849 resultados para Thermal stresses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comentari sobre l'article publicat anteriorment pels mateixos autors: Vargas, M; Pallás, R; The seemingly paradoxical noise behaviour some active circuits. IEEE Transactions on Instrumentation and Measurement. 1994, vol. 43, núm. 5, p. 764-767

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correspondència referida a l'article de R. Giannetti, publicat ibid. vol.49 p.87-88

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The safe use of nuclear power plants (NPPs) requires a deep understanding of the functioning of physical processes and systems involved. Studies on thermal hydraulics have been carried out in various separate effects and integral test facilities at Lappeenranta University of Technology (LUT) either to ensure the functioning of safety systems of light water reactors (LWR) or to produce validation data for the computer codes used in safety analyses of NPPs. Several examples of safety studies on thermal hydraulics of the nuclear power plants are discussed. Studies are related to the physical phenomena existing in different processes in NPPs, such as rewetting of the fuel rods, emergency core cooling (ECC), natural circulation, small break loss-of-coolant accidents (SBLOCA), non-condensable gas release and transport, and passive safety systems. Studies on both VVER and advanced light water reactor (ALWR) systems are included. The set of cases include separate effects tests for understanding and modeling a single physical phenomenon, separate effects tests to study the behavior of a NPP component or a single system, and integral tests to study the behavior of the whole system. In the studies following steps can be found, not necessarily in the same study. Experimental studies as such have provided solutions to existing design problems. Experimental data have been created to validate a single model in a computer code. Validated models are used in various transient analyses of scaled facilities or NPPs. Integral test data are used to validate the computer codes as whole, to see how the implemented models work together in a code. In the final stage test results from the facilities are transferred to the NPP scale using computer codes. Some of the experiments have confirmed the expected behavior of the system or procedure to be studied; in some experiments there have been certain unexpected phenomena that have caused changes to the original design to avoid the recognized problems. This is the main motivation for experimental studies on thermal hydraulics of the NPP safety systems. Naturally the behavior of the new system designs have to be checked with experiments, but also the existing designs, if they are applied in the conditions that differ from what they were originally designed for. New procedures for existing reactors and new safety related systems have been developed for new nuclear power plant concepts. New experiments have been continuously needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to evaluate the effect of heat waves on the evolution of bud dormancy, in apple trees with contrasting chilling requirements. Twigs of 'Castel Gala' and 'Royal Gala' were collected in orchards in Papanduva, state of Santa Catarina, Brazil, and were exposed to constant (3°C) or alternating (3 and 15°C for 12/12 hours) temperature, combined with zero, one or two days a week at 25°C. Two additional treatments were evaluated: constant temperature (3°C), with a heat wave of seven days at 25°C, in the beginning or in the middle of the experimental period. Periodically, part of the twigs was transferred to 25°C for daily budburst evaluation of apical and lateral buds. Endodormancy (dormancy induced by cold) was overcome with less than 330 chilling hours (CH) of constant cold in 'Castel Gala' and less than 618 CH in 'Royal Gala'. A daily 15°C-temperature cycle did not affect the endodormancy process. Heat waves during endodormancy resulted in an increased CH to achieve bud requirements. The negative effect of high temperature depended on the lasting of this condition. Chilling was partly cancelled during dormancy when the heat wave lasted 36 continuous hours or more. Therefore, budburst prediction models need adjustments, mainly for regions with mild and irregular winters, such as those of Southern Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The key parameters associated to the thermally induced spin crossover process have been calculated for a series of Fe(II) complexes