1000 resultados para Test diagnostique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The detection of rabies antibodies is extremely valuable for epidemiological studies, determination of immune status in man, animals, and for the diagnosis of the disease. Several serological procedures have been described for this purpose. The present study reports a comparison between counterimmunoelectrophoresis test (CIET) and mouse neutralization test (MNT) in the detection of antibodies against rabies virus from 212 serum samples of vaccinated dogs. The agreement between both techniques was 79.7% and a significative association was demonstrated. The correlation coefficients between MNT and the CIET titers was determined considering 88 samples showing positive results in both techniques [CIET = 2 and MNT = 5 (0.13 IU/ml)] and resulted r² = 0.7926 (p < 0.001). The performance of CIET system was technically simple, cheap and rapid, and thereby it could be useful for serological monitoring of dog vaccination campaigns as well as for individual analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the direct-method test of sensitivity to drugs used in the principal tuberculosis treatment regimes, in the Organon Teknika MB/BacT system, we tested 50 sputum samples positive to microscopy taken from patients with pulmonary tuberculosis and with clinical indications for an antibiogram, admitted sequentially for examination during the routine of the reference laboratory. The material was treated v/v with 23% trisodium phosphate solution, incubated for 24 h at 35°C, and neutralized v/v with 20% monosodium phosphate solution. The material was then centrifuged and the sediment inoculated into flasks containing Rifampin - 2 µg/ml, Isoniazid - 0.2 µg/ml, Pyrazinamide - 100 µg/ml, Ethambutol - 2.5 µg/ml, Ethionamide - 1.25 µg/ml, and Streptomycin - 2 µg/ml. The tests were evaluated using the indirect method in the BACTEC 460 TB (Becton Dickinson) system as the gold standard. The results showed that the Rifampin test performed best, i.e., 100% sensitivity at 95% Confidence Interval (82.2-100) and 100% specificity at 95% Confidence Interval (84.5-100), followed by Isoniazid and Pyrazinamide. In this experiment, 92% of the materials showed a final reading in 30 days; this period represents the time for primary isolation as well as the results of the sensitivity profile, and is within Centers for Disease Control and Prevention recommendations regarding time for performance of the antibiogram. The inoculated flasks showed no contamination during the experiment. The MB/BacT is shown to be a reliable, rapid, fully automated nonradiometric system for the tuberculosis antibiogram.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A recombinant-antigen enzyme immunoassay (EIA), BioSCREEN TM anti-Treponema pallidum, was compared favorably with the T. pallidum hemagglutination test, in the detection of specific antibodies in different groups of sera from patients with primary (n = 38), secondary (n = 10), early latent (n = 28) and congenital syphilis (n = 2), patients with leptospirosis ( n= 8), infectious mononucleosis (n = 7), hepatitis (n = 9), diabetes mellitus (n = 11), rheumatoid arthritis (n = 13), leprosy (n = 11), tuberculosis (n = 9), HIV/Aids ( n= 12), systemic lupus erythematosus (n = 4), rheumatic fever (n = 3), old-persons (n = 9), pregnant women (n = 29) and blood donors (n = 164). The coincidence between them was 95.1%. The sensitivity and specificity of the EIA were 93.3% and 95.5%, respectively. Fifteen serum specimens belonging to old-persons, pregnant women, blood donors, and patients with human leptospirosis, hepatitis, diabetes mellitus, tuberculosis and rheumatic fever gave false-positive results by Venereal Disease Research Laboratory and/or Rapid Plasma Reagin. The EIA can be used as alternative method for the serological confirmation of syphilis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the correlation between proportion method with mycobacteria growth indicator tube (MGIT) and E-test for Mycobacterium tuberculosis. Forty clinical isolates were tested. MGIT and E-test with the first line antituberculous drugs correlated with the proportion method. Our results suggested that MGIT and E-test methods can be routinely used instead of the proportion method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high sensitivity and the ability to diagnose schistosomiasis in a very early phase after infection have indicated the detection of IgM antibodies to Schistosoma mansoni gut antigens by the immunofluorescence test (IgM-IFT) as a useful serological test for epidemiological studies in low endemic areas. When applied in a follow-up study for two years, higher rates of seroconversion from IFT negative to positive were observed during the summer months, suggesting seasonal transmission of schistosomiasis in the rural area of the municipality of Itariri (São Paulo, Brazil). In each survey, blood samples from about 600 schoolchildren were collected on filter paper and submitted to IgM-IFT. When the blood samples were classified for the IgM antibody levels, according to the intensity of fluorescent reaction observed at fluorescence microscopy, and correlated to the egg counts in the Kato-Katz positive patients, no association was observed. This observation might suggest that the intensity of fluorescence observed in the IgM-IFT, as an indicator of IgM antibody levels, could not be an useful seroepidemiological marker for classifying areas of low endemicity according to degrees of infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La manometría convencional es el “gold standard” para diagnosticar trastornos motores del esófago, pero la información que da sobre la repercusión funcional de estas alteraciones es escasa. La manometría de alta resolución permite estudiar con detalle la motilidad esofagogástrica mediante la generación de mapas topográficos de presiones desde la orofaringe hasta el estómago. Hipótesis: Si la generación de mapas topográficos de presiones en el esófago mediante manometría de alta resolución demuestra la resistencia al flujo esofagogástrico. Objetivo: Comprobar si un test con sobrecarga de agua puede mostrar la presencia de resistencia al flujo esofagogástrico en pacientes con acalasia. Método: Estudiamos 2 grupos de pacientes con alteración de la motilidad esofágica. Un grupo de 8 pacientes que cumplen criterios manométricos de acalasia y, como grupo control, 8 pacientes con disfunción del peristaltismo esofágico ( DPE). A cada paciente se le realizó un test de sobrecarga que consistía en la ingesta rápida de 200 ml de agua mientras se registraban las presiones esofágicas. Resultados: Los pacientes con acalasia ingirieron el agua más lentamente que los pacientes con DPE (82± 14 seg vs 34± 6 seg, p&0,05). Mientras la unión gastroesofágica (UGE) permaneció contraída en el grupo de pacientes con acalasia (46,6± 6 mm Hg; p&0,05), permaneció relajada durante el tiempo del ingesta en pacientes con DPE ( 16,6 ± 4,7 mm Hg). La unión esófago-gástrica (UGE) experimentó una migración proximal en pacientes con acalasia de 1,3 ± 0 cm mientras que en el grupo control no migró (0 cm; p&0,05). La ingesta de agua se asoció a un incremento de la presión del esófago distal (2 cm por encima de la UGE) significativamente mayor en los pacientes con acalasia que en los pacientes con DPE (42,2 ± 20 vs 9,5± 7,9 mm Hg respectivamente, p&0,05) lo que produjo un incremento del gradiente de presión esófago-gástrico en pacientes con acalasia (16± 0,9 mmHg) que no se observó en los pacientes con DPE (0,1 ± 0,4 mmHg ; p&0,05). Conclusión: Un test con sobrecarga de agua durante la medición de la topografía y de las presiones esofágicas demuestra obstrucción al flujo esofagogástrico en los pacientes con acalasia. Este test podría contribuir a valorar la repercusión funcional en pacientes con acalasia y podría servir para el seguimiento de pacientes con acalasia tratados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Samples from 20 lots of diphtheria-tetanus (adult use dT) vaccine and from 20 lots of diphtheria-tetanus-pertussis (DTP) vaccine were used to standardize and validate the in vitro toxin binding inhibition (ToBI) test for the immunogenicity test of the tetanus component. The levels of tetanus antitoxin obtained by ToBI test were compared to those obtained using the toxin neutralization (TN) test in mice routinely employed to perform the quality control of the tetanus component in adsorbed vaccines. The results ranged from 1.8 to 3.5 IU/ml for dT and 2 to 4 IU/ml for DTP by ToBI test and 1.4 to 3 IU/ml for dT and 1.8 to 3.5 IU/ml for DTP by TN in mice. These results were significantly correlated. From this study, it is concluded that the ToBI test is an alternative to the in vivo neutralization procedure in the immunogenicity test of the tetanus component in adsorbed vaccines. A substantial refinement and a reduction in use of animals can be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The direct agglutination test (DAT) based on a freeze-dried antigen and the rK39 dipstick test were evaluated for the sero-diagnosis of visceral leishmaniasis (VL). The sensitivity and specificity of both tests were determined using sera from confirmed VL patients (n = 21), healthy controls (n = 19) and from patients with other confirmed infectious diseases (n = 42). The DAT had a sensitivity and a specificity of 100%. The