997 resultados para Yag-Laser
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
In this study we compared the microleakage of conventional glass ionomer cement (GIC) restorations following the use of different methods of root caries removal. In vitro root caries were induced in 75 human root dentin samples that were divided in five groups of 15 each according to the method used for caries removal: in group 1 spherical carbide burs at low speed were used, in group 2 a hand-held excavator was used, and in groups 3 to 5 an Er,Cr:YSGG laser was used at 2.25 W, 40.18 J/cm(2) (group 3), 2.50 W, 44.64 J/cm(2) (group 4) and 2.75 W, 49.11 J/cm(2) (group 5). The air/water cooling during irradiation was set to 55%/65% respectively. All cavities were filled with GIC. Five samples from each group were evaluated by scanning electron microscopy (SEM) and the other ten samples were thermocycled and submitted to a microleakage test. The data obtained were compared by ANOVA followed by Fisher's test (pa parts per thousand currency sign0.05). Group 4 showed the lowest microleakage index (56.65 6.30; p < 0.05). There were no significant differences among the other groups. On SEM images samples of groups 1 and 2 showed a more regular interface than the irradiated samples. Demineralized dentin below the restoration was observed, that was probably affected dentin. Group 4 showed the lowest microleakage values compared to the other experimental groups, so under the conditions of the present study the method that provided the lowest microleakage was the Er,Cr:YSGG laser with a power output of 2.5 W yielding an energy density of 44.64 J/cm(2).
Resumo:
Die Messung der 1s Hyperfeinstruktur (HFS) wasserstoffähn-licher Ionen bei hoher Kernladung Z erlaubt den Test der QED in Gegenwart starker elektrischer und magnetischer Felder durchzuführen. Aufgrund der Z^3-Abhängigkeit der magnetischen Wechselwirkung liegt die 1s-HFS bei hohem Z im optischen Spektrum und kann mit der Laserspektroskopie untersucht werden.In der vorliegenden Arbeit wurde die Grundzustands-HFS an 207Pb81+ bestimmt. Die Experimente wurden am Speicherring ESR der Gesellschaft für Schwerionenforschung mbH am Elek-tronen-gekühlten Bleistrahl durchgeführt.Ein besonderer Schwerpunkt dieser Arbeit war die Entwick-lung neuer Experimentiertechniken, die es erlauben, lang-lebigen Strahlungsübergänge im nahen infraroten Spektral-bereich mit Hilfe der Fluoreszenz-Laserspektroskopie am Speicherring zu untersuchen. Der Ionenstrahl wurde in kollinearer Geometrie mit einem Nd:YAG-Laser angeregt und die Resonanz durch Doppler-Abstimmung gemessen. Der M1-Übergang der 1s HFS an 207Pb81+ liegt bei 1019,7(2) nm. Die QED-Korrekturen sind damit auf wenige Prozent genau bestimmt. Die theoretische Berechnung der QED-Korrekturen benutzt die gemessenen bzw. den Kernmodellen entnommenen Verteilungen der Kernladung und der Kernmagnetisierung. Die Unsicherheit der Kenntnis dieser Verteilungen spielt nur eine untergeordnete Rolle für die Fehler in der gerechneten QED-Korrektur. Allerdings existieren für das magnetische Moment von 207Pb zwei widersprüchliche Literaturwerte. Die Diskussion der Ergebnisse wird im Rahmen dieses Sachver-haltes geführt.Die natürliche Lebensdauer des oberen Hyperfein-Niveaus wurde mit 49,5(6,5) ms gemessen und ist mit dem Theoriewert von 52,3(2) ms verträglich. Durch präzise Lebensdauermes-sungen können QED-Korrekturen zum g-Faktor des gebundenen Elektrons getestet werden.
