847 resultados para Weathering of buildings
Resumo:
Clay mineral relative abundances in approximately 450 samples from cores recovered during ODP Leg 117 in the Arabian Sea have been used to examine the paleoclimatic, paleoenvironmental, and tectonic histories of the Indus Fan, Owen Ridge, Oman margin, and adjacent continental source regions. Geographic variations in the relative abundances of minerals and correlations with depositional processes support previous interpretations that smectite has been supplied from weathering of the Deccan Traps; illite and chlorite have been supplied either from the Himalayas via marine transport or from the Iran-Makran region by winds; and palygorskite has been supplied from the Arabian peninsula and Somalia by winds. Pleistocene sediments of the Indus Fan record two modes of deposition: turbidites supplied from the Indus drainage and dominated by illite and chlorite, and pelagic carbonates containing smectites and wind-transported palygorskite. Local and regional causes for shifts between these depositional processes cannot be demonstrated conclusively with the data available, but sea-level fluctuations probably exerted a significant control on the rate of turbidite influx. Lower Miocene sediments on the Owen Ridge are also turbidites supplied by the Indus drainage; in the middle Miocene, a shift to pelagic carbonates records the uplift of the Owen Ridge, and is accompanied by the increased relative importance of wind-transported palygorskite. Associations of palygorskite and biosiliceous components in middle to upper Miocene sediments are interpreted to record vigorous monsoonal circulation and accompanying upwelling-produced biological productivity. Mineralogic and geochemical data indicate that light/dark color alternations in upper Miocene sediments on the Owen Ridge record climatic fluctuations, but the climatic significance of similar alternations in Pliocene-Pleistocene sediments is unclear. Palygorskite is the dominant clay on the Oman margin, reflecting proximity to its source areas. On the Oman margin, clay mineral relative abundances are most variable at structurally complex sites, indicating that local depositional settings have been influenced by their tectonic histories since the Miocene.
Resumo:
Natural light and its provision within asylum and other buildings is a neglected aspect of the historical archaeology of institutions. An Edwardian asylum in the north of Ireland is analysed for the management of natural light through the siting of buildings, window design and placement of interior glazing. A close reading of selected contemporary literature relating to natural light is employed to assess the significance of light provision within institutions of this period and contemporary discourses are in turn illuminated by the material practices recorded in the case study.
Resumo:
Harnessing solar energy to provide for the thermal needs of buildings is one of the most promising solutions to the global energy issue. Exploiting the additional surface area provided by the building’s façade can significantly increase the solar energy output. Developing a range of integrated and adaptable products that do not significantly affect the building’s aesthetics is vital to enabling the building integrated solar thermal market to expand and prosper. This work reviews and evaluates solar thermal facades in terms of the standard collector type, which they are based on, and their component make-up. Daily efficiency models are presented, based on a combination of the Hottel Whillier Bliss model and finite element simulation. Novel and market available solar thermal systems are also reviewed and evaluated using standard evaluation methods, based on experimentally determined parameters ISO 9806. Solar thermal collectors integrated directly into the facade benefit from the additional wall insulation at the back; displaying higher efficiencies then an identical collector offset from the facade. Unglazed solar thermal facades with high capacitance absorbers (e.g. concrete) experience a shift in peak maximum energy yield and display a lower sensitivity to ambient conditions than the traditional metallic based unglazed collectors. Glazed solar thermal facades, used for high temperature applications (domestic hot water), result in overheating of the building’s interior which can be reduced significantly through the inclusion of high quality wall insulation. For low temperature applications (preheating systems), the cheaper unglazed systems offer the most economic solution. The inclusion of brighter colour for the glazing and darker colour for the absorber shows the lowest efficiency reductions (<4%). Novel solar thermal façade solutions include solar collectors integrated into balcony rails, shading devices, louvers, windows or gutters.
Resumo:
The renewable energy sources (RES) will play a vital role in the future power needs in view of the increasing demand of electrical energy and depletion of fossil fuel with its environmental impact. The main constraints of renewable energy (RE) generation are high capital investment, fluctuation in generation and requirement of vast land area. Distributed RE generation on roof top of buildings will overcome these issues to some extent. Any system will be feasible only if it is economically viable and reliable. Economic viability depends on the availability of RE and requirement of energy in specific locations. This work is directed to examine the economic viability of the system at desired location and demand.
