808 resultados para Types of optical fibres
Resumo:
Oxygen-deficient TiO2 films with enhanced visible and near-infrared optical absorption have been deposited by reactive sputtering using a planar diode radio frequency magnetron configuration. It is observed that the increase in the absorption coefficient is more effective when the O-2 gas supply is periodically interrupted rather than by a decrease of the partial O-2 gas pressure in the deposition plasma. The optical absorption coefficient at 1.5 eV increases from about 1 x 10(2) cm(-1) to more than 4 x 10(3) cm(-1) as a result of the gas flow discontinuity. A red-shift of similar to 0.24 eV in the optical absorption edge is also observed. High resolution transmission electron microscopy with composition analysis shows that the films present a dense columnar morphology, with estimated mean column width of 40nm. Moreover, the interruptions of the O-2 gas flow do not produce detectable variations in the film composition along its growing direction. X-ray diffraction and micro-Raman experiments indicate the presence of the TiO2 anatase, rutile, and brookite phases. The anatase phase is dominant, with a slight increment of the rutile and brookite phases in films deposited under discontinued O-2 gas flow. The increase of optical absorption in the visible and near-infrared regions has been attributed to a high density of defects in the TiO2 films, which is consistent with density functional theory calculations that place oxygen-related vacancy states in the upper third of the optical bandgap. The electronic structure calculation results, along with the adopted deposition method and experimental data, have been used to propose a mechanism to explain the formation of the observed oxygen-related defects in TiO2 thin films. The observed increase in sub-bandgap absorption and the modeling of the corresponding changes in the electronic structure are potentially useful concerning the optimization of efficiency of the photocatalytic activity and the magnetic doping of TiO2 films. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4724334]
Resumo:
The work reported here involved an investigation into the grinding process, one of the last finishing processes carried out on a production line. Although several input parameters are involved in this process, attention today focuses strongly on the form and amount of cutting fluid employed, since these substances may be seriously pernicious to human health and to the environment, and involve high purchasing and maintenance costs when utilized and stored incorrectly. The type and amount of cutting fluid used directly affect some of the main output variables of the grinding process which are analyzed here, such as tangential cutting force, specific grinding energy, acoustic emission, diametrical wear, roughness, residual stress and scanning electron microscopy. To analyze the influence of these variables, an optimised fluid application methodology was developed (involving rounded 5, 4 and 3 turn diameter nozzles and high fluid application pressures) to reduce the amount of fluid used in the grinding process and improve its performance in comparison with the conventional fluid application method (of diffuser nozzles and lower fluid application pressure). To this end, two types of cutting fluid (a 5% synthetic emulsion and neat oil) and two abrasive tools (an aluminium oxide and a superabrasive CBN grinding wheel) were used. The results revealed that, in every situation, the optimised application of cutting fluid significantly improved the efficiency of the process, particularly the combined use of neat oil and CBN grinding wheel. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This note clarifies the design of proportional derivative (PD) controllers for the magnetic levitation systems of micro PM motors proposed in the above paper. It is shown that the PD controllers cannot stabilize the described levited micro motors because it is necessary to use other values of parameters for these controllers. We present necessary and sufficient conditions for the stability of the controlled systems described in the paper.
Resumo:
O objetivo da presente investigação experimental foi avaliar o perfil mecânico de três tipos de técnicas de sutura entre tendões de dimensões diferentes. Foram utilizados 21 cães sem raça definida (11machos/10 fêmeas), dos quais foram obtidos os tendões flexor comum dos dedos - t.c. (maior dimensão) e tibial cranial - t.cr. (menor dimensão), de ambos os membros pélvicos. Logo após a obtenção das peças foi realizada sutura, segundo cada tipo de técnica, porém sempre com o mesmo número de pontos. Os tendões utilizados para sutura foram sempre do lado direito e o controle do lado esquerdo (t.cr.). Após a sutura, os corpos de prova foram fixados em garras especialmente desenvolvidas e submetidos a ensaio de tração axial à velocidade de 30mm/minuto. Após o ensaio o programa da máquina forneceu os valores da carga máxima ( na ruptura) e deformação absoluta (mm) e relativa (%), além do diagrama carga-deformação. Os resultados foram submetidos a estudo estatístico pela análise de medidas repetidas no nível de 5% de significância. Não foi constatada diferença estatisticamente significativa nos parâmetros mecânicos avaliados nos três grupos de técnicas de suturas. em relação ao controle (tendão de menos diâmetro contra-lateral), observou-se que a sutura apresenta resistência máxima a tração significativamente menor que o controle e maior deformação.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this study was to evaluate by means of digital radiography the behavior of the alveolar bone crest in external hexagon implants following the use of 2 different types of abutments, one for conventional cemented prosthesis and one for modified cemented prosthesis.Methods: Ten external hexagon implants (platform 4.1) were placed in 5 patients. Initial instrumentation was carried out to obtain primary stability of the temporary prostheses under immediate loading. Each patient received both abutments for conventional and modified cemented prosthesis. Standardized digital periapical radiographies were performed at times T0 (immediately after implant placement) and T1 (4 months after implant placement). A straight line was initially established from the implant platform to the distal and mesial periimplantar marginal bone tissue (immediately in contact with the implant) and measured by digital radiography, using Sidexis version 2.3 (Sirona Dental Systems GmbH, Bensheim, Germany) software. The data were submitted to paired-samples t-test analysis.Results: There was no significant difference between the conventional and modified cemented prosthesis. In both cases, t-test results were within the null hypothesis level.Conclusion: The abutment for the modified cemented prosthesis resulted in no significant radiographic difference of alveolar bone crest height, when compared with the conventional cemented prostheses.
