935 resultados para X-ray crystal structures
Resumo:
The Parkes Half-Jansky Flat-Spectrum Sample contains a large number of sources with unusually red optical-to-near-infrared (NIR) continua. If this is to be interpreted as extinction by dust in the line of sight, then associated material might also give rise to absorption in the soft X-ray regime. This hypothesis is tested using broadband (0.1-2.4 keV) data from the ROSAT All-Sky Survey. Significant (>3 sigma confidence level) correlations between the optical (and NIR)-to-soft X-ray continuum slope and optical extinction are found in the data, consistent with absorption by material with metallicity and a range in the gas-to-dust ratio as observed in the local ISM. Under this simple model, the soft X-rays are absorbed at a level consistent with the range of extinctions (0 < A(V) < 6 mag) implied by the observed optical reddening. Excess X-ray absorption by warm (ionized) gas, (i.e., a warm absorber) is not required by the data.
Resumo:
Poor root development due to constraining soil conditions could be an important factor influencing health of urban trees. Therefore, there is a need for efficient techniques to analyze the spatial distribution of tree roots. An analytical procedure for describing tree rooting patterns from X-ray computed tomography (CT) data is described and illustrated. Large irregularly shaped specimens of undisturbed sandy soil were sampled from Various positions around the base of trees using field impregnation with epoxy resin, to stabilize the cohesionless soil. Cores approximately 200 mm in diameter by 500 mm in height were extracted from these specimens. These large core samples were scanned with a medical X-ray CT device, and contiguous images of soil slices (2 mm thick) were thus produced. X-ray CT images are regarded as regularly-spaced sections through the soil although they are not actual 2D sections but matrices of voxels similar to 0.5 mm x 0.5 mm x 2 mm. The images were used to generate the equivalent of horizontal root contact maps from which three-dimensional objects, assumed to be roots, were reconstructed. The resulting connected objects were used to derive indices of the spatial organization of roots, namely: root length distribution, root length density, root growth angle distribution, root spatial distribution, and branching intensity. The successive steps of the method, from sampling to generation of indices of tree root organization, are illustrated through a case study examining rooting patterns of valuable urban trees. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
OBJECTIVE: To use magnetic resonance imaging (MRI) to validate estimates of muscle and adipose tissue (AT) in lower limb sections obtained by dual-energy X-ray absorptiometry (DXA) modelling. DESIGN: MRI measurements were used as reference for validating limb muscle and AT estimates obtained by DXA models that assume fat-free soft tissue (FFST) comprised mainly muscle: model A accounted for bone hydration only; model B also applied constants for FFST in bone and skin and fat in muscle and AT; model C was as model B but allowing for variable fat in muscle and AT. SUBJECTS: Healthy men (n = 8) and women (n = 8), ages 41 - 62 y; mean (s.d.) body mass indices (BMIs) of 28.6 (5.4) kg/m(2) and 25.1 (5.4) kg/m2, respectively. MEASUREMENTS: MRI scans of the legs and whole body DXA scans were analysed for muscle and AT content of thigh (20 cm) and lower leg (10 cm) sections; 24 h creatinine excretion was measured. RESULTS: Model A overestimated thigh muscle volume (MRI mean, 2.3 l) substantially (bias 0.36 l), whereas model B underestimated it by only 2% (bias 0.045 l). Lower leg muscle (MRI mean, 0.6 l) was better predicted using model A (bias 0.04 l, 7% overestimate) than model B (bias 0.1 l, 17% underestimate). The 95% limits of agreement were high for these models (thigh,+/- 20%; lower leg,+/- 47%). Model C predictions were more discrepant than those of model B. There was generally less agreement between MRI and all DXA models for AT. Measurement variability was generally less for DXA measurements of FFST (coefficient of variation 0.7 - 1.8%) and fat (0.8 - 3.3%) than model B estimates of muscle (0.5-2.6%) and AT (3.3 - 6.8%), respectively. Despite strong relationships between them, muscle mass was overestimated by creatinine excretion with highly variable predictability. CONCLUSION: This study has shown the value of DXA models for assessment of muscle and AT in leg sections, but suggests the need to re-evaluate some of the assumptions upon which they are based.
Resumo:
The purpose of the present investigation was to gain an understanding of the nature of the carbon contamination on the surface of standard steel transmission electron spectroscopy (TEM) specimens, the effect of exposure of a clean specimen to normal laboratory air, and the efficacy of plasma-cleaning treatments. This knowledge is a necessary prerequisite to the development of appropriate specimen preparation and/or specimen cleaning methods. X-ray photoelectron spectroscopy in combination with argon ion beam profiling was used to characterize the specimen surfaces of X65 steel and 316 stainless steel. The only clean carbon-free surface obtained was that during argon etching of the sample in the surface analysis chamber. Any exposure of a previously cleaned sample to laboratory air resulted in a rapid carbon (hydrocarbon) contamination of the sample surface and the development of surface oxidation, Plasma cleaning with subsequent exposure of the specimen to the laboratory air also resulted in a carbon-contaminated surface. This suggests that procedures of preparation of TEM specimens of steels outside an ultrahigh vacuum chamber are unlikely to result in the lowering of contamination rates on specimens to levels where measurements for carbon in the grain boundaries are possible. What is needed is a cleaning system as an integral part of the specimen insertion system into the field-emission scanning transmission electron microscope. This cleaning could be carried out by argon ion etching. Copyright (C) 2000 John Wiley & Sons, Ltd.