rK39 had a sensitivity of 85.7% and a specificity of 82%. Both tests were also used to screen blood samples of confirmed VL patients (n = 15) and serum samples of VL suspects (n = 61). The DAT found all blood samples of confirmed VL patients positive and tested 98.4% of the serum samples of the VL suspects positive. In contrast, rK39 detected in 9/15 blood samples (60%) antibodies against Leishmania chagasi and found 85.3% of the serum samples of the suspected patients positive. Although the rK39 dipstick is more rapid and user friendlier than the DAT, the latter has a superior sensitivity and specificity. Furthermore, the reagents used for DAT do not require cold storage, whereas the buffer of the rK39 must be stored at 4ºC. Therefore, the DAT is the most suitable test for the sero-diagnosis of VL under field conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protecting native biodiversity against alien invasive species requires powerful methods to anticipate these invasions and to protect native species assumed to be at risk. Here, we describe how species distribution models (SDMs) can be used to identify areas predicted as suitable for rare native species and also predicted as highly susceptible to invasion by alien species, at present and under future climate and land-use scenarios. To assess the condition and dynamics of such conflicts, we developed a combined predictive modelling (CPM) approach, which predicts species distributions by combining two SDMs fitted using subsets of predictors classified as acting at either regional or local scales. We illustrate the CPM approach for an alien invader and a rare species associated to similar habitats in northwest Portugal. Combined models predict a wider variety of potential species responses, providing more informative projections of species distributions and future dynamics than traditional, non-combined models. They also provide more informative insight regarding current and future rare-invasive conflict areas. For our studied species, conflict areas of highest conservation relevance are predicted to decrease over the next decade, supporting previous reports that some invasive species may contract their geographic range and impact due to climate change. More generally, our results highlight the more informative character of the combined approach to address practical issues in conservation and management programs, especially those aimed at mitigating the impact of invasive plants, land-use and climate changes in sensitive regions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compares the clientele of a Swiss anonymous test centre with the general population tested. Information was obtained through similar questionnaires submitted to two samples of HIV-tested people aged from 17 to 45 years: the first administered in the context of a general population telephone survey (n = 245) and the second completed during face-to-face interviews of the clientele of an anonymous test centre (n = 250). The test centre sample has higher proportions of younger and single people. Attenders for anonymous testing were more likely to have acquired a new regular partner during the year preceding the interview (48.0% versus 14.4%). These differences remain when controlling for age and gender. Decision to test comes mostly from the respondent's own initiative, but suggestion from a doctor is more frequent in the general population (23.8% versus 0.8%), whereas suggestion from partner or friends is more frequent in the anonymous centre (44.4% versus 3.0%). The anonymous test centre clientele is not different from the general population tested except for the relational situation and origin of decision for testing. The test centre has become a place where the general population finds a response to a situation-specific need for HIV testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neutrality tests in quantitative genetics provide a statistical framework for the detection of selection on polygenic traits in wild populations. However, the existing method based on comparisons of divergence at neutral markers and quantitative traits (Q(st)-F(st)) suffers from several limitations that hinder a clear interpretation of the results with typical empirical designs. In this article, we propose a multivariate extension of this neutrality test based on empirical estimates of the among-populations (D) and within-populations (G) covariance matrices by MANOVA. A simple pattern is expected under neutrality: D = 2F(st)/(1 - F(st))G, so that neutrality implies both proportionality of the two matrices and a specific value of the proportionality coefficient. This pattern is tested using Flury's framework for matrix comparison [common