999 resultados para Teste de fluxo de dados
Resumo:
Based on climatological data and energy flow, this paper analyzes the behavior observed in microclimatic an important remnant of cerrado in the São Paulo State. The seasonal climate is well marked, in the study area, with two climatic periods (one dry and one wet). The vegetation presents physiology as a function of water availability and the local thermal conditions and can be seen marked changes in the landscape due to the more or less presence of solar radiation. It’s important to understand the ecosystems behave in the context of global change. It has gained the attention of many researchers in the world.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
In this study, we aimed to evaluate the effect of five drying systems on the quality of crambe seed and the influence of the pericarp in its electrical conductivity. The experimental design adopted was randomized blocks with four replications. The following drying methods were applied: drying in the field, on the patio, under shade, with heated air, and non-heated air. To evaluate the electrical conductivity and the fat acidity, the seeds, from the cultivar FMS Brilhante, were analyzed with and without pericarp. . An analysis of variance was performed and the means were compared by Tukey test (p≤0,05). We also performed the Pearson linear correlation between electrical conductivity and fat acidity in order to evaluate the pericarp influence. The 4 drying system using shades cause less damage to the seeds; and the presence of pericarp decreased the sensitivity of the electrical conductivity
Resumo:
The aim of this study was to build and validate a low cost reduced-scale wind tunnel for drift evaluation on pesticide application technology. The work was carried out at the NEMPA - Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA), FCA/UNESP, Departamento de Engenharia Rural, Botucatu/SP, Brazil. The wind tunnel main characteristics were an open circuit and a closed working section with a fan blowing air into the tunnel. Screens were fitted downstream after the fan in order to stabilize the air flow on the working section. The tunnel was built with 3.0 mm eucalyptus hardboard, with a total length of 4.8 m and a squared section of 0.56 m. The air flow was provided by a 180 W axial fan. The system was adjusted and calibrated to provide a laminar and stable flow at 2.0 m s-1. Validation studies were carried out by using a Teejet XR 8003 flat fan nozzle at 200 kPa (medium droplets) to apply a spray solutions containing water plus a food dye (Blue FDC) at 0,6% m v-1 mixed with two adjuvants: a polymer based anti drift formulation at 0,06% m v-1 and a sodium lauryl ether sulfate based surfactant at 0,2% v v-1. After a 10-second application the drift was collected on nylon strips transversally fixed along the tunnel at different distances from the nozzle and different high from the bottom part of the tunnel. Drift deposits were evaluated by spectrophotometry. The wind tunnel had low levels of turbulence and high repeatability of the data, which means that the flow was uniform and able to be used for carrying out measures to estimate drift. The validation results showed that the tunnel was effective to enable comparative drift measurements on the spray solution used in this work making possible the evaluation of drift risk potential under those spray technologies. The use of an adjuvant based on a polymer reduced the amount of drift from the nozzle compared to the surfactant.
Resumo:
This study aimed to evaluate the behavior of the deposition and mechanical damage in seeds using a continuous flow metering system under different slope and speed. Part of the study was conducted at Agricultural Research Foundation Agricultural - (FAPA), where seeds that are deposited by a metering system were collected, and the quality analysis verifying the percentage of mechanical damage were conducted at the Faculty of Agricultural Sciences, UNESP, city of Botucatu– SP. The mechanism deposition was subjected to three different speed conditions (4,7, and 10 km.h-1) and three differents working slopes, ( 3%, 8%, and 16%). The results were submitted to Tukey test (p ≤ 0.05), and an analysis of variance with F test at 5% significance level was performed. The results showed an interaction between the factor slope and speed of work, increasing the metering mechanism speed, results in a reduction of the seed deposition at a 3% slope but a working speed of 10 km h-1did not reduce the rate of seed deposition until the slope reaches 16%. Both the slope factor and the working speed caused at least 3.9 and 4.2% more damage to the seeds, respectively.
Resumo:
Pós-graduação em Ciência da Informação - FFC
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
O índice de volatilidade eleitoral tem sido usado como um dos principais indicadores de institucionalização dos sistemas partidários em países de democracia recente. Contudo, os estudos comparados usualmente analisam esse índice num nível de agregação dos dados muito elevado, avaliando sua variação com base nas médias nacionais. Sob tal perspectiva, nosso objetivo é analisar a volatilidade eleitoral brasileira tomando os 27 entes federativos como unidade de agregação dos dados eleitorais para a Câmara dos Deputados. Na primeira parte do artigo, mostramos que há grande variabilidade no índice entre os estados e entre as sucessivas eleições; na segunda parte, realizamos um teste estatístico do impacto explicativo de variáveis políticas, econômicas e sociais na variação da volatilidade eleitoral em duas dimensões: a temporal (entre as eleições) e a espacial (entre os estados). Os resultados mostram a importância de algumas variáveis políticas na explicação da variação da volatilidade eleitoral brasileira.
Resumo:
A apoptose de leucócitos polimorfonucleares (PMN) é um evento central no processo de resolução da inflamação. Sendo a contagem de células somáticas (CCS) um indicador da situação imunológica da glândula mamária, o presente estudo buscou esclarecer a influência que esses fatores têm um sobre o outro e sobre a evolução do processo inflamatório. Marcaram-se as amostras de leite com anexina-V, iodeto de propídeo (PI), anticorpo anti-CH138A. Encontrou-se correlação negativa entre apoptose de PMN e CCS, além de diferença estatística entre um grupo de alta CCS e um grupo de baixa CCS quanto à taxa de PMN viáveis, em apoptose, em necrose e em necrose e/ou apoptose. De modo geral, o grupo de alta celularidade apresentou menos CH138+ em apoptose e mais células em necrose ou viáveis do que o grupo de baixa celularidade. Conclui-se que apoptose de PMN e CCS estão relacionados, e que em mamas com CCS elevada este evento está diminuído. Apesar de haver maior disponibilidade de fagócitos para a defesa nessa situação, os efeitos anti-inflamatórios da apoptose também estão diminuídos, enquanto os efeitos pró-inflamatórios da necrose estão aumentados, o que pode colaborar com a cronificação da inflamação.
Resumo:
Neste trabalho é proposto um fotômetro baseado em LED (diodo emissor de luz) para fotometria em fase sólida. O fotômetro foi desenvolvido para permitir o acoplamento da fonte de radiação (LED) e do fotodetector direto na cela de fluxo, tendo um caminho óptico de 4 mm. A cela de fluxo foi preenchida com material sólido (C18), o qual foi utilizado para imobilizar o reagente cromogênico 1-(2-tiazolilazo)-2-naftol (TAN). A exatidão foi avaliada empregando dados obtidos através da técnica ICP OES (espectrometria de emissão por plasma indutivamente acoplado). Aplicando-se o teste-t pareado não foi observada diferença significativa em nível de confiança de 95%. Outros parâmetros importantes encontrados foram faixa de resposta linear de 0,05 a 0,85 mg L-1 Zn, limite de detecção de 9 µg L-1 Zn (n = 3), desvio padrão de 1,4 % (n = 10), frequência de amostragem de 36 determinações por h, e uma geração de efluente e consumo de reagente de 1,7 mL e 0,03 µg por determinação, respectivamente.