Resumo:
Importin-alpha is the nuclear import receptor that recognizes cargo proteins which contain classical monopartite and bipartite nuclear localization sequences (NLSs), and facilitates their transport into the nucleus. To determine the structural basis of the recognition of the two classes of NLSs by mammalian importin-alpha, we co-crystallized an N-terminally truncated mouse receptor protein with peptides corresponding to the monopartite NLS from the simian virus 40 (SV40) large T-antigen, and the bipartite NLS from nucleoplasmin. We show that the monopartite SV40 large T-antigen NLS binds to two binding sites on the receptor, similar to what was observed in yeast importin-alpha. The nucleoplasmin NLS-importin-alpha complex shows, for the first time, the mode of binding of bipartite NLSs to the receptor. The two basic clusters in the NLS occupy the two binding sites used by the monopartite NLS, while the sequence linking the two basic clusters is poorly ordered, consistent with its tolerance to mutations. The structures explain the structural basis for binding of diverse NLSs to the sole receptor protein. (C) 2000 Academic Press.
Resumo:
The reaction of the bis(propane-1,3-diamine)copper(II) ion with paraformaldehyde and nitroethane in dry methanol under basic conditions produces a macrocyclic product, (cis-3,11-dimethyl-3,11-dinitro-1,5,9,13-tetraazacyclohexadecane)copper(II) perchlorate, in low yield, compared with the good yield obtained in the parallel chemistry possible even under aqueous conditions using palladium(II) as a template. The palladium complex was reduced with zinc amalgam in dilute aqueous acid to yield the metal-free 16-membered macrocyclic hexaamine, in this case re-complexed and characterised by an X-ray crystal structure as the (cis-3,11-dimethyl-1,5,9,13-tetraazacyclohexadecane-3,11-diamine)copper(II) perchlorate. The copper ion is found in a tetragonally elongated and trigonally-distorted octahedral environment, with all six of the ligand nitrogens coordinated, the two primary amine pendant groups occupying cis sites. (C) 2000 Elsevier Science S.A. All rights reserved.
Resumo:
Plant performance is, at least partly, linked to the location of roots with respect to soil structure features and the micro-environment surrounding roots. Measurements of root distributions from intact samples, using optical microscopy and field tracings have been partially successful but are imprecise and labour-intensive. Theoretically, X-ray computed micro-tomography represents an ideal solution for non-invasive imaging of plant roots and soil structure. However, before it becomes fast enough and affordable or easily accessible, there is still a need for a diagnostic tool to investigate root/soil interplay. Here, a method for detection of undisturbed plant roots and their immediate physical environment is presented. X-ray absorption and phase contrast imaging are combined to produce projection images of soil sections from which root distributions and soil structure can be analyzed. The clarity of roots on the X-ray film is sufficient to allow manual tracing on an acetate sheet fixed over the film. In its current version, the method suffers limitations mainly related to (i) the degree of subjectivity associated with manual tracing and (ii) the difficulty of separating live and dead roots. The method represents a simple and relatively inexpensive way to detect and quantify roots from intact samples and has scope for further improvements. In this paper, the main steps of the method, sampling, image acquisition and image processing are documented. The potential use of the method in an agronomic perspective is illustrated using surface and sub-surface soil samples from a controlled wheat trial. Quantitative characterization of root attributes, e.g. radius, length density, branching intensity and the complex interplay between roots and soil structure, is presented and discussed.
Resumo:
EXAFS spectra of [(HC(Ph2PO)(3))(2)Cu](ClO4)(2). 2H(2)O have been measured at room temperature. These show that the CuO6 unit is tetragonally elongated, rather than having the compressed tetragonal geometry previously inferred from the X-ray crystal structure determination. [GRAPHICS]
Resumo:
Direct and simultaneous observation of root growth and plant water uptake is difficult because soils are opaque. X-ray imaging techniques such as projection radiography or Computer Tomography (CT) offer a partial alternative to such limitations. Nevertheless, there is a trade-off between resolution, large field-of-view and 3-dimensionality: With the current state of the technology, it is possible to have any two. In this study, we used X-ray transmission through thin-slab systems to monitor transient saturation fields that develop around roots as plants grow. Although restricted to 2-dimensions, this approach offers a large field-of-view together with high spatial and dynamic resolutions. To illustrate the potential of this technology, we grew peas in 1 cm thick containers filled with soil and imaged them at regular intervals. The dynamics of both the root growth and the water content field that developed around the roots could be conveniently monitored. Compared to other techniques such as X-ray CT, our system is relatively inexpensive and easy to implement. It can potentially be applied to study many agronomic problems, such as issues related to the impact of soil constraints (physical, chemical or biological) on root development.