with mono-, bi-, and tridentate ligands. Combination of density functional theory calculations for the geometries and for normal vibrational modes, and highly correlated wave function methods for the energies, allows us to accurately compute the entropy variation associated to the spin transition and the zero-point corrected energy difference between the low- and high-spin states. From these values, the transition temperature, T 1/2, is estimated for different compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To study the influence of the menstrual cycle on whole body thermal balance and on thermoregulatory mechanisms, metabolic heat production (M) was measured by indirect calorimetry and total heat losses (H) were measured by direct calorimetry in nine women during the follicular (F) and the luteal (L) phases of the menstrual cycle. The subjects were studied while exposed for 90 min to neutral environmental conditions (ambient temperature 28 degrees C, relative humidity 40%) in a direct calorimeter. The values of M and H were not modified by the phase of the menstrual cycle. Furthermore, in both phases the subjects were in thermal equilibrium because M was similar to H (69.7 +/- 1.8 and 72.1 +/- 1.8 W in F and 70.4 +/- 1.9 and 71.4 +/- 1.7 W in L phases, respectively). Tympanic temperature (Tty) was 0.24 +/- 0.07 degrees C higher in the L than in the F phase (P less than 0.05), whereas mean skin temperature (Tsk) was unchanged. Calculated skin thermal conductance (Ksk) was lower in the L (17.9 +/- 0.6 W.m-2.degrees C-1) than in the F phase (20.1 +/- 1.1 W.m-2.degrees C-1; P less than 0.05). Calculated skin blood flow (Fsk) was also lower in the L (0.101 +/- 0.008 l.min-1.m-2) than in the F phase (0.131 +/- 0.015 l.min-1.m-2; P less than 0.05). Differences in Tty, Ksk, and Fsk were not correlated with changes in plasma progesterone concentration. It is concluded that, during the L phase, a decreased thermal conductance in women exposed to a neutral environment allows the maintenance of a higher internal temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityön tavoitteena on paineistimen yksityiskohtainen mallintaminen APROS- ja TRACE- termohydrauliikkaohjelmistoja käyttäen. Rakennetut paineistinmallit testattiin vertaamalla laskentatuloksia paineistimen täyttymistä, tyhjentymistä ja ruiskutusta käsittelevistä erilliskokeista saatuun mittausdataan. Tutkimuksen päätavoitteena on APROSin paineistinmallin validoiminen käyttäen vertailuaineistona PACTEL ATWS-koesarjan sopivia paineistinkokeita sekä MIT Pressurizer- ja Neptunus- erilliskokeita. Lisäksi rakennettiin malli Loviisan ydinvoimalaitoksen paineistimesta, jota käytettiin turbiinitrippitransientin simulointiin tarkoituksena selvittää mahdolliset voimalaitoksen ja koelaitteistojen mittakaavaerosta johtuvat vaikutukset APROSin paineistinlaskentaan. Kokeiden simuloinnissa testattiin erilaisia noodituksia ja mallinnusvaihtoehtoja, kuten entalpian ensimmäisen ja toisen kertaluvun diskretisointia, ja APROSin sekä TRACEn antamia tuloksia vertailtiin kattavasti toisiinsa. APROSin paineistinmallin lämmönsiirtokorrelaatioissa havaittiin merkittävä puute ja laskentatuloksiin saatiin huomattava parannus ottamalla käyttöön uusi seinämälauhtumismalli. Työssä tehdyt TRACE-simulaatiot ovat osa United States Nuclear Regulatory Commissionin kansainvälistä CAMP-koodinkehitys-ja validointiohjelmaa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nicotine in a smoky indoor air environment can be determined using graphitized carbon black as a solid sorbent in quartz tubes. The temperature stability, high purity, and heat absorption characteristics of the sorbent, as well as the permeability of the quartz tubes to microwaves, enable the thermal desorption by means of microwaves after active sampling. Permeation and dynamic dilution procedures for the generation of nicotine in the vapor phase at low and high concentrations are used to evaluate the performances of the sampler. Tube preparation is described and the microwave desorption temperature is measured. Breakthrough volume is determined to allow sampling at 0.1-1 L/min for definite periods of time. The procedure is tested for the determination of gas and paticulate phase nicotine in sidestream smoke produced in an experimental chamber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nuclear matrix, a proteinaceous network believed to be a scaffolding structure determining higher-order organization of chromatin, is usually prepared from intact nuclei by a series of