907 resultados para System safety


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES This study sought to describe the frequency and clinical impact of acute scaffold disruption and late strut discontinuity of the second-generation Absorb bioresorbable polymeric vascular scaffolds (Absorb BVS, Abbott Vascular, Santa Clara, California) in the ABSORB (A Clinical Evaluation of the Bioabsorbable Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) cohort B study by optical coherence tomography (OCT) post-procedure and at 6, 12, 24, and 36 months. BACKGROUND Fully bioresorbable scaffolds are a novel approach to treatment for coronary narrowing that provides transient vessel support with drug delivery capability without the long-term limitations of metallic drug-eluting stents. However, a potential drawback of the bioresorbable scaffold is the potential for disruption of the strut network when overexpanded. Conversely, the structural discontinuity of the polymeric struts at a late stage is a biologically programmed fate of the scaffold during the course of bioresorption. METHODS The ABSORB cohort B trial is a multicenter single-arm trial assessing the safety and performance of the Absorb BVS in the treatment of 101 patients with de novo native coronary artery lesions. The current analysis included 51 patients with 143 OCT pullbacks who underwent OCT at baseline and follow-up. The presence of acute disruption or late discontinuities was diagnosed by the presence on OCT of stacked, overhung struts or isolated intraluminal struts disconnected from the expected circularity of the device. RESULTS Of 51 patients with OCT imaging post-procedure, acute scaffold disruption was observed in 2 patients (3.9%), which could be related to overexpansion of the scaffold at the time of implantation. One patient had a target lesion revascularization that was presumably related to the disruption. Of 49 patients without acute disruption, late discontinuities were observed in 21 patients. There were no major adverse cardiac events associated with this finding except for 1 patient who had a non-ischemia-driven target lesion revascularization. CONCLUSIONS Acute scaffold disruption is a rare iatrogenic phenomenon that has been anecdotally associated with anginal symptoms, whereas late strut discontinuity is observed in approximately 40% of patients and could be viewed as a serendipitous OCT finding of a normal bioresorption process without clinical implications. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid and simple DNA labeling system has been developed for disposable microarrays and has been validated for the detection of 117 antibiotic resistance genes abundant in Gram-positive bacteria. The DNA was fragmented and amplified using phi-29 polymerase and random primers with linkers. Labeling and further amplification were then performed by classic PCR amplification using biotinylated primers specific for the linkers. The microarray developed by Perreten et al. (Perreten, V., Vorlet-Fawer, L., Slickers, P., Ehricht, R., Kuhnert, P., Frey, J., 2005. Microarray-based detection of 90 antibiotic resistance genes of gram-positive bacteria. J.Clin.Microbiol. 43, 2291-2302.) was improved by additional oligonucleotides. A total of 244 oligonucleotides (26 to 37 nucleotide length and with similar melting temperatures) were spotted on the microarray, including genes conferring resistance to clinically important antibiotic classes like β-lactams, macrolides, aminoglycosides, glycopeptides and tetracyclines. Each antibiotic resistance gene is represented by at least 2 oligonucleotides designed from consensus sequences of gene families. The specificity of the oligonucleotides and the quality of the amplification and labeling were verified by analysis of a collection of 65 strains belonging to 24 species. Association between genotype and phenotype was verified for 6 antibiotics using 77 Staphylococcus strains belonging to different species and revealed 95% test specificity and a 93% predictive value of a positive test. The DNA labeling and amplification is independent of the species and of the target genes and could be used for different types of microarrays. This system has also the advantage to detect several genes within one bacterium at once, like in Staphylococcus aureus strain BM3318, in which up to 15 genes were detected. This new microarray-based detection system offers a large potential for applications in clinical diagnostic, basic research, food safety and surveillance programs for antimicrobial resistance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Stroke is a major cause of morbidity and mortality during open-heart surgery. Up to 60% of intraoperative cerebral events are emboli induced. This randomized, controlled, multicenter trial is the first human study evaluating the safety and efficacy of a novel aortic cannula producing simultaneous forward flow and backward suction for extracting solid and gaseous emboli from the ascending aorta and aortic arch upon their intraoperative release. METHODS Sixty-six patients (25 females; 68±10 years) undergoing elective aortic valve replacement surgery, with or without coronary artery bypass graft surgery, were randomized to the use of the CardioGard (CardioGard Medical, Or-Yehuda, Israel) Emboli Protection cannula ("treatment") or a standard ("control") aortic cannula. The primary endpoint was the volume of new brain lesions measured by diffusion-weighted magnetic