938 resultados para Sensors and interfaces


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work, a norfloxacin selective modified glassy carbon electrode (GCE) based on a molecularly imprinted polymer (MIP) as electrochemical sensor was developed. A suspension of multi-walled carbon nanotubes (MWCNTs) was deposited on the electrode surface. Subsequently, a molecularly imprinted film was prepared by electropolymerization, via cyclic voltammetry of pyrrole (PPy) in the presence of norfloxacin (NFX) as the template molecule. A control electrode (NIP) was also prepared. Scanning electron microscopy (SEM) and cyclic voltammetry in a ferrocyanide solution were performed for morphological and electrochemical characterisation, respectively. Several experimental parameters were studied and optimised. For quantification purposes the MIP/MWCNT/GCE was immersed in NFX solutions for 10 min, and the detection was performed in voltammetric cell by square wave voltammetry. The proposed sensor presented a linear behaviour, between peak current intensity and logarithmic concentration of NFX between 1 × 10−7 and 8 × 10−6 M. The obtained results presented good precision, with a repeatability of 4.3% and reproducibility of 9% and the detection limit was 4.6 × 10−8 M (S/N = 3). The developed sensor displayed good selectivity and operational lifetime, is simple to fabricate and easy to operate and was successfully applied to the analysis of NFX in urine samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pretende-se, na presente dissertação, descrever o trabalho desenvolvido e os conhecimentos adquiridos no decorrer do projeto “iCOPE”, realizado no âmbito do curso de Mestrado em Engenharia de Computação e Instrumentação Médica. O projeto consistiu no desenvolvimento de um sistema aplicacional para o auxílio à prestação de serviços e cuidados de saúde a pacientes com doenças psicóticas tanto através de ferramentas de autogestão, como por funcionalidades que permitirão a um terapeuta monitorizar as ocorrências comunicadas pelos respetivos pacientes atribuídos. As tarefas à responsabilidade do autor desta dissertação compreenderam o levantamento e especificação de requisitos funcionais, o desenvolvimento das funcionalidades e interfaces de gestão de utilizadores e administração do sistema, o desenvolvimento das funcionalidades e interfaces para utilização pelos terapeutas e a criação de ferramentas para a instalação do servidor aplicacional central, existindo ainda cooperação no desenvolvimento de funcionalidades e interfaces para utilização pelos pacientes, nomeadamente ao nível da modelização da base de dados e na realização de testes e deteção de erros. Os resultados da avaliação das interfaces desenvolvidas, obtidos por meio da análise de respostas dadas por um grupo de potenciais utilizadores a um inquérito de usabilidade anónimo, demonstraram que estes estão satisfeitos com a solução implementada, havendo, no entanto, margem para futuros melhoramentos e incremento de funcionalidades.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nowadays, several sensors and mechanisms are available to estimate a mobile robot trajectory and location with respect to its surroundings. Usually absolute positioning mechanisms are the most accurate, but they also are the most expensive ones, and require pre installed equipment in the environment. Therefore, a system capable of measuring its motion and location within the environment (relative positioning) has been a research goal since the beginning of autonomous vehicles. With the increasing of the computational performance, computer vision has become faster and, therefore, became possible to incorporate it in a mobile robot. In visual odometry feature based approaches, the model estimation requires absence of feature association outliers for an accurate motion. Outliers rejection is a delicate process considering there is always a trade-off between speed and reliability of the system. This dissertation proposes an indoor 2D position system using Visual Odometry. The mobile robot has a camera pointed to the ceiling, for image analysis. As requirements, the ceiling and the oor (where the robot moves) must be planes. In the literature, RANSAC is a widely used method for outlier rejection. However, it might be slow in critical circumstances. Therefore, it is proposed a new algorithm that accelerates RANSAC, maintaining its reliability. The algorithm, called FMBF, consists on comparing image texture patterns between pictures, preserving the most similar ones. There are several types of comparisons, with different computational cost and reliability. FMBF manages those comparisons in order to optimize the trade-off between speed and reliability.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de Mestrado em Engenharia Informática