principal-component (CPC) analysis], a well-known tool in G matrix evolution studies. We show the importance of using a Bartlett adjustment of the test for the small sample sizes typically found in empirical studies. We propose a dual test: (i) that the proportionality coefficient is not different from its neutral expectation [2F(st)/(1 - F(st))] and (ii) that the MANOVA estimates of mean square matrices between and among populations are proportional. These two tests combined provide a more stringent test for neutrality than the classic Q(st)-F(st) comparison and avoid several statistical problems. Extensive simulations of realistic empirical designs suggest that these tests correctly detect the expected pattern under neutrality and have enough power to efficiently detect mild to strong selection (homogeneous, heterogeneous, or mixed) when it is occurring on a set of traits. This method also provides a rigorous and quantitative framework for disentangling the effects of different selection regimes and of drift on the evolution of the G matrix. We discuss practical requirements for the proper application of our test in empirical studies and potential extensions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The latex action of Euphorbia splendens var. hislopii (Christ's Crown) against snails Lymnaea columella, intermediate host of Fasciola hepatica, derived from irrigation ditches of the Station of Pisciculture at Universidade Federal Rural do Rio de Janeiro, was studied in the laboratory. Lab bioassays, using aqueous solutions of the latex, varying between 0.1 and 10 mg/l, have proven molluscicidal activity of the product collected on the same day the tests were performed, during the four seasons of the year, finding the following lethal concentrations (LC90): 1.51 mg/l in the spring; 0.55 mg/l in the summer; 0.74 mg/l in the fall and 0.93 mg/l in winter, after 24 h exposure of the snails, showing significant differences among the seasons of the year (ANOVA test, F = 11.01, G.L.= 3/33, p < 0.05), as well as among the concentrations (ANOVA test, F = 27.38, G.L.= 11/33, p < 0.05). In the summer, mortality reached 100% from concentration at 0.6 mg/l, the same during fall and in winter as of 1 mg/l, while in spring it only reached 100% mortality as of 2 mg/l. Mortality in the controls was low, reaching 5% in the summer and winter and 10% in the fall and spring. None of the samples died. During the assay, with an aqueous solution of the latex at a concentration of 5 mg/l, in order to check the time of duration of the product effect, in the laboratory, it was observed that the molluscicidal activity remained stable up to the 15th day after the beginning of the test with 100% mortality of L. columella, gradually losing its effect until the 23rd day, when we no longer observed animal mortality. In the control group, there was a random daily variation in mortality rate ranging 0-50% after 48 h of observation for 30 days.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was conducted to evaluate the frequency of antigenic components recognized by serum IgG antibodies in Western blotting (WB) using a Strongyloides ratti larval extract for the diagnosis of human strongyloidiasis. In addition, the WB results were compared to the enzyme-linked immunosorbent assay (ELISA) and the indirect immunofluorescence antibody test (IFAT) results. Serum samples of 180 individuals were analyzed (80 with strongyloidiasis, 60 with other intestinal parasitoses, and 40 healthy individuals). S. ratti was obtained from fecal culture of experimentally infected Rattus rattus. For IFAT, S. ratti larvae were used as antigen and S. ratti larval antigenic extracts were employed in WB and ELISA. Eleven S. ratti antigenic components were predominantly recognized by IgG antibodies in sera of patients with strongyloidiasis. There was a positive concordance for the three tests in 87.5% of the cases of strongyloidiasis. The negative concordance in the three tests was 94% and 97.5%, in patients with other intestinal parasitoses and healthy individuals, respectively. In cases of positive ELISA and negative IFAT results, diagnosis could be confirmed by WB. ELISA, IFAT, and WB using S. ratti antigens showed a high rate of sensitivity and specificity. In conclusion, WB using S. ratti larval extract was able to recognize 11 immunodominant antigenic components, showing to be a useful tool to define the diagnosis in cases of equivocal serology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This leaflet is used to support the Northern Ireland breast screening programme and is issued to the one in 20 women who are called back after their initial breast x-ray for further tests at a breast assessment clinic