Resumo:
A tandem ionization chamber was developed for quality control programs of X-ray equipment used in conventional radiography and mammography. A methodology for the use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities was established. The application at a medical X-ray imaging facility of this established methodology is presented. The use of the tandem chamber in the constancy check of diagnostic X-ray beam qualities is a useful method to control the performance of the X-ray equipment. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
The use of X-ray imaging to assess variability in ceramic fabrication is common in archaeological studies aimed at examining ancient pottery technologies. In this paper, a method based on the measurement of individual pores orientation is presented. This method is successfully applied to ceramic specimens of known origin whose structure signified different deformation histories.
Resumo:
The structure of the Tus-Ter DNA replication fork arrest complex of Escherichia coli reveals a novel architecture for the bound Tus protein and a new type of DNA-binding motif, The structure of the complex may explain how Tus can block movement of a replication fork approaching from one direction and not the other.
Resumo:
Introduction: This study evaluated the interobserver reliability of plain radiograpy versus computed tomography (CT) for the Universal and AO classification systems for distal radius fractures. Patients and methods: Five observers classified 21 sets of distal radius fractures using plain radiographs and CT independently. Kappa statistics were used to establish a relative level of agreement between observers for both readings. Results: Interobserver agreement was rated as moderate for the Universal classification and poor for the AO classification. Reducing the AO system to 9 categories and to its three main types reliability was raised to a ""moderate"" level. No difference was found for interobserver reliability between the Universal classification using plain radiographs and the Universal classification using computed tomography. Interobserver reliability of the AO classification system using plain radiographs was significantly higher than the interobserver reliability of the AO classification system using only computed tomography. Conclusion: From these data, we conclude that classification of distal radius fractures using CT scanning without plain radiographs is not beneficial.
Resumo:
The prevention and treatment of diseases related to changes in body composition require accurate methods for the measurement of body composition. However, few studies have dealt specifically with the assessment of body composition of undernourished older subjects by different methodologies. To assess the body composition of undernourished older subjects by two different methods, dual energy x-ray absorptiometry (DXA) and bioelectric impedance (BIA), and to compare results with those of an eutrophic group. The study model was cross-sectional; the study was performed at the University Hospital of the School of Medicine of Ribeiro Preto, University of So Paulo, Brazil. Forty-one male volunteers aged 62 to 91 years. The groups were selected on the basis of anamnesis, physical examination and nutritional assessment according to the Mini Nutritional Assessment (MNA) score. Body composition was assessed by DXA and BIA. Body weight, arm and calf circumference, body mass index (BMI), fat free mass (FFM) and fat mass (FM) were significantly lower in the undernourished group as compared to the eutrophic group. There were no significant differences between FFM and FM mean values determined by DXA and BIA in both groups, but the agreement between methods in the undernourished group was less strong. Our results suggest caution when BIA is to be applied in studies including undernourished older subjects. This study does not support BIA as an accurate method for the individual assessment of body composition.
Resumo:
Introduction: Human immunodeficiency virus (HIV)associated lipodystrophy syndrome (LS) includes body composition and metabolic alterations. Lack of validated criteria and tools make difficult to evaluate body composition in this group. Objective: The aim of the study was to compare different methods to evaluate body composition between Brazilians HIV subjects with (HIV+LIPO+) or without LS (HIV+LIPO-) and healthy subjects (Control). Methods: in a cross-sectional analyses, body composition was measured by bioelectrical impedance analysis (BIA), skinfold thickness (SF) and dual-energy x-ray absorptiometry (DXA) in 10 subjects from HIV+LIPO+ group; 22 subjects from HIV+LIPO- group and 12 from Control group. Results: There were no differences in age and body mass index (BMI) between groups. The fat mass (FM) (%) estimated by SF did not correlate with DXA in HIV+LIPO+ group (r = 0,46/p >0,05) and had fair agreement in both HIV groups (HIV+LIPO+ =0,35/ HIV+ LIPO- = 0,40). BIA had significant correlation in all groups (p < 0,05) and strong agreement, meanly in HIV groups, for FM (HIV+LIPO+ = 0,79/ HIV+LIPO- = 0,85/Control = 0,60) and for fat free mass (FFM) (HIV+LIPO+ = 0,93/ HIV+LIPO- = 0,92 / Control = 0,73). Discussion: Total fat mass can be measured by BIA with good precision, but not by SF in HIV-infected patients with LS. Segmental BIA, triciptal SF, circumferences of arms, waist and legs maybe alternatives that need more studies.