980 resultados para Testing aspect-oriented programs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combination of modelling and analysis techniques was used to design a six component force balance. The balance was designed specifically for the measurement of impulsive aerodynamic forces and moments characteristic of hypervelocity shock tunnel testing using the stress wave force measurement technique. Aerodynamic modelling was used to estimate the magnitude and distribution of forces and finite element modelling to determine the mechanical response of proposed balance designs. Simulation of balance performance was based on aerodynamic loads and mechanical responses using convolution techniques. Deconvolution was then used to assess balance performance and to guide further design modifications leading to the final balance design. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A survey (N= 352) was conducted among British passengers of a cross-channel ferry. The survey aimed to test hypotheses drawn from Realistic Group Conflict, Social Identity and Contact theories using mainly a correlational design. However, an intervention by members of the outgroup (French fishermen blockading a port) also allowed a quasi-experimental test of the effects of a direct experience of intergroup conflict. Results supported the hypotheses since conflict and national identification were associated with more negative and with less positive attitudes toward the outgroup, while contact had the reverse effects. In addition, the salience of group membership in the contact relationship weakly moderated the effect of contact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low participation at the employee or worksite level limits the potential public health impact of worksite-based interventions. Ecological models suggest that multiple levels of influence operate to determine participation patterns in worksite health promotion programs. Most investigations into the determinants of low participation study the intrapersonal, interpersonal, and institutional influences on employee participation. Community- and policy-level influences have not received attention, nor has consideration been given to worksite-level participation issues. The purpose of this article is to discuss one macrosocial theoretical perspective—political economy of health—that may guide practitioners and researchers interested in addressing the community- and policy-level determinants of participation in worksite health promotion programs. The authors argue that using theory to investigate the full spectrum of determinants offers a more complete range of intervention and research options for maximizing employee and worksite levels of participation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: (1) To establish test performance measures for Transient Evoked Otoacoustic Emission testing of 6-year-old children in a school setting; (2) To investigate whether Transient Evoked Otoacoustic Emission testing provides a more accurate and effective alternative to a pure tone screening plus tympanometry protocol. Methods: Pure tone screening, tympanometry and transient evoked otoacoustic emission data were collected from 940 subjects (1880 ears), with a mean age of 6.2 years. Subjects were tested in non-sound-treated rooms within 22 schools. Receiver operating characteristics curves along with specificity, sensitivity, accuracy and efficiency values were determined for a variety of transient evoked otoacoustic emission/pure tone screening/tympanometry comparisons. Results: The Transient Evoked Otoacoustic Emission failure rate for the group was 20.3%. The failure rate for pure tone screening was found to be 8.9%, whilst 18.6% of subjects failed a protocol consisting of combined pure tone screening and tympanometry results. In essence, findings from the comparison of overall Transient Evoked Otoacoustic Emission pass/fail with overall pure tone screening pass/fail suggested that use of a modified Rhode Island Hearing Assessment Project criterion would result in a very high probability that a child with a pass result has normal hearing (true negative). However, the hit rate was only moderate. Selection of a signal-to-noise ratio (SNR) criterion set at greater than or equal to 1 dB appeared to provide the best test performance measures for the range of SNR values investigated. Test performance measures generally declined when tympanometry results were included, with the exception of lower false alarm rates and higher positive predictive values. The exclusion of low frequency data from the Transient Evoked Otoacoustic Emission SNR versus pure tone screening analysis resulted in improved performance measures. Conclusions: The present study poses several implications for the clinical implementation of Transient Evoked Otoacoustic Emission screening for entry level school children. Transient Evoked Otoacoustic Emission pass/fail criteria will require revision. The findings of the current investigation offer support to the possible replacement of pure tone screening with Transient Evoked Otoacoustic Emission testing for 6-year-old children. However, they do not suggest the replacement of the pure tone screening plus tympanometry battery. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper aims to describe the historical outline and current development of the educational policy for students with learning difficulties in Australia, focusing especially on the state of Queensland. In order to develop educational policy of learning difficulities at the state level, the concept of learning difficulities had been discussed until the middle of the 1970's. Receiving the submissions which argued strongly against a diagnostically-oriented definition of learning disabilities, the Select Comittee concluded that there was much conceptual confusion regarding the definition and cause of learining difficulties that might take many years to resolve. Despite that it was recongnised that action was needed to assist children by looking at their "total learning environmerit", and recommended the development of an educational policy for students with learning difficulties. During 1980's, support teachers for students with learning difficulties were employed in many schools. Scince the early 1980's support teachers have been making their efforts in regular classrooms rather than in the resource rooms. Their roles have been to help students with learning difficulties using effective and specific skills, and to consult with the regular classroom teacher in solving the problems related to learning difficulties in regular classes. Currently, the support system for students with learning difficulties has been employed to organize a more systematic and broader approach in Queensland based on the accountability of schools. In the context of enphasizing literacy and numeracy, a systematic whole school approach and particular programs, such as the Year 2 Diagnostic Net and Reading Recovery, have been introduced into the educational system for early identification and early intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case study represents four years of audiological observations, testing and aural habilitation of a female child with a partial agenesis of the corpus callosum (ACC). The ACC was diagnosed by MRI scans to eliminate neurological causes for developmental delay at six months of age. This child was also born with a cleft palate and was diagnosed with Robinow Syndrome at 3 years and 3 months of age. The audiological results showed an improvement in hearing thresholds over the four-year period. The child’s opthamologist also reported an improvement in visual skills over time. The most interesting aspect of the child’s hearing was the discrepancy between the monaural and the binaural results. That is, when assessed binaurally she often presented with a mild to moderate mixed loss and when assessed monaurally she showed a moderate to severe mixed loss for the right ear and a severe mixed loss for the left ear. This discrepancy between binaural and monaural results was evident for both aided and unaided tests. Parental reports of the child’s hearing were consistent with the binaural clinical results. This case indicates the need for audiologists to: (a) carefully monitor the hearing of children with ACC, (b) obtain monaural and binaural hearing and aided thresholds results, and (c) compare these children’s functional abilities to the objective test results obtained. This case does question whether hearing aids are appropriate for children with ACC. If hearing aids are deemed to be appropriate, then hearing aids with compression characteristics should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple technique for routine, reproducible global surveillance of the drug susceptibility status of the anaerobic protozoa Trichomonas, Entamoeba, and Giardia is described, Data collected using this technique can be readily compared among different laboratories and with previously reported data. The technique employs a commercially available sachet and bag system to generate a low-oxygen environment and log, drug dilutions in microtiter plates, which can be monitored without aerobic exposure, to assay drug-resistant laboratory lines and clinically resistant isolates. MICs (after 2 days) of 3.2 and 25 muM indicated metronidazole-sensitive and highly clinically resistant isolates of T. vaginalis in anaerobic assays, respectively. The aerobic MICs were 25 and > 200 muM. MICs (1 day) of 12.5 to 25 muM were found for axenic lines of E. histolytica, and MICs for G. duodenalis (3 days) ranged from 6.3 muM for metronidazole-sensitive isolates to 50 muM for laboratory metronidazole-resistant lines. This technique should encourage more extensive monitoring of drug resistance in these organisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare microsatellite instability (MSI) testing with immunohistochemical (IHC) detection of hMLH1 and hMSH2 in colorectal cancer. Patients and Methods: Colorectal cancers from 1, 144 patients were assessed for DNA mismatch repair deficiency by two methods: MSI testing and IHC detection of hMLH1 and hMSH2 gene products. High-frequency MSI (MSI-H) was defined as more than 30% instability of at least five markers; low-level MSI (MSI-L) was defined as 1% to 29% of loci unstable. Results: Of 1, 144 tumors tested, 818 showed intact expression of hMLH1 and hMSH2. Of these, 680 were microsatellite stable (MSS), 27 were MSI-H, and 111 were MSI-L. In all, 228 tumors showed absence of hMLH1 expression and 98 showed absence of hMSH2 expression: all were MSI-H. Conclusion: IHC in colorectal tumors for protein products hMLH1 and hMSH2 provides a rapid, cost-effective, sensitive (92.3%), and extremely specific (100%) method for screening for DNA mismatch repair defects. The predictive value of normal IHC for an MSS/MSI-L phenotype was 96.7%, and the predictive value of abnormal IHC was 100% for an MSI-H phenotype. Testing strategies must take into account acceptability of missing some cases of MSI-H tumors if only IHC is performed. (C) 2002 by American Society of Clinical Oncology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the design and characterisation of a short, and hence portable impact load cell for in-situ quantification of ore breakage properties under impact loading conditions. Much literature has been published in the past two decades about impact load cells for ore breakage testing. It has been conclusively shown that such machines yield significant quantitative energy-fragmentation information about industrial ores. However, documented load cells are all laboratory systems that are not adapted for in-situ testing due to their dimensions and operating requirements. The authors report on a new portable impact load cell designed specifically for in-situ testing. The load cell is 1.5 m in height and weighs 30 kg. Its physical and operating characteristics are detailed in the paper. This includes physical dimensions, calibration and signal deconvolution. Emphasis is placed on the deconvolution issue, which is significant for such a short load cell. Finally, it is conclusively shown that the short load cell is quantitatively as accurate as its larger laboratory analogues. (C) 2062 Elsevier Science B.V. All rights reserved.