Resumo:
Die Resonanzionisations-Massenspektrometrie (RIMS) ist sowohl für spektroskopische Untersuchungen seltener Isotope als auch für den Ultraspurennachweis langlebiger radioaktiver Elemente einsetzbar. Durch die mehrstufige resonante Anregung atomarer Energieniveaus mit anschließender Ionisation mit Laserlicht wird eine sehr hohe Elementselektivität und Ionisationseffizienz erreicht. Der nachfolgende massenselektive Ionennachweis liefert eine gute Isotopenselektivität zusammen mit einer effektiven Untergrundunterdrückung. Ein wichtiger Bestandteil der RIMS-Apparatur ist ein zuverlässig arbeitendes, leistungsstarkes Lasersystem für die Resonanzionisation. Im Rahmen dieser Arbeit wurde ein von einem hochrepetierenden Nd:YAG-Laser gepumptes, aus drei Titan-Saphir-Lasern bestehendes System fertig aufgebaut und in den Routinebetrieb überführt. Die Titan-Saphir-Laser liefern im Durchstimmbereich von 730 - 880 nm eine mittlere Leistung von bis zu 3 W pro Laser bei einer Linienbreite von 2 - 3 GHz. Sie lassen sich computergesteuert in ihren Wellenlängen durchstimmen. Die mittels Resonanzionisation erzeugten Ionen werden dann in einem Flugzeit-Massenspektrometer entsprechend ihrer Masse aufgetrennt und mit einem Kanalplattendetektor nachgewiesen.Als Voraussetzung für die isotopenselektive Ultraspurenanalyse von Plutonium wurden mit diesem Lasersystem die Isotopieverschiebungen eines effizienten, dreistufigen Anregungsschema für Plutonium bestimmt. Die Laserleistungen reichen zur vielfachen Sättigung der ersten beiden Anregungsschritte und zur zweifachen Sättigung des dritten Anregungsschritts aus.Außerdem wurden die Ionisationsenergien von Pu-239 und Pu-244 zur Untersuchung ihrer Isotopenabhängigkeit bestimmt. Die beiden Ionisationsenergien sind im Rahmen der erreichten Genauigkeit bei einem Meßwert von IP239-IP244 = 0,24(82) cm^-1 gleich.Die Nachweiseffizienz der RIMS-Apparatur für Plutonium wurde in Effizienzmessungen zu 10^-5 bestimmt. Durch die gute Untergrundunterdrückung ergab sich daraus eine Nachweisgrenze von 10^6 Atomen bei der Messung eines Plutoniumisotops. Die Bestimmung der Isotopenverhältnisse von Proben mit einer zertifizierten Isotopenzusammensetzung lieferte eine gute Übereinstimmung der Meßwerte mit den angegebenen Zusammensetzungen.Die RIMS-Apparatur wurde zur Bestimmung des Gehalts und der Isotopenzusammensetzung von Plutonium in Meerwasser- und Staubproben eingesetzt.Auf Grund der Isotopenzusammensetzung konnte gezeigt werden, daß das Plutonium bei den meisten Proben aus dem Fallout von oberirdischen Kernwaffentests stammte. Des weiteren wurde Plutonium in Urinproben bestimmt. Die Nachweisgrenzen lagen bei diesen Umweltproben bei 10^6 bis 10^7 Atomen Plutonium und damit um zwei Größenordnungen niedriger als die Nachweisgrenze für Pu-239 bei der alpha-Spektroskopie, der Standardmethode für den Plutoniumnachweis.
Resumo:
Diese Arbeit befasst sich mit den optischen Resonanzen metallischer Nanopartikel im Abstand weniger Nanometer von einer metallischen Grenzfläche. Die elektromagnetische Wechselwirkung dieser „Kugel-vor-Fläche“ Geometrie ruft interessante optische Phänomene hervor. Sie erzeugt eine spezielle elektromagnetische Eigenmode, auch Spaltmode genannt, die im Wesentlichen auf den Nanospalt zwi-schen Kugel und Oberfläche lokalisiert ist. In der quasistatischen Näherung hängt die Resonanzposition nur vom Material, der Umgebung, dem Film-Kugel Abstand und dem Kugelradius selbst ab. Theoretische Berechnungen sagen für diese Region unter Resonanzbedingungen eine große Verstärkung des elektro-magnetischen Feldes voraus. rnUm die optischen Eigenschaften dieser Systeme zu untersuchen, wurde ein effizienter plasmonenver-mittelnder Dunkelfeldmodus für die konfokale Rastermikroskopie durch dünne Metallfilme entwickelt, der die