Resumo:
Computer game technology provides us with the tools to create web-based educational materials for autonomous and collaborative learning. At Worcester, we have researched the use of this technology in various educational contexts. This paper reports one such study; the use of the commercial game engine “Unreal Tournament 2004” (UT2004) to produce materials suitable for education of Architects. We map the concepts and principles of Architectural Design onto the affordances (development tools) provided by UT2004, leading to a systematic procedure for the realization of buildings and urban environments using this game engine. A theory for the production of web-based learning materials which supports both autonomous and collaborative learning is developed. A heuristic evaluation of our materials, used with second-year students is presented. Associated web-pages provide on-line materials for delegates.
Resumo:
Steel slag, an abundant by-product of the steel-making industry, after it is aged, has a huge potential for use as an aggregate in road construction. However, the high pH of steel slag seepage (pH≥12) is a major impediment in its beneficial use. Analyses on aged steel slag samples demonstrated that the alkalinity producing capacity of aged steel slag samples strongly correlated to Ca(OH)2 dissolution and that prolonged aging periods have marginal effects on overall alkalinity. Treatment methods that included bitumen-coating, bathing in Al(III) solutions and addition of an alum-based drinking water treatment residual (WTR) were evaluated based on reduction in pH levels and leachate alkalinity. 10% (wt./wt.) alum-based drinking water treatment residual (WTR) addition to slag was determined to be the most successful mitigation method, providing 65−70% reduction in alkalinity both in batch-type and column leach tests, but final leachate pH was only 0.5−1 units lower and leachates were contaminated by dissolved Al(+III) (≥3−4 mM). Based on the interpretation of calculated saturation indices and SEM and EDX analyses, formation of calcium sulfoaluminate phases (i.e., ettringite and monosulfate) was suggested as the mechanism behind alkalinity mitigation upon WTR-modification. The residual alkalinity in WTR-amended slag leachates was able to be completely eliminated utilizing a biosolids compost with high base neutralization capacity. In column leach tests, effluent pH levels below 7 were maintained for 58−74 pore volumes worth of WTR-amended slag leachate using 0.13 kg compost (dry wt.) per 1 kg WTR-amended slag on average; also, dissolved Al(+III) was strongly retained on the compost.
Resumo:
This thesis examines the spatial and temporal variation in nitrogen dioxide (NO2) levels in Guernsey and the impacts on pre-existing asthmatics. Whilst air quality in Guernsey is generally good, the levels of NO2 exceed UK standards in several locations. The evidence indicates that people suffering from asthma have exacerbation of their symptoms if exposed to elevated levels of air pollutants including NO2, although this research has never been carried out in Guernsey before. In addition, exposure assessment of individuals is rarely carried out and research in this area is limited due to the complexity of undertaking such a study, which will include a combination of exposures in the home, the workplace and ambient exposures, which vary depending on the individual daily experience. For the first time in Guernsey, this research has examined NO2 levels in correlation with asthma patient admissions to hospital, assessment of NO2 exposures in typical homes and typical workplaces in Guernsey. The data showed a temporal correlation between NO2 levels and the number of hospital admissions and the trend from 2008-2012 was upwards. Statistical analysis of the data did not show a significant linear correlation due to the small size of the data sets. Exposure assessment of individuals showed a spatial variation in exposures in Guernsey and assessment in indoor environments showed that real-time analysis of NO2 levels needs to be undertaken if indoor micro environments for NO2 are the be assessed adequately. There was temporal and spatial variation in NO2 concentrations measured using diffusion tubes, which provide a monthly mean value, and analysers measuring NO2 concentrations in real time. The research shows that building layout and design are important factors for good air flow and ventilation and the dispersion of NO2 indoors. Environmental Health Officers have statutory responsibilities for ambient air quality, hygiene of buildings and workplace environments and this role needs to be co-ordinated with healthcare professionals to improve health outcomes for asthmatics. The outcome of the thesis was the development of a risk management framework for pre-existing asthmatics at work for use by regulators of workplaces and an information leaflet to assist in improving health outcomes for asthmatics in Guernsey.
Resumo:
Nickel isotope ratios were measured in ores, fly ash, slags and FeNi samples from two metallurgical plants located in the Goiás State, Brazil (Barro Alto, Niquelândia). This allowed investigating the mass-dependent fractionation of Ni isotopes during the Ni-laterite ore smelting and refining. Feeding material exhibits a large range of δ60Ni values (from 0.02 ± 0.10 ‰ to 0.20 ± 0.05 ‰, n=7), explained by the diversity of Ni-bearing phases, and the average of δ60Nifeeding materials was found equal to 0.08 ± 0.08‰ (2SD, n=7). Both δ60Ni values of fly ash (δ60Ni = 0.07 ± 0.07‰, n=10) and final FeNi produced (0.05 ± 0.02 ‰, n=2) were not significantly different from the feeding materials ones. These values are consistent with the very high production yield of the factories. However, smelting slags present the heaviest δ60Ni values of all the smelter samples, with δ60Ni ranging from 0.11 ± 0.05 ‰ to 0.27 ± 0.05 ‰ (n=8). Soils were also collected near and far from the Niquelândia metallurgical plant, to evaluate the potential of Ni isotopes for tracing the natural vs anthropogenic Ni in soils. The Ni isotopic composition of the non-impacted topsoils developed on ultramafic rocks ranges from -0.26 ± 0.09 ‰ to -0.04 ± 0.05 ‰ (n=20). On the contrary, the Ni isotopic composition of the non-ultramafic topsoils, collected close to the plant, exhibit a large variation of δ60Ni, ranging from -0.19 ± 0.13 ‰ up to 0.10 ± 0.05 ‰ (n=4). This slight but significant enrichment in heavy isotopes highlight the potential impact of smelting activity in the surrounding area, as well as the potential of Ni isotopes for discerning anthropogenic samples (heavier δ60Ni values) from natural ones (lighter δ60Ni values). However, given the global range of published δ60Ni values (from -1.03 to 2.5 ‰) and more particularly those associated to natural weathering of ultramafic rocks (from -0.61 to 0.32‰), the use of Ni isotopes for tracing environmental contamination from smelters will remain challenging.
Resumo:
Aerial view of buildings surrounding racetrack.
Resumo:
This work characterizes levels of eighteen polycyclic aromatic hydrocarbons (PAHs) in the breathing air zone of firefighters during their regular work shift at eight Portuguese fire stations, and the firefighters' total internal dose by six urinary monohydroxyl metabolites (OH-PAHs). Total PAHs (ΣPAHs) concentrations varied widely (46.4-428ng/m(3)), mainly due to site specificity (urban/rural) and characteristics (age and layout) of buildings. Airborne PAHs with 2-3 rings were the most abundant (63.9-95.7% ΣPAHs). Similarly, urinary 1-hydroxynaphthalene and 1-hydroxyacenaphthene were the predominant metabolites (66-96% ΣOH-PAHs). Naphthalene contributed the most to carcinogenic ΣPAHs (39.4-78.1%) in majority of firehouses; benzo[a]pyrene, the marker of carcinogenic PAHs, accounted with 1.5-10%. Statistically positive significant correlations (r≥0.733, p≤0.025) were observed between ΣPAHs and urinary ΣOH-PAHs for firefighters of four fire stations suggesting that, at these sites, indoor air was their major exposure source of PAHs. Firefighter's personal exposure to PAHs at Portuguese fire stations were well below the existent occupational exposure limits. Also, the quantified concentrations of post-shift urinary 1-hydroxypyrene in all firefighters were clearly lower than the benchmark level (0.5μmol/mol) recommended by the American Conference of Governmental Industrial Hygienists.
Resumo:
This paper presents the determination of a mean solar radiation year and of a typical meteorological year for the region of Funchal in the Madeira Island, Portugal. The data set includes hourly mean and extreme values for air temperature, relative humidity and wind speed and hourly mean values for solar global and diffuse radiation for the period 2004-2014, with maximum data coverage of 99.7%. The determination of the mean solar radiation year consisted, in a first step, in the average of all values for each pair hour/day and, in a second step, in the application of a five days centred moving average of hourly values. The determination of the typical meteorological year was based on Finkelstein-Schafer statistics, which allows to obtain a complete year of real measurements through the selection and combination of typical months, preserving the long term averages while still allowing the analysis of short term events. The typical meteorological year validation was carried out through the comparison of the monthly averages for the typical year with the long term monthly averages. The values obtained were very close, so that the typical meteorological year can accurately represent the long term data series. The typical meteorological year can be used in the simulation of renewable energy systems, namely solar energy systems, and for predicting the energy performance of buildings.