resonance imaging (DW-MRI), performed preoperatively and postoperatively. Device safety was investigated by comparisons of complications rate, namely neurologic events, stroke, renal insufficiency and death. RESULTS Of 66 patients (34 in the treatment group), 51 completed the presurgery and postsurgery MRI (27 in the treatment group). The volume of new brain lesion for the treatment group was (mean±standard error of the mean) 44.00±64.00 versus 126.56±28.74 mm3 in the control group (p=0.004). Of the treatment group, 41% demonstrated new postoperative lesions versus 66% in the control group (p=0.03). The complication rate was comparable in both groups. CONCLUSIONS The CardioGard cannula is safe and efficient in use during open-heart surgery. Efficacy was demonstrated by the removal of a substantial amount of emboli, a significant reduction in the volume of new brain lesions, and the percentage of patients experiencing new brain lesions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of direct cochlear access (DCA) is to replace the standard mastoidectomy with a small diameter tunnel from the lateral bone surface to the cochlea for electrode array insertion. In contrast to previous attempts, the approach described in this work not only achieves an unprecedented high accuracy, but also contains several safety sub-systems. This paper provides a brief description of the system components, and summarizes accuracy results using the system in a cadaver model over the past two years.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To evaluate the accuracy, safety, and efficacy of cervical nerve root injection therapy using magnetic resonance guidance in an open 1.0 T MRI system. METHODS Between September 2009 and April 2012, a total of 21 patients (9 men, 12 women; mean age 47.1 ± 11.1 years) underwent MR-guided cervical periradicular injection for cervical radicular pain in an open 1.0 T system. An interactive proton density-weighted turbo spin echo (PDw TSE) sequence was used for real-time guidance of the MR-compatible 20-gauge injection needle. Clinical outcome was evaluated on a verbal numeric rating scale (VNRS) before injection therapy (baseline) and at 1 week and 1, 3, and 6 months during follow-up. RESULTS All procedures were technically successful and there were no major complications. The mean preinterventional VNRS score was 7.42 and exhibited a statistically significant decrease (P < 0.001) at all follow-up time points: 3.86 ± 1.53 at 1 week, 3.21 ± 2.19 at 1 month, 2.58 ± 2.54 at 3 months, and 2.76 ± 2.63 at 6 months. At 6 months, 14.3 % of the patients reported complete resolution of radicular pain and 38.1 % each had either significant (4-8 VNRS score points) or mild (1-3 VNRS score points) relief of pain; 9.5 % experienced no pain relief. CONCLUSION Magnetic resonance fluoroscopy-guided periradicular cervical spine injection is an accurate, safe, and efficacious treatment option for patients with cervical radicular pain. The technique may be a promising alternative to fluoroscopy- or CT-guided injections of the cervical spine, especially in young patients and in patients requiring repeat injections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Correct predictions of future blood glucose levels in individuals with Type 1 Diabetes (T1D) can be used to provide early warning of upcoming hypo-/hyperglycemic events and thus to improve the patient's safety. To increase prediction accuracy and efficiency, various approaches have been proposed which combine multiple predictors to produce superior results compared to single predictors. Three methods for model fusion are presented and comparatively assessed. Data from 23 T1D subjects under sensor-augmented pump (SAP) therapy were used in two adaptive data-driven models (an autoregressive model with output correction - cARX, and a recurrent neural network - RNN). Data fusion techniques based on i) Dempster-Shafer Evidential Theory (DST), ii) Genetic Algorithms (GA), and iii) Genetic Programming (GP) were used to merge the complimentary performances of the prediction models. The fused output is used in a warning algorithm to issue alarms of upcoming hypo-/hyperglycemic events. The fusion schemes showed improved performance with lower root mean square errors, lower time lags, and higher correlation. In the warning algorithm, median daily false alarms (DFA) of 0.25%, and 100% correct alarms (CA) were obtained for both event types. The detection times (DT) before occurrence of events were 13.0 and 12.1 min respectively for hypo-/hyperglycemic events. Compared to the cARX and RNN models, and a linear fusion of the two, the proposed fusion schemes represents a significant improvement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The pararectus approach has been validated for managing acetabular fractures. We hypothesised it might be an alternative approach for performing periacetabular osteotomy (PAO). METHODS Using four cadaver specimens, we randomly performed PAO through either the pararectus or a modified Smith-Petersen (SP) approach. We assessed technical feasibility and safety. Furthermore, we controlled fragment mobility using a surgical navigation system and compared mobility between approaches. The navigation system's accuracy was tested by cross-examination with validated preoperative planning software. RESULTS The pararectus approach is technically feasible, allowing for adequate exposure, safe osteotomies and excellent control of structures at risk. Fragment mobility is equal to that achieved through the SP approach. Validation of these measurements yielded a mean difference of less <1 mm without statistical significance. CONCLUSION Experimental data suggests the pararectus approach might be an alternative approach for performing PAO. Clinical validation is necessary to confirm these promising preliminary results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND REG1 is a novel anticoagulation system consisting of pegnivacogin, an RNA aptamer inhibitor of coagulation factor IXa, and anivamersen, a complementary sequence reversal oligonucleotide. We tested the hypothesis that near complete inhibition of factor IXa with pegnivacogin during percutaneous coronary intervention, followed by partial reversal with anivamersen, would reduce ischaemic events compared with bivalirudin, without increasing bleeding. METHODS We did a randomised, open-label, active-controlled, multicentre, superiority trial to compare REG1 with bivalirudin at 225 hospitals in North America and Europe. We planned to randomly allocate 13,200 patients undergoing percutaneous coronary intervention in a 1:1 ratio to either REG1 (pegnivacogin 1 mg/kg bolus [>99% factor IXa inhibition] followed by 80% reversal with anivamersen after percutaneous coronary intervention) or bivalirudin. Exclusion criteria included ST segment elevation myocardial infarction within 48 h. The primary efficacy endpoint was the composite of all-cause death, myocardial infarction, stroke, and unplanned target lesion revascularisation by day 3 after randomisation. The principal safety endpoint was major bleeding. Analysis was by intention to treat. This trial is registered at ClinicalTrials.gov, identifier NCT01848106. The trial was terminated early after enrolment of 3232 patients due to severe allergic reactions. FINDINGS 1616 patients were allocated REG1 and 1616 were assigned bivalirudin, of whom 1605 and 1601 patients, respectively, received the assigned treatment. Severe allergic reactions were reported in ten (1%) of 1605 patients receiving REG1 versus one (<1%) of 1601 patients treated with bivalirudin. The composite primary endpoint did not differ between groups, with 108 (7%) of 1616 patients assigned REG1 and 103 (6%) of 1616 allocated bivalirudin reporting a primary endpoint event (odds ratio [OR] 1·05, 95% CI 0·80-1·39; p=0·72). Major bleeding was similar between treatment groups (seven [<1%] of 1605 receiving REG1 vs two [<1%] of 1601 treated with bivalirudin; OR 3·49, 95% CI 0·73-16·82; p=0·10), but major or minor bleeding was increased with REG1 (104 [6%] vs 65 [4%]; 1·64, 1·19-2·25; p=0·002). INTERPRETATION The reversible factor IXa inhibitor REG1, as currently formulated, is associated with severe allergic reactions. Although statistical power was limited because of early termination, there was no evidence that REG1 reduced ischaemic events or bleeding compared with bivalirudin. FUNDING Regado Biosciences Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND National safety alert systems publish relevant information to improve patient safety in hospitals. However, the information has to be transformed into local action to have an effect on patient safety. We studied three research questions: How do Swiss healthcare quality and risk managers (qm/rm(1)) see their own role in learning from safety alerts issued by the Swiss national voluntary reporting and analysis system? What are their attitudes towards and evaluations of the alerts, and which types of improvement actions were fostered by the safety alerts? METHODS A survey was developed and applied to Swiss healthcare risk and quality managers, with a response rate of 39 % (n=116). Descriptive statistics are presented. RESULTS The qm/rm disseminate and communicate with a broad variety of professional groups about the alerts. While most respondents felt that they should know the alerts and their contents, only a part of them felt responsible for driving organizational change based on the recommendations. However, most respondents used safety alerts to back up their own patient safety goals. The alerts were evaluated positively on various dimensions such as usefulness and were considered as standards of good practice by the majority of the respondents. A range of organizational responses was applied, with disseminating information being the most common. An active role is related to using safety alerts for backing up own patient safety goals. CONCLUSIONS To support an active role of qm/rm in their hospital's learning from safety alerts, appropriate organizational structures should be developed. Furthermore, they could be given special information or training to act as an information hub on the issues discussed in the alerts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this research and development project was to develop a method, a design, and a prototype for gathering, managing, and presenting data about occupational injuries.^ State-of-the-art systems analysis and design methodologies were applied to the long standing problem in the field of occupational safety and health of processing workplace injuries data into information for safety and health program management as well as preliminary research about accident etiologies. The top-down planning and bottom-up implementation approach was utilized to design an occupational injury management information system. A description of a managerial control system and a comprehensive system to integrate safety and health program management was provided.^ The project showed that current management information systems (MIS) theory and methods could be applied successfully to the problems of employee injury surveillance and control program performance evaluation. The model developed in the first section was applied at The University of Texas Health Science Center at Houston (UTHSCH).^ The system in current use at the UTHSCH was described and evaluated, and a prototype was developed for the UTHSCH. The prototype incorporated procedures for collecting, storing, and retrieving records of injuries and the procedures necessary to prepare reports, analyses, and graphics for management in the Health Science Center. Examples of reports, analyses, and graphics presenting UTHSCH and computer generated data were included.^ It was concluded that a pilot test of this MIS should be implemented and evaluated at the UTHSCH and other settings. Further research and development efforts for the total safety and health management information systems, control systems, component systems, and variable selection should be pursued. Finally, integration of the safety and health program MIS into the comprehensive or executive MIS was recommended. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It’s been three months since we’ve gone live with Patient Safety Net, and it has been a great success! Managers and front line staff have been trained on how to input, review, and submit event reports that formerly were detailed on the hard copy “RIR” forms. Utilization of the webbased PSN system has been better than expected. PSN has enabled us to greatly improve the way we document and react to patient safety related events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Material Safety Data Sheets (MSDSs) are an integral component of occupational hazard communication systems. These documents are used to disseminate hazard information to workers on chemical substances. The primary purpose of this study was to investigate the comprehensibility of MSDSs by workers at an international level. ^ A total of 117 employees of a multi-national petrochemical company participated; thirty-nine (39) each in the United States, Canada and the United Kingdom. Overall participation rate of those approached to participate was 82%. These countries were selected as they each utilize one of the three major existing hazard communication systems for fixed workplaces. The systems are comprised of the Occupational Safety and Health Administration's Hazard Communication Standard in the United States, the Workplace Hazardous Materials Information System (WHMIS) in Canada, and the compilation of several European Union directives addressing classification, labeling of substances and preparations, and MSDSs in Europe. ^ A pretest posttest randomized study design was used, with the posttest being comparable to an open book test. The results of this research indicated that only about two-thirds of the information on the MSDSs was comprehended by the workers with a significant difference identified among study participants based on country comparisons. This data was fairly consistent with the results of previous MSDS comprehensibility studies conducted in the United States. There was no significant difference in the comprehension level among study participants when taking into account the international hazard communication standard that the MSDS complied with. Marginally, age, education level and experience level did not have a significant impact on the comprehension level. ^ Participants did find MSDSs to be satisfactory in providing the information needed to protect them regardless of their views on the readability and formatting of MSDSs. The health-related information was the least comprehended as less than half of it was comprehended on the basis of the responses. The findings from this research suggest that there is much work needed yet to make MSDSs more comprehensible on a global basis, particularly regarding health-related information. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using newly constructed data series on explosions, deaths, and steamboat traffic, we examine econometrically the causes of increased safety in steamboat boilers in the nineteenth century. Although the law of 1852 (but not that of 1838) did have a dramatic initial effect in reducing explosions, that reduction came against the background not of a system out of control but of a system that from the beginning was steadily increasing boiler safety per person- mile. The role of the federal government in conducting and disseminating basic research on boiler technology may have been more significant for increased safety than its explicit regulatory efforts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Institutional Review Boards (IRBs) are the primary gatekeepers for the protection of ethical standards of federally regulated research on human subjects in this country. This paper focuses on what general, broad measures that may be instituted or enhanced to exemplify a "model IRB". This is done by examining the current regulatory standards of federally regulated IRBs, not private or commercial boards, and how many of those standards have been found either inadequate or not generally understood or followed. The analysis includes suggestions on how to bring about changes in order to make the IRB process more efficient, less