Verstärkung durch Oberflächenplasmonen sowohl im Anregungs- als auch Emissionsprozess ausnutzt. Dadurch sind hochwertige Dunkelfeldaufnahmen durch die Metallfilme der Kugel-vor-Fläche Systeme garantiert, und die Spektroskopie einzelner Resonatoren wird erleichtert. Die optischen Untersuchungen werden durch eine Kombination von Rasterkraft- und Rasterelektronenmikroskopie vervollständigt, so dass die Form und Größe der untersuchten Resonatoren in allen drei Dimensionen bestimmt und mit den optischen Resonanzen korreliert werden können. Die Leistungsfähigkeit des neu entwickelten Modus wird für ein Referenzsystem aus Polystyrol-Kugeln auf einem Goldfilm demonstriert. Hierbei zeigen Partikel gleicher Größe auch die erwartete identische Resonanz.rnFür ein aus Gold bestehendes Kugel-vor-Fläche System, bei dem der Spalt durch eine selbstorganisierte Monolage von 2-Aminoethanthiol erzeugt wird, werden die Resonanzen von Goldpartikeln, die durch Reduktion mit Chlorgoldsäure erzeugt wurden, mit denen von idealen Goldkugeln verglichen. Diese ent-stehen aus den herkömmlichen Goldpartikeln durch zusätzliche Bestrahlung mit einem Pikosekunden Nd:Yag Laser. Bei den unbestrahlten Partikeln mit ihrer Unzahl an verschiedenen Formen zeigen nur ein Drittel der untersuchten Resonatoren ein Verhalten, das von der Theorie vorhergesagt wird, ohne das dies mit ihrer Form oder Größe korrelieren würde. Im Fall der bestrahlten Goldkugeln tritt eine spürbare Verbesserung ein, bei dem alle Resonatoren mit den theoretischen Rechnungen übereinstimmen. Eine Änderung der Oberflächenrauheit des Films zeigt hingegen keinen Einfluß auf die Resonanzen. Obwohl durch die Kombination von Goldkugeln und sehr glatten Metallfilmen eine sehr definierte Probengeometrie geschaffen wurde, sind die experimentell bestimmten Linienbreiten der Resonanzen immer noch wesentlich größer als die berechneten. Die Streuung der Daten, selbst für diese Proben, deutet auf weitere Faktoren hin, die die Spaltmoden beeinflußen, wie z.B. die genaue Form des Spalts. rnDie mit den Nanospalten verbundenen hohen Feldverstärkungen werden untersucht, indem ein mit Farbstoff beladenes Polyphenylen-Dendrimer in den Spalt eines aus Silber bestehenden Kugel-vor-Fläche Systems gebracht wird. Das Dendrimer in der Schale besteht lediglich aus Phenyl-Phenyl Bindungen und garantiert durch die damit einhergende Starrheit des Moleküls eine überragende Formstabiliät, ohne gleichzeitig optisch aktiv zu sein. Die 16 Dithiolan Endgruppen sorgen gleichzeitig für die notwendige Affinität zum Silber. Dadurch kann der im Inneren befindliche Farbstoff mit einer Präzision von wenigen Nanometern im Spalt zwischen den Metallstrukturen platziert werden. Der gewählte Perylen Farbstoff zeichnet sich wiederum durch hohe Photostabilität und Fluoreszenz-Quantenausbeute aus. Für alle untersuchten Partikel wird ein starkes Fluoreszenzsignal gefunden, das mindestens 1000-mal stärker ist, als das des mit Farbstoff überzogenen Metallfilms. Das Profil des Fluoreszenz-Anregungsspektrums variiert zwischen den Partikeln und zeigt im Vergleich zum freien Farbstoff eine zusätzliche Emission bei höheren Frequenzen, was in der Literatur als „hot luminescence“ bezeichnet wird. Bei der Untersuchung des Streuverhaltens der Resonatoren können wieder zwei unterschiedliche Arten von Resonatoren un-terschieden werden. Es gibt zunächst die Fälle, die bis auf die beschriebene Linienverbreiterung mit einer idealen Kugel-vor-Fläche Geometrie übereinstimmen und dann andere, die davon stark abweichen. Die Veränderungen der Fluoreszenz-Anregungsspektren für den gebundenen Farbstoffs weisen auf physikalische Mechanismen hin, die bei diesen kleinen Metall/Farbstoff Abständen eine Rolle spielen und die über eine einfache wellenlängenabhängige Verstärkung hinausgehen.
Resumo:
A spatial, electro-optical autocorrelation (EOA) interferometer using the vertically polarized lobes of coherent transition radiation (CTR) has been developed as a single-shot electron bunch length monitor at an optical beam port downstream the 100 MeV preinjector LINAC of the Swiss Light Source. This EOA monitor combines the advantages of step-scan interferometers (high temporal resolution) [D. Mihalcea et al., Phys. Rev. ST Accel. Beams 9, 082801 (2006) and T. Takahashi and K. Takami, Infrared Phys. Technol. 51, 363 (2008)] and terahertz-gating technologies [U. Schmidhammer et al., Appl. Phys. B: Lasers Opt. 94, 95 (2009) and B. Steffen et al., Phys. Rev. ST Accel. Beams 12, 032802 (2009)] (fast response), providing the possibility to tune the accelerator with an online bunch length diagnostics. While a proof of principle of the spatial interferometer was achieved by step-scan measurements with far-infrared detectors, the single-shot capability of the monitor has been demonstrated by electro-optical correlation of the spatial CTR interference pattern with fairly long (500 ps) neodymium-doped yttrium aluminum garnet (Nd:YAG) laser pulses in a ZnTe crystal. In single-shot operation, variations of the bunch length between 1.5 and 4 ps due to different phase settings of the LINAC bunching cavities have been measured with subpicosecond time resolution.
Resumo:
The vibrational excitation of CO2 by a fast-moving O atom followed by infrared emission from the vibrationally excited CO2 has been shown to be an important cooling mechanism in the upper atmospheresof Venus, Earth and Mars. We are trying to determine more precisely the efficiency (rate coefficient) of the CO2-O vibrational energy transfer. For experimental ease the reverse reaction is used, i.e. collision of a vibrationally excited CO2 with atomic O, where we are able to convert to the atmospherically relevant reaction via a known equilibrium constant. The goal of this experiment was to measure the magnitudes of rate coefficients for vibrational energy states above the first excited state, a bending mode in CO2. An isotope of CO2, 13CO2, was used for experimental ease. The rate coefficients for given vibrational energy transfers in 13CO2 are not significantly different from 12CO2 at this level of precision. A slow-flowing gas mixture was flowed through a reaction cell: 13CO2 (vibrational specie of interest), O3(atomic O source), and Ar (bath gas). Transient diode laser absorption spectroscopy was used to monitor thechanging absorption of certain vibrational modes of 13CO2 after a UV pulse from a Nd:YAG laser was fired. Ozone absorbed the UV pulse in a process which vibrationally excited 13CO2 and liberated atomic O.Transient absorption signals were obtained by tuning the diode laser frequency to an appropriate ν3 transition and monitoring the population as a function of time following the Nd:YAG pulse. Transient absorption curves were obtained for various O atom concentrations to determine the rate coefficient of interest. Therotational states of the transitions used for detection were difficult to identify, though their short reequilibration timescale made the identification irrelevant for vibrational energy transfer measurements. The rate coefficient for quenching of the (1000) state was found to be (4 ± 8) x 10-12 cm3 s-1 which is the same order of magnitude as the lowest-energy bend-excited mode: (1.8 ± 0.3) x 10-12 cm3 s-1. More data is necessary before it can be certain that the numerical difference between the two is real.
Resumo:
Transient Diode Laser Absorption Spectroscopy (TDLAS) was used to perform vibrational state population studies of the CO2 product from the hyperthermal reaction between C2H4 and O(3P) at room temperature using O3 as the O-atom precursor. Photodissociation of O3 using a frequency quadrupled Q-switch Nd:YAG laser pulse at 266 nm produced O(3P) atoms at high velocities which subsequently reacted with C2H4, producing several primary and secondary products including CO2. The CO2 product was detected using high-resolution TDLAS under five unique sets of reaction conditions. The vibrational distribution of the CO2 product did not follow a Boltzmann distribution at all five sets of conditions. The experiments showed a distribution in which there was a surprisingly high population in the (1000) (symmetric stretching) state compared with the other states probed, all of which contained bend excitation. In general, the CO2 population in the (1000) state was about 15-20% more populated than the Boltzmann distribution predicts. A possible explanation for this result may lie in the mechanism of CO2 evolution from the C2H4 + O(3P) reaction.
