510 resultados para Twist drills


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We discuss the relation between correlation functions of twist-two large spin operators and expectation values of Wilson loops along light-like trajectories. After presenting some heuristic field theoretical arguments suggesting this relation, we compute the divergent part of the correlator in the limit of large 't Hooft coupling and large spins, using a semi-classical world-sheet which asymptotically looks like a GKP rotating string. We show this diverges as expected from the expectation value of a null Wilson loop, namely, as (ln mu(-2))(2). mu being a cut-off of the theory. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOAR

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the performance of individuals not trained in methods under performing resistance exercise in the method of multiple series and the following exercises: Leg press (LP) 45, leg extension (CE), leg curl (CF), front handle (PF), rowing neutral (RN), bench press (SR) and Peck deck (PD) in 9 weeks with three training sessions / week. The study was with of 6 individuals aged 40 to 55 years were divided into two groups all were tested using the 1 RM for securing cargo to the drills being performed each test 48 h. Results: According to what was observed using this training protocol with different volume in each group for 9 weeks of training in these subjects did not differ in both groups but showed increases above two devices with other evaluated Peck deck and this is due Leg Press major muscle group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ObjectiveTo compare peri-implant tissue healing at implants installed in sites prepared with conventional drills or a sonic device.Material and methodsIn six Beagle dogs, the mandibular premolars and first molars were extracted bilaterally. After 3 months, full-thickness muco-periosteal flaps were elevated and recipient sites were prepared in both sides of the mandible. In the right side (control), the osteotomies were prepared using conventional drills, while, at the left side (test), a sonic device (Sonosurgery((R))) was used. Two implants were installed in each side of the mandible. After 8weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation.ResultsThe time consumed for the osteotomies at the test was more than double compared to the conventional control sites. No statistically significant differences were found for any of the histological variables evaluated for hard and soft tissue dimensions. Although not statistically significant, slightly higher mineralized bone-to-implant contact was found at the test (65.4%) compared to the control (58.1) sites.ConclusionsSimilar healing characteristics in osseointegration and marginal hard tissue remodeling resulted at implants installed into osteotomies prepared with conventional drills or with the sonic instrument (Sonosurgery((R))).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To compare peri-implant soft- and hard-tissue integration at implants installed juxta- or sub-crestally. Furthermore, differences in the hard and soft peri-implant tissue dimensions at sites prepared with drills or sonic instruments were to be evaluated. Three months after tooth extraction in six dogs, recipient sites were prepared in both sides of the mandible using conventional drills or a sonic device (Sonosurgery(®) ). Two implants with a 1.7-mm high-polished neck were installed, one with the rough/smooth surface interface placed at the level of the buccal bony crest (control) and the second placed 1.3 mm deeper (test). After 8 weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation. The buccal distances between the abutment/fixture junction (AF) and the most coronal level of osseointegration (B) were 1.6 ± 0.6 and 2.4 ± 0.4 mm; between AF and the top of the bony crest (C), they were 1.4 ± 0.4 and 2.2 ± 0.2 mm at the test and control sites, respectively. The top of the peri-implant mucosa (PM) was located more coronally at the test (1.2 ± 0.6 mm) compared to the control sites (0.6 ± 0.5 mm). However, when the original position of the bony crest was taken into account, a higher bone loss and a more apical position of the peri-implant mucosa resulted at the test sites. The placement of implants into a sub-crestal location resulted in a higher vertical buccal bone resorption and a more apical position of the peri-implant mucosa in relation to the level of the bony crest at implant installation. Moreover, peri-implant hard-tissue dimensions were similar at sites prepared with either drills or Sonosurgery(®) .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Apical surgeries are part of a segment of root canal treatment by which we can correct or eliminate iatrogenic deficiencies arising from conventional endodontic treatment. Currently no consensus among authors regarding to the factors linked to the surgery success as the execution of an apex resection followed by retropreparation and retrofilling. The apex resection performed 3mm from apical vertex allows the elimination of most apical ramifications, and it is a consensus part of the treatment. The preparation of cavities using ultrasonic tips has advantages over those made with drills such as better cleaning of the cavity, the possibility of lower cutting angle of the apical resection and deeper retropreparation. Another detail to consider is the type of tip, since the diamond tips in a more angulated inclination have higher cutting efficiency but causing increased formation of debris on the dentin walls. Finally, filling the cavity with an apical filling material allows proper sealing of the intracanal contents favoring apical healing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nine swines of the White Large race were used for study of the process of bony repair after osteotomy with rotating instruments of low and high-speed, with and without liquid refrigeration. The authors observed, through double blind histopathological analysis, that in every analyzed operative time, the bony repair was processed more appropriately when the osteotomies were accomplished with liquid refrigeration. In the final postoperative times, of fourteen and twenty-eight days, the best results of bony repair were observed in the osteotomy accomplished with drills of low rotation and with liquid refrigeration, while in the postoperative time of seven days, the results of the bony repair of osteotomy accomplished with drills of high rotation and with liquid refrigeration they were better. The authors consider, still, that the process of bony repair in swine display larger proximity in the histological pictures among the studied variables, when compared with other biological models. As most of the works told in the literature it refers the use of dogs, the authors consider that the present work guarantees your importance in the sense of looking for a closer model of the man.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV