increasing effort to raise awareness on hearing and sound education, as defended by the Canadian educator Prof. Raymond Murray Schafer. In order to provide elements for reflection on how Mathematics can be itself a language to compete in a sound education, we developed, in a dialogical and problematizing method applied to the technological and cultural world, one further research and teaching with Math students of UNEMAT in Barra do Bugres. This study pointed to the feasibility of educating consciences capable of of improving their acoustic environment, modifying the landscapes where we live, under our responsibility.
Resumo:
Os dados para este estudo foram obtidos mediante a implantação de um sistema de monitoramento por emissão acústica em uma retificadora plana tangencil. A dressagem foi realizada em rebolos convencionais e os resultados foram analisados tomando por base a relação com o desgaste volumétrico sofrido pelo diamante do dressador. As análises foram realizadas nos diamantes naturais dos tipos Brasil Extra e Mato Grosso e no sintético do tipo CVD. Os dados da emissão acústica de cada dressador foram divididos em faixas de frequência para filtrar possíveis interferências. Utilizando a faixa mais apropriada, foi possível elaborar uma curva característica para cada dressador e relacionar o desgaste do diamante com o sinal RMS da emissão acústica na faixa de frequência analisada.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)