Resumo:
Three different fissure preparation procedures were tested and compared to the non-invasive approach using a conventional unfilled sealant and a flowable composite. Eighty permanent molars were selected and divided into 4 groups of 20 teeth each. All the teeth were split into 2 halves, and the exposed fissures were photographed under a microscope (35x) before and after being prepared using the following methods: (I) Er:YAG laser (KEY Laser, KaVo) 600 mJ pulse energy, 6 Hz; (II) diamond bur; (III) Er: YAG laser (KEY Laser, KaVo) 200 mJ pulse energy, 4 Hz; (IV) Control group: Powder jet cleaner (Prophyflex, KaVo, Germany). The pre-and postimages were superimposed in order to evaluate the amount of hard tissue removed. Ten teeth in each group were then acid etched and sealed with an unfilled sealant (Delton opaque, Dentsply), while the remaining 10 teeth were acid etched, primed and bonded (Prime ; Bond NT, Dentsply) and sealed with a flowable composite (X-flow, DeTrey, Dentsply). Material penetration and microleakage were evaluated after thermocycling (5000 cycles) and staining with methylene blue 5%. ANOVA and Mann-Whitney tests were applied for statistical analysis. The laser 600 mJ and bur eliminated the greatest amount of hard tissue. The control teeth presented the least microleakage when sealed with Delton or X-flow. A correlation between material penetration and microleakage could not be statistically confirmed. Mechanical preparation prior to fissure sealing did not enhance the final performance of the sealant.
Resumo:
This in vitro study aimed to assess the speed and caries removal effectiveness of four different new and conventional dentine excavation methods. Eighty deciduous molars were assigned to four groups. Teeth were sectioned longitudinally through the lesion centre. Images of one half per tooth were captured by light microscope and confocal laser scanning microscopy (CLSM) to assess the caries extension. The halves were then reassembled and caries removed using round carbide bur (group 1), Er:YAG laser (group 2), hand excavator (group 3) and a polymer bur (group 4). The time needed for the whole excavation in each tooth was registered. After excavation, the halves were photographed by light microscope. Caries extension obtained from CLSM images were superimposed on the post-excavation images, allowing comparison between caries extension and removal. The regions where caries and preparation limits coincided, as well as the areas of over- and underpreparation, were measured. Steel bur was the fastest method, followed by the polymer bur, hand excavator and laser. Steel bur exhibited also the largest overpreparation area, followed by laser, hand excavator and polymer bur. The largest underpreparation area was found using polymer bur, followed by laser, hand excavator and steel bur. Hand excavator presented the longest coincidence line, followed by polymer and steel burs and laser. Overall, hand excavator seemed to be the most suitable method for carious dentine excavation in deciduous teeth, combining good excavation time with effective caries removal.
Resumo:
Purpose We compared the long-term results of minimally invasive endourological intervention and open surgical revision in patients with a nonmalignant ureteroileal stricture. Materials and Methods We retrospectively evaluated the records of 74 patients (85 renal units) treated for unilateral or bilateral nonmalignant ureteroileal strictures. Overall, 96 endourological and 35 open surgical procedures were performed. Balloon dilatation and Acucise® or Ho:YAG laser endoureterotomy were used as minimally invasive endourological interventions. Open surgical revision with stricture resection and open ureteroileal end-to-side-reanastomosis was the alternate therapy. Treatment success was defined as radiological normalization or improvement of upper urinary tract morphology combined with absent flank pain, infection, ureteral stents or percutaneous nephrostomies. Results Median followup was 29 months (range 2 to 177). The overall success rate was 26% (25 of 96 cases) for endourological intervention vs 91% (32 of 35) for open surgical revision (p <0.001). Subgroup analysis showed a significant difference in the success rate of minimally invasive endourological interventions vs open surgical revision for strictures greater than 1 cm (3 of 52 cases or 6% vs 19 of 22 or 86%, p <0.001). The success rate of endourological and open surgical procedures for strictures 1 cm or less was 50% (22 of 44 cases) and 100% (13 of 13), respectively. After adjusting for multiple preoperative stricture characteristics, only stricture length was strongly and inversely associated with a successful outcome (p <0.001). Conclusions Open surgical revision produces better results than minimally invasive endourological intervention for ureteroileal strictures, particularly those greater than 1 cm. The success rate of endourological intervention is acceptable only for ureteroileal strictures 1 cm or less. Therefore, ureteroileal strictures greater than 1 cm should be primarily managed by open surgical revision.