extraction steps. In most cell types investigated the nuclear matrix does not spontaneously resist these treatments but must be stabilized before the application of extracting agents. Incubation of isolated nuclei at 37C or 42C in buffers containing Mg++ has been widely employed as stabilizing agent. We have previously demonstrated that heat treatment induces changes in the distribution of three nuclear scaffold proteins in nuclei prepared in the absence of Mg++ ions. We studied whether different concentrations of Mg++ (2.0-5 mM) affect the spatial distribution of nuclear matrix proteins in nuclei isolated from K562 erythroleukemia cells and stabilized by heat at either 37C or 42C. Five proteins were studied, two of which were RNA metabolism-related proteins (a 105-kD component of splicing complexes and an RNP component), one a 126-kD constituent of a class of nuclear bodies, and two were components of the inner matrix network. The localization of proteins was determined by immunofluorescent staining and confocal scanning laser microscope. Mg++ induced significant changes of antigen distribution even at the lowest concentration employed, and these modifications were enhanced in parallel with increase in the concentration of the divalent cation. The different sensitivity to heat stabilization and Mg++ of these nuclear proteins might reflect a different degree of association with the nuclear scaffold and can be closely related to their functional or structural role.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'objectiu del projecte és el disseny d'una unitat d'emmagatzematge d'energia térmica que optimitzi i millori l'eficiència del sistema de climatització. Aquesta unitat contindrà materials de canvi de fase (PCM) per emmagatzemar l'energia i estarà acoblada a un sistema de climatització format per una bomba de calor i una unitat de tractament de l'aire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal energy storage (TES) can increase the thermal energy effieresa, of a process by reusing the waste heat from industrial process, solar energy or other sources. There are different ways to store thermal energy: by sensible heat, by latest heat, by sorption process or by chemical reaction. This thesrs provides a-state-of-the-art review of the experimental performance of TES systems based on solid gas sorption process and chemical reactions. The importance of theses processes is that provides a heat loss free storage system with a high energy density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Commercially available PCM RT 20, RT 27, SP 22, A17 and SP 25 A8. Were analyzed using dynamic and step method of heat flux DSC. The results of the dinamic and step method were compared with commercial valures. It was found that RT 20 & RT 27 showed good conforming of results with commercial values while SP 22 A17 & SP 25 A8 did not show conformity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to improve the thermal performance of commercial freezers using phase change materials (PCM) and the prove the importance of the correct PCM selection (melting temperature) for each application. To do this a vertical freezer with and without macro encapsulation PCM are used to assess the benefits of using PCM in minimizing temperature fluctuations and to maintain at the lowest possible temperature the freezer under heat of losses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Els materials de canvi de fase (PCM) han estat considerats per a l’emmagatzematge tèrmic en edificis des de 1980. Amb la inclusió dels PCM en plaques de guix, guix, formigó o altres materials que s’utilitzen per a cobrir les parets, l’emmagatzematge tèrmic pot ser part de les estructures fins i tot en edificis lleugers. Les noves tècniques de microencapsulació han obert moltes possibilitats en aplicacions per a edificis. El treball que es presenta és el desenvolupament d’un formigó innovador mesclat amb PCM microencapsulat, amb un punt de fusió de 26 oC i una entalpia de canvi de fase de 110 kJ/kg. El primer experiment va ser la inclusió del PCM microencapsulat dins del formigó i la construcció d’una caseta amb aquest nou formigó-PCM. Es va construir una segona caseta al costat de la primera amb les mateixes característiques i orientació però amb formigó convencional que serveix com a referència. Durant els anys 2005 i 2006 es va analitzar el comportament d’ambdues casetes i més tard es va edificar un mur Trombe a la paret sud de totes dues per investigar la seva influència durant la tardor i l’hivern.