Resumo:
Purpose: The aims of this study were to evaluate the trends in funding, geographic origin, and study types of original articles in the dental implant literature and to investigate the relationships among these factors. Materials and Methods: Articles published in Clinical Oral Implants Research, The International Journal of Oral & Maxillofacial Implants, Clinical Implant Dentistry and Related Research, Implant Dentistry, and Journal of Oral Implantology from 2005 to 2009 were reviewed. Nonoriginal articles were excluded. For each article included, extramural funding source, geographic origin, and study type were recorded. Descriptive and analytic analyses (alpha = .05), including a logistic regression analysis, and chi-square test were used where appropriate. Results: of a total of 2,085 articles published, 1,503 met the inclusion criteria. The most common source of funding was from industry (32.4%). The proportion of studies that reported funding increased significantly over time. Europe represented the highest percentage (55.8%) of published articles. Most of the articles reported on clinical studies (49.9%), followed by animal studies (25.9%). Articles from Asia and South America and animal and in vitro studies were significantly more likely to be funded. Conclusion: Almost half of the original dental implant articles were funded. The trend toward internationalization of authorship was evident. A strong association was observed between funding and geographic origin and between funding and study type. Most studies in North America and Europe were clinical studies and supported by industry, whereas a greater proportion of studies in Asia and South America were in vitro or animal studies funded through government resources. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:69-76
Resumo:
Avaliação da Biodegradação de Diferentes Tipos de Óleo Lubrificante em Meio Aquoso pela Norma Técnica L6.350 (CETESB, 1990), utiliza-se o processo respirométrico de Bartha e Pramer para acompanhar a biodegradação de diferentes tipos de óleo lubrificante automotivo adaptado ao meio aquoso. Para realização do experimento foram preparados um inóculo base e, posteriormente, um inóculo aquoso. Quatro tratamentos foram realizados em dois experimentos consecutivos: T1 (controle); T2 (óleo semi-sintético); T3 (óleo mineral); T4 (óleo usado). Dentre os resultados, obteve-se a seguinte ordem decrescente na produção de CO2 nos respirômetros: T4 > T2 > T3 > T1. Assim, o óleo lubrificante usado surgiu com maior biodegradabilidade, seguido do semisintético e do óleo mineral. Observou-se também que o lubrificante mineral apresentou maior período de adaptação comparado ao semisintético.
Resumo:
Mongolian gerbils (Meriones unguiculatus) were grouped into two experimental groups: GEx.01 suffered orchiectomy and after 30 days received doses of testosterone cipionate (T), while GEx.02 received weekly and alternated doses of the anti-androgens cyproterone acetate and flutamide for 30 days, and the animals were then euthanized. Structural evaluation reveals a more intense reduction in epithelial height in GEx.02. Smooth muscle cells (SMC) presented a star-shaped aspect after 30 days of hormonal ablation and basal membrane was shown to be more intensely grooved in GEx.01. In both groups, after hormonal replacement, recovery in epithelial height could be noted and the SMC presented its phenotypes, but an increase in RER was seen, characterizing a modulation from its contractile to secreting phenotype. In conclusion, the prostate presented involution capacity after androgen ablation and the ability to reorganize after hormonal replacement, but events resulting from orchiectomy and subsequent T replacement were shown to be more aggressive to the prostate. (c) 2006 International Federation for Cell Biology. Published by Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The theory of optical dispersive shocks generated in the propagation of light beams through photorefractive media is developed. A full one-dimensional analytical theory based on the Whitham modulation approach is given for the simplest case of a sharp steplike initial discontinuity in a beam with one-dimensional striplike geometry. This approach is confirmed by numerical simulations, which are extended also to beams with cylindrical symmetry. The theory explains recent experiments where such dispersive shock waves have been observed.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)