subject to litigation, and create standardized educational protocols for members. The paper also considers how to include better oversight for multi-center research, increased centralization of IRBs, utilization of Data Safety Monitoring Boards when necessary, payment for research protocol review, voluntary accreditation, and the institution of evaluation/quality assurance programs. ^ This is a policy study utilizing secondary analysis of publicly available data. Therefore, the research for this paper focuses on scholarly medical/legal journals, web information from the Department of Health and Human Services, Federal Drug Administration, and the Office of the Inspector General, Accreditation Programs, law review articles, and current regulations applicable to the relevant portions of the paper. ^ Two issues are found to be consistently cited by the literature as major concerns. One is a need for basic, standardized educational requirements across all IRBs and its members, and secondly, much stricter and more informed management of continuing research. There is no federally regulated formal education system currently in place for IRB members, except for certain NIH-based trials. Also, IRBs are not keeping up with research once a study has begun, and although regulated to do so, it does not appear to be a great priority. This is the area most in danger of increased litigation. Other issues such as voluntary accreditation and outcomes evaluation are slowing gaining steam as the processes are becoming more available and more sought after, such as JCAHO accrediting of hospitals. ^ Adopting the principles discussed in this paper should promote better use of a local IRBs time, money, and expertise for protecting the vulnerable population in their care. Without further improvements to the system, there is concern that private and commercial IRBs will attempt to create a monopoly on much of the clinical research in the future as they are not as heavily regulated and can therefore offer companies quicker and more convenient reviews. IRBs need to consider the advantages of charging for their unique and important services as a cost of doing business. More importantly, there must be a minimum standard of education for all IRB members in the area of the ethical standards of human research and a greater emphasis placed on the follow-up of ongoing research as this is the most critical time for study participants and may soon lead to the largest area for litigation. Additionally, there should be a centralized IRB for multi-site trials or a study website with important information affecting the trial in real time. There needs to be development of standards and metrics to assess the performance of the IRBs for quality assurance and outcome evaluations. The boards should not be content to run the business of human subjects' research without determining how well that function is actually being carried out. It is important that federally regulated IRBs provide excellence in human research and promote those values most important to the public at large.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. In 2003, the State of Texas instituted the Driver Responsibility Program (TDRP), a program consisting of a driving infraction point system coupled with a series of graded fines and annual surcharges for specific traffic violations such as driving while intoxicated (DWI). Approximately half of the revenues generated are earmarked to be disbursed to the state's trauma system to cover uncompensated trauma care costs. This study examined initial program implementation, the impact of trauma system funding, and initial impact on impaired driving knowledge, attitudes and behaviors. A model for targeted media campaigns to improve the program's deterrence effects was developed. ^ Methods. Data from two independent driver survey samples (conducted in 1999 and 2005), department of public safety records, state health department data and a state auditor's report were used to evaluate the program's initial implementation, impact and outcome with respect to drivers' impaired driving knowledge, attitudes and behavior (based on constructs of social cognitive theory) and hospital uncompensated trauma care funding. Survey results were used to develop a regression model of high risk drivers who should be targeted to improve program outcome with respect to deterring impaired driving. ^ Results. Low driver compliance with fee payment (28%) and program implementation problems were associated with lower surcharge revenues in the first two years ($59.5 million versus $525 million predicted). Program revenue distribution to trauma hospitals was associated with a 16% increase in designated trauma centers. Survey data demonstrated that only 28% of drivers are aware of the TDRP and that there has been no initial impact on impaired driving behavior. Logistical regression modeling suggested that target media campaigns highlighting the likelihood of DWI detection by law enforcement and the increased surcharges associated with the TDRP are required to deter impaired driving. ^ Conclusions. Although the TDRP raised nearly $60 million in surcharge revenue for the Texas trauma system over the first two years, this study did not find evidence of a change in impaired driving knowledge, attitudes or behaviors from 1999 to 2005. Further research is required to measure whether the program is associated with decreased alcohol-related traffic fatalities. ^