Resumo:
This thesis explores how architectures sense of place is rooted in the natural environment. The built environment has been constructed to protect and sustain human culture from the weathering of nature. Separating experience from the natural environment removes a sense of place and belonging in the natural and reinforces architectural dominance. This separation distinguishes the natural world as an article of spectacle and gives the human experience an unnatural voyeurship to natural changes. By examining the fusion of architectural and natural edges this thesis analyzes how the human experience can reconnect with a naturalistic sense of place through architecture, blending the finite edge where architecture maintains nature, and adapting buildings to the cycles of the environment. Removing dominance of man-made spaces and replacing them with the cohabitation of the edge between built and natural forms.
Resumo:
Shows outlines, location, and construction types of buildings.
Resumo:
Energy Conservation Measure (ECM) project selection is made difficult given real-world constraints, limited resources to implement savings retrofits, various suppliers in the market and project financing alternatives. Many of these energy efficient retrofit projects should be viewed as a series of investments with annual returns for these traditionally risk-averse agencies. Given a list of ECMs available, federal, state and local agencies must determine how to implement projects at lowest costs. The most common methods of implementation planning are suboptimal relative to cost. Federal, state and local agencies can obtain greater returns on their energy conservation investment over traditional methods, regardless of the implementing organization. This dissertation outlines several approaches to improve the traditional energy conservations models. Any public buildings in regions with similar energy conservation goals in the United States or internationally can also benefit greatly from this research. Additionally, many private owners of buildings are under mandates to conserve energy e.g., Local Law 85 of the New York City Energy Conservation Code requires any building, public or private, to meet the most current energy code for any alteration or renovation. Thus, both public and private stakeholders can benefit from this research. The research in this dissertation advances and presents models that decision-makers can use to optimize the selection of ECM projects with respect to the total cost of implementation. A practical application of a two-level mathematical program with equilibrium constraints (MPEC) improves the current best practice for agencies concerned with making the most cost-effective selection leveraging energy services companies or utilities. The two-level model maximizes savings to the agency and profit to the energy services companies (Chapter 2). An additional model presented leverages a single congressional appropriation to implement ECM projects (Chapter 3). Returns from implemented ECM projects are used to fund additional ECM projects. In these cases, fluctuations in energy costs and uncertainty in the estimated savings severely influence ECM project selection and the amount of the appropriation requested. A risk aversion method proposed imposes a minimum on the number of “of projects completed in each stage. A comparative method using Conditional Value at Risk is analyzed. Time consistency was addressed in this chapter. This work demonstrates how a risk-based, stochastic, multi-stage model with binary decision variables at each stage provides a much more accurate estimate for planning than the agency’s traditional approach and deterministic models. Finally, in Chapter 4, a rolling-horizon model allows for subadditivity and superadditivity of the energy savings to simulate interactive effects between ECM projects. The approach makes use of inequalities (McCormick, 1976) to re-express constraints that involve the product of binary variables with an exact linearization (related to the convex hull of those constraints). This model additionally shows the benefits of learning between stages while remaining consistent with the single congressional appropriations framework.
Resumo:
The damaging of buildings and monuments by biological contamination is a cause of serious concern. Biocides based on chemical toxic compounds have been used to mitigate this problem. However, in the past decade many of the most effective biocides have been banned due to their environmental and health hazards. Therefore, proper remediation actions for microbiologically contaminated historic materials based on environmentally safe solution is of vital importance. Bacillus species are emerging as a promising alternative for built heritage treatment. They produce a great diversity of secondary metabolites with biological activity, well known to possess antagonistic activities against many fungal pathogens. In order to evaluate the antifungal activity of the novel biocides produced in our laboratory by cultures of selected bacterial strains, liquid interaction assays using four biodeteriogenic fungi were achieved, revealing a nearly 100% of inhibitory capacity to fungal proliferation. To confirm their effective safe toxicological properties, in vivo tests using two different biological models were performed. The lyophilized supernatant of the Bacillus culture broth showed no lethality against brine shrimp and also no toxicological effects in Swiss mice through administration of acute dose of 5000 mg/kg by oral gavage. In fact, the bioactive compounds were no lethal at the tested dose unlike Preventol® (commercial biocide) that induced acute toxicity with 10 times minor concentration dose administrated in the same conditions. Therefore, the new bioactive compounds that suppress growth of biodeteriogenic fungi on historical artworks, presenting at the same time no toxicity against other living organisms, constituting an efficient and green safe solution for biodegradation/biodeterioration treatment of Cultural Heritage.