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electroactive polymers are one of the most interesting class of polymers used as smart materials in various applications, such as the development of sensors and actuators for biomedical applications in areas such as smart prosthesis, implantable biosensors and biomechanical signal monitoring, among others. For acquiring or applying the electrical signal from/to the piezoelectric material, suitable electrodes can be produced from Ti based coatings with tailored multifunctional properties, conductivity and antibacterial characteristics, through Ag inclusions. This work reports on Ag-TiNx electrodes, deposited by d. c. and pulsed magnetron sputtering at room temperature on poly(vinylidene fluoride), PVDF, the all-round best piezoelectric polymer.. Composition of the electrodes was assessed by microanalysis X-ray system (EDS - energy dispersive spectrometer). The XRD results revealed that the deposition conditions preserve the polymer structure and suggested the presence of crystalline fcc-TiN phase and fcc-Ag phase in samples with N2 flow above 3 sccm. According to the results obtained from SEM analysis, the coatings are homogeneous and Ag clusters were found for samples with nitrogen flow above 3 sccm. With increasing nitrogen flow, the sheet resistivity tend to be lower than the samples without nitrogen, leading also to a decrease of the piezoelectric response. It is concluded that the deposition conditions do significantly affect the piezoelectric polymer, which maintain its characteristics for sensor/actuator applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tri-layered and bi-layered magnetoelectric (ME) flexible composite structures of varying geometries and sizes consisting on magnetostrictive Vitrovac and piezoelectric poly(vinylidene fluoride) (PVDF) layers were fabricated by direct bonding. From the ME measurements it was determined that tri-layered composites structures (magnetostrictive-piezoelectric-magnetostrictive type), show a higher ME response (75 V.cm-1.Oe-1) than the bi-layer structure (66 V.cm 1.Oe-1). The ME voltage coefficient decreased with increasing longitudinal size aspect ratio between PVDF and Vitrovac layers (from 1.1 to 4.3), being observed a maximum ME voltage coefficient of 66 V.cm-1.Oe-1. It was also observed that the composite with the lowest transversal aspect ratio between PVDF and Vitrovac layers resulted in better ME performance than the structures with higher transversal size aspect ratios. It was further determined an intimate relation between the Vitrovac PVDF Area Area ratio and the ME response of the composites. When such ratio values approach 1, the ME response is the largest. Additionally the ME output value and magnetic field response was controlled by changing the number of Vitrovac layers, which allows the development of magnetic sensors and energy harvesting devices.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Magnetoelectric microspheres based on piezoelectric poly(vinylidene fluoride) (PVDF) and magnetrostrictive CoFe2O4 (CFO), a novel morphology for polymer-based ME material, have been developed by an electrospray process. The CFO nanoparticles content in the (3-7 μm diameter) microspheres reaches values up to 27 wt.%, despite their concentration in the starting solution reaching values up to 70 wt.%. Additionally, the inclusion of magnetostrictive nanoparticles into the polymer spheres has no relevant effect on the piezoelectric β-phase content (≈60%), crystallinity (40%) and the onset degradation temperature (460º-465ºC) of the polymer matrix. The multiferroic microspeheres show a maximum piezoelectric reponse |d33|≈30 pC.N-1, leading to a magnetoelectric response of Δ|d33|≈5 pC.N-1 obtained when a 220 mT DC magnetic field was applied. It is also shown that the interface between CFO nanoparticles and PVDF (from 0 to 55%) has a strong influence on the ME response of the microspheres. The simplicity and the scalability of the processing method suggest a large application potential of this novel magnetoelectric geometry in areas such as tissue engineering, sensors and actuators.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de mestrado em Design e Marketing

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de mestrado em Engenharia Mecatrónica

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The MAP-i Doctoral Programme in Informatics, of the Universities of Minho, Aveiro and Porto

