872 resultados para Silver concentration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of sucrose concentration in the culture medium on growth and on the establishment of mycorrhizas during the acclimatization of pineapple cv. Pérola. The plantlets were micropropagated in MS culture medium with 0, 10, 20 and 30 g L-1 of sucrose and then they were acclimatized during 12 weeks under greenhouse conditions, in a sandy soil - compost mixture, uninoculated or inoculated with a Rhizophagus clarus isolate. Plantlets from the culture medium with 20 g and 30 g of sucrose L-1 showed higher shoot and root biomass than those from sugar-free medium. Mycorrhizal colonization was lower in plantlets micropropagated in sucrose-free medium, but the intensity of arbuscules did not differ among treatments. In the 12-week period of acclimatization, mycorrhizal colonization had no effect on plant biomass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Isoelectric focusing of human urinary metallothionein at a pH range of 4.8 to 7.0 yielded a single protein band with a pI of 5.57 which co-migrated with authentic purified metallothionein I from human liver. Minimum pretreatment of the urine samples (160 ml) was needed. The preparatory steps included sample concentration with the original protein, enriched from 69 +/- 23 micrograms/ml to 2.0 +/- 1.4 mg/ml (+/- SD; n = 9), followed by heat treatment at 80 degrees C for 5 min (2.4 +/- 1.7 mg protein/ml). After focusing, the gels were stained with silver and the lanes were scanned with a laser scanner. Peak areas were used for quantitation with commercial beta 2-microglobulin as a standard. The urinary metallothionein ranged from 1.0 to 2.6 nmol/mmol creatinine, which is comparable with values reached by radio-immunoassay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective:To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality.Materials and Methods:Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration.Results:As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions.Conclusion:Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper empirically analyzes changes in the supply of non-stop intercontinental flights from European airports. We take advantage of OAG data for air services from a rich sample of European airports to intercontinental destinations in the period 2004-2008. Results of the empirical analysis indicate a tendency towards a more balanced distribution of intercontinental flights across European airports. We also find that the demographic size of a region, its sector specialization, the political role of its central city and the proportion of connecting traffic explain the amount of and changes in long-haul air services supplied from European airports.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection spectrophotometric procedure exploiting merging zones is proposed for determining vitamin B2 (riboflavin) in pharmaceutical preparations. The determination is based on the red-colored complex formation between vitamin B2 and silver(I) which was measured at 520 nm. Vitamin B2 was determined in four pharmaceutical preparations in the 1.0 to 50.0 mg L-1 concentration range, with a detection limit of 0.5 mg L-1. The recovery from three samples ranged from 98.0 to 104.0 %. The analytical frequency was 42 h-1 and r.s.d. were lower than 1% for solutions containing 10.0, 30.0 and 50.0 mg L-1 vitamin B2 (n= 10). The results obtained in commercial formulations using the FIA procedure were in good agreement with those obtained by using a conventional fluorimetric procedure (r=0.9998) and also with the label values (r= 0.9997).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Viruses are among the most important pathogens present in water contaminated with feces or urine and represent a serious risk to human health. Four procedures for concentrating viruses from sewage have been compared in this work, three of which were developed in the present study. Viruses were quantified using PCR techniques. According to statistical analysis and the sensitivity to detect human adenoviruses (HAdV), JC polyomaviruses (JCPyV) and noroviruses genogroup II (NoV GGII): (i) a new procedure (elution and skimmed-milk flocculation procedure (ESMP)) based on the elution of the viruses with glycine-alkaline buffer followed by organic flocculation with skimmed-milk was found to be the most efficient method when compared to (ii) ultrafiltration and glycine-alkaline elution, (iii) a lyophilization-based method and (iv) ultracentrifugation and glycine-alkaline elution. Through the analysis of replicate sewage samples, ESMP showed reproducible results with a coefficient of variation (CV) of 16% for HAdV, 12% for JCPyV and 17% for NoV GGII. Using spiked samples, the viral recoveries were estimated at 30-95% for HAdV, 55-90% for JCPyV and 45-50% for NoV GGII. ESMP was validated in a field study using twelve 24-h composite sewage samples collected in an urban sewage treatment plant in the North of Spain that reported 100% positive samples with mean values of HAdV, JCPyV and NoV GGII similar to those observed in other studies. Although all of the methods compared in this work yield consistently high values of virus detection and recovery in urban sewage, some require expensive laboratory equipment. ESMP is an effective low-cost procedure which allows a large number of samples to be processed simultaneously and is easily standardizable for its performance in a routine laboratory working in water monitoring. Moreover, in the present study, a CV was applied and proposed as a parameter to evaluate and compare the methods for detecting viruses in sewage samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Viruses are among the most important pathogens