978 resultados para Thickness measurement.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The assessment of the glacier thickness is one of the most widespread applications of radioglaciology, and is the basis for estimating the glacier volume. The accuracy of the measurement of ice thickness, the distribution of profiles over the glacier and the accuracy of the boundary delineation of the glacier are the most important factors determining the error in the evaluation of the glacier volume. The aim of this study is to get an accurate estimate of the error incurred in the estimate of glacier volume from GPR-retrieved ice-thickness data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laser Shock Processing (LSP) has been demonstrated as an emerging technique for the induction of RS’s fields in subsurface layers of relatively thick specimens. However, the LSP treatment of relatively thin specimens brings, as an additional consequence, the possible bending in a process of laser shock forming. This effect poses a new class of problems regarding the attainment of specified RS’s depth profiles in the mentioned type of sheets, and, what can be more critical, an overall deformation of the treated component. The analysis of the problem of LSP treatment for induction of tentatively through-thickness RS’s fields for fatigue life enhancement in relatively thin sheets in a way compatible with reduced overall workpiece deformation due to spring-back self-equilibration is envisaged in this paper. The coupled theoretical-experimental predictive approach developed by the authors has been applied to the specification of LSP treatments for achievement of RS's fields tentatively able to retard crack propagation on normalized specimens. A convergence between numerical code results and experimental results coming from direct RS's measurement is presented as a first step for the treatment of the normalized specimens under optimized conditions and verification of the crack retardation properties virtually induced.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurate and automated methods for measuring the thickness of human cerebral cortex could provide powerful tools for diagnosing and studying a variety of neurodegenerative and psychiatric disorders. Manual methods for estimating cortical thickness from neuroimaging data are labor intensive, requiring several days of effort by a trained anatomist. Furthermore, the highly folded nature of the cortex is problematic for manual techniques, frequently resulting in measurement errors in regions in which the cortical surface is not perpendicular to any of the cardinal axes. As a consequence, it has been impractical to obtain accurate thickness estimates for the entire cortex in individual subjects, or group statistics for patient or control populations. Here, we present an automated method for accurately measuring the thickness of the cerebral cortex across the entire brain and for generating cross-subject statistics in a coordinate system based on cortical anatomy. The intersubject standard deviation of the thickness measures is shown to be less than 0.5 mm, implying the ability to detect focal atrophy in small populations or even individual subjects. The reliability and accuracy of this new method are assessed by within-subject test–retest studies, as well as by comparison of cross-subject regional thickness measures with published values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods: Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (SW) and the within-subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results: The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion: Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thickness of 210 A1 pulleys of 21 male and female healthy volunteers in two different age groups (20-35 y and 50-70 y) were measured by ultrasound. In a second group, the thickness of 15 diseased A1 pulleys and 15 A1 pulleys of the corresponding other hand of 10 patients with the clinical diagnosis of trigger finger were measured by ultrasound. During open trigger finger release, a strip of A1 pulley was excised and immediately measured using an electronic caliper. The average pulley thickness of healthy volunteers was 0.43-0.47 mm, compared to 0.77-0.79 mm in patients with trigger finger. Based on the receiver operating characteristic (ROC) curve, a diagnostic cut-off value of the pulley thickness at 0.62 mm was defined in order to differ a trigger finger from a healthy finger (sensitivity and specificity of 85%). The correlation between sonographic and effective intra-operative measurements of pulley thickness was linear and very strong (Pearson coefficient 0.86-0.90). In order to distinguish between healthy and diseased A1 pulleys, 0.62 mm is a simple value to use, which can be applied regardless of age, sex, body mass index (BMI) and height in adults.