Resumo:
The aim of the study was to compare fissure sealant quality after mechanical conditioning of erbium-doped yttrium aluminium garnet (Er:YAG) laser or air abrasion prior to chemical conditioning of phosphoric acid etching or of a self-etch adhesive. Twenty-five permanent molars were initially divided into three groups: control group (n = 5), phosphoric acid etching; test group 1 (n = 10), air abrasion; and test group 2, (n = 10) Er:YAG laser. After mechanical conditioning, the test group teeth were sectioned buccolingually and the occlusal surface of one half tooth (equal to one sample) was acid etched, while a self-etch adhesive was applied on the other half. The fissure system of each sample was sealed, thermo-cycled and immersed in 5% methylene dye for 24 h. Each sample was sectioned buccolingually, and one slice was analysed microscopically. Using specialized software microleakage, unfilled margin, sealant failure and unfilled area proportions were calculated. A nonparametric ANOVA model was applied to compare the Er:YAG treatment with that of air abrasion and the self-etch adhesive with phosphoric acid (α = 0.05). Test groups were compared to the control group using Wilcoxon rank sum tests (α = 0.05). The control group displayed significantly lower microleakage but higher unfilled area proportions than the Er:YAG laser + self-etch adhesive group and displayed significantly higher unfilled margin and unfilled area proportions than the air-abrasion + self-etch adhesive group. There was no statistically significant difference in the quality of sealants applied in fissures treated with either Er:YAG laser or air abrasion prior to phosphoric acid etching, nor in the quality of sealants applied in fissures treated with either self-etch adhesive or phosphoric acid following Er:YAG or air-abrasion treatment.
Resumo:
The Stark full widths at half of the maximal line intensity (FWHM, ω) have been measured for 25 spectrallines of PbIII (15 measured for the first time) arising from the 5d106s8s, 5d106s7p, 5d106s5f and 5d106s5g electronic configurations, in a lead plasma produced by ablation with a Nd:YAG laser. The optical emission spectroscopy from a laser-induced plasma generated by a 10 640 Å radiation, with an irradiance of 2 × 1010 W cm− 2 on a lead target (99.99% purity) in an atmosphere of argon was analysed in the wavelength interval between 2000 and 7000 Å. The broadening parameters were obtained with the target placed in argon atmosphere at 6 Torr and 400 ns after each laser light pulse, which provides appropriate measurement conditions. A Boltzmann plot was used to obtain the plasma temperature (21,400 K) and published values of the Starkwidths in Pb I, Pb II and PbIII to obtain the electron number density (7 × 1016 cm− 3); with these values, the plasma composition was determined by means of the Saha equation. Local Thermodynamic Equilibrium (LTE) conditions and plasma homogeneity has been checked. Special attention was dedicated to the possible self-absorption of the different transitions. Comparison of the new results with recent available data is also presented.
Resumo:
Este estudo possui duas partes distintas: 1. in vivo (randomizado e longitudinal) que teve como objetivo avaliar protocolos de tratamento para hipersensibilidade dentinária com laser de baixa potência (com diferentes dosagens), laser de alta potência e agente dessensibilizante, por um período de 12 e 18 meses; e 2. in vitro que teve como objetivo analisar a perda de estrutura de dois dentifrícios distintos (Colgate Total 12 e Colgate Pró Alívio) e analisar a permeabilidade dentinária dos tratamentos da etapa 01, associados aos dentifrícios, após diferentes ciclos de abrasão. Na parte in vivo, as lesões cervicais não cariosas de 32 voluntários, previamente submetidos aos critérios de elegibilidade ou exclusão, foram divididas em nove grupos (n=10): G1: Gluma Desensitizer (Heraeus Kulzer), G2: Laser de baixa potência com baixa dosagem (Photon Lase, DMC) (três pontos de irradiação vestibulares e um ponto apical: 30 mW, 10 J/cm2, 9 seg por ponto com o comprimento de onda de 810nm). Foram realizadas três sessões com um intervalo de 72 horas), G3: Laser de baixa potência com alta dosagem (um ponto cervical e um ponto apical: 100 mW, 90 J/cm2, 11 seg por ponto com o comprimento de onda de 810nm. Foram realizadas três sessões com um intervalo de 72 horas), G4: Laser de baixa potência com baixa dosagem + Gluma Desensitizer, G5: Laser de baixa potência com alta dosagem + Gluma Desensitizer, G6: Laser de Nd:YAG (Power LaserTM ST6, Lares Research®), em contato com a superfície dental: 1,0W, 10 Hz e 100 mJ, ? 85 J/cm2, com o comprimento de onda de 1064nm, G7: Laser de Nd:YAG + Gluma Desensitizer, G8: Laser de Nd:YAG + Laser de baixa potência com baixa dosagem, G9: Laser de Nd:YAG + Laser de baixa potência com alta dosagem. O nível de sensibilidade de cada voluntário foi avaliado através da escala visual analógica de dor (VAS) com auxílio do ar da seringa tríplice e exploração com sonda após 12 e 18 meses do tratamento. Na parte 02, in vitro, foram utilizados terceiros molares humanos não irrompidos e recém-extraídos. Todos foram limpos e tiveram suas raízes separadas das coroas. As raízes foram seccionadas em quadrados de dentina com dimensões de 4x4x2 mm, os quais foram embutidos em resina Epoxi e devidamente polidos até uma curvatura de 0,3 ?m, analisados em perfilometria ótica. Estes foram imersos em solução de EDTA 17% por 2min para abertura dos túbulos e armazenados em uma solução de Soro Fetal Bovino diluído em salina tamponada com fosfato. Os espécimes foram divididos aleatoriamente em 12 grupos (n=10) G1: Sem tratamento de superfície, sem dentifrício; G2: Nd:YAG/sem dentifrício; G3: Gluma/sem dentifrício; G4: Nd:YAG + Gluma/sem dentifrício; G5: Sem tratamento de superfície/Colgate Total 12; G6: Nd:YAG/Colgate Total 12; G7: Gluma/Colgate Total 12; G8: Nd:YAG + Gluma/Colgate Total 12; G9: Sem tratamento de superfície/Colgate Pró Alívio; G10: Nd:YAG/Colgate Pró Alívio; G11: Gluma/Colgate Pró Alívio; G12: Nd:YAG + Gluma/Colgate Pró Alívio. Em seguida, as superfícies receberam a aplicação de fitas adesivas nas duas margens, mantendo uma área central de teste exposta de 4 x 1 mm, onde foram realizados os tratamentos de superfície e os ciclos de abrasão correspondentes a 1, 7, 30 e 90 dias de escovação (52 ciclos, 210 segundos de contato com o slurry; 361 ciclos, 1470 segundos de contato com o slurry; 1545 ciclos, 6300 segundos de contato com o slurry; 4635 ciclos, 18900 segundos de contato com o slurry, respectivamente). A cada etapa de abrasão, foi realizada análise em Perfilometria Ótica. Para as analises de permeabilidade e Microscopia Eletrônica de Varredura, foram utilizadas amostras circulares de 6 mm de diâmetro e 1 mm de espessura de dentina obtidas das coroas dentais. Estas foram divididas aleatoriamente nos mesmos grupos já descritos anteriormente, sendo que 120 espécimes foram utilizados para permeabilidade (n=10) e 36 para MEV (n=3). Ambas as análises foram realizadas após imersão no EDTA; após tratamentos para a sensibilidade; pós 1 dia, 7 dias, 30 dias e 90 dias de escovação. Após análise estatística pode-se concluir que, in vivo, todos os tratamentos foram eficazes para a redução da hipersensibilidade dentinária. Ainda que o nível da sensibilidade dos pacientes aumentou numericamente, estes não são considerados estatisticamente diferentes a partir de 12 meses. Portanto, até a avaliação de 18 meses, podemos concluir que não houve um aumento na sensibilidade dentinária desde a sua diminuição pós-tratamento. In vitro, pode-se concluir que todos os tratamentos foram capazes de diminuir a permeabilidade dentinária. O dentifrício Total 12 apresentou-se como o mais abrasivo em comparação com o dentifrício Pro Alivio, pois este último promoveu uma perda de estrutura menor, porém ambos não apresentaram aumento na permeabilidade nos tempos de escovação. As microscopias eletrônicas de varredura mostram a formação da smear layer, obliterando os túbulos para ambos os dentifricios. Como conclusão, pode-se afirmar que todos os agentes dessensibilizantes foram efetivos, mesmo apresentando estratégias de ação diferentes. Os dentifrícios são igualmente interessantes para o uso caseiro por ocasionarem oclusão tubular e a associação de tratamentos (caseiro e de consultório) parece ser uma alternativa eficaz no tratamento da hipersensibilidade dentinária.