883 resultados para WARFARIN DOSE REQUIREMENTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A basic prerequisite for in vivo X-ray imaging of the lung is the exact determination of radiation dose. Achieving resolutions of the order of micrometres may become particularly challenging owing to increased dose, which in the worst case can be lethal for the imaged animal model. A framework for linking image quality to radiation dose in order to optimize experimental parameters with respect to dose reduction is presented. The approach may find application for current and future in vivo studies to facilitate proper experiment planning and radiation risk assessment on the one hand and exploit imaging capabilities on the other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Association of mood stabiliser and antipsychotic medication is indicated in psychotic mania, but specific guidelines for the treatment of a first episode of psychotic mania are needed. Aims: To compare safety and efficacy profiles of chlorpromazine and olanzapine augmentation of lithium treatment in a first episode of psychotic mania. Methods: A total of 83 patients were randomised to either lithium + chlorpromazine or lithium + olanzapine in an 8-week trial. Data was collected on side effects, vital signs and weight modifications, as well as on clinical variables. Results: There were no differences in the safety profiles of both medications, but patients in the olanzapine group were significantly more likely to have reached mania remission criteria after 8 weeks. Mixed effects models repeated measures analysis of variance showed that patients in the olanzapine group reached mania remission significantly earlier than those in the chlorpromazine group. Conclusions: These results suggest that while olanzapine and chlorpromazine have a similar safety profile in a cohort of patients with first episode of psychotic mania, the former has a greater efficacy on manic symptoms. On this basis, it may be a better choice for such conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Clarithromycin is compared with clindamycin for single-dose prophylaxis of streptococcal endocarditis in rats. Human-like kinetics of the two antibiotics prevented endocarditis in animals challenged with both small and large amounts of bacterial inocula. Clarithromycin was marginally superior to clindamycin against small amounts of inocula. Clarithromycin may be considered for endocarditis chemoprophylaxis in human.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report on Compliance with IPERS Requirements for Certain Members from the LuVerne Community School District

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of CT applications might become a public health problem if no effort is made on the justification and the optimisation of the examinations. This paper presents some hints to assure that the risk-benefit compromise remains in favour of the patient, especially when one deals with the examinations of young patients. In this context a particular attention has to be made on the justification of the examination. When performing the acquisition one needs to optimise the extension of the volume investigated together with the number of acquisition sequences used. Finally, the use of automatic exposure systems, now available on all the units, and the use of the Diagnostic Reference Levels (DRL) should allow help radiologists to control the exposure of their patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In vitro studies suggested that sub-millisecond pulses of radiation elicit less genomic instability than continuous, protracted irradiation at the same total dose. To determine the potential of ultrahigh dose-rate irradiation in radiotherapy, we investigated lung fibrogenesis in C57BL/6J mice exposed either to short pulses (≤ 500 ms) of radiation delivered at ultrahigh dose rate (≥ 40 Gy/s, FLASH) or to conventional dose-rate irradiation (≤ 0.03 Gy/s, CONV) in single doses. The growth of human HBCx-12A and HEp-2 tumor xenografts in nude mice and syngeneic TC-1 Luc(+) orthotopic lung tumors in C57BL/6J mice was monitored under similar radiation conditions. CONV (15 Gy) triggered lung fibrosis associated with activation of the TGF-β (transforming growth factor-β) cascade, whereas no complications developed after doses of FLASH below 20 Gy for more than 36 weeks after irradiation. FLASH irradiation also spared normal smooth muscle and epithelial cells from acute radiation-induced apoptosis, which could be reinduced by administration of systemic TNF-α (tumor necrosis factor-α) before irradiation. In contrast, FLASH was as efficient as CONV in the repression of tumor growth. Together, these results suggest that FLASH radiotherapy might allow complete eradication of lung tumors and reduce the occurrence and severity of early and late complications affecting normal tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Audit report on applying agreed-upon procedures for the City of Linden’s compliance with road use tax requirements for the period July 1, 1999 through June 30, 2004

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Vitamin D plays a major role in bone metabolism and neuromuscular function. Supplementation with vitamin D is effective to reduce the risk of fall and of fracture. However adherence to oral daily vitamin D supplementation is low. Screening and correcting vitamin D insufficiency in a general rheumatologic population could improve both morbidity and quality of life in these patients with chronic painful disorders and at high risk of osteoporosis. After determining the prevalence of vitamin D deficiency in this population, we evaluated if supplementation with a single high dose of oral 25-OH vitamin D3 was sufficient to correct this abnormality. Methods: During one month (November 2009), levels of 25-OH vitamin D were systematically determined in our rheumatology outpatient clinic and classified into three groups: vitamin D deficiency (<10 μg/l), vitamin D insufficiency (10 to 30 μg/l) or normal vitamin D (>30 μg/l). Patients with insufficiency or deficiency received respectively a single high dose of 300000 IU or 600000 IU oral vitamin D3. In addition, all patients with osteoporosis were prescribed daily supplement of calcium (1 g) and vitamin D (800 IU). 25-OH vitamin D levels were reevaluated after 3 months. Results: Vitamin D levels were initially determined in 292 patients (mean age 53, 211 women, 87% Caucasian). 77% had inflammatory rheumatologic disease (IRD), 20% osteoporosis (OP) and 12% degenerative disease (DD). Vitamin D deficiency was present in 20 (6.8%), while 225 (77.1%) had insufficiency. Of the 245 patients with levels <30 μg/l, a new determination of vitamin D level was available in 173 (71%) at 3 months. Conclusion: Vitamin D insufficiency is highly prevalent in our rheumatologic population (84%), and is not adequately corrected by a single high dose of oral vitamin D3 in more than half of the patients with IRD and DD. In patients with OP, despite association of a single high dose with daily oral vitamin D supplementation, 40% of patients are still deficient when reevaluated at 3 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Starting in February 1994, 20 patients (pt) with a median age of 50 years(range 41-63) from 7 European centers have been included. Completedata were obtained in 16 patients so far. CPC were mobilized with chemo(Epirubicine 75 mg/m2 /d, 01 + 02) followed by G-CSF 5 p.gfkg/d for14 days. HD chemo consisted in 3 sequential courses of ICE regimen(UOs. 10 g/m2 , Carbo. 1200 mg/m2 and Etop. 1200 mg/m2 ) underCPC protection and G-CSF 5 p.g/kg/d. Out of the 16 pt, 12 completedfull program (3 cycles). One pt died of septic shock before receivingany ICE course. One pt died during the first ICE of renal insufficiency.Two pt had only 2 courses because of toxicity. Among the 16 pt, responserate (RR) was: 7 CR, 6 PR, 1 PO; 3 pt are not evaluable dueto early withdrawal (overall RR: 13/16 = 81 %). Thirty-nine cycles ofHD chemo were given with a median hematological recovery of 9 days(range 7-12) until neutro. counts> 1.0 x 109 /1 and 9 days (range 717)until thrombo. > 20 x 109 /1. No cumulative, hematological toxicitywas seen. Accrual of patients is still ongoing and updated results will bepresented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimal location of services is one of the most important factors that affects service quality in terms of consumer access. On theother hand, services in general need to have a minimum catchment area so as to be efficient. In this paper a model is presented that locates the maximum number of services that can coexist in a given region without having losses, taking into account that they need a minimum catchment area to exist. The objective is to minimize average distance to the population. The formulation presented belongs to the class of discrete P--median--like models. A tabu heuristic method is presented to solve the problem. Finally, the model is applied to the location of pharmacies in a rural region of Spain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.