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nanoparticles (NPs) are being used or explored for the development of biomedical applications in diagnosis and therapy, including imaging and drug delivery. Therefore, reliable tools are needed to study the behavior of NPs in biological environment, in particular the transport of NPs across biological barriers, including the blood-brain tumor barrier (BBTB), a challenging question. Previous studies have addressed the translocation of NPs of various compositions across cell layers, mostly using only one type of cells. Using a coculture model of the human BBTB, consisting in human cerebral endothelial cells preloaded with ultrasmall superparamagnetic iron oxide nanoparticles (USPIO NPs) and unloaded human glioblastoma cells grown on each side of newly developed ultrathin permeable silicon nitride supports as a model of the human BBTB, we demonstrate for the first time the transfer of USPIO NPs from human brain-derived endothelial cells to glioblastoma cells. The reduced thickness of the permeable mechanical support compares better than commercially available polymeric supports to the thickness of the basement membrane of the cerebral vascular system. These results are the first report supporting the possibility that USPIO NPs could be directly transferred from endothelial cells to glioblastoma cells across a BBTB. Thus, the use of such ultrathin porous supports provides a new in vitro approach to study the delivery of nanotherapeutics to brain cancers. Our results also suggest a novel possibility for nanoparticles to deliver therapeutics to the brain using endothelial to neural cells transfer.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aquest article descriu els sensors enzimàtics i immunosensors electroquímics que s’han desenvolupat als nostres grups per a la detecció de la biotoxina marina àcid okadaic (OA), i discuteix la possibilitat d’integrar-los en programes de seguiment. Els sensors enzimàtics per a OA que es presenten es basen en la inhibició de la proteïna fosfatasa (PP2A) per aquesta toxina i la mesura electroquímica de l’activitat enzimàtica mitjançant l’ús de substrats enzimàtics apropiats, electroquímicament actius després de la seva desfosforació per l’enzim. Els immunosensors electroquímics descrits en aquest article es basen en un enzimoimmunoassaig sobre fase sòlida competitiu indirecte (ciELISA), amb fosfatasa alcalina (ALP) o peroxidasa (HRP) com a marcatges, i un sistema de reciclatge enzimàtic amb diaforasa (DI). Els biosensors presentats aquí s’han aplicat a l’anàlisi de dinoflagel·lats, musclos i ostres. Les validacions preliminars amb assaigs colorimètrics i LC-MS/MS han demostrat la possibilitat d’utilitzar les bioeines desenvolupades per al cribratge preliminar de biotoxines marines en mostres de camp o de cultiu, que ofereixen informació complementària a la cromatografia. En conclusió, tot i que encara cal optimitzar alguns paràmetres experimentals, la integració dels biosensors a programes de seguiment és viable i podria proporcionar avantatges respecte a altres tècniques analítiques pel que fa al temps d’anàlisi, la simplicitat, la selectivitat, la sensibilitat, el fet de poder ser d’un sol ús i l’efectivitat de cost. This article describes the electrochemical enzyme sensors and immunosensors that have been developed by our groups for the detection of marine biotoxin okadaic acid (OA), and discusses the possibility of integrating them into monitoring programmes. The enzyme sensors for OA reported herein are based on the inhibition of immobilised protein phosphatase 2A (PP2A) by this toxin and the electrochemical measurement of the enzyme activity through the use of appropriate enzyme substrates, which are electrochemically active after dephosphorylation by the enzyme. The electrochemical immunosensors described in this article are based on a competitive indirect Enzyme- Linked ImmunoSorbent Assay (ciELISA), using alkaline phosphatase (ALP) or horseradish peroxidase (HRP) as labels, and an enzymatic recycling system with diaphorase (DI). The biosensors presented herein have been applied to the analysis of dinoflagellates, mussels and oysters. Preliminary validations with colorimetric assays and LC-MS/MS have demonstrated the possibility of using the developed biotools for the preliminary screening of marine biotoxins in field or cultured samples, offering complementary information to chromatography. In conclusion, although optimisation of some experimental parameters is still required, the integration of biosensors into monitoring programmes is viable and may provide advantages over other analytical techniques in terms of analysis time, simplicity, selectivity, sensitivity, disposability of electrodes and cost effectiveness.