present in water contaminated with feces or urine and represent a serious risk to human health. Four procedures for concentrating viruses from sewage have been compared in this work, three of which were developed in the present study. Viruses were quantified using PCR techniques. According to statistical analysis and the sensitivity to detect human adenoviruses (HAdV), JC polyomaviruses (JCPyV) and noroviruses genogroup II (NoV GGII): (i) a new procedure (elution and skimmed-milk flocculation procedure (ESMP)) based on the elution of the viruses with glycine-alkaline buffer followed by organic flocculation with skimmed-milk was found to be the most efficient method when compared to (ii) ultrafiltration and glycine-alkaline elution, (iii) a lyophilization-based method and (iv) ultracentrifugation and glycine-alkaline elution. Through the analysis of replicate sewage samples, ESMP showed reproducible results with a coefficient of variation (CV) of 16% for HAdV, 12% for JCPyV and 17% for NoV GGII. Using spiked samples, the viral recoveries were estimated at 30-95% for HAdV, 55-90% for JCPyV and 45-50% for NoV GGII. ESMP was validated in a field study using twelve 24-h composite sewage samples collected in an urban sewage treatment plant in the North of Spain that reported 100% positive samples with mean values of HAdV, JCPyV and NoV GGII similar to those observed in other studies. Although all of the methods compared in this work yield consistently high values of virus detection and recovery in urban sewage, some require expensive laboratory equipment. ESMP is an effective low-cost procedure which allows a large number of samples to be processed simultaneously and is easily standardizable for its performance in a routine laboratory working in water monitoring. Moreover, in the present study, a CV was applied and proposed as a parameter to evaluate and compare the methods for detecting viruses in sewage samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our first objective is to compare the degree of concentration in manufacturing and services, with special emphasis on its evolution in these two sectors, using a sensitivity analysis for different concentration indices and different geographic units of analysis: municipalities and local labour systems of Catalonia in 1991 and 2001. Most concentration measures fail to consider the space in which a particular municipality is located. Our second objective is to overcome this problem by applying two different techniques: by using a clustering measure, and by analysing whether the location quotients computed for each municipality and sector present some kind of spatial autocorrelation process. We take special account of the differences in patterns of concentration according to the technological level of the sectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports a bacteria autonomous controlled concentrator prototype with a user-friendly interface for bench-top applications. It is based on a micro-fluidic lab-on-a-chip and its associated custom instrumentation, which consists in a dielectrophoretic actuator, to pre-concentrate the sample, and an impedance analyser, to measure concentrated bacteria levels. The system is composed by a single micro-fluidic chamber with interdigitated electrodes and a instrumentation with custom electronics. The prototype is supported by a real-time platform connected to a remote computer, which automatically controls the system and displays impedance data used to monitor the status of bacteria accumulation on-chip. The system automates the whole concentrating operation. Performance has been studied for controlled volumes of Escherichia coli (E. coli) samples injected into the micro-fluidic chip at constant flow rate of 10 μL/min. A media conductivity correcting protocol has been developed, as the preliminary results showed distortion of the impedance analyser measurement produced by bacterial media conductivity variations through time. With the correcting protocol, the measured impedance values were related to the quantity of bacteria concentrated with a correlation of 0.988 and a coefficient of variation of 3.1%. Feasibility of E. coli on-chip automated concentration, using the miniaturized system, has been demonstrated. Furthermore, the impedance monitoring protocol had been adjusted and optimized, to handle changes in the electrical properties of the bacteria media over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, accurate and precise flow-injection turbidimetric procedure for the determination of fluoxetine hydrochloride in pharmaceutical formulations is reported. The procedure is based on the precipitation of chloride of fluoxetine hydrochloride with silver nitrate solution and the yielded insoluble AgCl(s) was monitored at 420 nm. The analytical curve was linear in the fluoxetine hydrochloride concentration range 3.0 x 10-5 - 5.0 x 10-4 mol L-1 with a detection limit of 10 µmol L-1 and, a sample throughout of 60 h-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silver containing heavy metal oxide glasses and glass ceramics of the system WO3-SbPO4-PbO-AgCl with different AgCl contents have been prepared and their thermal, structural and optical properties characterized. Glass ceramics containing metallic silver nanoparticles have been prepared by annealing glass samples at temperatures above the glass transition and analyzed by transmission electron microscopy and energy dispersive X-ray microanalysis. The presence of the metallic clusters has been also confirmed by the observation of a surface plasmon resonance band in the visible range. Cyclic voltammetric measurements indicated the presence of metallic silver into the glasses, even before to perform the thermal treatment.